Supplement of A dual-inlet, single detector relaxed eddy accumulation system for long-term measurement of mercury flux

Similar documents
Nicola Bodini et al. Correspondence to: Nicola Bodini

Review of Anemometer Calibration Standards

Automation of the radiochemical procedures for the sequential separation of radionuclides

AE 3051, Lab #16. Investigation of the Ideal Gas State Equation. By: George P. Burdell. Group E3

Multiphase Oscillatory Flow Strategy for in Situ Measurement and Screening of Partition Coefficients

TECHNISCHE UNIVERSITÄT MÜNCHEN. Vacuum (VAK) Group B412. Patrick Christ and Daniel Biedermann

Micromet Methods for Determining Fluxes of Nitrogen Species. Tilden P. Meyers NOAA/ARL Atmospheric Turbulence and Diffusion Division Oak Ridge, TN

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Contents. Efficient synthesis of 5-(chloromethyl)furfural (CMF) from high fructose corn syrup (HFCS) using continuous flow processing

VACUUM PUMPING METHODS

Guidelines for the Selection and Operation of Provers with Micro Motion ELITE Coriolis Flow Meters

Supplement of Multi-wavelength optical measurement to enhance thermal/optical analysis for carbonaceous aerosol

Standard Practices for Air Speed Calibration Testing

Prima PRO Process Mass Spectrometer

Dissolution Automation: Basic Questionnaire.

9. Pumps (compressors & turbines) Partly based on Chapter 10 of the De Nevers textbook.

Lecture 3 Vacuum Science and Technology

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

Characterisation of the Aerosol Collection Module (ACM) Dagmar Trimborn, John Jayne, Thorsten Hohaus

Chemistry Instrumental Analysis Lecture 31. Chem 4631

PoS(PD07)031. General performance of the IceCube detector and the calibration results

SPECIFICATIONS PARTICLE SENSOR KS-28B Higashimotomachi, Kokubunji, Tokyo , Japan

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

HPLC Praktikum Skript

Supporting Information for. Measuring Emissions from Oil and Natural Gas. Well Pads Using the Mobile Flux Plane Technique

in a Walnut Orchard During CHATS

Flow Management Devices, LLC An ISO 9000:2008 Certified Company

Comparing the Microlab 600 to Volumetric Glassware and Air Displacement Pipettes. January 2013

Sudden Expansion Exercise

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

Chemistry Instrumental Analysis Lecture 27. Chem 4631

VOC measurements in ambient air using Selected Ion Flow Tube Mass Spectrometry-automation and calibration considerations

A New On-line Cyanide Analyzer for Measurement of Cyanide in Hydrometallurgical Processing of Precious Metal Ores

TI 226H Calibration of Flow Check Devices using Positive Displacement Flow Meter

Supporting Information for. Suppression of OH Generation from the Photo-Fenton Reaction in the Presence of α-pinene Secondary Organic Aerosol Material

1.0 Reactive Gas Chromatography Design and Setup Procedure for Catalyst Pelletization & Inlet Packing Software and Method.

The following article was authored by Jacques Chaurette, President Fluide Design, Inc. ( All rights reserved.

Process Control & Design

Station Maintenance and Calibration Report ABRAHAM LINCOLN BIRTHPLACE NATIONAL HISTORIC SITE March 13, 2007

Background Statement. This document describes a test method for particle removal performance of nm-rated liquid filters using GNP and OPC.

OAKRIDGE _ NATIONALLABORATORY

MAINTENANCE AND CALIBRATION REPORT NATIONAL PARK SERVICE GASEOUS POLLUTANT MONITORING NETWORK BADLANDS NATIONAL PARK MAY 10, 2006

Windcube TM Pulsed lidar wind profiler Overview of more than 2 years of field experience J.P.Cariou, R. Parmentier, M. Boquet, L.

Supplement of Cloud and aerosol classification for 2.5 years of MAX-DOAS observations in Wuxi (China) and comparison to independent data sets

Experiment (4): Flow measurement

Mercury Stack Monitor SM-4

Product Description and Specification

Amendment to the QAPP/FSP Addendum

PERFORMANCE VERIFICATION IONSCAN LS

IHTC DRAFT MEASUREMENT OF LIQUID FILM THICKNESS IN MICRO TUBE ANNULAR FLOW

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Thermodynamics. Joule-Thomson effect Ideal and Real Gases. What you need: Complete Equipment Set, Manual on CD-ROM included

2d-Laser Cantilever Anemometer

Varian Galaxie Chromatography Data System for Preparative HPLC

Protocol Particle size distribution by centrifugal sedimentation (CPS)

DE '! N0V ?

