arxiv: v1 [physics.ins-det] 21 Dec 2017

Similar documents
arxiv: v3 [physics.ins-det] 31 Mar 2017

arxiv: v1 [physics.ins-det] 5 Nov 2015

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Journal Publication. Photon detection system for ProtoDUNE dual phase

Hands on DarkSide-50: Low Energy Calibration

Particle Energy Loss in Matter

Effects of Nitrogen and Oxygen contamination in Liquid Argon

PHY 599: How it is usually done

- ICARUS status and near future

ICARUS T600 experiment: latest results and perspectives

Neutrino Oscillations Physics at DUNE

Particle Energy Loss in Matter

Giant Liquid Argon Observatory for Proton Decay, Neutrino Astrophysics and CP-violation in the Lepton Sector (GLACIER)

The Short Baseline Neutrino Program at Fermilab

arxiv: v1 [astro-ph] 30 Jul 2008

Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures

Ionization Detectors. Mostly Gaseous Detectors

Simulation of charge transport in pixelated CdTe

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Measurement of the transverse diffusion coefficient of charge in liquid xenon

Publications of Francesco Arneodo: journal articles

Direct dark matter search using liquid noble gases

The NEXT-100 experiment for Neutrino-less Double Beta decay: Main features, Results from Prototypes and Radiopurity issues.

Direct dark matter search using liquid noble gases

GEM: A new concept for electron amplification in gas detectors

X-ray ionization yields and energy spectra in liquid argon

Generic Detector. Layers of Detector Systems around Collision Point

Charge readout and double phase

Two-phase and gaseous cryogenic avalanche detectors based on GEMs

arxiv: v1 [physics.ins-det] 14 Jan 2016

Electron emission properties of two-phase argon and argon-nitrogen avalanche detectors

Dark matter search activities at CIEMAT

X-ray ionization yields and energy spectra in liquid argon

The Dual-Phase Liquid Xenon Time Projection Chamber (TPC) of Münster

Application of GLoBES: GLACIER on conventional neutrino beams

solenoid and time projection chamber for neutron lifetime measurement LINA

Seminar talks. Overall description of CLAS12 (Jefferson Lab) MAPS. Talks on Feb. 6 th, (Contact JR) (Contact TS)

1. The ICARUS T600 detector

arxiv: v1 [physics.ins-det] 23 Dec 2013

Background optimization for a new spherical gas detector for very light WIMP detection

PHYS 3446 Lecture #12

Electron Bubble Tracking Detector R&D

arxiv: v1 [physics.ins-det] 23 Oct 2007

Electron transparency, ion transparency and ion feedback of a 3M GEM

PMT Signal Attenuation and Baryon Number Violation Background Studies. By: Nadine Ayoub Nevis Laboratories, Columbia University August 5, 2011

Experimental results from ARGONTUBE, a 5 m long drift LAr TPC

3 Gaseous Detectors. Detectors for Particle Physics Manfred Krammer Institute for High Energy Physics, Vienna, Austria

Average value of available measurements of the absolute air-fluorescence yield

The ArDM project: A Liquid Argon TPC for Dark Matter Detection

08 - Miscellaneous and historical detectors

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

EEE4106Z Radiation Interactions & Detection

DarkSide. Bianca Bottino Università di Genova and INFN Sezione di Genova on behalf of the DarkSide collaboration 1

PoS(ICHEP2016)293. The LArIAT experiment and the charged pion total interaction cross section results on liquid argon. Animesh Chatterjee

Neutron capture and fission reactions on. sections, -ratios and prompt -ray emission from fission. 1 Introduction and Motivation

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

arxiv: v1 [physics.ins-det] 1 Nov 2011

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

Observation of flavor swap process in supernova II neutrino spectra

Chapiter VII: Ionization chamber

arxiv: v3 [physics.ins-det] 5 Jan 2012

Appendix A2. Particle Accelerators and Detectors The Large Hadron Collider (LHC) in Geneva, Switzerland on the Border of France.

