Automatic Potentiometric Titrator

Similar documents
Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Automatic Potentiometric Titrator [AT-710S]

KEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix

Karl-Fischer Titration the method for determining water

Automatic titrators, TitroMatic

OPTION. Karl Fischer Moisture Titrator [Volumetric titration] Karl Fischer Moisture Titrator [Coulometric titration]

KEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

The first address for Titration. TITRONIC 300 and TitroLine 5000

Easy and reliable KF titrations From 1 ppm to 100%

Kjeltec 2300 Analyzer Unit

From 1 ppm to 100% Karl Fischer water content determination

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

JAPAN QUALITY. Automated Clinical Analyzer

RA-520N/RA-500N/RA-410

473 Dew Point Hygrometer

JAPAN QUALITY. Automated Clinical Analyzer

Moisture Analyzers.

473-SHX Dew Point Mirror

473 Dew Point Hygrometer

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Titration Catalog. Systems and Autosampler

ADI 2040 Process Analyzer

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

Geavanceerde bepaling van water in poeders en vaste stoffen via geautomatiseerde Karl Fischer titratie. Peter van de Spreng 8 November 2011

Mobile coulometer for water determination anywhere you want

One-hand ph/temperature measuring instrument

High Perfomance: AT-510 Low Cost : AT-500N-1, AT-500N-2 Multi-channel Software : AT-Win. FDA 21 CFR Part 11 Compliant Software : AT-Win/ER

Concise laboratory catalogue

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL. CPRI Section II -Technical Specification

Potentiometric measurement of ph

Karl Fischer Volumetric Titration Theory and Practice

ISEmax CAM40/CAS40. Technical Information

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

Karl Fischer Titration Of Food : Towards Complete Automation

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Automated Clinical Analyzer

Mercaptan Sulfur in Gasoline and Kerosene Aviation Turbine and Distillate Fuels

MERCAPTAN SULFUR IN GASOLINE & KEROSENE AVIATION TURBINE & DISTILLATE FUELS USING ASTM D3227

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Determination of Total Base Number (TBN)

Acceleration/Velocity/Displacement VIBRATION METER

Acid-Base Titration. Evaluation copy

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

12.01 Determination of the isoelectric point of an amino acid (glycine)

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Automatic Potentiometric Titrator AT-710 Operation Manual

Electrodes - Connect/Replace. Reagents - Install/Replace. Select method ph electrode calibration. Reagent calibration.

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Acid-Base Titration. Sample

Titrimetric Determination of EASTMAN Color Developing Agent, CD-3, in Process ECN-2 Developer with Sulfato Cerate

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Related concepts Electrolyte, electrical conductance, specific conductance, ion mobility, ion conductivity, conductometry, volumetry.

TitriSoft 2.5. Content

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

The Clinical Chemistry System that offers more so you do less!

TitroLine alpha plus From precise programmable piston burette to fully automatic titration system

ph / Temperature Meter for Cheese with Application Specific Probe

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Conductometric Titration & Gravimetric Determination of a Precipitate

PC Control / Touch Control

Titration of a strong acid with a strong base with Cobra4

PAA-ANALYZERS PRINCIPLE OF OPERATION

Operating Instructions. Titration Excellence Terminal

Automated Chloride Determination in Concrete

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

Titration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES

Titration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES

Titration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES

Easier Titration at any level of complexity: TitroLine alpha plus

VIBRATION METER. Instruction Manual.

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Rapid RH Portable ph Meter. User's Manual

cobas e 411 analyzer Confidence in every result.