Thermo Finnigan LTQ. Specifications

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Differential Mobility Particle Sizer (Aerosol measurements)

δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method

Twice-Annual Station Maintenance and Calibration Report BIG BEND NATIONAL PARK February 1, 2012

Determination of Polymer Modifier in Asphalt

Separating Cloud Forming Nuclei from Interstitial Aerosol

WP 1.3. Presentation of this deliverable

Wet plus Dry Deposition of Atmospheric Hg in the SE U.S. NADP Technical Meeting Sept , 2007 Boulder, CO, USA

Supplement of Constraining uncertainties in particle-wall deposition correction during SOA formation in chamber experiments

Heat Exchangers for Condensation and Evaporation Applications Operating in a Low Pressure Atmosphere

Universität Duisburg-Essen Fakultät für Ingenieurwissenschaften WS 2012 Maschinenbau, IVG, Thermodynamik Dr. M. A. Siddiqi

SIMULATION SUITE CHEMCAD SOFTWARE PROCESS CONTROL SYSTEMS PROCESS CONTROL SYSTEMS COURSE WITH CHEMCAD MODELS. Application > Design > Adjustment

Thermodynamics INTRODUCTION AND BASIC CONCEPTS. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Engineering Thermodynamics. Chapter 1. Introductory Concepts and Definition

UNCERTAINTIES FOR PRESSURE-TIME EFFICIENCY MEASUREMENTS

Effect of imprecise lag time and high-frequency attenuation on surface-atmosphere exchange fluxes determined with the relaxed eddy accumulation method

Calibrate Rotameter and Orifice Meter and Explore Reynolds #

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Back to the Basics: NeSSI or Not NeSSI the Basics Are the Same

Solar Flat Plate Thermal Collector

Vapor-Phase Cutting of Carbon Nanotubes Using a Nanomanipulator Platform

Department of Energy Fundamentals Handbook. THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW, Module 3 Fluid Flow

( KS A ) (1) , vapour, vapor (USA) , saturation vapour pressure. , standard reference conditions for gases. , degree of saturation

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Applied Fluid Mechanics

Development of an Automatic Sampling Module to Monitor Concentration of Liquid-Borne Nanoparticles

Recent improvement of the LHD Thomson scattering system

Manual Laser Doppler Anemometry Manual remote experiment Project e-xperimenteren+

Fundamentals of Particle Counting

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

Isobaric Vapor Liquid Equilibria of Systems containing N-Alkanes and Alkoxyethanols

Series tore word. Acknowledgements

Random uncertainties of flux measurements by the eddy covariance technique

Atmospheric Mercury Deposition Modeling

FACULTY OF CHEMICAL & ENERGY ENGINEERING FLUID MECHANICS LABORATORY TITLE OF EXPERIMENT: MINOR LOSSES IN PIPE (E4)

Roll No. :... Invigilator s Signature :.. CS/B.Tech (EIE)/SEM-5/EI-501/ INDUSTRIAL INSTRUMENTATION II

RANGE OF ALPHAS. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

CHAPTER 3 SHELL AND TUBE HEAT EXCHANGER

Thermodynamics: An Engineering Approach Seventh Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, Chapter 7 ENTROPY

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

Discussion Reply to comment by Rannik on A simple method for estimating frequency response corrections for eddy covariance systems. W.J.

Transcription:

Supplement of Atmos. Meas. Tech., 9, 509 524, 2016 http://www.atmos-meas-tech.net/9/509/2016/ doi:10.5194/amt-9-509-2016-supplement Author(s) 2016. CC Attribution 3.0 License. Supplement of A dual-inlet, single detector relaxed eddy accumulation system for long-term measurement of mercury flux S. Osterwalder et al. Correspondence to: S. Osterwalder (stefan.osterwalder@unibas.ch) The copyright of individual parts of the supplement might differ from the CC-BY 3.0 licence.

