COUPP500: a 500kg Bubble Chamber for Dark Matter Detection

Similar documents
Backgrounds in PICO. Eric Vázquez Jáuregui SNOLAB. AARM Meeting Fermilab; Batavia IL, USA; March 19, 2014

Bubble Chambers for Direct Dark Matter Searches in COUPP

COUPP: Bubble Chambers for Dark Matter Detection

Miguel Ardid Universitat Politècnica de València SUSY 2013

COUPP. Carbon and Fluorine Recoil Thresholds. Alan Robinson July 26, 2012 IDM 2012, Chicago, IL

Dark Ma'er Search Results from PICO- 60 and PICO- 2L

Toward a next-generation dark matter search with the PICO-40L bubble chamber. Scott Fallows TAUP2017 Laurentian University 24 July 2017

Studies of the XENON100 Electromagnetic Background

Backgrounds and Sensitivity Expectations for XENON100

Constraints on Low-Mass WIMPs from PICASSO. Carsten B. Krauss University of Alberta for the PICASSO Collaboration IDM Chicago, July

PoS(idm2008)010. The PICASSO Dark Matter Search Project. A. Davour for the PICASSO collaboration Queen s University

Outline. Dark Matter Physics at SNOLAB: And Future Prospects. Overview of SNOLAB DarkMatter Program. Status of Current Experiments

Simulations, backgrounds, and uncertainties in PICO-2L. Alan Robinson May 20, 2015 AARM, Rapid City South Dakota

Bubble Chamber Calibra-ons

Rare Event Searches and the Underground

Background Studies for the XENON100 Experiment. Alexander Kish Physics Institute, University of Zürich Doktorandenseminar August 30, 2010 UZH

Search for Dark Matter with Liquid Argon and Pulse Shape Discrimination

arxiv: v3 [hep-ex] 3 Mar 2016

Dark Matter Search With The PICASSO Experiment

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

The XENON Dark Matter Project: Status of the XENON100 Phase. Elena Aprile Columbia University

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

Current status of LUX Dark Matter Experiment

LARGE UNDERGROUND XENON

Recent Progress from the DEAP-3600 Dark Matter Direct Detection Experiment

Sensitivity and Backgrounds of the LUX Dark Matter Search

SuperCDMS SNOLAB: A G2 Dark Matter Search. Ben Loer, Fermilab Center for Particle Astrophysics On behalf of the SuperCDMS Collaboration

The Search for Dark Matter with the XENON Experiment

Bubble Chambers for Dark Matter Detection

Background simulations and shielding calculations

Ultra-Low Background Counting and Assay Studies At SNOLAB

Low Background Counting At SNOLAB

The XENON100 Dark Matter Experiment at LNGS: Status and Sensitivity

XENONNT AND BEYOND. Hardy Simgen. WIN 2015 MPIK Heidelberg. Max-Planck-Institut für Kernphysik Heidelberg

DarkSide-50: performance and results from the first atmospheric argon run

The DarkSide-50 Outer Detectors

The Picasso Experiment Plans and Results Carsten Krauss Queen s University

Study well-shaped germanium detectors for lowbackground

UCLA Dark Matter 2014 Symposium. Origins and Distributions of the Backgrounds. 15 min

The next generation dark matter hunter: XENON1T status and perspective

Search for low-mass WIMPs with Spherical Detectors : NEWS-LSM and NEWS-SNO

The LZ Experiment Tom Shutt SLAC. SURF South Dakota

The Direct Search for Dark Matter

Recent results from PandaX- II and status of PandaX-4T

Dark Matter Detection and the XENON Experiment. 1 Abstract. 2 Introduction

Direct Detection of Dark Matter with LUX

Ultra-Low Background Measurement Capabilities At SNOLAB

PoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University

BubXe: a liquid xenon bubble chamber for Dark Matter detection!

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

The XENON100 Dark Matter Experiment

Luca Grandi.

Background and sensitivity predictions for XENON1T

A survey of recent dark matter direct detection results

Recent results from the UK Dark Matter Search at Boulby Mine.

