Radiation measurements around ESRF beamlines

Similar documents
In vacuum ID beam line shielding commissioning and direct gasbremsstrahlung measurements at Synchrotron SOLEIL

Shielding Design for the Imaging and Medical Beamline at the Australian Synchrotron

Advanced Storage Photon Ring Source Upgrade Project:

Shielding calculations for the design of new Beamlines at ALBA Synchrotron

Bulk shielding design for the MAX IV facility

Vacuum at the ESRF. current activities that benefit from simulation models

Radiological Implications of Top-up Operation at Canadian Light Source: Dose Computations and Measurements at the Vulnerable Points

Radiation Protection Considerations for the Cryogenic In-Vacuum Undulator of the EMIL Project at BESSY

Radiation Protection At Synchrotron Radiation Facilities

Experience on Coupling Correction in the ESRF electron storage ring

Vacuum System of Synchrotron radiation sources

8 th International Workshop on Radiation Safety at Synchrotron Radiation Sources

Gas Bremsstrahlung at the Diamond Light Source. P. Bonner, R. Ryder

RADIATION PROTECTION AT SYNCHROTRON RADIATION FACILITIES* James C. Liu 1 and Vaclav Vylet 2. Abstract

Radiation Protection Issues at SOLARIS - Safety Assumptions and Project Status.

COMMISSIONING AND STATUS OF THE DIAMOND STORAGE RING

Radiation shielding for undulator beamline in Indus-2 synchrotron radiation source

Radiological safety studies for the TeraFERMI beamline at

Collimator Designed for the APS Front End Operating in the Top-up Mode. D. Shu, T. Sanchez, and T. Kuzay

Mechanical Motion Measurement System Design, Initial Results and Experiments with Orbit Feedback

Estimate of Undulator Magnet Damage Due to Beam Finder Wire Measurements

Insertion Devices Lecture 2 Wigglers and Undulators. Jim Clarke ASTeC Daresbury Laboratory

Part E. Radiation monitors. Radiation Safety - JUAS 2014, X. Queralt. Part E. Radiation monitors

SLAC-PUB Submitted to Radiation Protection and Dosimetry. Work supported by Department of Energy contract DE-AC02-76SF00515

Accelerator Design and Construction Progress of TPS Project

Radiation Safety at LCLS: The Photon Beam s Maximum Capability and Material Damage Potential

Simulation Studies for a Polarimeter at the International Linear Collider (ILC)

Occupational Radiation Protection at Accelerator Facilities: Challenges

Developments for the FEL user facility

Radiation Safety Considerations for the TPS Accelerators

The HERA ep Interaction Regions Learned Lessons

Accelerator Upgrade Problem

H4IRRAD generic simulation results

2.6 Electron transport lines

Status Report on the Survey and Alignment efforts at DESY

Overordnet Plan for Drift for ASTRID2

THE GSI FUTURE PROJECT: AN INTERNATIONAL ACCELERATOR FACILITY FOR BEAMS OF IONS AND ANTIPROTONS

Upstream Polarimetry with 4-Magnet Chicane

Accelerator Facility Accident Report

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

The Radiation Monitor PANDORA (LB 6419) at PETRA III

4.2 Photon Beam Line Systems

Comparison of FLUKA and STAC8 for shielding calculations of the hard X-ray line of the LCLS

Design, construction and characterization of a portable irradiator to calibrate installed ambient dose equivalent monitors

Research with Synchrotron Radiation. Part I

Introduction to Accelerator Physics

ThomX Machine Advisory Committee. (LAL Orsay, March ) Ring Beam Dynamics

MAGNET INSTALLATION AND ALIGNMENT FOR THE FUJI TEST BEAM LINE AT KEKB

Fundamentals of Accelerators

First propositions of a lattice for the future upgrade of SOLEIL. A. Nadji On behalf of the Accelerators and Engineering Division

Comparison of the brilliance limit between MAX IV 3 GeV ring and NSLS II low beta straights using the same undulator technique

PERSPECTIVES OF PERSONNEL EXTERNAL DOSIMETRY AT STANFORD LINEAR ACCELERATOR CENTER

Vacuum Science and Technology in Accelerators

Part V Undulators for Free Electron Lasers

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Radiation field inside the tunnel of the Linear Collider TESLA

