FLOW SENSOR FOR LIQUID MEDIA Serie 210

Similar documents
Flow sensor for liquid media type 210

Flow sensor for liquid media type 230

OEM Flow sensor for liquid media type 200

OEM Flow sensor for liquid media type 200

OEM Flow sensor for liquid media type 200

OEM Flow sensor type 235 for liquid media

Flow sensor type 236 for liquid media

Pressure transmitters for industrial applications MBS 32 and MBS 33

Relative pressure transmitter type 520

ED 701 General Industry Pressure Transmitter

Conductivity sensor for hygienic applications

Direct-operated 2/2-way compact solenoid valves Type EV210A

Industrial Pressure Transmitter

Direct-operated 2/2-way solenoid valves Type EV210B

Industrial Pressure Transmitter

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Solenoid valves 2/2-way direct-operated type EV210A

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

E8EB-N0C2B E8EB-N0B2B

Linear measuring technology

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

RoHS. Versatile. X g. X 2 e

Pressure Measurement Single-range transmitters for general applications

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

PRODUCT CATALOGUE PREssURE switch

Pressure Transmitter ED 701

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Operating Instructions for Digital Manometer. Model: MAN-SD

Absolute encoders multiturn

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Single point load cells

Imformation of C091D series

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

VOLUMEC. Valve Position Indicator 5

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

Vortex Flow Meters. RVL Series Vortex Flow Meter

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

BMXART0814 analog input module M340-8 inputs - temperature

Surface-mounting Thermostats ATH Type Series

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

ISEmax CAM40/CAS40. Technical Information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Field IT 50T Series Transmitters

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

331 Low & Medium Pressure filters

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

Cartridge Valves Technical Information. Quick reference

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

AC axial compact fan

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Pressure. 1 Fitting PA R - N R2

Thermal-Magnetic Circuit Breaker 2210-S2..

MINIATURE MICROSWITCHES - PREMIUM

Thermal-Magnetic Circuit Breaker 2210-S2..

Surface-mounting thermostats Series ATH

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

AC axial compact fan

Thermal-Magnetic Circuit Breaker 2210-S2..

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

ISEmax CAS40D. Technical Information

Installation guide 862 MIT / MIR

Impedance relay and protection assemblies

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

Load Washers. Force kn until kn. Type 9101A A

Calio-Therm NC Type Series Booklet

Electromagnetic Flowmeter

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

BMXART0814 analog input module M340-8 inputs - temperature

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

2-way proportional throttle valve for block installation

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

387 Low & Medium Pressure filters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

all stainless steel transducer multimedia compatibility

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Transcription:

FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available with an increased range of power supply and output signals all with and without temperature measurement. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy. Flow measuring with voltage, current or frequency output Temperature non-sensitive measuring principle Excellent media resistance (measuring element not in contact with the media) CE conformity Wide application temperature range Marginal loss of pressure Measuring element not sensitive to debris Direct temperature measurement in the medium Drinking water approval KTW, W70, WRAS

