Practical Semi-Adiabatic Calorimetry for Concrete Mixture Evaluation

Similar documents
Impact of Water Reducers and Superplasticizers on the Hydration of Portland Cement

Temperature Measurements in the Production of Quality Concrete

CHEMICAL ADMIXTURES FOR CONCRETE

Lignopolymer Superplasticizers for Alternative Supplementary Cementitious Materials

TA Instruments TAM AIR

Lecture 13 Portland Cement Based Paste Systems

TA Instruments TAM AIR

Fly ash. Pozzolan. Project sponsored by Texas Department of Transportation (TX )

Prevention of the quality of cement from chemical and mineralogical parameters of the clinker

CALMETRIX INC. I-CAL 8000 ISOTHERMAL CALORIMETER FOR CONCRETE AND CEMENT USER MANUAL

INFLUENCE OF SILICA COLLOID ON RHEOLOGY OF CEMENT PASTE WITH SUPERPLASTICIZER

CHAPTER 4 STATISTICAL MODELS FOR STRENGTH USING SPSS

Performance of Concrete Containing Zeolite As a Supplementary Cementitious Material

COMPARISONS OF LINEAR REGRESSION MODELS FOR PROPERTIES OF ALKALI- ACTIVATED BINDER CONCRETE

Thermal Analysis of Composite Cements

The development of a new method for the proportioning of high-performance concrete mixtures

The Rheological and Mechanical Properties of Self-Compacting Concrete with High Calcium Fly Ash

Effect of Natural Zeolite as Partial Replacement of Portland Cement on Concrete Properties

Influence of various acids on the physico mechanical properties of pozzolanic cement mortars

Available online at ScienceDirect. Procedia Materials Science 11 (2015 )

The release mechanism of hexavalent chromium Matteo Magistri, Davide Padovani Mapei S.p.A.

Chapter 2 Concrete with Recycled Aggregates: Experimental Investigations

Heat can be thought of as the flow of energy between two bodies because of a difference in temperature

SHRINKAGE EIGENSTRESSES AND HARDENING OF CONCRETE

THE INFLUENCE OF PROPERTIES AND CONTENT CEMENT PASTE S ON RHEOLOGY OF SELF-COMPACTING HIGH PERFORMANCE CONCRETES

Impact of some parameters on rheological properties of cement paste in combination with PCE-based Plasticizers

Nondestructive Monitoring of Setting and Hardening of Portland Cement Mortar with Sonic Methods

Modeling Heat and Moisture Transport During Hydration of Cement-Based Materials in Semi- Adiabatic Conditions

Effect of different molarities of Sodium Hydroxide solution on the Strength of Geopolymer concrete

MODELING OF HYDRATION OF PORTLAND CEMENTS INCORPORATING SUPPLEMENTARY CEMENTING MATERIALS

Haleh Azari, Ph.D. AASHTO Materials Reference Laboratory (AMRL) AASHTO Subcommittee on Materials Meeting August 2007

Ecofriendly Concrete by Partial Replacement of Cement by Zeolite

USING OF ULTRASONIC PULSE METHOD FOR PREDICTION OF STRENGTH OF BLENDED CEMENTS

Influence of superplasticizers on rheological behaviour of fresh cement mortars

Haleh Azari, Ph.D. AASHTO Materials Reference Laboratory HSOM Meeting, Aug. 2008

Non-Destructive Electrical Methods to Determine the Quality of Concrete

AIR BUBBLE STABILITY MECHANISM OF AIR-ENTRAINING ADMIXTURES AND AIR VOID ANALYSIS OF HARDENED CONCRETE

CONCRETE IN THE MIDDLE EAST

I. Chemical Reactions that Involve Heat

CIVE 2700: Civil Engineering Materials Fall Lab 2: Concrete. Ayebabomo Dambo

Microwave heating on cement-pozzolan pastes: Dielectric permittivity, physical properties and numerical heat transfer characteristics

Self Compacting Concrete (SCC) using Bromo Volcano Ash

EXPERIMENTAL STUDY ON PARTIAL REPLACEMENT OF CEMENT BY ZEOLITE IN M40 CONCRETE

Science and technology of concrete admixtures / edited by Pierre-Claude Aïtcin and Robert J. Flatt. Amsterdam [etc.], cop

