NUCLEAR TRANSMUTATION IN DEUTERED PD FILMS IRRADIATED BY AN UV LASER

Similar documents
Analysis By Time-Of-Flight Secondary Ion Mass Spectroscopy or Nuclear Products In Hydrogen Penetration Through Palladium

Fig.1 Pyrex glass cell

TRITIUM PRODUCTION IN PALLADIUM DEUTERIDE/HYDRIDE IN EVACUATED CHAMBER

DETECTION OF ANOMALOUS ELEMENTS, X-RAY AND EXCESS HEAT INDUCED BY CONTINUOUS DIFFUSION OF DEUTERIUM THROUGH MULTI-LAYER CATHODE (Pd/CaO/Pd)

Figure 1: Two pressure shocks causing the sample temperature increase (Termocouple Tc1, figure 1b of reference [2]). 2 Heat production Apart from the

Hydrogen Embrittlement,, Microcracking, and Piezonuclear Fission Reactions at the Ni and Pd Electrodes of Electrolysis Cold. Fusion Experiments

NUCLEAR PRODUCTS IN A GAS-LOADIND D/PD AND H/PD SYSTEM

Analysis of Nuclear Transmutation Induced from Metal Plus Multibody-Fusion-Products Reaction

Surface Analysis of hydrogen loaded nickel alloys

Yasuhiro Iwamura, Takehiko Itoh, Nobuaki Gotoh and Ichiro Toyoda

Replication Of MHI Transmutation Experiment By D 2 Gas Permeation Through Pd Complex

Palladium fission triggered by polyneutrons

Low Energy Nuclear Fusion Reactions in Solids

Photon and particle emission, heat production and surface transformation in Ni-H system

SEARCH FOR COHERENT DEUTERON FUSION BY BEAM AND ELECTROLYSIS EXPERIMENTS

Plasmonic Hot Hole Generation by Interband Transition in Gold-Polyaniline

X-RAY EMISSION DURING ELECTROLYSIS OF LIGHT WATER ON PALLADIUM AND NICKEL THIN FILMS

OBSERVATION OF SURFACE DISTRIBUTION OF PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY DURING D 2 GAS PERMEATION THROUGH PD COMPLEXES

Search for Nuclear Reaction Products in Gas Phase Experiments - Deuterium Permeation and Absorption -

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

How to Cause Nuclear Reactions at Low Energy and Why Should You Care

CATHODE MATERIAL CHANGE AFTER DEUTERIUM GLOW DISCHARGE EXPERIMENTS

In-vessel Tritium Inventory in ITER Evaluated by Deuterium Retention of Carbon Dust

Thin Pd Film : 400A CaO and Pd Layers :1000A Bulk Pd : 0.1mm

Anomalous Heat Generation in Charging of Pd Powders with High Density Hydrogen Isotopes (I) Results of absorption experiments using Pd powders

SUPER-ABSORPTION CORRELATION BETWEEN DEUTERIUM FLUX AND EXCESS HEAT

Observation of Nuclear Transmutation Reactions induced by D 2

THE PRECURSOR OF "COLD FUSION" PHENOMENON IN DEUTERIUM/ SOLID SYSTEMS

Experimental Evidence for LENR in a Polarized Pd/D Lattice

Very High Third-Order Nonlinear Optical Activities of Intrazeolite PbS Quantum Dots. Supporting Information

Teflon lid. O ring. Catalyst. Catalyst Chamber. Electrolyte (H 2 SO 4 + de-ionized H 2 0)

Comparison of nanosecond laser ablation at 1064 and 308 nm wavelength

MICRO-TOMOGRAPHY AND X-RAY ANALYSIS OF GEOLOGICAL SAMPLES

Alternate Interpretation of the Original Fleischmann and Pons Experiments

Experimental Evidence for LENR in a Polarized Pd/D Lattice

The 46g BGO bolometer

Investigation of anomalous heat production in Ni-H systems

CORRELATED MEASUREMENTS OF D 2 LOADING AND 4 He PRODUCTION IN Pd LATTICE

Enhanced Tc Superconductivity and Anomalous Nuclear Emissions in YBCO and Palladium