CesrTA Status Report Mark Palmer for the CesrTA Collaboration March 4, 2009 ESR

Radiation Protection Considerations *

COST MP0601 Short Wavelength Laboratory Sources

High Intensity Operation and Control of Beam Losses in a Cyclotron based Accelerator

Monte Carlo Simulations of Synchrotron Radiation and Vacuum Performance of the MAX IV Light Sources

Accelerator Vacuum Technology Challenges for Next-Generation Synchrotron-Light Sources

Radiation Shielding of Extraction Absorbers for a Fermilab Photoinjector

NEW ARRANGEMENT OF COLLIMATORS OF J-PARC MAIN RING

FLUKA Calculations for the Shielding Design of the SPPS Project at SLAC*

Detailed Design Report

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. II - Synchrotron Radiation - Malcolm J. Cooper

Survey Meter OD-01 Address: Phone: Fax: URL:

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

Introduction to Synchrotron Radiation

arxiv: v1 [physics.acc-ph] 1 Apr 2015

PREPARING THE SPS COMPLEX ALIGNMENT FOR FUTURE LHC RUNS

Synchrotron Facilities And Free Electron Lasers. Introduction

Radiation Safety Assessment of the CLS Beamlines Using FLUKA Monte-Carlo Code

On-axis injection into small dynamic aperture

Accelerator Physics. Accelerator Development

STATUS REPORT ON STORAGE RING REALIGNMENT AT SLRI

Beam loss background and collimator design in CEPC double ring scheme

05/11/2013. Nuclear Fuel Cycle Ionizing radiation. Typical decay energies. Radiation with energy > 100 ev. Ionize an atom < 15eV

THE SPEAR3 UPGRADE PROJECT AT SLAC *

Estimation of Radioactivity and Residual Gamma-ray Dose around a Collimator at 3-GeV Proton Synchrotron Ring of J-PARC Facility

3. Synchrotrons. Synchrotron Basics

The low Q 2 chicane and Compton polarimeter at the JLab EIC

THE ACTIVE PERSONNEL DOSIMETER - APFEL ENTERPRISES SUPERHEATED DROP DETECTOR*

Free-electron laser SACLA and its basic. Yuji Otake, on behalf of the members of XFEL R&D division RIKEN SPring-8 Center

arxiv:hep-ex/ v1 31 Dec 2001

LCLS Accelerator Parameters and Tolerances for Low Charge Operations

Boster Synchrotron COMMISSIONING RESULTS LINAC. Storage Ring. Proceedings of IPAC2011, San Sebastián, Spain

seminar: MAX IV laboratory vacuum systems

SURVEY AND ALIGNMENT FOR THE SYNCHROTRON LIGHT SOURCE ELETTRA

Higgs Factory Magnet Protection and Machine-Detector Interface

TRAINING IN EXTERNAL DOSIMETRY CALCULATIONS WITH COMPUTATIONAL CODES

Study of Distributed Ion-Pumps in CESR 1

Measurements of Radiation Doses Induced by High Intensity Laser between and W/cm 2 onto Solid Targets in LCLS MEC Instrument

Measurements of Radiation Doses Induced by High Intensity Laser between and W/cm 2 onto Solid Targets at LCLS MEC Instrument

Radiation Protection Dosimetry (2006), Vol. 118, No. 3, pp Advance Access publication 6 October 2005

Vacuum and mechanical design of ILC DR

Impedance and Collective Effects in Future Light Sources. Karl Bane FLS2010 Workshop 1 March 2010

Experience from the LEP Vacuum System

Research Physicist Field of Nuclear physics and Detector physics. Developing detector for radiation fields around particle accelerators using:

Transcription:

