ORP Probe ORP. Reads. +/-2000mV. Range. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C. Temperature range C.

Similar documents
ORP Probe. Mini ORP. Reads. +/-2000mV. Range SMA. Connector. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

ph Probe ReallyEasyData com

Understanding ph Troubleshooting and Diagnostic information

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

GENERAL INSTRUCTIONS GENERAL PREPARATION

OPERATING INSTRUCTIONS

COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL

FOCUS: Water Pollkon Prevention and Control

Guide to ph Analysis.

GENERAL INSTRUCTIONS GENERAL PREPARATION

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

All about ph! Is it as simple as it seems? The ph Workshop. Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

6 Acid Base Titration

1) A ph/mv meter or an ion meter, either line operated or portable.

STANDARD OPERATING PROCEDURE

Rapid RH Portable ph Meter. User's Manual

Differential ph Probe Type 18

symphony Multisensor Probes

Bante210 Benchtop ph Meter Instruction Manual

Use a pipet bulb when pipeting cyanide solutions, as these solutions are highly toxic.

COLE-PARMER INDUSTRIAL CALCIUM ION ELECTRODE INSTRUCTION MANUAL

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

Chemistry MultiMeasure Sensor PS-2170

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background

Combination ph, ORP, T Electrode with Transmitter

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA

Manual ph Probe & Oxidation Reduction Potential Probe Models 6528A and 6528B

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

ph Probes Lab vs. Process Care, Calibrations and Comparison Presented by: Michael Blackburn Technical Sales Specialist at Hach Company

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Ion Selective Electrode Probe

ph 5 Meter Manual The LaMotte 5 Series

Free Chlorine Amperometric 4-20mA Sensors

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

[Agilent Technologies] [Electrochemistry Products] Quick Reference

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

PH700 Benchtop ph Meter Instruction Manual

symphony Reference Electrodes

Operating Instructions for Ammonium ISE Specifications

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

Experiment #10: Analysis of Antacids

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

GENERAL INSTRUCTIONS GENERAL PREPARATION

Experimental Procedure. Lab 406

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

User instructions. Gel filled ORP/Redox electrode: Model MTC10101, MTC10103, MTC10105, MTC10110, MTC10115 or MTC10130

experiment7 Explaining the difference between analyte and standard solutions. Know the definition of equivalence point.

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

NaOH (aq) + HCl (aq) NaCl (aq) + H 2 O (l)

Module 2. Measurement Systems. Version 2 EE IIT, Kharagpur 1

Frequently asked question about our new Platinum Water Ionizer

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

ELECTROCHEMICAL CELLS

Conductivity of Electrolytes in Solution

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

ELECTROCHEMICAL CELLS

Single Replacement Reactions

Lab #3 ph and Buffers

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

ELECTROCHEMICAL CELLS

COLE-PARMER INDUSTRIAL SILVER/SULFIDE ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL

INE-DDB-303A Portable Conductivity Meter Instruction Manual

Electrodes for ph measurements. - when you need to be sure...

To determine relative oxidizing and reducing strengths of a series of metals and ions.

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Drinking water is allowed to contain up to 1.3 parts per million of copper (by mass) and be considered safe. What does parts per million (ppm) mean?

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Electrochemistry - Theory and Practice

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

phoenix Electrode Company CARBON DIOXIDE GAS-SENSING ELECTRODE INSTRUCTION MANUAL 1. A ph/mv meter or an ion meter, either line operated or portable.

POTASSIUM ION SELECTIVE ELECTRODE

Chemistry 212 Lab, Spring Design of the Experiment: Standard and Non-Standard Reduction Potentials For Metal/Metal Ion Half-Cells

Name: Chemistry 103 Laboratory University of Massachusetts Boston HEATS OF REACTION PRELAB ASSIGNMENT

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

MassWWP Standard Operating Procedure L-6 ph and Alkalinity Rev.0 Page 1 of 12

Application Your benefits

The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate in aqueous solutions.

DIFFUSION THROUGH MEMBRANES STANDARDS B C.4 INTRODUCTION

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

How Can We Determine the Actual Percentage of H 2 O 2 in a Drugstore Bottle of Hydrogen Peroxide?

ACID-BASE TITRATION (MICROSCALE)

COLE-PARMER LABORATORY CUPRIC ION ELECTRODE INSTRUCTION MANUAL

Transcription:

V 2.7 Revised 11/8/17 ORP Probe Reads Range Response time Max pressure Max depth Temperature range C Cable length Internal temperature sensor Time before recalibration Life expectancy Maintenance ORP +/-2000mV 95% in 1s 100 PSI 60m (197 ft) 1 80 C 1 meter N/ ~1 Year 2 Years + N/