Transmutation Reaction Induced by Deuterium Permeation Through Nanostructured Multi-layer Thin Film

Light-Induced Atom Desorption in Alkali Vapor Cells

Clusters with Picometer Distance of Deuterons and LENR

NEUTRINO DINEUTRON REACTIONS (LOW-ENERGY NUCLEAR REACTIONS INDUCED BY D 2 GAS PERMEATION THROUGH PD COMPLEXES. Y. IWAMURA EFFECT)

EMISSION REGISTRATION ON FILMS DURING GLOW DISCHARGE EXPERIMENTS

THE PRECURSOR OF "COLD FUSION" PHENOMENON IN DEUTERIUM/ SOLID SYSTEMS

SIMULATION OF LASER INDUCED NUCLEAR REACTIONS

SPAWAR Systems Center-Pacific Pd:D Co-Deposition Research: Overview of Refereed LENR Publications

Pulsed Laser Deposition; laser ablation. Final apresentation for TPPM Diogo Canavarro, MEFT

AMS MEASUREMENTS OF DEUTERIUM CAPTURED IN TUNGSTEN LAYERS DEPOSITED BY MAGNETRON SPUTTERING

DEVELOPMENT OF A COMBUSTION SYSTEM FOR LIQUID OR GAS SAMPLES

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

ANALYSIS OF NUCLEAR TRANSMUTATION INDUCED FROM METAL PLUS MULTIBODY-FUSION- PRODUCTS REACTION

Deuterium Gas Charging Experiments with Pd Powders for Excess Heat Evolution (II) Discussions on Experimental Results and Underlying Physics

Supporting Information:

Overview of X-Ray Fluorescence Analysis

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

Anomalous production of gaseous 4 He at the inside of DScathode during D 2 O-electrolysis

Spin-resolved photoelectron spectroscopy

Supporting Information s for

EXCESS HEAT AND UNEXPECTED ELEMENTS FROM AQUEOUS ELECTROLYSIS WITH TITANIUM AND PALLADIUM CATHODES

Clusters with Picometer Distance of Deuterons and LENR

D) g. 2. In which pair do the particles have approximately the same mass?

A.DE NINNO, A. FRATTOLILLO, A. RIZZO. ENEA C.R. Frascati,Via E. Fermi 45, Frascati (Rome), Italy E. DEL GIUDICE

Reproduction of Fleischmann and Pons experiments

1 EX/P4-8. Hydrogen Concentration of Co-deposited Carbon Films Produced in the Vicinity of Local Island Divertor in Large Helical Device

Nuclear product ratio for glow discharge in deuterium

Scaling during shadowing growth of isolated nanocolumns

k T m 8 B P m k T M T

OBSERVATION OF NUCLEAR TRANSMUTATION REACTIONS INDUCED BY D 2 GAS PERMEATION THROUGH PD COMPLEXES

Industrial Applications of Ultrafast Lasers: From Photomask Repair to Device Physics

A simple calorimetric method to avoid artifacts in a controversial field: the ice calorimeter

ELEMENTAL ANALYSIS OF PALLADIUM ELECTRODES AFTER PD/PD LIGHT WATER CRITICAL ELECTROLYSIS

FINE PATTERN ETCHING OF SILICON USING SR-ASSISTED IONIZATION OF CF4 GAS

Magnetoresistance Oscillations in Thin Inclined Magnetic Films

A Project for High Fluence 14 MeV Neutron Source

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

NUCLEAR EMISSIONS FROM TITANIUM HYDRIDE/DEUTERIDE INDUCED BY POWERFUL PICOSECOND LASER BEAM

EXCESS HEAT AND HEAT AFTER DEATH IN A GAS- LOADING HYDROGEN/PALLADIUM SYSTEM

RIPPLE FORMATION ON InP SURFACE IRRADIATED WITH FEMTOSECOND LASER

SURFACE STUDIES AFTER LOADING METALS WITH HYDROGEN AND/OR. DEUTERIUM J. Dash and D.S. Silver. Portland, Oregon

SUPPLEMENTARY INFORMATION

Nuclear Transmutation Reaction Occurring during. The Light Water Electrolysis on Pd Electrode.

