FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

Similar documents
AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS

Quantitative XRF Analysis. algorithms and their practical use

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

COMPARISON OF THREE UNIVERSAL CURVES FOR THE ESCAPE PROBABILITY OF X-RAY EXCITED ELECTRONS - I. THEORY

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

Standardless Analysis by XRF but I don t know what s in my sample!! Dr Colin Slater Applications Scientist, XRF Bruker UK Limited

Overview of X-Ray Fluorescence Analysis

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

USABILITY OF PORTABLE X-RAY SPECTROMETER FOR DISCRIMINATION OF VALENCE STATES

A MODIFIED APPROACH TO HOMOGENEITY TESTING AT MICROSCALE

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

Atomic Physics. Chapter 6 X ray. Jinniu Hu 24/12/ /20/13

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

LAB 01 X-RAY EMISSION & ABSORPTION

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS

CHARACTERIZATION OF Pu-CONTAINING PARTICLES BY X-RAY MICROFLUORESCENCE

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF

IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

X-RAY MICRODIFFRACTION STUDY OF THE HALF-V SHAPED SWITCHING LIQUID CRYSTAL

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

Horst Ebel, Robert Svagera, Christian Hager, Maria F.Ebel, Christian Eisenmenger-Sittner, Johann Wernisch, and Michael Mantler

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

1 of 5 14/10/ :21

EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION ACCURACY

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol

ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES

Interaction X-rays - Matter

at Oak Ridge National Laboratory.

Principles of Neutron Imaging

An Analysis of Secondary Enhancement Effects in Quantitative XRFA

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES

X-rays. X-ray Radiography - absorption is a function of Z and density. X-ray crystallography. X-ray spectrometry

ULTRATHIN LAYER DEPOSITIONS A NEW TYPE OF REFERENCE SAMPLES FOR HIGH PERFORMANCE XRF ANALYSIS

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

Determination of the activity of radionuclides

MONTE-CARLO MODELING OF SILICON X-RAY DETECTORS

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

QUANTITATIVE ENERGY-DISPERSIVE ELECTRON PROBE X-RAY MICROANALYSIS OF INDIVIDUAL PARTICLES

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

X-Ray Emission and Absorption

High Accuracy EUV Reflectometry and Scattering at the Advanced Light Source

CALCULATION OF THE DETECTOR-CONTRIBUTION TO ZIRCONIUM PEAKS IN EDXRF SPECTRA OBTAINED WITH A SI-DRIFT DETECTOR

BORON IN GLASS DETERMINATION USING WDXRF

Chap. 3. Elementary Quantum Physics

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

B. X : in phase; Y: out of phase C. X : out of phase; Y: in phase D. X : out of phase; Y: out of phase

An Introduction to Diffraction and Scattering. School of Chemistry The University of Sydney

Summer Students lectures

PART 1 Introduction to Theory of Solids

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

MEASUREMENT CAPABILITIES OF X-RAY FLUORESCENCE FOR BPSG FILMS

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

In Situ High-Temperature Study Of Silver Behenate Reduction To Silver Metal Using Synchrotron Radiation

EDS User School. Principles of Electron Beam Microanalysis

ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM.

RIETVELD REFINEMENT WITH XRD AND ND: ANALYSIS OF METASTABLE QANDILITE-LIKE STRUCTURES

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices

Atomic Emission Spectra. and. Flame Tests. Burlingame High School Chemistry

"What Do I Remember From Introductory Chemistry?" - A Problem Set

QUANTIFICATION OF MERCURY, LEAD, AND CADMIUM IN AQUEOUS SOLUTIONS BY ENERGY K X-RAY FLUORESCENCE SPECTROSCOPY

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

Pittcon External Seminar Template X-ray Analysis in Petrochemical Industry: Challenges and Solutions

QUANTITATIVE TEY (TOTAL ELECTRON YIELD) - THEORY, INSTRUMENTATION AND EXPRIMENTAL RESULTS

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

CHEM 1311A. E. Kent Barefield. Course web page.

Röntgenpraktikum. M. Oehzelt. (based on the diploma thesis of T. Haber [1])

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

Particle nature of light & Quantization

BRAGG AND BARKLA POLARIZATION IN EDXRF

X-Ray Fluorescence and Natural History

In-Situ Analysis of Traces, Minor and Major Elements in Rocks and Soils with a Portable XRF Spectrometer*

Neutron Powder Diffraction Theory and Instrumentation

MATERIALS CHARACTERIZATION USING A NOVEL SIMULTANEOUS NEAR-INFRARED/X-RAY DIFFRACTION INSTRUMENT

Application of X-ray Spectrometry at X-ray Absorption Edges for Investigation of Human Albumin

Lecture 23 X-Ray & UV Techniques

Gamma and X-Ray Standards

How many grams of sodium metal is required to completely react with 2545 grams of chlorine gas?

