ULTRA-SENSITIVE SOLUTIONS FOR REAL-TIME TRACE GAS ANALYSIS

Similar documents
IONICON Analytik GmbH., Eduard-Bodem-Gasse 3, 6020 Innsbruck, AUSTRIA

SIFT-MS. technology overview

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW

TOXICOLOGY & FORENSIC APPLICATIONS

Catalysis CAPABILITIES

Analytical Instrumentation

Introduction to GC/MS

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

VOC measurements in ambient air using Selected Ion Flow Tube Mass Spectrometry-automation and calibration considerations

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Kore Overview 2013 Dr Barrie Griffiths Kore Technology Ltd.

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Thermo Finnigan LTQ. Specifications

Extrel is widely respected for the quality of mass spectrometer systems that are

The Claviature of Gas Analysis

Finnigan LCQ Advantage MAX

Translational Biomarker Core

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Making Improvements to Today s Natural Gas Analysis Systems

Multi-residue analysis of pesticides by GC-HRMS

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Defining quality standards for the analysis of solid samples

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Mercury Stack Monitor SM-4

Secondary Ion Mass Spectroscopy (SIMS)

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

high performance OPTIC 3 and applications a total analytical solution

CHAPTER D3 TOF ION OPTICS

AMMS-100 Atmospheric Metal Monitoring System

Technical know-how in thermal analysis measurement

OF ALL THE CHEMISTRY RELATED SOFTWARE

Powerful Scan Modes of QTRAP System Technology

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Chemistry Instrumental Analysis Lecture 34. Chem 4631

FT-ICR Mass Spectrometer QUANTRA. Technical Description September quantra

Types of Analyzers: Quadrupole: mass filter -part1

473-SHX Dew Point Mirror

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

IN QUALITATIVE ANALYSIS,

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

LC-MS Based Metabolomics

Agilent G3212 GC-APCI Source

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Lecture 8: Mass Spectrometry

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

TANDEM MASS SPECTROSCOPY

Lecture 8: Mass Spectrometry

Introduction to Fourier Transform Infrared Spectroscopy

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?

HYPHENATED TECHNOLOGY GUIDE

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

ICP-MS. High Resolution ICP-MS.

Introduction to the Q Trap LC/MS/MS System

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Mass Spectrometry. Electron Ionization and Chemical Ionization

Extrel Application Note

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Harris: Quantitative Chemical Analysis, Eight Edition

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Natural Products. Innovation with Integrity. High Performance NMR Solutions for Analysis NMR

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Experience the most powerful benchtop NMR spectrometer

UV Source Series. UVS 10/35 gas discharge, UVS 300 duoplasmatron. Key Features

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Elecsys with ECL technology Still light years ahead

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

Modulyzer. Multiparameter Measuring Systems. ::: Unique Density & Concentration Meters

CHROMATOGRAPHY AND MASS SPECTROMETER

Compact Hydrogen Peroxide Sensor for Sterilization Cycle Monitoring

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Transcription:

ULTRA-SENSITIVE SOLUTIONS FOR REAL-TIME TRACE GAS ANALYSIS PRODUCT PORTFOLIO PROTON TRANSFER REACTION - MASS SPECTROMETRY

SERIES PTR-QiToF LoD < 1 pptv Resolution > 5,500 m/ m (FWHM) The IONICON PTR-QiTOF is a fast and ultra-sensitive instrument for trace analysis of volatile organic compounds (VOCs) at a very high time-resolution and mass resolving power. The PTR-QiTOF featuring a Quadrupole ion guide (Qi) is the most powerful PTR-TOFMS instrument on the market: 25x more sensitive, one order of magnitude lower detection limit and at least 20% higher mass resolution than the well-known and former IONICON flagship model PTR-TOF 8000. Quantitative analysis of the entire mass range within split-seconds and the highest ever recorded mass resolution of a commercial PTR-TOFMS allow for separation and unambiguous identification of complex samples. Qi > Quadrupole ion guide > Flagship PTR-TOFMS series instrument > Most sensitive and lowest detection limit > Highest mass resolving power Find out more: www.ionicon.com/ptr-qitof Paired with lightning speed and extreme sensitivity, the PTR-QiTOF sets a new standard for applications such as flux measurements. Our unique soft ionization (PTR) technology and extensive know-how in engineering of scientific instruments are the basis for the reliability, ultra-low detection limit, fast response time and robustness of our PTR-MS systems. THE SOLUTION FOR REAL-TIME TRACE GAS ANALYSIS