Ionization Detectors

arxiv:astro-ph/ v1 15 Feb 2005

QUARKNET ANNUAL REPORT 2017 UNIVERSITY OF TENNESSEE, KNOXVILLE S. GOLLAPINNI, K. GUNTHOTI September 24, 2017

arxiv:astro-ph/ v2 10 Jan 2007

3. Gas Detectors General introduction

PoS(EPS-HEP2017)483. The CERN Neutrino Platform. Stefania Bordoni CERN

The ICARUS Project FRONTIERS IN CONTEMPORARY PHYSICS II. Vanderbilt University, March 5-10, Sergio Navas (ETH Zürich) " Atmospheric neutrinos

Lecture # 3. Muhammad Irfan Asghar National Centre for Physics. First School on LHC physics

DUNE detector design and lowenergy reconstruction capabilities. Inés Gil Botella

arxiv: v1 [hep-ex] 1 Oct 2015

Performance of the ICARUS T600 detector

arxiv: v1 [physics.ins-det] 20 Dec 2017

arxiv: v1 [physics.ins-det] 29 Dec 2010

On the energy deposition by electrons in air and the accurate determination of the air-fluorescence yield

DETECTORS. I. Charged Particle Detectors

The outline. 1) Detector parameters: efficiency, geometrical acceptance, dead-time, resolution, linearity. 2) gaseous ionization chambers

PoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University

Sensitivity of the DUNE Experiment to CP Violation. Lisa Whitehead Koerner University of Houston for the DUNE Collaboration

Liquid Argon TPCs for future neutrino oscillation experiments

WARP. C. Galbiati, C. DMSAG Aug

Low Energy Particles in Noble Liquids

Track Resolution Measurements for a Time Projection Chamber with Gas Electron Multiplier Readout

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

Dark Matter Detection and the XENON Experiment. 1 Abstract. 2 Introduction

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Tracking properties of the ATLAS Transition Radiation Tracker (TRT)

Optical readout of secondary scintillation from liquid argon generated by a thick gas electron multiplier

Lecture 4. Detectors for Ionizing Particles

Measurement of Muon Momentum Using Multiple Coulomb Scattering for the MicroBooNE Experiment

Neutrino oscillation physics potential of Hyper-Kamiokande

Chapter 3 Gas Filled Detectors

arxiv: v1 [hep-ex] 26 Jul 2011

arxiv: v1 [physics.ins-det] 31 Oct 2015 Alden Fan 1

Nuclear Physics and Astrophysics

PoS(KAON13)012. R K Measurement with NA62 at CERN SPS. Giuseppe Ruggiero. CERN

Micro Pixel Chamber Operation with Gas Electron Multiplier

THE NEXT EXPERIMENT FOR NEUTRINOLESS DOUBLE BETA DECAY SEARCHES ANDER SIMÓN ESTÉVEZ ON BEHALF OF THE NEXT COLLABORATION

Luca Grandi.

arxiv: v1 [physics.ins-det] 13 Apr 2018

Transcription:

Prepared for submission to JINST LIDINE 2017: Light Detection in Noble Elements 22-24 September 2017 SLAC National Accelerator Laboratory arxiv:1712.07971v1 [physics.ins-det] 21 Dec 2017 Impact of the positive ion current on large size neutrino detectors and delayed photon emission R. Santorelli, a,1 S. di Luise, b E. Sanchez Garcia, a P. Garcia Abia, a T. Lux, b V. Pesudo, a L. Romero a a Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Av. Complutense 40, 28040 Madrid, Spain b Institut de Física d Altes Energies (IFAE), Campus UAB, Bellaterra (Barcelona), Spain E-mail: roberto.santorelli@ciemat.es Abstract: Given their small mobility coefficient in liquid argon with respect to the electrons, the ions spend a considerably longer time in the active volume. We studied the effects of the positive ion current in a liquid argon time projection chamber, in the context of massive argon experiments for neutrino physics. The constant recombination between free ions and electrons produces a quenching of the charge signal and a constant emission of photons, uncorrelated in time and space to the physical interactions. The predictions evidence some potential concerns for multi-ton argon detectors, particularly when operated on surface. Keywords: Only keywords from JINST s keywords list please ArXiv eprint: 1234.56789 1Corresponding author.