Technical overview Flow measurement Measuring principle Vortex Piezoelectric sensor element Measuring range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Accuracy at < 0% fs (water) < % fs Accuracy at > 0% fs (water) < % measuring value Response time Immediately Signal delay < 00 ms Frequency output Therefore suitable for spigot use. Response time < ms Signal delay < s Analogue output Response time < 00 ms Temperature measurement (> 8 DN - DN 6 on request) Measuring principle Resistance PT000 Measuring range -0... + ÀC PT000 @ T = 0 ÀC μ 0. K Accuracy class B D EN 607 @ T 0 ÀC μ 0. K μ 0.00 * T Measuring range -... + ÀC Accuracy μ 0. K μ 0.00 * T 0... 0 V T (ÀC) = +0 ÀC Calculation temperature 0 V * UOUT_T - ÀC Temperature influences Self-heating at temperature sensor K/mW Conduction resistance to connector 0.8 Ohm Operating conditions Medium Suitable for heating circuit water with the usual additives Drinking water Other medium on request Media < + ÀC Temperature Ambient -... +8 ÀC Storage -0... +8 ÀC (for lifetime) bar at +0 ÀC (for lifetime) 6 bar at +00 ÀC Max. pressure and (for 600 hours) bar at + ÀC medium temperature (for hours) bar at +0 ÀC (max. test pressure) 8 bar at +0 ÀC Cavitation The following equation is valid to prevent cavitation: P abs outlet / P difference >. Materials in contact with medium (FDA-conform) Sensor paddle Case with damming body Sealing material ETFE PA6T/6I (0% GF) EPDM (perox.) Electrical overview Frequency output Voltage output Current output Power supply U.7... VDC.... VDC 8... VDC Output Frequency square pulse signal UOUT_Q_frequency < 0.... > U - 0. V Flow (Q) Analogue signal U OUT_Q oder I OUT 0... 0 V... 0 ma Output Resistant signal R OUT PT000 PT000 class B D EN 607 temperature (T) Voltage signal U OUT_T 0... 0 V Electrical connection and protection class Mx (IP 6) Mx (IP 6) Mx (IP 6) Load agianst or < ma / < 00 nf < 6 ma / < 00 nf ) < (U - 8 V) / 0 ma Current consumption load free (I ) < ma < ma Weight DN 6 / 8 DN 0 DN DN 0 DN ~ 7 g ~ 7 g ~ 68 g ~ 9 g ~ 00 g Test / Admissions Drinking water approval KTW / W70 / WRAS Electromagnetic compatibility CE conformity acc. to EN 66-- Packaging (multiple packaging) Connection copper tube Outside thread K Outside thread G DN 6 Blister 0x Blsiter 0x DN 8 / 0 Blister 0x Blister 0x Blister 0x DN Blister 0x Blister 0x Blister 0x DN 0 Blister 0x Blister 0x Blister x DN Blister x Blister x ) against only ) incl. xdi inlet and outlet side ) Pv in Pa; Q in l/min

Nominal diameters dependent variables Nominal diameters DN 6 Connection Outside thread heavy Measuring range Quantity per puls Flow range Characteristic line frequency output Frequency range Characteristic line voltage outout Characteristic line current output Pressure drop ), ) 0.... 0 l/min 0.86 ml 0.07....7 m/s 0.08 * f - 0. 8... 7 Hz Q =.0 * U OUT_Q Q = 0.6 * (l - ma) 0 * Q 0.68 ml 0.098 * f - 0. 0... 8 Hz DN 8 Outside thread heavy 0.9... l/min 0.6 ml 0.....0 m/s 0.09 * f - 0. 0... 88 Hz Connection copper tube 0.6 ml 0.08 * f - 0.... 99 Hz Q =. * U OUT_Q Q = 0.98 * (l - ma) 8.00 * Q.99 ml 0.080 * f - 0.... 79 Hz DN 0 Outside thread heavy.8... l/min.70 ml 0.6....76 m/s 0.08 * f - 0.... 87 Hz Connection copper tube.8 ml 0.08 * f - 0.... 8 Hz Q =. * U OUT_Q Q =.000 * (l - ma).0 * Q.0 ml 0.080 * f - 0. 6... 7 Hz DN 0 Outside thread heavy.0... 0 l/min.7 ml 0.9....89 m/s 0.08 * f - 0. 6... 8 Hz Connection copper tube.88 ml 0.08 * f - 0. 6... 78 Hz Q =.0 * U OUT_Q Q =.00 * (l - ma).0 * Q.07 ml 0.8 * f - 0. 0... 7 Hz DN Outside thread heavy.... 0 l/min.06 ml 0.90.... m/s 0.8 * f - 0. 0... 7 Hz Connection copper tube.077 ml 0.86 * f - 0. 0... 70 Hz Q =.0 * U OUT_Q Q =. * (l - ma) 6.70* Q 6. ml 0.7 * f - 0.... 7 Hz DN 0 Outside thread heavy.0... 8 l/min 6. ml 0.6....09 m/s 0.70 * f - 0.... 0 Hz Connection copper tube 6.08 ml 0.7 * f - 0.... 7 Hz Q = 8. * U OUT_Q Q =. * (l - ma).0 * Q DN. ml 0.767 * f - 0.... 0 Hz 9.0... 0 l/min 0.8....709 m/s Outside thread heavy. ml 0.770 * f - 0.... 0 Hz Q = * U OUT_Q Q = 9.7 * (l - ma) 0.9 * Q Minimum life span on high flow rate and high temperature Temperature in ÀC Temperatur in C 0 0 0 0 00 9 90 8 80 7 70 6 60 0 0 60 80 00 0 0 Durchfluss Flow in % in % Std hours 0 hours Std 00 hours Std 0. year Jahr Jahr year 0 year Jahre ) incl. xdi inlet and outlet side ) Pv in Pa; Q in l/min