Early commissioning calibration data sets for DEAP-3600

LUX-ZEPLIN (LZ) Status. Attila Dobi Lawrence Berkeley National Laboratory June 10, 2015 WIN Heidelberg

LUX: A Large Underground Xenon detector. WIMP Search. Mani Tripathi, INPAC Meeting. Berkeley, May 5, 2007

Recent Results from the PandaX Experiment

Background Modeling and Materials Screening for the LUX and LZ Detectors. David Malling Brown University LUX Collaboration AARM Meeting February 2011

The XENON1T Experiment

Low Background Experiments and Material Assay. Tessa Johnson NSSC Summer School July 2016

DarkSide. Bianca Bottino Università di Genova and INFN Sezione di Genova on behalf of the DarkSide collaboration 1

Neutron background in large-scale xenon detectors for dark matter searches

next The NEXT double beta decay experiment Andrew Laing, IFIC (CSIC & UVEG) on behalf of the NEXT collaboration. TAUP2015, Torino, 8/09/2015

David Reyna Belkis Cabrera-Palmer AAP2010, Japan

The XENON1T experiment

DARK MATTER SEARCH AT BOULBY MINE

Direkte Suche nach Dark Matter

XMASS: a large single-phase liquid-xenon detector

Distillation purification and radon assay of liquid xenon

Sodium-iodide with Active Background REjection. Irene Bolognino

DarkSide new results and prospects

arxiv:astro-ph/ v1 15 Feb 2005

The CDMS-II Dark Matter Search and SuperCDMS

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

The JUNO veto detector system. Haoqi Lu Institute of High Energy physics (On Behalf of the JUNO Collaboration) TIPP2017, May22-26,Beijing

Neutrino Physics. Neutron Detector in the Aberdeen Tunnel Underground Laboratory. The Daya Bay Experiment. Significance of θ 13

DarkSide-20k and the Darkside Program for Dark Matter Searches

Direct Search for Dark Matter

Background study for solar neutrino measurement in Super Kamiokande

School of Mathematics and Physics, Fujian University of Technology, Fuzhou , China

the DarkSide project Andrea Pocar University of Massachusetts, Amherst

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

Direct dark matter search with XMASS. K. Abe for the XMASS collaboration

DarkSide-20k and the future Liquid Argon Dark Matter program. Giuliana Fiorillo Università degli Studi di Napoli Federico II & INFN Napoli

Results from DarkSide-50 with underground argon

The XMASS experiment. Y. Kishimoto for the XMASS collaboration March 24 th, 2014 Recontres de Moriond, Cosmology

PANDA-X A New Detector for Dark Matter Search. Karl Giboni Shanghai Jiao Tong University

Dark matter search with the SABRE experiment

Prospects for WIMP Dark Matter Direct Searches with XENON1T and DARWIN

XENON1T: opening a new era in the search for Dark Matter. Elena Aprile, Columbia University on behalf of the Collaboration, UCLA, February 17, 2016

? Simulation. of PICASSO detectors. Marie-Hélène Genest - Université de Montréal

Neutrinoless Double Beta Decay Search with SNO+

Juan Estrada Fermi National Accelerator Laboratory 1

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

Direct WIMP Detection in Double-Phase Xenon TPCs

Direct Detection in the next five years: Experimental challenges and Phonon Mediated Detectors

The XMASS Experiment. Jing LIU Kavli IPMU, Univ. of Tokyo PPC2013, Jul Deadwood, SD, USA

Shielding Strategies. Karl Tasso Knöpfle MPI Kernphysik, Heidelberg

Transcription:

COUPP500: a 500kg Bubble Chamber for Dark Matter Detection Eric Vázquez Jáuregui SNOLAB Identification of Dark Matter 2012 Chicago IL, USA; July 26, 2012