A NEW SMALL ANGLE X-RAY SCATTERING TECHNIQUE FOR DETERMINING NANO-SCALE PORE/PARTICLE SIZE DISTRIBUTIONS IN THIN FILM

Particle Behavior of Light 1. Calculate the energy of a photon, mole of photons 2. Find binding energy of an electron (know KE) 3. What is a quanta?

SYNCHROTRON X-RAY MICROBEAM CHARACTERIZATION OF SMECTIC A LIQUID CRYSTALS UNDER ELECTRIC FIELD

Transcription:

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS 255 Yoshiyuki Kataoka 1, Naoki Kawahara 1, Shinya Hara 1, Yasujiro Yamada 1, Takashi Matsuo 1, Michael Mantler 2 1 Rigaku Industrial Corporation,14-8,Takatsuki, Osaka 569-1146, Japan 2 Vienna University of Technology, Wiedner Hauptstrasse 8-1, A-14 Vienna, Austria ABSTRACT A new fundamental parameter method which employs measured Compton- and Thomson scattered characteristic tube line intensities for the estimation of non-measuring matrix elements has been developed. The concept of substituting a compound matrix by a single element of average atomic number has been efficiently applied to the analysis of biological samples, polymers, liquids, and powders where the non-measuring elements were unknown. It was found that the divergence of the primary x-ray beam and the resulting range of scattering angles should be accounted for in the calculation of scattering intensities. A computational model using Monte Carlo simulations has been developed which considers the distribution of scattering angles for each geometrical location of the sample, and is used in the quantification routine for actual analysis. INTRODUCTION Standardless analysis 1) using fundamental parameter methods is a key method for x-ray fluorescence analysis. However, if unknown non-measurable elements are present in samples such as polymers and biological materials and the elemental composition of the non-measuring elements is not known, accurate analysis was not easily possible. The proposed new method estimates the unknown matrix by measuring Compton- and Thomson scattered characteristic x-ray intensities from the x-ray tube and assumes an element of a corresponding average atomic number to represent an equivalent matrix effect for the analysis in that sample. The idea of average atomic numbers was reported by several authors 2,3). However, it was found in our studies that the divergence of the primary x-ray beam and the resulting range of scattering angles should be accounted for in the calculation of scattering intensities. A Monte Carlo simulation model has been developed to consider the distribution of scattering angles for each geometrical location within the detectable region of the sample and is used for the standardless quantification routine. EXPERIMENTAL The measurements were performed by sequential spectrometers Rigaku ZSX Primus and ZSX Primus-II; both are WDXRF spectrometers and employ Rh target end-window x-ray tubes. The angle of divergence in the primary x-ray beam is about 9 degree. Their Rh-Kα Compton and Thomson scattered lines were measured by using a LiF(22) crystal and scintillation counter. For the other measurements the same standard combinations of crystals and detectors as for regular analyses were employed. 32 standard samples were measured to create the sensitivity calibration. All samples were run without sample backing in order to avoid scattering from the backing materials. A polyester film was used to cover the sample when required and pressed pellets were measured for powder samples. The area density of sample was obtained by measuring sample

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

diameter and sample weight and the thickness was measured by using a vernier calipers in mm. The fundamental parameter method developed in this study is integrated in the standardless analysis software SQX for the ZSX Primus series spectrometers. 256 CALCULATION OF SCATTERING INTENSITIES The theoretical model of generating scattering x-rays is illustrated in Fig. 1. It should be noted that any inaccuracy in calculating the theoretical intensities of scattering lines directly affects the analytical results of all elements. There are two important assumptions in the conventional fundamental parameter method for the calculation of fluorescent x-rays: (1) all incident x-rays are irradiated under the same incident angle, and (2) all x-rays generated in the sample and emitted at a given observation angle are in principle detectable. However, this assumption is not necessarily valid, particularly in X-ray tube Incident x-rays Divergent Sample Geometry effect Detected region Confined Detecting system Figure 1. Generation of scattering x-rays view of the angular dependence of the scattering process and the short wavelength (and resulting high penetration power) of the scattering x-rays: As illustrated in Fig. 1, the primary x-ray beams from the x-ray tube are divergent so that the scattering angle varies with the geometrical location of the scattering event; the sample volume which is irradiated by the x-ray tube and also visible to the detector is confined by the divergence of the primary radiation on the tube side as well as by the opening angle of the collimator on the detection side. Considering the short wavelength of Rh-Kα photons and a matrix of light elements, those x-rays can penetrate too deeply into the sample as to be detectable after a scattering process. This geometrical confinement of the detectable region proves important in thick samples of a light matrix including many liquids. This effect is called wedge effect and the combination of the two discussed effects the geometry effect. Intenisty ratio 1.2 1..8.6.4.2. Rh-Kα Compton Rh-Kα Thomson 1 3 5 7 9 11 13 X-ray tube Sample Figure 2. Influence of incident angle to scattering intensity (Intensity ratios of incident angle: 6 deg to 5 deg) Detector In order to estimate the influence of the primary beam divergence, theoretical intensities were calculated for two incident angles, 5 and 6, and a fixed observation angle, for a range of elements from hydrogen to aluminum. Fig. 2 shows the intensity ratios I 6 /I 5 for Compton and Thomson scattering. While the Compton intensity ratios are close to 1 for all elements, they vary