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

QDTL. Liquid Mass Transfer and Diffusion Coefficient Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

Freezing point osmometry

A new chapter. medicacorp.com

Karl Fischer Titrator

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Acid-Base Titration. Volume NaOH (ml) Figure 1

Analytix. HYDRANAL Product Line Overview

Freezing point osmometry

Operating Instructions. METTLER TOLEDO DL37 KF Coulometer

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

MULTI_T. Digital Titrator for Multi-tasking Titrations

USER MANUAL. Aquamax TAN

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

2100TR Liquid Scintillation Counter

Exercise 2-4. Titration of a Buffer Solution EXERCISE OBJECTIVES

ph Probe ReallyEasyData com

Transcription:

Automatic Potentiometric Titrator AT-610

Automatic Potentiometric Titrator Two Different Titrations can be Performed Simultaneously --- Allow for Space-saving. Also, a Karl Fischer Moisture Titrator can be combined. AT-610 is the highest-end model among the KEM Automatic Potentiometric Titrators, featuring an over-sized touch screen LCD to allow for better operations. In combination with the KEM Karl Fischer Moisture Titrator 610 series, the end-user can simultaneously carry out not only a regular titration by AT-610 but moisture titration by the Karl Fischer Moisture Titrator 610 series. The combination with the optional CHA-600 Sample changer allows for even better operations and laborsaving.

Features Touch Screen LCD Input System 1 Newly adopted a logical, easy-to-use Graphical User Interface utilizing a high-resolution touch-screen LCD (Liquid Crystal Display) provides easy viewing and high visibility in addition to simplified key entry by touch-screen control for swift maneuverability in operation. 2 3 4 Large color LCD with a touch screen feature (8 inch-wide) Temperature measurement with Platinum Thermal Resistor (Pt100) Pt100 platinum thermal resistor specified in JIS C1604 as thermal resistor is a most precise and reliable one compared with a conventional temperature measurement by thermistor. Feature of the Karl Fischer moisture titration is now added This new model can work on moisture titration when connected with the optional Karl Fischer Moisture Titration unit. That is, not only regular but moisture titration can be simultaneously performed on a single control panel. For an optional moisture titration, both volumetric and coulometric systems are available. Two different potentials (ph / temperature, ph / transmittance or the like) can be simultaneously recorded The two potentials, e.g. ph and temperature, ph and conductivity or ph and transmittance can be plotted on single titration curve. Thereby, you can see the behavior of conductivity in relation to changing ph or the changes of color by the indicator in correlation to the actually changing ph. 5 6 7 8 The control unit and the titration unit can be remotely placed and operated The control panel and the titration unit can be separated more than 10 meters away. Safe measuring environment is secured by installing the titration unit in a drafter while the operator works on the control unit outside a drafter. Compact Flash (CF) card is now equipped for an extended memory storage CF card can store measurement results and methods for titrations. The electronically stored data can serve as future references to review the results or the reevaluation of past records. Two titrations can be simultaneously performed in parallel This new model works as two titration units in one when connected with an optional titration unit. For instance, both acid base and salt titration can be performed at the same time. It goes without saying that this unit can save your bench space a lot. Feature of GLP/GMP support Conforming to GLP and GMP, those requirements like control of the testing equipment including checks of the unit performance with standard substances or calibrating the electrode are satisfied by recording their results. Those records can be viewed on history archive screen. In addition to recording maintenance results, the advance notice of reagent replacement date and piston replacement date appears on display to affirm correct and in-time maintenance.

Examples of Combination CASE 1 Titrator + Titrator AT-610-S/2nd CASE 2 Titrator + Moisture Titrator (Volumetry) MKA-610-T/2nd CASE 3 Titrator + Moisture Titrator (Coulometry) MKC-610-D/2nd