Radiation measurements around ESRF beamlines P. Berkvens & P. Colomp European Synchrotron Radiation Facility Abstract Over the last 2 years radiation levels around a number of beamlines have been continuously recorded, essentially to evaluate the vacuum conditioning of newly installed vacuum vessels or in-vacuum undulators in the corresponding straight sections of the storage ring. Scattered bremsstrahlung measurements were done using PTW 5 litre ionisation chambers, and some neutron measurements have been carried out using Apfel superheated drop detectors. A number of measurements have been done inside the optics hutch of the Machine/Safety diagnostics beamline, measuring the gas-bremsstrahlung intensity on axis with a small Farmer-type ionisation chamber. A number of relevant results are presented. The radiation levels inside and outside the beamlines are compared with readings from the beam loss ionisation chambers inside the storage ring. This allows a qualitative estimation of the relative contribution of gas bremsstrahlung to the dose levels around the beamlines compared to other, non-vacuum induced beam losses. Finally, radiation levels outside the beamlines are compared with those outside the storage ring. 1. Introduction The complete upgrade of the shielding of the optics hutches at the ESRF has been completed. The reasons for this upgrade were in the first place the new European legislation concerning radiation protection, and the upgrade of the storage ring with the installation of ID vacuum vessels with reduced vertical aperture. With the new European legislation the annual dose limits for non-exposed people is reduced from 5 msv to 1 msv. All people working at the ESRF are considered as non-exposed, and we want to maintain this policy with the reduced legal limits. On the other hand, increased vacuum pressures inside the reduced aperture ID vessels had caused a significant increase of bremsstrahlung radiation inside the beamlines. It was therefore necessary to improve the shielding of the optics hutches of the beamlines. Two solutions have been used: either the thickness of the sidewalls has been increased to 3 mm of lead, or the freeway next to the hutch has been integrated in the interlocked and searched area to increase the minimum distance a person could approach the hutch. In the mean time a significant R&D program on the ID vacuum vessels has also led to a dramatic improvement of the vacuum inside the straight sections, essentially due to the development of NEG coatings in these vessels. The upgrade of the shielding and the improvement of the vacuum vessel technology have resulted in a situation where, after a minimum period of vacuum conditioning, beamlines can operate within these new legal requirements. Nevertheless the radiation levels outside the optics hutches of ID beamlines are still essentially determined by the vacuum conditions in the straight sections. We will illustrate this with a number of radiation measurements carried out over the last two years.

2. Example 1: dose measurements outside the ID9 beamline A series of measurements have been made during 22 around the ID9 optics hutch. An in-vacuum undulator has been installed in the straight section of cell 9 at the beginning of the year. Due to technical problems it was removed during the 3 rd run of 22, and replaced by a straight vacuum vessel. Finally, the in-vacuum undulator was reinstalled for the 4 th run. We measured the evolution of the dose rate outside the optics hutch throughout this period, to follow the vacuum conditioning of the newly installed undulator, the replacement vacuum vessel, and the reconditioning of the undulator after its reinstallation. The upgrade of the shielding of ID9 was done by interlocking the freeway next to the optics hutch. The radiation measurements were done with a PTW 5 litre ionisation chamber, placed inside the interlocked freeway. This explains why the measured dose rates are temporarily higher than the.5 µsv h -1 derived limit for non-exposed workers, the area being inaccessible to people during operation. In figure 1, as an example, we show the measured dose rates outside the ID9 optics hutch and the stored beam pattern during the first month of the 4 th run of 22, following the reinstallation of the in-vacuum undulator. One notices a clear decrease in the measured dose rates, due to the vacuum conditioning of the straight section. The spikes that are measured on the dose rate correspond to vacuum bursts. When the front end is closed, or when there is no beam in the storage ring, a background dose rate of.9 µsv h -1 is measured. dose rate ( Sv.h -1 ) 1..9.8.7.6.5.4.3.2.1. 5 1 15 2 25 3 days since 22/8/2 2 15 1 5 Figure 1: Measured dose rates outside the ID9 optics hutch (blue) and stored beam pattern (red) during the first month of the 4 th run of 22, following the reinstallation of the in-vacuum undulator. The relation between the measured dose rates and the vacuum conditioning is clearly illustrated in figure 2, where for the same period we show the measured net dose rates,