KICP - University of Chicago Juan Collar (PI, spokesperson), R. Neilson, Alan E. Robinson Indiana University South Bend E. Behnke, T. Benjamin, Emily Grace, C. Harnish, I. Levine, T. Nania Fermi National Accelerator Laboratory Steve J. Brice, Dan Broemmelsiek, Peter S. Cooper, Mike Crisler, Jeter Hall, W. Hugh Lippincott, Erik Ramberg, Andrew Sonnenschein, Fermilab Engineers and Technicians Northwestern University C. Eric Dahl Politecnica Valencia M. Ardid, M. Bou-Cabo SNOLAB Eric Vázquez-Jáuregui Virginia Tech D. Maurya, S. Priya The COUPP collaboration

COUPP bubble chambers Target material: superheated CF 3 I spin-dependent/independent Particles interacting evaporate a small amount of material: bubble nucleation Cameras record bubbles Piezo sensors detect sound Recompression after each event

COUPP bubble chambers The ability to reject electron and gamma backgrounds by arranging the chamber thermodynamics such that these particles do not even trigger the detector

COUPP bubble chambers The ability to reject electron and gamma backgrounds by arranging the chamber thermodynamics such that these particles do not even trigger the detector The ability to suppress neutron backgrounds by having the radioactively impure detection elements far from the active volume and by using the self-shielding of a large device and the high granularity to identify multiple bubbles

COUPP bubble chambers The ability to reject electron and gamma backgrounds by arranging the chamber thermodynamics such that these particles do not even trigger the detector The ability to suppress neutron backgrounds by having the radioactively impure detection elements far from the active volume and by using the self-shielding of a large device and the high granularity to identify multiple bubbles The ability to build large chambers cheaply and with a choice of target fluids

COUPP bubble chambers The ability to reject electron and gamma backgrounds by arranging the chamber thermodynamics such that these particles do not even trigger the detector The ability to suppress neutron backgrounds by having the radioactively impure detection elements far from the active volume and by using the self-shielding of a large device and the high granularity to identify multiple bubbles The ability to build large chambers cheaply and with a choice of target fluids The ability to increase the size of the chambers without changing the size or complexity of the data acquisition

COUPP bubble chambers The ability to reject electron and gamma backgrounds by arranging the chamber thermodynamics such that these particles do not even trigger the detector The ability to suppress neutron backgrounds by having the radioactively impure detection elements far from the active volume and by using the self-shielding of a large device and the high granularity to identify multiple bubbles The ability to build large chambers cheaply and with a choice of target fluids The ability to increase the size of the chambers without changing the size or complexity of the data acquisition Sensitivity to spin-dependent and spin-independent WIMP couplings

Running at SNOLAB since 2010 World leading spin dependent limits (Michael B. Crisler talk) COUPP-4kg and COUPP-60kg Engineering run at Fermilab in 2011 Moving to SNOLAB Physics run in late 2012 (Andrew Sonnenschein talk)

COUPP at SNOLAB SNOLAB deepest and cleanest large-space international facility in the world 2 km underground near Sudbury, Ontario ultra-low radioactivity background environment Class 2000 Physics programme focused on neutrino physics and direct dark matter searches

COUPP at SNOLAB

γ and neutron calibrations AmBe and 252 Cf 60 Co and 133 Ba COUPP Iodine Recoil Threshold Experiment Low energy Iodine recoils π beam and silicon trackers (Hugh Lippincott talk) 88 Y/Be calibration chamber Monochromatic low energy neutrons (Alan E. Robinson talk) Calibrations

A tonne scale detector spin-independent sensitivity 9 10 47 cm 2, backgroundfree year running Beyond next generation (G2) device <9M total cost (R&D funded by NSF, waiting on DOE) Possible to use alternative fluids (C 4 F 10 ) R&D phase COUPP-500kg

Target fluid: CF 3 I C 4 F 10 at 15keV: SI rate 17 (WIMP mass 100 GeV) C 4 F 10 at 15(10)keV: SD rate 4(18) (WIMP mass 10 GeV) Inner vessel assembly: ultra-high-purity synthetic fused silica jar COUPP-500kg design Outer vessel: Stainless steel (φ= 60 inches) Acoustics sensors: piezoelectric acoustic transducers

Outer neutron shielding: neutron moderator muon veto temperature control Pressure control unit: COUPP-500kg design expand and recompress the chamber regulate chamber pressure Data acquisition: T and P sensors machine vision cameras acoustic transducers

R&D and calibrations Calibration of low energy nuclear recoil response CIRTE, 88 Y-Be,... Calibration of gamma rejection In-situ source for alpha calibration Bubble acoustics and acoustic sensors Extensive background simulation!