2

Supplementary Information. Formation of porous SnS nanoplate networks from solution and their application in hybrid solar cells

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

DETECTION OF ANOMALOUS ELEMENTS, X-RAY, AND EXCESS HEAT IN A D 2 -Pd SYSTEM AND ITS INTERPRETATION BY THE ELECTRON-INDUCED NUCLEAR REACTION MODEL

PROCESS MONITORING OF PLASMA ELECTROLYTIC OXIDATION J.-W. Liaw, C.-C. Hsiao, Clinton Fong, Y.-L. Tsai, S.-C. Chung, Oleg Demin Materials Research

Supplementary Figure 1 Detailed illustration on the fabrication process of templatestripped

Synthesis Of A Copper Like Compound From Nickel And Hydrogen And Of A Chromium Like Compound From Calcium And Deuterium

Planning and preparation approaches for non-nuclear waste disposal

Instantaneous reduction of graphene oxide at room temperature

Analysis of Nickel - Hydrogen Isotope System on T

AUTORADIOGRAPHY OF DEUTERATED Ti AND Pd TARGETS FOR SPATIALLY RESOLVED DETECTION OF TRITIUM PRODUCED BY COLD FUSION

Nanoporous metals by dealloying multicomponent metallic glasses. Chen * Institute for Materials Research, Tohoku University, Sendai , Japan

SUPPLEMENTARY MATERIALS FOR PHONON TRANSMISSION COEFFICIENTS AT SOLID INTERFACES

The Emergence of a Coherent Explanation for Anomalies Observed in D/Pd and H/Pd Systems; Evidence for 4 He and 3 He Production

Reinterpreting the Results of the Fleischmann and Pons Cold Fusion Experiments

Laser matter interaction

2008,, Jan 7 All-Paid US-Japan Winter School on New Functionalities in Glass. Controlling Light with Nonlinear Optical Glasses and Plasmonic Glasses

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

Transcription:

Castellano, et al. Nuclear Transmutation in Deutered Pd Films Irradiated by an UV Laser. in 8th International Conference on Cold Fusion. 2000. Lerici (La Spezia), Italy: Italian Physical Society, Bologna, Italy. NUCLEAR TRANSMUTATION IN DEUTERED PD FILMS IRRADIATED BY AN UV LASER Castellano a, M. Di Giulio a M. Dinescu b, V. Nassisi, A. Conte and P.P. Pompa. Department of Physics, University of Lecce, I.N.F.N., C.P. 193, 73100 Lecce-I. Tel. 832 320495 Fax. 832 320505 E-Mail Nassisi@le.infn.it a) Department of Material Science, INFM b) IFA, NELPRP, PO Box MG-16, RO 76 900, Bucharest V, Romania ABSTRACT Nuclear transmutation results in palladium films loaded with deuterium gas and processed by an excimer laser are reported. Vacuum evaporation was utilised to obtain palladium films on Si wafers. The films were inserted in chambers with deuterium gas at a variable pressure up to 5 bar. During the UV laser processing the maximum irradiating energy density was lower than 50 mj/cm in order to avoid the ablation of the palladium films. The samples were analysed by a scanning electron microscope and an electron probe microanalyzer. After the experiments, we found that the Pd films was modified. They presented many cracks and bubbles with very sharp edges. In the bubbles the transmutation of elements was observed. INTRODUCTION In the past, experiments were performed in Applied Electronics Laboratory of Lecce University devoted to investigate the "cold fusion" phenomenon as a potential new energy source [l]. Later on, we concentrated our attention upon nuclei transmutation which seemed to be either a reproducible phenomenon or an interesting result of nuclear physics. Several "cold fusion" experimental results have reported the generation of new elements by Pd nuclei transmutation utilizing Pd samples as bulk and films [2-5]. The elements found out by the EDX microanalysis on the samples used in the first experiments were at first attributed to contamination, as no particular care had been made for the samples preparation before putting them inside the chambers. In this work, in order to exclude the contamination and to study the effect of the transmutation, the chambers have been accurately prepared and the samples were obtained by evaporating palladium on Si wafers. In this way, depositing Pd film of different thickness, we wanted to study the transmutation of elements as a function of the Pd film thickness and of the D 2 pressure. Gas loading was also accurately carried out in order to reduce contamination. Measurements of X and gamma emission and other particles have been also performed by other authors [6, 7]. We studied also the transmutation of elements versus the Pd film thickness and the D 2 pressure applied during the loading process. The maximum new element density was found on the film of greatest thickness. EXPERIMENTAL APPARATUS We realized the films by thermal evaporation of palladium wire (99.95% purity) from a W boat on Si (100) wafers as substrate. The evaporating chamber was evacuated by a diffusion pump up to a residual pressure below 1 10-5 Pa. At about 1 cm below the substrates a sliding mask was placed. In this way, during the deposition the mask was moved in order to deposit films of three different thickness in the same deposition run. The substrates were cut and their area was about 1 cm. They were cleaned by an ultrasonic bath in acetone. The reaction chambers were stainless steel cylinders having an internal diameter of 4 cm and a length of 20 cm. Before performing the experiments, the chambers were accurately washed with acetone and fluxed with nitrogen. Two quartz windows were placed at the two extremities of each chamber to allow the inside access for the UV laser beam. They were evacuated by means of a turbomolecular vacuum pump and filled with deuterium from gas bottles. Laser processing was performed after injecting D 2 gas inside the chamber. The laser utilized was a home made XeCl excimer laser (λ= 308 nm) [8]. The UV light favors multiphoton