and the product of stored beam times the pressure in the straight section, the gas bremsstrahlung being proportional to the latter product. Since we do not know the exact value of the average pressure in the straight section we have used the pressure reading of the first penning gauge of cell 9, situated at the beginning of the 5 m ID free space. From figure 2 we see that at the beginning of the run the vacuum conditioning goes faster than the pressure reading from this gauge would indicate. dose rate ( Sv.h -1 ) 1..9.8.7.6.5.4.3.2.1. 5 1 15 2 25 3 days since 22/8/2 1.E-6 9.E-7 8.E-7 7.E-7 6.E-7 5.E-7 4.E-7 3.E-7 2.E-7 1.E-7.E+ I x P (ma.mbar) Figure 2: Measured dose rates outside the ID9 optics hutch (blue) and the product of the stored beam times the pressure reading from the first penning gauge (red). At a given time, the pressure in the straight section will be proportional to the stored current, since the vacuum is dominated by synchrotron radiation induced outgassing. The dose rate will therefore be proportional to the square of the stored beam. The conditioning itself is done by the synchrotron radiation, and depends therefore on the stored beam. The vacuum conditioning of a straight section is therefore best shown by plotting the normalised measured net dose rates, i.e. the net dose rate divided by the square of the stored beam, as a function of the integrated electron dose, i.e. the integral of the stored current with time. The results of the measurements during the 1 st, 3 rd and 4 th run of 22 are presented in this way in figure 3. On a log-log scale, the normalised dose rate versus integrated electron dose is roughly a straight line, its slope indicating how fast the conditioning goes. The steps that are visible during this conditioning are due to the different filling patterns, since the dynamic pressure depends on the filling pattern.

1.E-4 Sv.h -1.mA -2 1.E-5 1.E-6 1 1 integrated e - dose (A.h) Figure 3: Normalised net dose rates measured outside the ID9 optics hutch versus integrated electron dose, during the first run (blue), third run (green) and fourth run (red) of 22. 3. Example 2: bremsstrahlung measurements inside the ID6 optics hutch 1.E-1 25 9.E-2 dose rate (Gy.h -1 ) 8.E-2 7.E-2 6.E-2 5.E-2 4.E-2 3.E-2 2.E-2 1.E-2.E+ 2 15 1 5 5 1 15 2 25 3 35 4 45 5 time (days since 23/8/2) Figure 4: Measured on-axis dose rates inside the ID6 optics hutch (red) and the stored beam (blue) during the 4 th run of 22. New ID vacuum vessels are installed in the straight section of cell 6, corresponding to the Machine/Safety diagnostics beamline. A.6 cm 3 ionisation chamber, placed on-

axis, allows us to do (relative) bremsstrahlung measurements to follow the vacuum conditioning of the new vessel. During these measurements the gaps of the ID6 undulators are completely open. The ionisation chamber is shielded with 3 mm of lead to eliminate the upstream and downstream dipole synchrotron radiation. Figure 4 shows the measured dose rates during the 4 th run of 22, following the installation of a new 5 m long, 8 mm internal height, NEG coated stainless steel vessel. Note that at the end of the run, the front end of ID6 stayed open during the top-ups. Figure 5 shows the normalized dose rates versus integrated electron dose, showing a steady conditioning. 1.E-5 Sv.h -1.mA -2 1.E-6 1.E-7 1 1 integrated e - dose (A.h) Figure 5: Normalised dose rates measured inside the ID6 optics hutch versus integrated electron dose, during the fourth run of 22. 4. Comparison between the vacuum and non-vacuum contributions to dose rates outside an optics hutch Scattered bremsstrahlung measured around beamlines will be essentially due to gasbremsstrahlung produced in the corresponding straight section. However, bremsstrahlung originating from other electron interactions can also enter the beamlines, for instance bremsstrahlung produced by electron lost on the small gap ID vacuum vessels or in-vacuum undulators. At the ESRF the dose rates outside the beamlines are fortunately much less sensitive to this type of non-vacuum beam losses, in the sense that the same amount of electrons lost will cause much smaller dose rates. We will illustrate this with a typical measurement carried out on ID9. A closer look at the dose rates measured with the unidos beam loss monitors inside the storage ring and the dose rates measured outside the optics hutch allows a comparison between the vacuum and non-vacuum contributions to the dose rates outside the beamlines. Figure 6 compares the dose rates measured inside cell 9 and outside the optics hutch of ID9, during a refill and a consequent gap change of the invacuum undulator. Initially the gap is at 1 mm, and with this wide gap the beam