strongly with atomic number of the scatterer for Thomson scattering with a maximum difference of about 5% in comparison to hydrogen. The differential scattering cross sections depend clearly on the scattering angles and the divergence of primary x-ray beams has to be considered in the calculation of scattering intensities. 257 MONTE CARLO SIMULATION MODEL In order to account for the geometry effect and compute the scattering intensities, a Monte Carlo simulation method has been developed based on the geometrical model shown in Fig. 3. Monte Carlo methods for fluorescent x-rays have been reported by several authors 4). They are based on the computation of a large number of random histories of photon interactions and observations of the effect of interest. In our model the following possible interactions are accounted for: Target Sample Detection 1. A photon is launched from the target. The target of the x-ray tube has a donut shape and the spectral intensity distribution of the emitted x-rays is taken Figure 3. Monte Carlo simulation for from experimental data. Point of emission and initial direction of each photon are defined by properly scattering intensity calculations distributed random numbers. The emitted x-ray beam is divergent. 2. The position where the photon impinges on the sample surface is determined; this is the starting point of path-length t within the sample as discussed in the following step. If the photon hits the sample mask it is discarded. 3. The point of scattering interaction within the sample is computed from a random path-length along its original direction into the sample, t = -ln(r) / μ total, where R is a standard uniform random number and μ total is the mass absorption coefficient of the sample for primary x-rays. 4. A scattering angle Ψ scat is calculated and used to calculate the scattering probability P = σ (Ψ scat ) / μ total from the differential scattering cross sections 5),6) σ(ψ scat ), for Compton as well as Thomson scattering. 5. The chance that the photon is actually detected depends on the capture angle, Ω, which is the solid angle under which the active detector area is seen from the scattering position, and several other instrument-specific factors such as sample mask, diaphragm, and analyzing crystal. They are combined in a factor Ω. If the scattered photon is blocked out, Ω =. 6. While the attenuation of the primary beam is inherently accounted for by the statistical distribution of path-lengths t (step 3), it is necessary to explicitly apply the absorption law for the scattered photons. Photons arriving at a point within the sample as specified in step 3 are scattered into the detector and registered with a probability P Ω exp(-μ total z / sin θ observation ). z is the depth of the interaction point from sample surface and θ observation is the observation angle. 7. Steps 1-6 are repeated until the preset number of histories is reached. t Ψ scat z Ω Sample mask Compton and Thomson scattering intensities were measured for various kinds of samples, and corresponding theoretical intensities were calculated by using the described Monte Carlo method; the obtained data were plotted against each other in Fig. 4 for comparison. The samples used for

Compton scattering in Fig. 4a were powders, polymers, biological samples and liquids, and show good linear relationship without regard to the sample type. The samples measured for Thomson scattering in Fig. 4b were polymers and liquids. The correlation for powder samples is slightly different from that for polymers and liquids. However, both calibrations gave good fits. 258 QUANTIFICATION The concept of average atomic numbers attempts to replace the actual matrix (of light, non-measuring elements) in a specimen by a single virtual element with the same impact upon the analyte line. In the quantification routine it is calculated as a balance component. For the computation of theoretical intensities of fluorescent and scattering x-rays, the following terms for absorption coefficients and scattering cross sections are used: Scattering cross sections: Compton Σσ Ci (λ,ψ)w i +σ CZav (λ,ψ)w Zav Thomson Σσ Ti (λ,ψ)w i +σ TZav (λ,ψ)w Zav Mass absorption coefficients: Σμ i (λ)w i +Σμ Zav (λ)w Zav σ C,i, and σ T,i are the cross sections for Compton and Thomson scattering, λ is the wavelength of primary x-rays, and W i is the concentration of analyte element i. Index Z av indicates the average atomic number of the virtual balance element. The scattering cross sections and absorption coefficients for the virtual atomic number Z av are calculated by interpolation of the scattering cross sections (and absorption coefficients, respectively) over the atomic numbers of actual elements. The relationship between scattering intensities and atomic numbers of samples was studied in order to allow a suitable choice between Compton and Thomson scattering lines for the determination of the average atomic number. Fig. 5 shows the relationship between Compton and Thomson scattering lines as a function of atomic number, for various sample thicknesses. In the case of Compton scattering (Fig 5a) the intensities drop steeply for thick samples and atomic number greater than 2. This is caused mainly by absorption within the sample. On the other hand, the intensity variations are small for very thin samples: There the scattering intensities are mainly proportional to the Compton scattering cross sections which vary slowly above hydrogen. Consequently, Compton scattering can be used for the determination of atomic numbers for thick samples but is not suitable for thin samples. Measured Intensity (a.u.) Measured Intensity (a.u.) 25 12 2 Compton 1 Thomson 15 8 6 1 4 5 2 2 4 6 8 5 1 15 Theoretical Intensity Theoretical Intensity (a) (b) Figure 4. Sensitivity calibrations for Compton and Thomson scattering lines