absorption processes, which localize the gas atoms within the Pd host crystal [9]. The laser beam was led into the chamber after the D 2 loading process by a focalizing lens (L) and a set of neutral density filters. The experimental apparatus is shown in Fig. 1. The laser energy density was varied by changing the lens position and the neutral density filter. Fig.l: Experimental setup for laser irradiation. C: Loading chamber; ND: Neutral density filters; T: Target, W: windows; G: Pressure Gauge. EXPERIMENTAL RESULTS AND DISCUSSION Utilizing the evaporating device described above, we produced Pd films of 16, 35, 50, 83, 90, 106, 125 and 141nm on silicon wafers. The thickness was measured by a Tencor Alpha Step 200 stylus profilometer with an accuracy of about 5%. One or two samples were placed inside of each chamber, where the pressure of the deuterium was raised to 2.4 or 5 bar. After one week of D 2 loading some samples were irradiated with laser in order to create layers and to localize the gas atoms inside the palladium. Laser fluence was very low to avoid palladium ablation. Thicker films were irradiated with 50 mj/cm 2, while lower energy densities were applied to Pd films having a lower thickness. The irradiation consisted in 400 shots at a laser repetition rate of 1 Hz and the process was repeated 4 times weekly. The total laser shots applied were 1600. A few samples were closed in a chamber and taken into contact with air. After about 5 weeks the chambers were open and the samples were analyzed by a scanning electron microscope (SEM) and by an Energy Dispersive X ray Spectroscopy (EDX) for studying the surface morphological aspect and the chemical composition. All samples processed with D 2 shown many cracks and bubbles with very sharp edges while the samples taken into contact with air did not present any morphological modification. This points out that the D 2 concentration is the cause of the morphological modification. The cracks found were distributed over the whole area and the distance among the bubbles, whose external dimensions were about 2 µm, increased as the film thickness increased. Generally the bubbles were created near to the cracks, see Fig. 2. This result indicates that the formation of the bubbles is tied to the formation of the cracks. The EDX spectrum recorded on the bubble presented many new elements: Sn, Ag, Na, Mg, S, Cl, K, Fe, Ni, Zn, Al, P, Ca, La, Ce, Cr, Ga, F, Ti and Cu. Considering only the elements having a concentration higher than 5% we plotted the number of elements found as a function of the Pd thickness, as Fig. 3 shows. One can see that the number of elements increases as the film thickness increases. There are four films showing a big number of elements (Table 1) and the maximum was obtained with the sample loaded with 2.4 bar and without laser action (case A) and with the sample loaded with 5 bar and processed with laser beam (case D).