Evaluation of Influence of Salt in the Cement Hydration to Oil Wells

Measuring the Effectiveness of Cure Materials

METHOD PERFORMANCE STUDY ON HEAT OF HYDRATION DETERMINATION OF CEMENT BY HEAT CONDUCTION CALORIMETRY

Measurement of an enthalpy change

Study of immobilization mechanism of chloride ion with different concentration of chloride ion using cement with powder admixtures

CHAPTER 17: THERMOCHEMISTRY. Mrs. Brayfield

COPYRIGHT FOUNTAINHEAD PRESS

Alka Seltzer Lab: Reaction rate - Factors that affect the rate of chemical reactions

Enthalpy changes

7th CANMET/ACI International Conference on Superplasticizers and Other Chemical Admixtures, Berlin, October 2003

Heat. Heat Terminology 04/12/2017. System Definitions. System Definitions

8. Energetics I. N Goalby chemrevise.org 1

CALORIMETRY: Heat of Fusion of Ice

Thermochemistry. The study of energy transfers and chemical reactions

Cement & Concrete Composites

Development of a New Method to Replace the Foam Index Test

Compaction Characteristics of Soil-Lime-Fly Ash Mixtures

1.4 Energetics. N Goalby chemrevise.org 1. Standard Enthalpy Change of Formation. Standard Enthalpy Change of Combustion

HEALTH MONITORING OF EARLY AGE CONCRETE

Name: Section: Score: /10 PRE LABORATORY ASSIGNMENT EXPERIMENT 7

NUTC R333. Influence of Mixing Procedure on Robustness of Self-Consolidating Concrete

USE OF DUNE SAND AS AN ALTERNATIVE FINE AGGREGATE IN CONCRETE AND MORTAR. Department of civil Engineering, The Open University Sri Lanka

Types of Energy Calorimetry q = mc T Thermochemical Equations Hess s Law Spontaneity, Entropy, Gibb s Free energy

AP Chemistry Lab #10- Hand Warmer Design Challenge (Big Idea 5) Figure 1

DESIGN OF ULTRA-THIN BONDED HOT MIX WEARING COURSE (UTBHMWC) MIXTURES

A MICROMECHANIC MODEL FOR CHARACTERIZATION OF CEMENT PASTE AT EARLY AGE VALIDATED WITH EXPERIMENTS

1. State in your own terms what is the first law of thermodynamics, a closed system, an isolated system, surroundings, heat, work, and energy.

Application of Ultrasonic Testing Technique to Evaluation of Strength Development in Early Age Mortars

2. Enthalpy changes. N Goalby chemrevise.org

Studies on Furan Polymer Concrete

Thermochemistry: Heat and Chemical Change

Chapter 8. Thermochemistry 강의개요. 8.1 Principles of Heat Flow. 2) Magnitude of Heat Flow. 1) State Properties. Basic concepts : study of heat flow

Health Monitoring of Early Age Concrete

Correlation between Paste and Concrete Flow Behavior

Energy, Heat and Chemical Change

Stability of Tricalcium Silicate and Other Primary Phases in Portland Cement Clinker

AP LAB 9b: Indirect Enthalpy Changes

Calorimetric Determination of Reaction Enthalpies

EXPERIMENT 9 ENTHALPY OF REACTION HESS S LAW

ALPHA OMEGA ZEOLITES FOR THE OILFIELD BRIEF

AP CHEMISTRY NOTES 4-1 THERMOCHEMISTRY: ENTHALPY AND ENTROPY

TAM AIR ISOTHERMAL CALORIMETRY

Development of a multiple linear regression model for predicting the 28-day compressive strength of Portland pozzolan cement

Thermodynamics for Dissolving an Ionic Salt (NaNO 3(s) )

Standards 2.4 and 3.4. Background Standard 2.4 Conservation of Energy (Standard 6.5)

AP Chemistry: Designing an Effective Hand Warmer Student Guide INTRODUCTION

S T A T I O N 1 E X O T H E R M I C / E N D O T H E R M I C P R O C E S S E S

Rheology Testing of Deep Foundation Concrete

Prajapati et al, International Journal of Advanced Engineering Research and Studies E-ISSN

An Evaluation of the Maturity Method (ASTM C 1074) for Use in Mass Concrete

Specific Heat of a Metal

RESEARCH INTO THE CORRELATION BETWEEN CONCRETE STRENGHT AND UPV VALUES. B. Tumendemberel, Ts. Baigalimaa