Order code selection table 0. X X X X X X X Version Flow 9 Flow and temperature (PT000) 8 Flow and temperature (0... 0 V) 6 Nominal diameters and DN 6 0.... 0 l/min. 9 0 6 K,G flow range DN 8 0.9... l/min. 0 8 DN 0.8... l/min. 0 DN 0.0... 0 l/min. DN.... 0 l/min. DN 0.0... 8 l/min. 0 DN 9.0... 0 l/min. K,G Output / power supply Frequency output (Square pulse signal).7... VDC 8,9 Analogue signal 0... 0 V.... VDC Analogue signal... 0 ma 8... VDC 8,9 Electrical connection Connector Mx - or -pole (condensation protection) 9 Connector Mx - or -pole (condensation protection) 8,6 Sealing material EPDM Ethylene propylene rubber (peroxidically cross-linked) Tube connection Plastic PA6T / 6I connection copper tube (max. DN 0) N Plastic PA6T / 6I outside thread K (see dimension diagram) K Plastic PA6T / 6I outside thread G (see dimension diagram) G Accessories ) Order number Connection kit ) DN 8, 0 with copper tube 77 Connection kit ) DN 8, 0 with adapter Rp ⅜ Stainless steel.0/aisi 0 776 Connection kit ) DN with copper tube 777 Connection kit ) DN with adapter Rp ½ Stainless steel.0/aisi 0 778 Connection kit ) DN 0 with copper tube 779 Connection kit ) DN 0 with adapter Rp ¾ Stainless steel.0/aisi 0 780 Straight-wire box for connector Mx with cable -pole 00 cm 60 Corner-wire box for connector Mx with cable -pole 00 cm 60 Straight-wire box for connector Mx with cable -pole 00 cm (with temperature) 6 Corner-wire box for connector Mx with cable -pole 00 cm (with temperature) 6 Straight-wire box for connector Mx screwing terminal -pole 0 Clip for DN 8,0 6 Clip for DN 09 Clip for DN 0 O-Ring for DN 8, DN 0 EPDM Œ.9 x.6 Copper tube and adapter O-Ring for DN EPDM Œ 7.86 x.6 Copper tube and adapter 6 O-Ring for DN 0 EPDM Œ.89 x.6 Copper tube and adapter 7 O-Ring for DN EPDM Œ x (as a replacement, already assembled) 79 Connection copper tube for DN 8, 0 L=0 mm Connection copper tube for DN L=0 mm Connection copper tube for DN 0 L=0 mm 06 Adapter for DN 8 und DN 0 Rp ⅜ Stainless steel.0/aisi 0 6 Adapter for DN Rp ½ Stainless steel.0/aisi 0 660 Adapter for DN 0 Rp ¾ Stainless steel.0/aisi 0 66 ) Accessories supplied loose ) Connection set includes: x Clip, x Copper tubes or Adapter and x O-Ring

Dimension diagram DN 6, 8, 0,, 0, d 6d d d d d d d d d d 6d DN6 K.7.0 G ½ 77 DN6 G 8..7 G ¾ 86 DN8 K.7.0 G ½ 77 d DN8 G 8..7 G ¾ 86 DN0 K.0. G ½ 8 9 DN0 G 9.. G ¾ 90 9 DN K 6.6 6. G ¾ 87 6 DN G.6 9. G 97 6 DN0 K 6.6 6. G 0 0 7 DN0 G.6 6.8 G ¼ 7 0 7 DN K 0.0 68. G ¼ 0 6 DN G 6.0 7. G ½ 6 Dimension diagram DN 8, 0,, 0 a a a a a a a a a a 6a 6a DN8 9. 9.0.9 7 0. 8.9 DN0. 7..9 77 0. 8.9 DN. 6. 9.0 8 0..0 DN0 9. 66..0 0 0. 7.