PTR-QiToF IONICON PTR-QiTOF SPECIFICATIONS* - Mass resolution: > 5,500 m/ m (FWHM) - Sensitivity & Limit of Detection m/z 79 > 1,000 (up to 3,000) cps/ppbv; LoD < 10 pptv (60 sec) m/z 181 > 1,500 (up to 4,500) cps/ppbv; LoD < 1 pptv (60 sec) - Response time: < 100 ms - TOF pulse frequency: up to 200 khz - Mass range: 1-10,000 amu - Linearity range: 1 pptv - 0.5 ppmv - Adjustable flow: 50-500 sccm - Inlet system (Different/Multiplexing inlet systems available on request): 1.2 m long inlet hose - with inert (PEEK) capillary Inlet system heating: 40-180 C (104-356 F) TECHNOLOGY We proudly rely on the unique IONICON PTR-MS soft ionization technology where by proton transfer from H 3 O +, all compounds with a higher proton affinity (PA) than water are ionized. Common constituents of air, such as N 2, O 2, Ar, CO 2 etc. have lower PAs than H 2 O and are therefore not detected. This is one of the main reasons for our market-leading low, real-time detection limit for trace compounds. Due to precisely controlled ion source and drift tube parameters, absolute quantification of VOC concentrations is possible. - Reaction chamber heating range: 40-120 C (104-248 F) - Power requirements: 100-115/200-230 V, max. 1,500 W - Dimensions (w x h x d): 60x110x80 cm (23.7x43.4x31.5 in.) - Weight (incl. SRI): < 175 kg (386 lbs) - Interfaces: 1x Touch screen 8x DI/O, 2x AI, 2x AO (additional I/Os on request) *Specifications are subject to change without prior notice. Product pictures and illustrations may differ from actual configuration. Detection limit, linearity range and resolution are dependent on the substances measured, integration time and system set-up. PTR-QiTOF - FEATURES AND BENEFITS Welcome to the future of ultimate performance! Using a specially crafted high-resolution time of flight (TOF) mass spectrometer including the new Quadrupole ion guide (Qi) in combination with the refined IONICON PTR technology, the PTR-QiTOF achieves a mass resolution of more than 5,500 m/δm FWHM, a limit of detection well below 1 pptv (in 60 sec), and an unmatched sensitivity of more than 1,500 (up to 4,500) cps/ppbv. This boost in sensitivity is especially beneficial for cutting edge applications like eddy-covariance flux measurements, where ultra-low VOC concentrations have to be quantified with more than 10 Hz. No sample preparation and the direct injection of analytes means no waiting time and no loss in capturing of relevant process parameters. This, together with a known simplicity, reliability and robustness is common to all our instruments. The IONICON PTR-QiTOF is optionally available with our proprietary Selective Reagent Ionization - Mass Spectrometry (SRI/SRI + ) technology featuring NO + + and O 2 (SRI) or Kr + (SRI + ) alternatively to H 3 O + as precursor ions created in the new ULTRA-PURE ion source (US Pat. 9,188,564). O 2+, but especially Kr +, have a higher ionization potential than H 3 O + and therefore many important (inorganic) substances such as CH 4, CO, CO 2, NO 2, SO 2, etc. can be detected and quantified using a single IONICON instrument. NO + as reagent ions help separating several isomeric VOCs that can subsequently be quantified in real-time. Article: P. Sulzer, et al., Int. J. Mass Spectrom. (2014), DOI: 10.1016/j.ijms.2014.05.004 IONICON Analytik GmbH Eduard-Bodem-Gasse 3 6020 Innsbruck Austria Tel.: +43 512 214 800 www.ionicon.com info@ionicon.com

SERIES LoD < 10 pptv Resolution > 5000 The IONICON PTR-TOF 8000 instrument is an ultra-sensitive detector for volatile organic compounds (VOCs) that allows for continuous VOC quantification with a very high mass resolution. Our bestselling time of flight based product combines very low online detection limits in the single-digit pptv-range covering a linearity range of six orders of magnitude, with high mass resolving power. Quantitative analysis of the whole mass range within a split-second with a resolution that even allows separation of isobaric compounds are remarkable features of the IONICON PTR-TOFMS technology. > High resolution time of flight > Low detection limit - high sensitivity > Separation of isobaric substances > Full mass range acquisition in a split-second Find out more: www.ionicon.com/products Direct injection of sample gases without preparation contributes to the speed and simplicity that is common to all our instruments. Our unique soft ionization (PTR) technology together with our extensive experience in gas-phase ion chemistry and engineering of scientific instruments are the basis for the reliability, ultra low detection limit, very low mass fragmentation, fast response time and robustness of our PTR-MS systems. THE SOLUTION FOR REAL-TIME TRACE GAS ANALYSIS