Specifications / Accessories Specifications Model name Detection range AT-610 Automatic Potentiometric Titrator 1) Potentiometric : -2000mV~+2000mV 2) ph : 0.00~14.00pH 3) Temperature : 0~100 C Ext. I/O COM port (Mini DIN 8-pin) x 2 channels For Printer, Electronic balance and Data Capture Software K-NET port x 2 channels, For titrating unit Calculation Concentration, Statistical data (Mean, SD 2 and RSD 3 ) Burette precision 50mL(option) : ±0.05mL, Repeatability ±0.02mL 20mL(standard): ±0.02mL, Repeatability ±0.01mL 10mL(option) : ±0.015mL, Repeatability ±0.005mL 5mL(option) : ±0.01mL, Repeatability ±0.003mL 1mL(option) : ±0.005mL, Repeatability ±0.001mL Titration mode Blank, Auto Titration, Auto Intermit, Intermit, Petroleum Titration COD control and Stat control--total 7 modes Number of methods Standard methods: 50; Combined methods: 10(Max five methods can be combined.) Kinds of titration Potentiometric (acid/base, redox, precipitation) Photometric, Polarization and Conductometric titrations Titration forms Full titration(auto EP detection) / EP Stop / Level Stop/ Intersect / EP Stop Level Stop / Learn titration Special applications Measurement of electrode potential(ph, potential), pka(dissociation constant of acid) Two-system simultaneous recordings of input potentials (Examples: Titration volume vs. ph+%t, Titration volume vs. ph+µs) Input method (MMI) 1 Direct operations on a touch screen Display 1) 8-inch color LCD with 256 colors (800x600-dot resolution) 2) Simultaneous 2-channel display(even for a Karl Fischer Moisture Titrator) GLP support functions Scalability Ambient conditions Burette unit: Max 10 units (Including one built-in) Measuring unit: Titrator (AT-610), Moisture titrator (either MKA-610 or MKC-610), Multiple sample changer (CHA-600) 1) Temperature: 5~35 C 2) Humidity: Below 85%RH (No condensation) Power consumption Main control unit: 100~120V AC / 200~240V AC ±10% 50/60Hz; Approx. 20W Titration unit/stirrer: 100~120V AC / 200~240V AC ±10% 50/60Hz; Approx. 25W Printer: 100V, 120V or 230V AC ±10%, 50/60 Hz; Approx. 7W Dimension and Weight Advanced registration of operators (Max 50 persons) Titrant: Warning of low-level titrant residue, Announcement of factor calibration date, Announcement of piston replacement date, Announcement of titrant replacement, Inspection: Announcement of inspection date, Records of inspection results Maintenance of electrodes: Announcement of calibration date, Records of calibration Inspection of burette capacity: Inspecting function and records of inspection results Main control unit : 230(W)x280(D)x255(H)mm; Approx. 2.0kg Titration unit : 120(W)x363(D)x610(H)mm; Approx. 4.0kg Stirrer : 118(W)x225(D)x320(H)mm; Approx. 2.0kg Printer : 106(W)x180(D)x88(H)mm; Approx. 0.4kg 1 MMI : Man Machine Interface 2 SD : Standard Deviation 3 RSD : Relative Standard Deviation Accessories Type Part name Combined glass electrode(98100c171) Connecting cable for electrode(984290012) Temperature compensation electrode(98100t171) Photometric sensor(120011001448) Interference filter 530nm(12001120048) 630nm(12001120148) Twin platinum electrode(98100m511) Conductometric sensor(98101k321) Connecting cable(984280032) Internal solution for reference electrodes(988115001) Single head wrench(985143339) Piston extraction rod(985515002) Stirrer rotor Number sticker Polyethylene bottle(69000280048) Printer roll Ribbon cartridge Operation manual Remarks Standard kit Used for ordinary titration such as Acid-base titration or Redox titration Photometric titration kit AT-610-PT Used for not only Acid-base titration or Redox titration but Water hardness Metal concentration of plating bath or the like Polarization titration kit AT-610-OT Used for not only Acidbase titration or Redox titration but Diazotisation titration for such as dyestuff Conductivity titration kit AT-610-CT Used for not only Acidbase titration or Redox titration but Conductometric titration ph Dual input kit AT-610-TT 1 1 1 1 1 Used for ordinary titration such as Acid-base titration or Redox titration