In the case of Thomson scattering (Fig. 5b) an ambiguity arises from the convex shape of the curve as there are always two atomic numbers giving the same intensity value over a wide thickness range. Therefore it cannot be used for the determination of the average atomic number of a sample. 259 Rh-Kα Compton intensity 25 2 15 1 5 1 2 3 4 5 6 7 8 9 (a) Rh-Kα Compton scattering Rh-Kα Compton/Thomson 5 4 3 2 1 Rh-Kα Thomson intensity 16 14 12 1 8 6 4 2 1 2 3 4 5 6 7 8 9 (c) Ratio of Rh Κα Compton to Thomson intensities 1 2 3 4 5 6 7 8 9 (b) Rh-Kα Thomson scattering 9999mg/cm2 624mg/cm2 2mg/cm2 1mg/cm2 Figure 5. Relationships between scattering intensities and atomic numbers Fig. 5c exhibits the ratio of Compton to Thomson intensities. The differences between various sample thicknesses are very small and each intensity ratio corresponds in a unique way to a single atomic number. However, the differences of intensity ratios are very small for atomic numbers above 7. Considering the relationships above, the following scheme is used: Because the Compton intensity is of advantage for the determination of the atomic number in thick samples, it is used for samples with a large mass thickness and a medium or heavy matrix such as in powder of oxides. The intensity ratio of Compton to Thomson scattering is used for very light matrix samples such as polymers and liquids, where the effective sample (mass-) thickness is small. Set initial value Convert measured intensities to theoretical intensity scale Calculate theoretical intensities of last composition Obtain average atomic number and concentrations of measured elements using differential equation Converged Output result Figure 6. Quantification procedure

The scheme of the quantification procedure of the fundamental parameter method is illustrated in Fig. 6. 26 EXAMPLES OF ANALYTICAL RESULTS The results shown in Tab.1 are from a polyethylene sample which is a certified reference material of BCR-68. The non-measuring elements carbon and hydrogen were estimated by their computed average atomic number. Tab.2 shows data from biological material of tomato leaves which is a certified reference material of NIST 1573a. In both cases the results show good agreement between standard and analyzed values. The successful applicability of the method was also demonstrated by other kinds of materials such as geological samples and liquids. Table 1: Polymer (BCR-68) unit: mass% Element Si Cl Ca Ti Cr As Br Sr Cd Ba Hg Pb Result.51.95.5.13.116.32.78.4.132.246.2.11 Std value -.81 - -.115.31.88 -.14 -.25.18 Table 2: Tomato leaves (NIST 1573a) unit: mass% Element Mg Al P S Cl K Mn Fe Ni Cu Zn Br Result 1.1.547.213 1.1.67 2.78.263.374.6.6.28.13 Std value 1.2.598.216.96.66 2.7.246.368.2.5.31.13 CONCLUSION A Monte Carlo simulation was introduced in order to compute accurate scattering intensities with consideration of geometry effect. A concept of average atomic number is employed for the estimation of non-measuring elements by using scattering line intensities. Good analytical results could be obtained for various kinds of samples such as powders, polymers and liquids. REFERENCES 1. Kataoka,Y.; The Rigaku Journal, 1989, 6, 33-39 2. Van Espen, P.; Van`t dack, L.;Adams, F.; Van Grieken, R., Anal. Chem., 1979, 51, 961-967 3. Nielson, K.K.; Rogers, V.C., Advances in X-ray Analysis, 1984, 27, 449-457 4. Mantler, M.; Advances in X-ray Analysis, 1999, 41, 54-61 5. Cromer,D.T ; Mann,J.B, J.Chem.Phys.,1967,47, 1892-1893 6. Cromer,D.T; Waber,J.T, International Tables for X-ray Crystallography,1974,4,99-12