Picture: Georg Staudt / pixelio.de IONICON PTR-TOF 8000 SPECIFICATIONS* - Resolution: > - Response time: < 100 ms - Sensitivity: - Benzene: > > - m/z 181: > - Detection limits: - Averaged over 1 minute: Benzene < < 10 pptv - Averaged over 1 second: Benzene < < 80 pptv Response time: 100 ms Linearity range: 10 pptv - 1 ppmv Adjustable flow: 50-1000 sccm Inlet system : - - TECHNOLOGY O + 2 2 2 2 O and are therefore not detected. real-time detection limit for trace compounds. Due to precisely Reaction chamber heating range: 40-120 C Interfaces: - 1x Touch screen display - *Specifications are subject to change without prior notice. Product pictures and illustrations may differ from actual configuration. time and system set-up. PTR-TOF 8000 FEATURES AND BENEFITS high mass resolution in combination with high sensitivity and low detection limit that helped many scientists to gain new reflectron time of flight mass spectrometer in combination with below 10 pptv. The whole mass spectrum can be recorded in a split second instrumental mass range limitation and a linearity range over SRI-MS proprietary + + and O 2+ + + O + as precursor ions created in the O 2+ + O + 4 2 2 2 + as reagent subsequently be quantified in real-time. ROBUST, RELIABLE & EASY TO USE a touch screen display for parameter optimization and status 8000 in a re-usable eco-friendly flightcase container. 6020 Innsbruck Austria www.ionicon.com info@ionicon.com

Compact ultra-sensitive PTR-TOFMS - Trace VOC Analyzer Sensitivity > 400 cps/ppbv LoD < 5 pptv Resolution > 1500 m/ m The PTR-TOF 1000 ultra is the new benchmark for robust, compact & affordable real-time organic trace gas analyzers. Based on the successful PTR-TOF 1000 series platform, the PTR-TOF 1000 ultra offers all benefits of an affordable, small and light PTR-TOFMS instrument, complemented by an outstanding sensitivity, previously only available from top-of-the-market instruments. The PTR-TOF 1000 ultra features up to 10x more sensitivity thanks to the revolutionary new ION-BOOSTER funnel technology. > ION-BOOSTER funnel technology > 10x increased sensitivity > Compact & affordable PTR-TOFMS > Entire mass range in split-seconds Find out more: www.ionicon.com/ultra Quantitative analysis of the entire mass range in split-seconds and high mass resolution are features of all IONICON time-of-flight mass spectrometers. Direct injection of sample gas without preparation contributes to the speed and simplicity our instruments are known for. The unique soft ionization (PTR) technology together with our extensive experience in gas-phase ion chemistry and engineering of scientific instruments are the basis for the reliability, ultra-low detection limit, fast response time and robustness of our PTR-MS systems. THE SOLUTION FOR REAL-TIME TRACE GAS ANALYSIS