Additional equipment (Option) Multiple Sample Changer CHA-600 Features 1) A plural number of samples can be automatically measured in a simple operation From the beginning of start until the end of measurements, a number of samples in vials on the rack of a turn table can be continuously measured while unattended. Specifications Model name Max No. of sample Available Vials 200mL beaker (PP) 1 100mL beaker (PP) 200mL beaker 300mL tall beaker 200mL Erlenmeyer 50mL beaker 100mL beaker 100mL tall beaker 200mL tall beaker Rinsing method Rinsing equipment Rinse solution Stirring unit Sequence setting Sequence control Method of display Data communication Dimension Ambient conditions Power supply Power consumption Weight 1 PP : Polypropylene CHA-600-12 CHA-600-18 12 18 Standard accessory Yes(Need adjuster) Standard accessory Yes Yes Yes Shower rinsing and dip rinsing(option: It can be rinsed by two solutions.) Exclusive rinse bath Pure water, Alcohol or the like Magnetic stirrer(built-in at the titration position) Propeller stirrer(option) Set on Automatic potentiometric titrators 1) Automatic: Start on Automatic potentiometric titrators 2) Manual : Control with keys LED S-BUS: For connecting with AT-610/AT-510 520(W)x426(D)x369(H)mm 5~35 C; Below 85% RH 100-120/200-240V AC, 50/60Hz Approx. 50W Approx. 17kg 2) Well designed cleaning method, pre-treatment and post-treatment The option of selecting shower or dip rinsing, and more elaborated combination of these processes can cope with various types of samples at a time. In addition to pre-treatment or dosing solvent medium, the waste liquid after measurement can be separately drained out and collected. 3) User sequence that can be programmed as you want User can select a desired cleaning process the most appropriate to each sample character when connected to AT-610 or AT-510 automatic potentiometric titration unit so that both aqueous and non-aqueous samples can measured at the same time. 4) Pre-treatment by adding pre-dose reagent in advance This is most useful for those samples of slow reaction. Reagent can be dosed to each or all of the samples on rack prior to start of a series of measurement. 5) Hood can be installed for safety use (Option) The hood provides an environment of safety and security protecting the operator from hazardous condition when handling toxic chemicals like acetic acid or pyridine. 6) Thermal water circulator can be installed (Option) This optional thermal water circulator is necessary for those samples that can be measured only at low temperature (approx. 10 C) or at high degrees (approx. 60 C). Also, it is useful for those samples that generate heat while being titrated. Automatic Piston Burette Specifications Description Automatic piston burette Type APB-610 APB-600-AT Display unit LCD, 2 lines x 16 char., Backlight Blue LED Burette precision 50mL burette ±0.05mL; Repeatability ±0.02mL 20mL burette ±0.02mL; Repeatability ±0.01mL 10mL burette ±0.015mL; Repeatability ±0.005mL 5mL burette ±0.01mL; Repeatability ±0.003mL 1mL burette ±0.005mL; Repeatability ±0.001mL Delivery rate Setting of delivery rate can be changed 50mL burette: 0.1~150mL/min 20mL burette: 0.02~60mL/min 10mL burette: 0.01~30mL/min 5mL burette: 0.05~15mL/min 1mL burette: 0.001~3mL/min Suction/Delivery selection Automatic selection by ceramic valve Wetted materials PTFE, glass and ceramic Reagent bottle 1000mL Polypropylene (PP) bottle I/O interface S-BUS x 2ch for Automatic Communication established Potentiometric Titrator and Sample exclusively with the measuring Changer unit Power jack for magnetic stirrer (Optional at the factory) RS-232C Mini DIN 8-pin x 1ch Jack for sensor of compensating titrant temperature and Sensor Pt100; precision of temperature reading: ±0.5 C Power supply Power consumption Dimension Weight 100~120/200~240V AC, 50/60Hz Approx. 20W 120(W) 363(D) 610(H)mm (Including burette unit) Approx. 5kg,EIJHE>KJA@ >O KYOTO ELECTRONICS MANUFACTURING CO.,LTD. Overseas Division : 8-3 Niban-cho Chiyoda-ku TOKYO 102-0084, JAPAN Fax : +81-3-3237-0537, Phone : +81-3-3239-7333 URL : http://www.kyoto-kem.com CE ISO 9001 for quality assurance GLP/GMP marked for conformed product safety ISO 14001 environmental management systems Specifications and design subject to change for improvements without notice. printed in Japan. 502TD53A