External backgrounds: Rock neutrons Muon induced neutrons (γ,n) reactions Internal backgrounds: COUPP-500kg simulations U and Th: fission and (α,n) on light elements 238 U direct decay Materials: SS, quartz,... Fluids: water, glycol, CF 3 I Radon Mine dust veto PMTs Acoustic transducers GEANT4 model

COUPP-500kg: external neutrons Fast neutrons from norite: 4000 n/m 2 /day Muon induced neutrons in: rock, water, stainless steel Water tank dimensions: φ = 6.8 m L = 7.4 m 67 muons/day Neutron energy for (α,n) reaction in norite

COUPP-500kg: fission and (α,n) Stainless steel, quartz Water (buffer and tank), propylene glycol 238 U, 232 Th, 235 U Other backgrounds: Mine dust veto PMTs

COUPP-500kg: gammas, betas and (γ,n) reactions Gamma and beta decays: Interact by Compton scattering, photoelectric absorption, and pair production Rejection factor: 10 10 10 12 COUPP-4kg at SNOLAB measured: < 3 10 11 at 15 kev COUPP-500kg expected: 10 6 events/kg-day (γ,n) reactions: 127 I(γ,n) 126 I: 4 10 8 events/kg-day SNOLAB: 4 γ/cm 2 /yr > 9MeV Other reactions: < 7 10 10 events/kg-day

COUPP-500kg: acoustic transducers Two positions simulated: (10 ppb 238 U and 232 Th 0.1 ppb 235 U, 10 Bq/kg 210 Pb) side only, 25g 2 10 8 events/kg-day bottom only, 25g 3 10 7 events/kg-day Acoustic simulation in progress for design optimization screening for salts used in the manufacture of piezoelectric transducers around 15 samples (high purity germanium detector at SNOLAB)

COUPP-500kg: CF 3 I purity α decays and neutrons from (α,n): 0.0159 ppt 238 U 0.0488 ppt 232 Th 0.0025 ppt 235 U 25 µbq/kg 222 Rn 25 µbq/kg 210 Pb COUPP-500kg: radon Radon deposition and emanation on all surfaces Radon diffusion in all fluids 6 10 6 events/kg-day vetoable: alpha + neutron

Background Summary Neutron source Rate Single evts/yr Multiple evts/yr Rock 4000 ± 1000 n/m 2 /d O(10 11 ) O(10 11 ) Muon induced from 5.4 10 11 n/cm 2 /s 0.0904 ± 0.0131 0.2544 ± 0.0219 rock Muon induced from 67.11 ± 1.85 µ/d 0.493 ± 0.014 1.050 ± 0.030 shield or detector U and Th in 0.0504 ± 0.0030 0.1242 ± 0.0068 detector materials steel only 1ppb 238 U and 232 Th 0.0360 ± 0.0026 0.0922 ± 0.0062 quartz only 10 2 ppb 238 U and 232 Th 0.0131 ± 0.0012 0.0290 ± 0.0026 Radon deposition Dep. Rate= 10 3 /m/y 0.0198 ± 0.0015 0.0415 ± 0.0030 onto and diffusion 100 Bq 222 Rn/m 3 in air into outer surface t=3 months A=2.21m 2 of quartz jar S=10, d e =1.0 mm Radon in water tank S=0.25, 100 Bq/m 3 Rn (1.83 ± 0.28) 10 3 (5.17 ± 0.60) 10 3 inner 18500L Radon in heat S=0.25 0.0230 ± 0.0021 0.0572 ± 0.0052 exchange pipes 100 Bq/m 3 Rn, 10L Radon emanation from A=34.81m 2 (1.39 ± 0.13) 10 3 (2.93 ± 0.26) 10 3 quartz and steel 100 µbq/m 2 Rn