Contents 1 Introduction 1 2 Charge density in steady state 2 3 Field distortion and secondary electron-ion recombination 3 4 Conclusions 5 1 Introduction Both photons at 128 nm and ion/electron pairs are generated simultaneously by particle interactions in argon. In a typical liquid argon time projection chamber (LAr-TPC), photon sensors are used to detect the prompt scintillation light, while the electrons drift to the anode by mean of a constant electric field E d. The drift field prevents the full recombination of the opposite charges created in the ionization track, reducing the so-called recombination light and making possible the collection of the ionization signal. In case of a single-phase TPC, the electrons are directly collected by thin wires placed in the liquid [1], while, in case of a double-phase liquid/vapor chamber, they are extracted to a gas region placed above the sensitive volume [2]. In the latter case, the charge can be amplified through a sufficiently intense electric field ( 30 kv/cm) with the production of a Townsend avalanche with electron/ions pairs. The positive and negative charges created in the LAr bulk drift along the same E d field lines, although the ions have a mobility, thus a velocity, much smaller than the electrons (v i v e ). Considering a typical field, E d = 1 kv/cm, the electron velocity is of the order of v e 2 mm/µs [3]. The ion mobility is not very well know, and the values reported in the literature range between µ i 2 10 4 cm 2 V 1 s 1 [4] and µ i 1.6 10 3 cm 2 V 1 s 1 [5] with the liquid in steady state. Even considering the more conservative larger value, the expected ion velocity at 1 kv/cm is v i 1.6 10 5 mm/µs, which is five orders of magnitude lower than that of the electrons at the same field. Once a drift field is applied, the electrons are promptly collected while the ions stay in the LAr for much longer time. As a consequence, the positive charge density can increase with time, reaching a constant value dependent on the total ionization produced and on the amplitude of the field itself. As a consequence, in stable conditions, the average density of positive ions is much larger than that of electrons (d I d e ). This space charge can locally modify the drift lines, the amplitude of the electric field, and ultimately the velocity of the electrons, thus, a displacement in the reconstructed position of the ionization signal can be produced. Additionally, for relatively large values of d I, the positivecharge density can be sizable such that the probability of a secondary electron/ion recombination, different than the recombination that occurs within the ionization track [6], has to be considered 1

between the drifting electrons and the free positive ions. The effect can cause an additional signal loss, with a probability dependent on the electron drift path, that could resemble the charge quenching given by the contamination of the electronegative impurities in LAr. At the same time it can produce the emission of photons through channels similar to the recombination light. This effect can be particularly relevant for double phase detectors foreseeing large charge amplification factors, where the ions, created in the vapor volume, may cross the gas-liquid interface and further increase d I in the active LAr volume. 2 Charge density in steady state In an underground LAr experiment, the dominant contribution to the charge production is typically given by the 39 Ar decay, a β emitter with a Q-value of 565 kev whose activity in natural argon is 1 Bq/kg [7], or, for liquid argon in standard conditions, 1400 Bq/m 3. Assuming that the mean energy deposited per decay in the active volume is approximately one third of the total Q-value, and considering that the mean energy required to create an ion-electron pair in LAr is W = 23.6 ev [8], one 39 Ar decay produces in average 8 10 3 pairs, therefore the ionization rate, h 0, due to 39 Ar is 1.1 10 7 pairs/(m 3 s). In case the detector is located on the Earth surface, the contribution to the total ionization produced in the active volume is mainly given by the muons, with an average flux at sea level of 168 muons/(m 2 s) [9]. Considering that most of the muons are at their minimum ionizing energy, the energy loss in argon as a function of the density is 1.5 MeV/cm 2 /g, and the average energy deposited is 210 MeV/m per muon or 35 GeV/(m 3 s) in liquid argon. Assuming the W value above, the ion production rate is h 0 = 1.5 10 9 pairs/(m 3 s), two orders of magnitude greater than that of the 39 Ar decay. At zero field, the opposite charges created in liquid promptly recombine producing photons. Once the electric field is present, the columnar recombination of the electrons with the parent ions is suppressed, and the opposite charges drift toward the anode and the cathode. The average number of free charges escaping the recombination, h, is a function of the drift field, and is usually approximated with the so-called Birks law, h = h 0 /(1 + k E /E d ) [10]. The measured value of constant k E in argon is 0.53 ± 0.04 kv/cm [11]. Given the much larger velocity of the electrons with respect to the ions, the negative charge created is promptly extracted from the LAr volume in a timescale of ms (v e 2 m/ms with E d 1 kv/cm). At the same time, minutes are necessary for the ions to drift entirely along the same volume (v i 1.6 10 2 m/s), thus a positive charge density, much larger than the negative one, builds up in the LAr bulk. Electronegative molecules, like oxygen and water, diluted in the argon volume may trap the drifting electrons, creating negative ions which have a drift velocity similar to the argon ones. The negative-ion density can partially cancel the effects of the positive space charge. A stationary condition is reached when all the concentrations do not change significantly anymore with time. Both timescale of the species evolution and steady value depend on the drift field, ionization rate and impurities concentration. The solution to this problem is calculated with a Finite Element Analysis (FEA) approach. A model is implemented in COMSOL Multiphysics [12], including the Electrostatics and Transport of Diluted Species modules. The problem consists of calculating evolution and stationary state 2