IONICON PTR-TOF 1000 ultra SPECIFICATIONS* - Mass resolution: > 1500 m/ m (FWHM) for m/z > 60 - Response time: < 100 ms - TOF pulse frequency: up to 150 khz - Sensitivity & Limit of Detection: m/z 79 > 300 cps/ppbv; LoD < 20 pptv (1 min) m/z 181 > 400 cps/ppbv; LoD < 5 pptv (1 min) - Mass range: 1-10,000 amu - Adjustable inlet flow: 50-800 sccm - Inlet system (Different/Multiplexing inlet systems available on request): 1.2 m long inlet hose - with inert (PEEK) capillary Inlet system heating: 40-180 C (104-356 F) - Reaction chamber heating range: 40-120 C (104-248 F) - Power supply and max. consumption: 100-230 V, 1500 W - Dimensions (w x h x d): 60x91x80 cm (23.7x35.9x31.5 in.) - Weight: < 150 kg (330.7 lbs) - Interfaces: 8x DI/O, 2x AI, 2x AO (digital/analog I/O package on request) *Specifications are subject to change without prior notice. Product pictures and illustrations may differ from actual configuration. Detection limit, linearity range and resolution are dependent on the substances measured, integration time and system set-up. PTR-TOF 1000 ultra BENEFITS The PTR-TOF 1000 ultra combines the latest IONICON PTR-TOFMS evolution with the new ION-BOOSTER funnel technology to perfection. In an ion funnel a RF-voltage focuses the ions through an array of ring electrodes, which improves ion transmission leading to a much higher sensitivity. The PTR-TOF 1000 ultra offers up to 10x more sensitivity for volatile organic compound (VOC) analysis in real-time compared to a PTR-TOF 1000 without ION-BOOSTER. This makes the advantageous time-of-flight based instrument even more suited for high-speed applications, challenged by very low VOC concentrations, complex samples or a large number of sample compounds, where e.g. quadrupole based or lower sensitivity VOC analyzers fail to perform. Built on the PTR-TOF 1000 series platform it is IONICON s smallest, lightest and most affordable ultra-sensitive PTR-TOFMS trace gas analyzer. PTR-MS We proudly rely on the unique IONICON PTR-MS soft ionization technology where by proton transfer from H 3 O +, all compounds with a higher proton affinity (PA) than water are ionized. Common constituents of air, such as N 2, O 2, Ar, CO 2 etc. have lower PAs than H 2 O and are therefore not detected. This is one of the main reasons for our market-leading low, real-time detection limit for trace compounds. Due to precisely controlled ion source and drift tube parameters, absolute quantification of VOC concentrations is possible. SRI-MS The IONICON PTR-TOF 1000 ultra is also available with Selective Reagent Ionization - Mass Spectrometry (SRI/SRI + ) featuring NO + and O 2 + (SRI) or Kr + (SRI + ) alternatively to H 3 O + as precursor ions created in the new ULTRA-PURE ion source (US Pat. 9,188,564). The benefits are extraordinary as O 2+, but especially Kr +, have a higher ionization potential than H 3 O + and therefore many important (inorganic) substances such as CH 4, CO, CO 2, NO 2, SO 2, etc. can be detected and quantified using a single IONICON instrument. NO + as reagent ions help separating several isomeric VOCs that can subsequently be quantified in real-time. ROBUST, RELIABLE & EASY TO USE The PTR-TOF 1000 ultra is completely software controlled. Installed in a space-saving rack and mounted on wheels, it allows for easy transportability and variable location measurements. We deliver the PTR-TOF 1000 ultra in a re-usable eco-friendly flightcase container. IONICON Analytik GmbH Eduard-Bodem-Gasse 3 6020 Innsbruck Austria Tel.: +43 512 214 800 www.ionicon.com info@ionicon.com

SERIES LoD < 10 pptv Resolution > 1500 m/ m (FWHM) The IONICON PTR-TOF 1000 is a fast and sensitive instrument for trace volatile organic compounds (VOCs) quantification at a very high time resolution. This PTR-TOFMS system has been extensively tested by leading scientists in field measurement and flight campaigns. It is the smallest, lightest and most affordable time of flight based PTR-MS we ever constructed. Quantitative analysis of the entire mass range within split-seconds and higher resolution for better separation and identification are now available in an instrument with the size, weight and price usually resctricted to quadrupole PTR-MS. > Ultra-fast, sensitive and affordable > Proven in field and flight campaigns > Smallest and lightest PTR-TOFMS > Entire mass range in split-seconds Find out more: www.ionicon.com/products Direct injection of sample gases without preparation contributes to the speed and simplicity that is common to all our instruments. Our unique soft ionization (PTR) technology together with our extensive experience in gas-phase ion chemistry and engineering of scientific instruments are the basis for the reliability, ultra-low detection limit, fast response time and robustness of our PTR-MS systems. THE SOLUTION FOR REAL-TIME TRACE GAS ANALYSIS