Background Summary Neutron source Rate Single evts/yr Multiple evts/yr Mine dust on 0.01 g/m 2, 2.21 m 2 0.0127 ± 0.0011 0.0286 ± 0.0026 top surfaces 1.11 ppm 238 U 5.56 ppm 232 Th 127 I(γ,n) 126 I 4.0 γ/cm 2 /yr > 9MeV < 0.0069 other photonuclear < 1.3 10 4 Piezoelectric acoustic 10 ppb 238 U 0.0577 ± 0.0031 0.142 ± 0.008 transducers, 50g 10 ppb 232 Th side only, 25g 0.1 ppb 235 U 0.0036 ± 0.0002 0.0072 ± 0.0004 bottom only, 25g 10 Bq/kg 210 Pb 0.0541 ± 0.0031 0.134 ± 0.008 CF 3 I U and Th (α,n) 0.0159 ppt 238 U 1.078 ± 0.061 4.37 ± 0.25 0.0488 ppt 232 Th 0.0025 ppt 235 U 25 µbq/kg 222 Rn 25 µbq/kg 210 Pb Other radon induced 6mo. deposition on steel (8.0 ± 0.5) 10 6 (2.00 ± 0.12) 10 5 backgrounds 92.6µBq/m 3 in IV Total 1.84 ± 0.06 6.08 ± 0.25 Total unvetoable 0.264 ± 0.014 0.663 ± 0.025 4-page table, each 10 5 10 6 years simulated

Spin dependent proton cross section (cm 2 ) COUPP-500kg expected sensitivity at SNOLAB 10 36 10 38 10 40 CMS 10 42 SIMPLE (2011) PICASSO (2012) Super K (soft) COUPP (Jan. 2011) SIMPLE (2010) COUPP 4, 4 mo, 0 bg Super K (hard) cmssm COUPP (Apr. 2012) (χχ bb) (χχ W + W ) IceCube COUPP 60, 4 mo, 0 bg COUPP 60, 1 yr, 0 bg COUPP 500, 1 yr 10 1 10 2 10 3 10 4 WIMP Mass (GeV)

COUPP-500kg expected sensitivity at SNOLAB Spin independent cross section (cm 2 ) 10 40 10 41 10 42 10 43 10 44 10 45 10 46 10 47 cmssm COUPP (Jan. 2011) CDMS (SUF) COUPP (Apr. 2012) CDMS XENON10 COUPP 4, 4 mo, 0 bg XENON100 COUPP 60, 4 mo, 0 bg COUPP 60, 1 yr, 0 bg COUPP 500, 1 yr 10 1 10 2 10 3 WIMP Mass (GeV)

2013: Schedule Finish mechanical design of all major components Order Outer Vessel Prototype hydraulic system Test pressure control at full scale First tests of 3rd generation acoustic sensors Select SNOLAB installation location 2014: Water tank construction at SNOLAB Inner Vessel prototype testing at Fermilab High purity fluid system construction Control system and DAQ testing

2015: Schedule Construction of final Inner Vessel Installation of all equipment at SNOLAB Commissioning Ready for Physics data taking in 2016!

Conclusions COUPP family of detectors making huge improvements: COUPP-4kg currently running at SNOLAB COUPP-60kg running by the end of the year Calibrations, calibrations and calibrations: CIRTE, 88 Y/Be, gamma, neutron,... COUPP-500kg is the following target: a tonne scale detector spin-independent sensitivity: 9 10 47 cm 2 (background-free year running) inexpensive and versatile ready for physics in 2016

Conclusions COUPP family of detectors making huge improvements: COUPP-4kg currently running at SNOLAB COUPP-60kg running by the end of the year Calibrations, calibrations and calibrations: CIRTE, 88 Y/Be, gamma, neutron,... COUPP-500kg is the following target: a tonne scale detector spin-independent sensitivity: 9 10 47 cm 2 (background-free year running) inexpensive and versatile ready for physics in 2016 More great and beautiful physics from COUPP just around the corner!