This supplement consists of a table and 8 figures which complement the main article giving supporting information regarding the following topics: Table S1: To enable reproducibility of the system, the main REA components and their quantity, their manufacturing company, the county of origin and model number is given. The capital letters in the Index column of the table point to the components in Fig. 1 in the main text. Figure. S1: The manual calibration of the Hg detector was done after each measurement campaign in the laboratory in Basel and in situ at Degerö. Repeated injections of a GEM concentration to both air streams, every 30 min, resulted in 8 and 18 data points for each linear regression fit in Basel and Degerö, respectively. Figure S2: Limitations in turbulence mixing were defined applying a turbulence characteristic test (Eq. 8). 6% of the data in Basel and 4% at Degerö were rejected due to insufficient turbulence. The threshold (green dotted lines) is defined as a deviation of 2 from the model. Measurements beyond that point were rejected. Figure S3: The systematic bias in same-air measurements caused by the sampling line offset was corrected for in the Hg 0 flux calculation. The strict rejection criteria allow a maximum standard deviation of the offset of 0.05 and a maximum difference in gold cartridge response of 10%. At both sites gold cartridge-pair 1-3 failed the bias test. In Basel the standard deviation of the offset was too high (Fig S3a, blue line) and at Degerö the difference in the gold cartridge response between C1 and C2 was greater than the defined threshold (Fig S3a, blue line). Figure S4: The substandard performance of cartridge-pair 1-3 was confirmed by plotting the difference between the updraft and downdraft integrated air samples to the updraft air sample. The cartridge-pair 1-3 data (blue dots) scatter considerably more compared to cartridge-pair 2-4 (red dots) indicating a malfunction in a piece of equipment (Teflon Isolation Valves in energized status). Figure S5: The polar histograms show how the 30 min averages of wind speed, GEM concentration and wind direction are distributed at both sites during the campaigns. The polar histograms a) and b) describe the situation in Basel and c) and d) at Degerö. Figure S6: The fast-response valve switching frequency (30 min average) was considerably higher at Degerö (red) compared to Basel (black) indicating the presence of smaller eddies. The switching interval tended to increase with increasing friction velocity. Figure S7: Turbulence regimes have been investigated at both sides. Integral REA flux damping factors dependent on wind speed and stability conditions were derived. The simulation indicates that considerable flux damping in Basel occurs just during unstable conditions and low wind velocities (a). At Degerö, the integral damping factor is considerable during stable conditions and high wind velocities (b). Figure S8: The total REA flux damping factor at average wind speeds at both sites increased with increasing wind speed during stable conditions. In Basel REA flux damping just occurred at very low frequency ranges. 1

Table S1. Most important REA components. They are indexed in the text and in the schematic of the REA system hardware (Fig. 1) with capital letters. Index Quantity Components Manufacturer Country Model number A1 1 Sonic anemometer Metek GER USA-1 A2 1 Sonic anemometer Gill Instruments UK Solent1012R2 B 3 Rocker Solenoid Valves (fast-response) Bürkert Fluid Control Systems GER 6128 + 2507 C 1 LabVIEW 2011 National Instruments USA 22.6.2011 D 100 m PTFE tubing 1/4 VICI AG International SUI JR-T-6810 E 3 0.2 µm PTFE filters Merck Millipore GER SLFG65010 F 6 0.2 µm PTFE filters Pall Corporation USA Acro 50, 4400 G 10 Teflon Isolation Valves N Research USA SH360T041 H 1 Pressure transmitter WIKA GER A-10 I 3 Red-y smart controller GSC Vögtlin Instruments SUI 3214101 J 1 Rotary vane pump Gardner Denver Gmbh GER G 08 K 3 Uniplast boxes Swibox SUI UCP 540/750 L 1 Dynacalibrator VICI AG International SUI 150 M 1 CVAFS Hg Detector TEKRAN Inc. CAN 2500 N 1 Swing piston vacuum pump KNF Neuberger GER NPK 09 DC O 1 Pressure gauge with water trap Servatechnik SUI - P 1 ¼ Hydrocarbon trap Chromatography R.S, Inc. USA 300 Q 20 l Argon gas (purity>99.9997%) Air Liquide S.A. FRA N57 R 1 Hg Vapor Calibration Unit TEKRAN Inc. CAN 2505 S 1 Digital gas-tight syringe Hamilton USA 1700 T 1 Hg Zero-Air Generator TEKRAN Inc. CAN 1100 2

Figure S1. Linear relationship between detected GEM reference gas concentration on each of the four gold cartridges (Area, 1-4) and manually injected GEM [pg] for Basel (a) and Degerö (b). 3

Figure S2. A deviation by more than a factor of 2 from the model (green dotted line) was used as the threshold to reject data measured in Basel (a) and Degerö (b) during periods of insufficient and larger than expected turbulence. 4

Figure S3. Precision in concentration difference measurements of the same GEM concentration between cartridge-pair 1 3 (blue) and 2 4 (red) in Basel (a) and at Degerö (b). 5

Figure S4. Ratio of the difference between the updraft and downdraft integrated air sampling to the updraft signal for both cartridge-pairs during the bias test in Basel (a) and Degerö (b). 6

Figure S5. GEM concentration (A) and wind rose (B) during the Basel campaign and GEM concentration (C) and wind rose (D) during the Degerö campaign. Polar histograms show 30 min averaged GEM concentrations (ng m -3 ) and wind speed (m s -1 ). 7

Figure S6. 30-min averaged switching frequency of fast-response valves (HSV) at Basel (black) and Degerö (red) in relation to friction velocity. 8

Figure S7. Simulated integral damping factors for REA fluxes in Basel (a) and Degerö (b) dependent on wind speed (0-10 m s -1 ) and stability conditions: Unstable (z/l < 0); stable (z/l = 0.1, z/l = 0.5, z/l =1). 9

Figure S8. Modeled original and damped cospectral density and total damping factor (secondary y-axis) of REA system for Basel (a) and Degerö (b) dependent on stable (z/l = +1) and unstable (z/l = -1) conditions and mean horizontal wind speeds for both sites (u = 2.6 and 2.9 m s -1, respectively). 10