Figure 1. Evolution with time of the different density of species in LAr in four timescales (increasing from left to right, and from top to bottom). After a few seconds the positive-ion density is several orders of magnitude larger than that of electrons and negative ions. of the ions and electrons in a 1 1 1 m 3 box filled with liquid argon, considering the ionization produced mainly by cosmic muons and a 1 kv/cm drift field. Diffusion of the charges and recombination is taken into account. The evolution of the species on four different timescales is shown in Fig. 1. Given their relatively fast velocity compared to the other species, the free electrons reach a constant density in less than one ms, with an average d e value of the order of 0.3 cm 3. This value are, as expected, comparable with the maximum drift time for the considered geometry. Both the negative and positive ions reach a steady state within a timescale of the order of one minute. The amount of electronegative impurities is much larger than the amount of drifting electrons, however, assuming an electron lifetime in LAr of the order of 5 ms or more, the rate of formation of negative ions is much smaller compared to the ionization produced. The average negative-charge density (both electrons and ions) is negligible compared to the positive one, which is about 1.7 10 5 cm 3 or d I 1.7 10 11 m 3. A similar value can be derived from the analytic estimation reported in [13]. The results demonstrate that, in steady state, a massive space charge is present in the LAr bulk, thus its impact on the drift field and charge collection has to be evaluated. 3 Field distortion and secondary electron-ion recombination The positive-charge density can modify the effective electric field. In the limit of a null ion current, the drift field is constant and it is equal to the cathode voltage divided by the total drift length, L. 3

Figure 2. Configuration of the drift lines near a positive ion placed at (0, 0) for a nominal drift field of 1 kv/cm. The thick red line is the envelope of the field lines ending on the ion. On the contrary, an ion cloud makes the field to change with the drift coordinate l, from a minimum at the anode to a maximum at the cathode. In order to achieve the desired minimum field value, it is necessary to increase the nominal cathode voltage by a factor dependent on the charge density. At the same time the space charge modifies the direction drift lines and the velocity of the electrons produced in the liquid, leading to a displacement in the reconstructed position of the ionization signal. Fig. 2 shows the field paths approaching an ion positioned at (0, 0), which has a negligible size at the µm scale, for E d = 1 kv/cm. The red curve is the envelope of all the field lines ending on the ion (detailed calculation in [13]). The ion is motionless compared to the free electrons drifting by means of the electric field, which is not uniform given the presence of the ion itself. The field lines bend and, depending on the distance between the charges, a displacement in the transverse coordinate is produced when the electron approaches the ion. The lines in a circle of radius 0.2 µm end on the ion, thus a free electron drifting along those lines recombines and disappears. We define the cross section S CS as the transverse area whose crossing field lines end on one ion. The section should be far enough from the ion such that the ion field is negligible compared to the drift field, and all the lines emerging from the ion cross that section. The total number of field lines emerging from the ion, q/ɛ, is equal to the number of lines traversing the cross section, E d S CS, therefore S CS = q/(ɛe d ), where q is the elementary charge, ɛ the absolute permittivity of the liquid argon and E d the amplitude of the drift field. For a typical E d value of 1 kv/cm, S CS = 1.2 10 1 µm 2 ( S CS = 1.2 10 13 m 2 ) is much larger than the ion dimensions. The total cross section, obtained considering all the ions constantly present within the drift volume can be macroscopic and the effect of the recombination cannot be neglected. As discussed in sec. 2, the expected positive-ion density in steady conditions for a shallow detector is d I 1.7 10 11 m 3, thus the secondary recombination can be significant taking into account a single-phase detector with few meters drifting length. The effect is expected to be even more relevant in case of a dual-phase detector due to ion feedback from the gas, which can increase 4