Specifications Cable Length 1m (3.2 ) Max depth Cable length Weight Speed of response Dimensions NC connector Sterilization 60m (197 ft) 1 meter 44 grams 95% in 1 second 12mm x 150mm (0.5" x 6") Yes Chemical only 30mm (1.18 ) Typical pplications Standard lab use Field use Soil Low ionic and ultra-pure water Strong reducing agents Samples containing heavy metals Hydroponics / aquaponics eer, wine and other liquor Food safe 150mm (6 ) 120mm (4.7 ) This ORP probe can be fully submerged in fresh or salt water, up to the NC connector indefinitely. Sensing area 15.55mm (0.61 ) 12mm (0.47 ) Ø 14.3mm Ø 2.85mm Soaker bottle 2 Copyright tlas Scientific LLC

Operating principle ORP stands for oxidation/reduction potential. Oxidation is the loss of electrons and reduction is the gain of electrons. The output of the probe is represented in millivolts and can be positive or negative. Just like a ph probe measures hydrogen ion activity in a liquid; an ORP probe measures electron activity in a liquid. The ORP readings represents how strongly electrons are transferred to or from substances in a liquid. Keeping in mind that the readings do not indicate the amount of electrons available for transfer. ph Probe ORP Probe 3 Copyright tlas Scientific LLC

When reading the ORP of a liquid that has very few electronics available for transfer ORP readings can appear to be inconsistent. The water is unreactive and has only trace amounts of electron movement. These readings are equivalent to the readings you see with an unconnected multimeter. -234.6 Reading 24.2 Reading 606.9 Reading 605.3 Reading Tap water Tap water dd just a drop of bleach (which is an oxidizing agent) n ORP probe has a platinum tip that is connected to a silver wire, surrounded by silver chloride. That silver wire is then connected to a KCL reference solution. ecause platinum is an unreactive metal it can silently observe the electron activity of the liquid without becoming apart of whatever reaction is occurring in the liquid. Platinum tip Silver chloride Silver wire Reference wire KCL reference solution 4 Copyright tlas Scientific LLC

n ORP probe is a passive device that detects a current generated from the oxidation or reduction chemical substances in water. This current (which can be positive or negative) is very weak and cannot be detected with a multimeter, or an analog to digital converter. How often do you need to recalibrate an ORP probe? ecause every use case is different, there is no set schedule for recalibration. If you are using your probe in a fish tank, a hydroponic system or any environment that has generally weak levels of chemical reactions you will only need to recalibrate your probe once per year for the first 2 years. fter that every ~6 months. If you are using the ORP probe in batch chemical manufacturing, industrial process, or in a solution that is known to have strong chemical reactions, then calibration should be done monthly or in extreme cases after each batch. 5 Copyright tlas Scientific LLC

NEVER EXTEND THE CLE WITH CHEP JUMPER WIRES! C D E 1 5 10 15 20 C D E F G H I J 1 5 15 15 20 F G H I J DO NOT CUT THE PROE CLE WITHOUT REFERING TO THIS DOCUMENT! 6 Copyright tlas Scientific LLC

DO NOT MKE YOUR OWN UNSHIELDED CLES! C D E 1 5 10 15 20 C D E F G H I J 1 5 15 15 20 F G H I J ONLY USE SHIELDED CLES. REFER TO THIS DOCUMENT! 7 Copyright tlas Scientific LLC

Extending the probe cable length You can extend the cable to greater than 100 meters with no loss of signal. tlas Scientific has tested up to 300 meters without a problem, however you run the risk of turning your ORP probe into an antennae, picking up noise along the length of your cable. If you want to extend your cable, we recommend that you use proper isolation, such as the asic EZO TM Inline Voltage Isolator, or Tentacle Shield. e sure to calibrate your probe with the extended cable. Extending a probe cable can be easily done with our NC Extension Cable. Simply connect the NC end of the probe to the Extension cable, and you are all set. If you need to water proof a NC connection, we highly recommend using a product like Coax-Seal to safely cover and prevent any water damage that may occur. Water proof 8 Copyright tlas Scientific LLC

Helpful operating tips ORP probes must stay wet and cannot be allowed to dry out, this is why every ORP probe is shipped in a plastic soaker bottle containing ORP probe storage solution. The probe should remain in the bottle until it is used. If the probe is used infrequently, the bottle and its solution should be saved and the probe stored inside. 1 Take out the probe by loosening the cap of the soaker bottle by turning it counter clockwise, and pulling the probe out. Slide the O-ring and the cap off the probe. Ready to use 2 Vigorously stir the probe in the sample, calibration solution, or rinse solution. This action will bring solution to the probes surface quicker and improve the speed of response. Response time 9 Copyright tlas Scientific LLC

Probe cleaning Coating of the ORP bulb can lead to erroneous readings including shortened span. The type of coating will determine the cleaning technique. Soft coatings can be removed by vigorous stirring or by the use of a squirt bottle. Organic chemical, or hard coatings, should be chemically removed. light bleach solution or even a 5 10% hydrochloric acid (HCl) soak for a few minutes, often removes many coatings. Do not use abrasive materials on the ORP probe. 10 Copyright tlas Scientific LLC