Cement Hydration with Ultrasound Treated Clinoptilolite

Experimental studies of sorption and transport of moisture in cement based materials with supplementary cementitious materials

EXPERIMENT ET: ENERGY TRANSFORMATION & SPECIFIC HEAT

Thermochemistry: Part of Thermodynamics

Transcription:

TTCC/NCC Conference September 23, 2008 Practical Semi-Adiabatic Calorimetry for Concrete Mixture Evaluation Tim, PE Senior Technical Service Engineer

Definitions calorimetry cal o rim e try (kāl'ə-rĭm'ĭ-trē) n. Measurement of the amount of heat evolved or absorbed in a chemical reaction, change of state, or formation of a solution. adiabatic adi a bat ic (ā-dē-ə-ba-tik), adj. Occurring without loss or gain of heat. For our purposes: semi-adiabatic calorimetry, n. Indication of the heat evolved from a cementitious mixture hydrating in an environment or container having some thermal insulation properties, according to a record of the mixture s changing temperatures over time. 2

Background Compounds in portland cement clinker Compounds responsible for most of the heat evolved during the first 24 hours of hydration C 3 S = 3CaO SiO 2 (Tricalcium silicate) C 2 S = 2CaO SiO 2 (Dicalcium silicate) C 3 A = 3CaO Al 2 O 3 (Tricalcium aluminate) C 4 AF = 4CaO Al 2 O 3 Fe 2 O 3 (Tetracalcium aluminoferrite) 3

Background C 3 A and C 3 S hydration C 3 A hydration A initial aluminate peak, controlled by sulfates interaction B dormancy period C main peak, primarily from C 3 S hydration C 3 S hydration The amount and timing of evolved heat during hydration are influenced by such factors as cement chemistry, mix temps, interaction of admixtures, sample mass effects, etc. 4

Isothermal versus semi-adiabatic calorimetry IsoCal results at 73 F Concrete Isothermal Semi-adiabatic 5 Source: W. R. Grace

Isothermal versus semi-adiabatic calorimetry Isothermal calorimetry is usually preferred when quantitative results are needed Semi-adiabatic calorimetry: Value is generally in comparative data Simpler, less expensive equipment Results are affected by certain variables Useful in the field or the lab 6

Applications of semi-adiabatic calorimetry Comparing set time effects & hydration efficiency Different admixtures, SCMs or cements Sensitivity of admix dose, SCM replacement rate Effects of mix temperature Troubleshooting concrete field problems Incompatibility (sulfate balance) influences Set time & other early hydration issues Cement production QC optimizing sulfates content Coming soon alternative time of set (C 403) method 7

Measuring & recording temperature changes 8

Semi-adiabatic calorimetry equipment Grace AdiaCal Solidus Integration ThermoCal 9

Semi-adiabatic calorimetry equipment Test method variables Mortar or paste? Mixing method / equipment Volume / mass of test sample? How much insulation? Initial mixture temperature Environment temperature Control of environment temperature 10

Test method variables and considerations Mixing equipment & procedures Mortar: Paste: Wet-sieved concrete C 305 (4 min.) C 305 (2¼ min.) Hand-held kitchen mixer Kitchen-type blender 1 minute or less may be adequate mixing time Differences in mixing shear may influence results 11

Test method variables and considerations Mortar or concrete versus paste Lab vs. field Concrete & mortar better represent field set times Paste is preferred for comparing some hydration effects Paste mixing is faster Choice should also consider sample mass effects 12

Test method variables and considerations Mortar vs. paste 90 degrees F mixtures with 25% Class F ash and water reducer Paste @ 0.52 w/cm, 500g powder content Mortar @ 0.52 w/cm, 500g powder content, 1425g SSD concrete sand, mixed via C305 13

Test method variables and considerations Mortar vs. paste paste 3x6 cyl 73 deg F mixtures: A A) no ash or admix, w/c = 0.54 B) 25% C ash + 3 oz/cwt type A WR, w/cm = 0.51 C) 25% F ash + 4 oz/cwt MR WR, w/cm = 0.51 A C B mortar 3x6 cyl C B 14