Admissible locking torque DN6/8/0 G ½ DN6/8/0 G ¾ DN G ¾ DN G DN0 G DN0 G ¼ DN G ¼ DN G ½ M min [Nm]... M max [Nm] Accessories DN 8, 0,, 0 adapter.0 c inside thread clip c o-ring to adapter c c 7c 6c c 8c 9c c c c c c 6c 7c 8c 9c DN8 DN0 DN DN0 0 Rp ⅜ D 999 lenght min. 9 Rp ⅜ D 999 lenght min. 9 Rp ½ D 999 length min.. Rp ¾ D 999 lenght min..0 9 7.6.6. 6.00 0.8.0 9 9.6 7.. 6.00 0.8 6. 67.0 0.0 8.0.8. 8. 8 8. 8.8 8.0 8.00. Geometry of customers connection tube DN 8, 0,, 0 o-ring b clip 6b b b bevelled edge min. 0. b 7b b 8b 9b b b b b b 6b 7b 8b 9b DN8 Œ.9x6 μ 0. 8.9 μ 0. Œ μ 0. Œ.00 μ 0.08 Œ 8.88 μ 0.. 6.00 0.8 DN0 Œ.9x6 μ 0. 8.9 μ 0. Œ μ0. Œ.00 μ 0.08 Œ 8.88 μ 0.. 6.00 0.8 DN DN0 Œ 7.86x.6 μ 0. 8.9 μ 0. Œ 6 μ 0. Œ 8.00 + 0.08-0.06 Œ.89x.6 μ 0..9 μ 0. Œ 0 μ 0. Œ.00 + 0.08-0.06 Œ.8 μ 0. 8.0.8. Œ.8 μ 0. 8.0 8.00.

Tube mounting instructions Consider the following to ensure the correct function of the sensor. Only diameter changes from large to small are allowed. Avoid repeated elbows in the same level at entryside minimum xdn for alternative elbows minimum 0.xDN for recommended 90À elbow with min. R.8xDN Electrical connection Connector Mx without temperature measurement OUT Hz Frequency output current output A V OUT voltage output OUT Q Pin Colour brown blue black brown white blue black gray Connector Mx with temperature measurement A T Ω T Hz T Ω T T Ω T OUT OUT Q V OUT T OUT Q V V frequency output with PT000 current output with PT000 voltage output with PT000 voltage output with temperature output 0...0 V

Influence of glycol With the following definitions we are able to correct the influence of media with higher viscosity than water (= media viscosity >.8 cst) in order to reach a measuring accuracy of % fs in the range of.8 - cst and of % in the range of - cst ( = viscosity in cst). Definition of viscosity of glycol-water-compound Kinematic Kinematische Viskosität Ethylenglykol Wasser viscosity ethylene glycol water Kinematic Kinematische Viskosität Propylenglykol Wasser viscosity propylene glycol water 60 60 Temperature Temperatur in C ÀC 0 0 0 0 0% 0% 0% 0% 0% 0% 60% 70% Temperature Temperatur in C ÀC 0 0 0 0 0% 0% 0% 0% 0% 0% 60% 0 0 0 6 7 8 9 0 viscosity Viskosität in cst in 0 6 7 8 9 0 viscosity Viskosität in cst in Definition of respond threshold Q min Definition of characteristic line formula Q = k * f - Q 0 Minimal detektierbarer Durchfluss detectable flow Einfluss der Viskosität auf Q Influence on viscocity Q0 0 Minimaler Durchfluss in l/min flow l/min 0 0 DN0 DN DN0 DN characteristic Q0 in Kennlinienformel in l/min line formula 0 8 6 DN0 DN DN0 DN 0 6 7 8 9 0 viscosity Viskosität in cst in 0 6 7 8 9 0 viscosity Viskosität in cst in Formula respond threshold Q min in l/min < DN 0 not possible DN 0: Q min = υ + 0.8 DN : Q min = υ +. DN 0: Q min = υ +.0 DN : Q min = υ + 6.0 Formula characteristic line for Q > Q min in l/min < DN 0 not possible Frequency output: DN0: Q = 0.08 * f 0.0υ + 0.0 DN: Q = 0.8 * f 0.υ + 0. DN0: Q = 0.7 * f 0.υ + 0. DN: Q = 0.767 * f 0.80υ + 0.60 Voltage output 0...0 V DN0: Q =. * UOut 0.0υ + 0.0 DN: Q =.0 * UOut 0.υ + 0. DN0: Q = 8. * UOut 0.υ + 0. DN: Q =.0 * UOut 0.80υ + 0.80 Current output... 0 ma (I in ma) DN0: Q =.000 * (I ma) - 0.0υ + 0.0 DN: Q =. * (I ma) - 0.υ + 0. DN0: Q =. * (I ma) - 0.υ + 0. DN: Q = 9.7 * (I ma) - 0.80υ + 0.80