Figure 3. Expected recombination probability (color scale) as a function of the ion gain G I and drift length in case of a detector like the DUNE double-phase module (L = 12 m and charge amplification), considering E d = 1.0 kv/cm (le f t) and E d = 0.5 kv/cm (right). the d I value further. We introduce the ion gain, G I, defined as the number of positive ions injected into the liquid for each electron extracted. This factor is proportional to the electron amplification G through a constant β (β 1) which takes into account the average loss of the positive charge in the gas, given by the ions scattering onto field lines not ending on the liquid surface, as well as the efficiency to pass the liquid-gas interface. If the amplification factor G I is large enough, the positive-charge density, ρ i, in the liquid can be widely increased by the secondary ions produced by the Townsend avalanche, thus the secondary recombination can be relevant also in case of deep underground detector whose ion density is only given by the 39 Ar decay. The recombination probability calculated for a detector like the DUNE double-phase module [14] is displayed in Fig. 3, considering 1 kv/cm and 0.5 kv/cm effective drift fields. In addition to the charge quenching, a light emission is expected through a mechanism similar to the columnar recombination. The effect can reduce significantly the electron signal increasing the scintillation light, although on timescales which, depending on the drift length and electron velocity, could be of the order of several ms. Depending on the interaction rate in liquid and the detector photon detection efficiency, a constant emission of pulses from the liquid argon bulk could be detected. At 0.5 kv/cm up to 50 % of the electrons created near the cathode are expected to produce a recombination photon along the drift. It is important for a double-phase massive detector with drift of many meters and charge amplification to investigate the ion feedback from the gas, possibly measuring G I. An investigation of this topic is currently carried-out by the CIEMAT and IFAE groups working on the LAr technology. 4 Conclusions Given the much larger velocity of the electrons with respect to the ions, a massive positive-charge density is created in a LAr detector. A finite element analysis considering a detector placed on the Earth surface, whose most important ionization source is yielded by muons, shows that, in 5

steady state, both the electron and negative-ions density are negligible compared to the density of positive ions. This density can be further increased in case of ion feedback from the gas. A relevant recombination probability of the free charges is expected along the drift field lines, quenching the electron signal in large detectors and producing a constant light emission in the LAr bulk. This emission is poorly correlated in space and time to the particle interaction and it depends on the electric drift field and event rate inside the detector. Acknowledgments This research is funded by the Spanish Ministry of Economy and Competitiveness (MINECO) through the grant FPA2015-70657P. The authors are also supported by the Unidad de Excelencia María de Maeztu: CIEMAT - Física de Partículas through the grant MDM-2015-0509. References [1] S. Amerio et al. [ICARUS Collaboration], Design, construction and tests of the ICARUS T600 detector, Nucl. Instrum. Meth. A 527 (2004) 329. [2] A. Rubbia et al. [WA105 Collaboration], Technical Design Report for large-scale neutrino detectors prototyping and phased performance assessment in view of a long-baseline oscillation experiment, CERN-SPSC-2014-013. [3] W. Walkowiak, Drift velocity of free electrons in liquid argon, Nucl. Instr. Meth. A 449 (2000) 288. [4] T.H. Dey, T.J. Lewis, Ion mobility and liquid motion in liquefied argon, J. Phys. D: Applied Physics, vol. 1, n 8, p 1019, (1968). [5] M. Torti Search for space charge effects in the ICARUS T600 LAR-TPC, Poster at the 4th International Conference on New Frontiers in Physics (2015) [6] V. Chepel and H. Araujo, Liquid noble gas detectors for low energy particle physics, JINST 8 (2013) R04001 [arxiv:1207.2292 [physics.ins-det]]. [7] P. Benetti et al. [WARP Collaboration], Measurement of the specific activity of Ar-39 in natural argon, Nucl. Instrum. Meth. A 574 (2007) 83 [astro-ph/0603131]. [8] M. Miyajima, et al., Average energy expended per ion pair in liquid argon, Phys. Rev. A 9 (1974) 1438 [9] P. K. F. Grieder, Cosmic rays at earth: Researcher s reference, manual and data book, Amsterdam: Elsevier (2001), ISBN: 9780444507105. [10] J. Birks, Theory and Practice of Scintillation Counting, Pergamon Press, New York, 1964 [11] R.T. Scalettar et al., Critical test of geminate recombination in liquid argon, Phys. Rev. A 25 (1982) 2419. [12] COMSOL Multiphysics Modeling Software v. 5.3. COMSOL AB, Stockholm, Sweden. [13] L. Romero, R. Santorelli and B. Montes, Dynamics of the ions in Liquid argon Detectors and electron signal quenching, Astropart. Phys. 92 (2017) 11, doi:10.1016/j.astropartphys.2017.04.002 [14] R. Acciarri et al. [DUNE Collaboration], Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) : Volume 1: The LBNF and DUNE Projects, arxiv:1601.05471 [physics.ins-det]. 6