losses inside cell 9 are essentially due to vacuum. The beam loss monitor inside cell 9 reads.85 µsv h -1 at 168 ma and.12 µsv h -1 at 2 ma, respectively before and after the top-up, corresponding to a vacuum-induced dose rate of 3. 1-6 µsv h -1 ma -2. The ionisation chamber outside the optics hutch reads.3 µsv h -1 at 168 ma and.41 µsv h -1 at 2 ma, respectively before and after the top-up, corresponding to a vacuum-induced dose rate of 1.5 1-5 µsv h -1 ma -2. We obtain a factor of 3.5 between the dose rates outside the hutch and inside the storage ring. After the gap change from 1 mm to 6.25 mm, the dose rate inside the storage ring increases with 1.13 µsv h -1, whereas outside the optics hutch the increase is only.27 µsv h -1. For these non-vacuum induced beam losses, we obtain therefore a factor of.24 between the dose rates outside the hutch and inside the storage ring. In this case the dose rates outside the optics hutch would be 15 times less sensitive to non-vacuum beam losses compared to vacuum induced beam losses. 1.5.4.41.27 outside OH ( Sv.h -1 ).3.2.1.3 1.13 1.5 inside SR ( Sv.h -1 ) ma.85 2 2 ma 168 ma 15.12 15 1 5 17.5 17.6 17.7 17.8 17.9 18 days since 18/1/2 gap (mm) Figure 6: Comparison between vacuum and non-vacuum contributions to radiation outside the ID9 optics hutch: net dose rate outside optics hutch (blue, top), dose rate inside storage ring (red, top), stored beam (blue, bottom) and in-vacuum undulator gap (red, bottom). Figure 7 shows the beam lifetime during the same period. The stepwise reductions in the lifetime are due to the interactions between the electron beam and the laser of the high-energy backward Compton scattering beamline (Graal). One notices, as was also discussed in reference [1], that the gap change does not alter the overall lifetime, but rather redistributes the local losses. The lifetime at 19 ma is 6 h, corresponding to a total beam loss of 8.8 1-4 ma s -1 beam loss. The vacuum induced dose rate inside cell 9 corresponds to.18 µsv h -1, corresponding to a beam loss of 1.19 1-5. ma s -1 when using the conversion factor of 1.1 1-4 ma s -1 ( µsv h -1 ) -1 obtained in reference

[1] for the unidos beam loss monitors. The vacuum induced losses in cell 9 would therefore account for 1.35 % of the total losses. With the gap closed at 6.5 mm, an extra local beam loss of 1.24 1-4 ma s -1 is created in cell 9, raising the total local losses in cell 9 to 15 % of the total beam losses. 2 15 17.5 17.6 17.7 17.8 17.9 18 days since 18/1/2 9 8 7 6 5 4 3 2 1 lifetime (h) / gap (mm) Figure 7: Stored beam (blue), lifetime (red) and ID9 in-vacuum undulator gap (green) during top-up and gap change. 5. Comparison between photon and neutron dose rates outside the beamlines We have made a number of dose measurements outside the beamlines the compare the photon dose rates with neutron dose rates. Neutrons measured outside the beamlines are essentially produced by bremsstrahlung photons inside the optics hutches. A first example is shown in figure 8. The photon dose behind the sidewall of the ID9 optics hutch was measured using a PTW 5 litre ionisation chamber and a Siemens EPD electronic dosimeter. The net integrated ambient dose equivalent is shown in the figure. The neutron dose was measured using two Apfel REMbrandt monitors, and the integrated ambient dose equivalent values are shown. We see that good agreement is found between the two photon measurements, and we see that the neutron dose is about a factor of two higher than the net photon dose. The zero increase in the integrated dose values in the middle of the period is due to the fact that the front end remained closed for several days. A second example is shown in figure 9, concerning dose measurements outside the ID31 optics hutch. The photon dose was measured using Siemens EPD electronic dosimeters. One monitor was placed behind the 3 mm thick lead sidewall and one monitor was placed behind the 5 mm thick lead backwall. The net ambient dose equivalent H*(1) is shown in the figure. Two Apfel REMbrandt monitors were placed in the same positions.

photon dose ( Sv) 175 15 125 1 75 5 25 photon (PTW 5 l) photon (siemens EPD) neutron id9-1 neutron id9-3 35 3 25 2 15 1 5 neutron dose ( Sv) 25 2 15 1 5 5 1 15 2 25 3 35 days since 3/6/2 Figure 8: operation. Neutron and photon dose outside the ID9 optics hutch during 5 weeks of 5 dose ( Sv) 4 3 2 photon sidewall photon backwall neutron sidewall neutron backwall 1 25 2 15 1 5 2 4 6 8 1 12 14 16 18 2 days since 23/1/1 Figure 9: Neutron and photon doses measured behind the side wall and back wall of the ID31 optics hutch during 3 weeks of operation.