Fig. 2: SEM micrograph of a modified Pd film. Fig. 3: New element number as a function of the Pd film thickness loaded with palladium. A) sample loaded with 2.4 bar; B) sample loaded with 2.4 bar and processed with laser, C) sample loaded with 5 bar and D) sample loaded with 5 bar and processed with laser. Case A no laser action Case B laser action Case C no laser action Case D laser action Film thickness D 2 pressure New elements 125 nm 2.4 bar Fe, Ni, Zn, Na, Mg, Al, P, S, Ca, Cl, K, La, Ce, Cr. 125 nm 2.4 bar 141 nm 5.0 bar 106 nm 5.0 bar Na, Mg, Al, P, S, Cl, Ca, Ga. Na; Al, S, Cl, K, Ca, Fe, Ga. Na, Al, S, Cl, K, Ca, Fe, Ni, Zn, Cu, Sn. Table 1. Global results related to A, B, C and D cases.

It is possible to suppose that these results are due to nuclear transmutations and they could be provoked by phonons and plasmons generated inside the crystal [10,11]. In the A case the deuterium concentration is low and it can induce low energy phonons, while in the D case the deuterium concentration is high and as a consequence high energy phonons could be formed. These last two conditions allow to get many elements in the film. Fig. 4a and 4d show the element concentration on atomic number of the elements found on sample A and D, respectively. The elements found are centered at 15, 28 and 58 atomic number for A case and 20, 28 and 50 atomic number for the D case. These two cases present a high element concentration. Fig. 4b and 4c show the element concentration on atomic number of the elements found on sample B and C, respectively. The elements found are centered at 13, 20 and 31 atomic number for B case and 11, 17, 20 and 26 atomic number for the C case. These last two cases present a low concentration likely due to a lower phonon and plasmon energy the low deuterium loading. Fig. 4a: Plot of the percentage of the elements found in the bubbles as a function of the atomic number. Data related to A case. Fig. 4b: Plot of the percentage of the elements found in the bubbles as a function of the atomic number. Data related to B case.

Fig. 4c: Plot of the percentage of the elements found in the bubbles as a function of the atomic number. Data related to C case. Fig. 4d: Plot of the percentage of the elements found in the bubbles as a function of the atomic number. Data related to D case. We performed measurements on Pd films taken into contact with air. These samples did not present transmutation of elements and the surface conductivity was lower than the one of the film loaded with deuterium. REFERENCES 1. V. Nassisi, Transmutation of elements in saturated palladium hydrides by an XeCl excimer laser, Fusion Technology 33, 468-475(1998). 2. G. Miley, Nuclear reaction in palladium hydrogen system, Proc. of n International Low Energy Nuclear Reaction Conference, (1996) 3. T. Mizuno, Reaction products induced by isotopic changes of electrolysis, Infinite Energy, 4, 9, (1996) 4. G. Miley, Product characteristics and energetics in thin-film electrolysis experiments, Proceedings of VII International Conference on Cold Fusion, 241 (1998) 5. S.Z. Wang et Al., The evidence of nuclear transmutation phenomena in Pd-H system using NAA (Neutron Activation Analysis), Proceedings of YE International Conference on Cold Fusion, 259 (1998). 6. Y. Iwamura, T. Itoy, N. Gotoh and I. Toyod., Detection of anomalous elements, X ray, and excess heat in a D 2 -Pd system and its interpretation by the electron induced nuclear reaction model, Fusion-Technology, 4, 476 (1998) 7. S. Focardi et al., Neutron emission in Ni-H systems, II Nuovo Cimento, Vol.112 A, N. 9, pp.921-930 (1999).

8. V. Nassisi, Experimental Studies of a XeCl Laser with UVPreionization Perpendicular and Parallel to the Electrode Surfaces; Appl. Phys. B 53, 14 (1991). 9. T.Sugii, T. Ito and H. Ishikawa, Excimer laser enhanced nidridation of silicon substrates, Appl. Phis. Lett., 45, 966 (1984). 10. G. Stoppini, Nuclear processes in hydrogen loaded metals, Fusion Technology, 34, 81 (1998). 11. F.Frisone, Probability of deuteron-plasmon fusion at room temperature within microcracks of crystalline lattices with deuterium loading, (These Proceedings).