Test method variables and considerations Sample mass & insulation Affect magnitude of peaks and possibly timing Affect rate of heat decay after exotherm peaks Insulation choices should depend on Importance of ambient temp effects Magnitude of peaks expected Test objectives Main peak shapes can be influenced by sample mass and/or insulation value of container 15

Test method variables and considerations Sample mass comparison, paste (minimal insulation) Mixtures with 25% Class C ash and water reducer at 73 degrees F Cylindrical samples ranging from 135cc (2 x 2.6 ) to 1070cc (4 x 5.2 ) 16

Test method variables and considerations Insulation effects, paste Paste mixtures with 25% Class C ash and water reducer at 73 degrees F in 3x6 cylinders with varying levels of insulation 17

Test method variables and considerations Effects of sample mass & insulation, paste 73 degrees F paste mixtures with 25% Class C ash and water reducer 4x8 cylinder, Adiacal coffee cup in insulated box coffee cup, ambient 18

Set time evaluation with SAC Methods under development for a C 403 alternative: Highly insulated samples of concrete or mortar Mathematical procedures for determining set time from data - Derivatives - Fractions - 4 th order fit Relative time-of-set comparisons can be made using a simple visual indication of the point half-way up the C 3 S heat rise (50% of peak). 19

Relative set times - 50% of peak comparisons Influence of Class C and Class F fly ash Semi-adiabatic paste calorimetry: mixtures @ 90 degrees F with and without 25% ash and 3.75 oz/cwt of a type A/B/D water reducer 20

Relative set times - 50% of peak comparisons Influence of admix dose & retarder Semi-adiabatic paste calorimetry: all mixtures @ 90 degrees F with 25% F ash and indicated doses of type A/B/D water reducer & retarder 21

Comparison of C 403 concrete initial set (lab mixes) and paste thermal set (50% of peak) indications, SAC Lab concrete vs. semi-adiabatic paste calorimetry: all mixtures @ 73 degrees F, with and without normal doses of water reducing admix and indicated cementitious blends of cement-slag-ash(c/f) 100-0-0 75-0-25C 75-0-25F 75-0-25C 75-0-25F 50-35-15C No admix WR A WR A WR B WR B WR B 22

Relative set times Two admixtures compared for temperature & dosage effects Semi-adiabatic paste calorimetry: 0.40 w/c cement-only mixtures @ 73 or 50 deg F, with 3 or 6 oz/cwt of 2 different candidate mid-range admixtures 73 F 50 F 23

4x8 concrete cylinders - Adiacal 517 pcy concrete mixtures at constant slump, with or without 25% C ash, 3 oz/cwt type A/B/D WR, 2 different type I cement samples (same source) A ash + WR A no admix or ash B ash + WR 24

4x8 concrete cylinders - Adiacal Mortar vs. concrete 470 pcy concrete at constant slump, with 10% C ash and 3.2 oz/cwt type A/B/D WR, with or without AE. With air -mortar No air mortar No air - concrete With air concrete 25

Developing ASTM set time method Current draft of C09.23 thermal set time document specifies highly insulated 6 to 7 - diameter samples of concrete 34 33 32 31 30 Temperature (C) 29 28 27 26 25 24 23 22 0 200 400 600 800 1000 1200 1400 1600 Time from contact of cement and water (minutes) 26

Responsible for certain concrete performance issues Cement SO 3 content is spec limited and typically optimized using procedures that do not account for other influences. Other materials and conditions affect demand for sulfates: Admixtures Some SCM s, especially Class C fly ash Hot weather If early C 3 A hydration becomes uncontrolled due to the depletion of soluble sulfates, erratic behavior results: Sulfate balance influences and issues Incompatibility of concrete materials Unpredictable (sometimes extreme) set effects and / or slump loss Interrupted silicate hydration & strength gain 27

Sulfate balance influences and issues Related concrete behavior Mild influences - typically with higher temps: Some increase in slump loss Slight extending of set time Unexpected responses to admixtures Nearer the incompatibility threshold: Sluggish strength gain More severe slump loss, extended set True incompatibility behavior: No normal set, 24 to 48 hours or longer, or Flash set (extreme cases) Interrupted strength gain for several days 28

Example: sulfate balance effects of changes in temperature, fly ash %, or water reducer dosage baseline mix has 20% ash with 5 oz/cwt water reducer at 90 F baseline mix properties MIX TEMP, F 85 90 95 100 105 FLY ASH, % 15 20 25 30 35 WR DOSE, oz/cwt 4 5 6 7 8 normal strength gain increasingly delayed strength gain normal set marginal slump loss, longer set threshold zone extremely delayed set flash set 29