The integrated ambient dose equivalent values are shown in figure 9. We see that in this case the photon and neutron doses on the sidewall are essentially identical, whereas on the backwall the neutron dose is about a factor of two smaller than the photon dose. 6. Comparison between dose rates around beamlines and dose rates around the storage ring tunnel It is interesting to compare dose rates outside the beamlines with dose rates outside the storage ring. During the last run of 21 we measured photon dose rates simultaneously outside the ID31 optics hutch and on the roof of the storage ring tunnel above the corresponding straight section. The location chosen for the measurement on the storage ring tunnel roof corresponds to the position where the highest dose rates are measured along the given unit cell. Both measurements were done using PTW 5 l ionisation chambers. Outside the ID31 beamline the neutron dose rate is roughly equal to the photon dose rate (see figure 9), and previous radiation measurements showed a similar situation behind the concrete shield of the storage ring. Figure 1 shows the net photon dose rate measured outside the beamline, during a few days of typical 16-bunch operation, while figure 11 shows the net photon dose rate measured on the storage ring roof, for the same period. We see that the dose rates outside the beamline are about six times higher than the dose rates outside the storage ring. During stored beam conditions, the main dose constraint will therefore come from the beamlines. dose rate ( Sv.h -1 ).1 1.9.8 75.7.6.5 5.4.3 25.2.1. 4. 4.5 5. 5.5 6. 6.5 time (days) Figure 1: Photon dose rate outside the ID31 optics hutch (blue) and stored beam pattern (red) during 16-bunch operation. During user operation the dose constraints at the ESRF will therefore primarily come from the beamlines. Outside the storage ring however, the integrated dose will come essentially from the accelerator studies. This is illustrated in figure 12, where the net

integrated photon dose measured on the storage ring roof above cell 31 is shown, for the first run of 22. We see indeed that the major part of the dose is integrated during the initial start-up period after the winter shutdown, and during the weekly machine study days during the run..14 1 dose rate ( Sv.h -1 ).12.1.8.6.4.2 75 5 25. 4. 4.5 5. 5.5 6. 6.5 time (days) Figure 11: Photon dose rate above storage ring roof (blue) and stored beam pattern (red) during 16-bunch operation. 5 25 net integrated dose ( Sv) 4 3 2 1 2 15 1 5 1 2 3 4 days since 18/1/2 Figure 12: Net integrated photon dose above storage ring roof (blue) and stored beam pattern (red) during the 1 st run of 22. 7. Summary The upgrade of the shielding of the optics hutches of the ID beamlines at the ESRF, together with the improved vacuum conditions in the straight section, due to the NEG coating of the 5 m long ID vacuum vessels, allow the operation of these beamlines, while respecting the new European radiation protection regulations. New ID vacuum

vessels are characterised on the Machine/Safety diagnostics beamline using on-axis bremsstrahlung measurements. Afterwards, a minimum of reconditioning of the vacuum vessel on the actual straight section is required before the beamline can operate. Despite the improved vacuum conditions in the storage ring straight sections, photon dose measurements outside the beamlines show that dose rates are essentially determined by scattered gas-bremsstrahlung. Neutron dose rates outside the optics hutches can no longer be neglected, due to the reduction of photon dose rates with the increased lead thickness of the hutch walls. Therefore, if in the future a further shielding upgrade would be necessary, neutron shielding should be considered. Finally, during user operation the main dose constraints will come from the beamlines, rather than from the storage ring, where machine studies cause the major contribution to the integrated dose. References [1] P. Berkvens & P. Colomp, Measurements of radiation levels inside the ESRF storage ring