Semi-adiabatic paste calorimetry & mortar cubes: effects of fly ash content, mixtures with 6 oz/cwt type A/B/D water reducer, 90º F initial temp, cement SO 3 = 3.3 or 3.7% ΔT (Tsample Tambient), F compressive strength, psi 3.3-10% 3.7-35% 3.7-25% 4.1-35% 3.3-25% 3.3-35% Hydration time, hours 30

Semi-adiabatic paste calorimetry & mortar cubes: effects of different admixtures compared in mixtures with 25% fly ash, 90º F initial temp, cement SO 3 = 3.3% compressive strength, psi ΔT (Tsample Tambient), F LwrA, 6oz LwrB, 6oz LwrC, 8oz CSwr, 6oz 31 hydration time, hours

Comparison of effects of different gypsum sources on cements made from two different clinkers Clinker A + Gyp A Clinker A + Gyp B Clinker B + Gyp B Clinker B + Gyp A Clinker C + blend Cement plant QC testing effects of different gypsum sources, 90 degree F mixtures with 25% Class C ash + 6 oz/cwt admix (upper) or 9 oz/cwt (lower) Clinker A + Gyp A + 6 oz Clinker A + Gyp B + 6 oz Clinker C + blend + 6 oz Clinker B + Gyp A + 6 oz Clinker B + Gyp B + 6 oz Clinker A + Gyp A + 9 oz Clinker A + Gyp B + 9 oz Clinker B + Gyp A + 9 oz Clinker B + Gyp B + 9 oz 32

Cement sulfates evaluation: semi-adiabatic paste calorimetry, 0.40 w/cm mixtures @ 95 deg F, 25% Class C ash, 4 oz/cwt WR, cement samples @ various SO 3 % A1, SO3= 3.08 A4, SO3= 3.28 A3, SO3= 3.21 B, (control) optimized SO3 A5, SO3= 3.06 A2, SO3= 3.16 Cement source A is being evaluated. A1, SO3 = 3.08 A2, SO3 = 3.16 A3, SO3 = 3.21 A4, SO3 = 3.28 A5, SO3 = 3.06 B, SO3 = 3.5 (opt.) paste specimen compressive breaks @ 18 hrs, psi 33

Cement sulfates evaluation: admixture sensitivity comparison, same mixtures with admix dosage doubled, to 8 oz/cwt WR A2, SO3= 3.16 B, (control) optimized SO3 A1, SO3= 3.08 A4, SO3= 3.28 A5, SO3= 3.06 A3, SO3= 3.21 Conclusion: At the lower SO 3 levels, cement source A may be undersulfated for use in aggressive mixes at higher temperatures. A1, SO3 = 3.08 A2, SO3 = 3.16 A3, SO3 = 3.21 A4, SO3 = 3.28 A5, SO3 = 3.06 B, SO3 = 3.5 (opt.) paste specimen compressive breaks @ 18 hrs, psi 34

ASTM methods - hydration kinetics using calorimetry Standard practice for Measuring hydration kinetics of hydraulic cementitious mixtures using isothermal calorimetry 1. Scope 1.1 This practice describes the apparatus and procedure for measuring relative differences in hydration kinetics of hydraulic cementitious mixtures, either in paste or mortar (Note 1), including those containing admixtures, various supplementary cementitious materials (SCM), and other fine materials, by measuring the thermal power using an isothermal calorimeter. NOTE 1- Paste specimens are often preferred for mechanistic research when details of individual reaction peaks are important or for particular calorimetry configurations. Mortar specimens may give results that have better correlation with concrete setting and early strength development and are often preferred to evaluate different mixture proportions for concrete. Both paste and mortar studies have been found to be effective in evaluating concrete field problems due to incompatibility of materials used in concrete mixtures. 35

Hotel room calorimetry 36

Initial temp rise, all mixes (1:25 into testing) 37

+/- 16 hours into testing 38

+/- 16 hours into testing 39

Graph of data using Report Generator 40

Practical SAC for Concrete Mixture Evaluation Questions? Tim, PE Senior Technical Service Engineer tim.cost@holcim.com 41