IONICON PTR-TOF 1000 SPECIFICATIONS* - Mass resolution: > 1500 m/ m (FWHM) for m/z > 60 - Response time: < 100 ms - TOF pulse frequency: up to 150 khz - Sensitivity & Limit of Detection: m/z 79 > 40 cps/ppbv; LoD < 20 pptv (1min) m/z 181 > 100 cps/ppbv; LoD < 10 pptv (1min) - Mass range: 1-10,000 amu - Linearity range: 10 pptv - 1 ppmv - Adjustable inlet flow: 50-800 sccm - Inlet system (Different/Multiplexing inlet systems available on request): 1.2 m long inlet hose - with inert (PEEK) capillary Inlet system heating: 40-180 C (104-356 F) TECHNOLOGY The innovative technology IONICON trace gas analyzers are based on is Proton Transfer Reaction - Mass Spectrometry (PTR-MS). This unique, soft ionization is realized by proton transfer from H 3 O + ions to all compounds with a higher proton affinity (PA) than water. Common constituents of air such as N 2, O 2, Ar, CO 2 etc. have lower PAs than H 2 O and are therefore not ionized. This is one of the main reasons for our market-leading low real-time detection limit for trace compounds and due to precisely controlled ion source and drift tube parameters, absolute quantification of VOC concentrations is possible. - Reaction chamber heating range: 40-120 C (104-248 F) - Power supply and max. consumption: 100-230 V, 1500 W - Dimensions (w x h x d): 60x91x80 cm (23.7x35.9x31.5 in.) - Weight (incl. SRI): < 150 kg (330.7 lbs) - Interfaces: 8x DI/O, 2x AI, 2x AO (digital/analog I/O package on request) *Specifications are subject to change without prior notice. Product pictures and illustrations may differ from actual configuration. Detection limit, linearity range and resolution are dependent on the substances measured, integration time and system set-up. PTR-TOF 1000 FEATURES AND BENEFITS The PTR-TOF 1000 is an IONICON PTR-TOFMS instrument with dimensions, weight and price usually restricted to quadrupole PTR-MS, but having all the advantages of the more powerful time of flight based solutions: acquisition of the entire mass range in split-seconds and higher resolution for better separation and identification. The instrument demonstrated its reliability and robustness but also its remarkable technical abilities and speed during various international campaigns and is ideally suited for analysis of VOCs at a very high time resolution. It comes with a fully integrated IONICON data acquisition and data treatment software suite. Enter into the world of PTR-TOFMS with IONICON s new PTR-TOF 1000: it is the smallest, lightest and most affordable time of flight based PTR-MS we have ever constructed. The IONICON PTR-TOF 1000 is also available with Selective Reagent Ionization - Mass Spectrometry (SRI/SRI + ) featuring NO + and O 2 + (SRI) or Kr + (SRI + ) alternatively to H 3 O + as precursor ions created in the new ULTRA-PURE ion source (US Pat. 9,188,564). The benefits are extraordinary as O 2+, but especially Kr +, have a higher ionization potential than H 3 O + and therefore many important (inorganic) substances such as CH 4, CO, CO 2, NO 2, SO 2, etc. can be detected and quantified using a single IONICON instrument. NO + as reagent ions help separating several isomeric VOCs that can subsequently be quantified in real-time. ROBUST, RELIABLE & EASY TO USE The PTR-TOF 1000 is completely software controlled. Installed in a space-saving rack and mounted on wheels, it allows for easy transportability and variable location measurements. We deliver the PTR-TOF 1000 in a re-usable eco-friendly flightcase container. IONICON Analytik GmbH Eduard-Bodem-Gasse 3 6020 Innsbruck Austria Tel.: +43 512 214 800 www.ionicon.com info@ionicon.com

SERIES THE WORLD s LEADING PTR-MS COMPANY PRESENTS HIGH SENSITIVITY PTR-QMS 5 00 LoD < 1 pptv The IONICON High-Sensitivity PTR-QMS 500 instrument is an ultra-sensitive detector for volatile organic compounds (VOCs) that allows for continuous VOC quantification. Our premium PTR-QMS series product, based on quadrupole mass spectrometry, combines market-leading low online detection limits reaching even ppqv-levels, with high selectivity and a very fast response time. Direct injection of sample gases without preparation contributes to the speed and simplicity that is common to all our instruments. Selective qualitative and quantitative analysis of trace compounds in remarkably short measurement times combined with a system linearity range covering over seven orders of magnitude satisfy the highest claims of the world's best scientists. Mass Range 1-512 amu > Low detection limit < 1 pptv > Real-time VOC quantification > Soft & efficient ionization technology > Fast and easy direct sample injection Find out more: www.ionicon.com/products Our unique soft ionization (PTR) technology together with our extensive experience in gas-phase ion chemistry and engineering of scientific instruments accounts for the reliability, ultra low detection limit, very low mass fragmentation, fast response time and robustness of our PTR-MS systems. THE SOLUTION FOR REAL-TIME TRACE GAS ANALYSIS

HIGH SENSITIVITY PTR-QMS 5 00 IONICON HS PTR-QMS 500 SPECIFICATIONS* - Mass range: 1-512 amu - Resolution**: < 1 amu - Response time: 100 ms - Sensitivity (Benzene): > 300 cps/ppbv - Detection limit**: < 1 pptv - Linearity range**: 1 pptv - 10 ppmv - Adjustable flow: 80-800 sccm (at 60 C) - Inlet system (Different inlet systems available on request): - 1.2 m long inlet hose - with internal inert (PEEK) capillary - Inlet system heating: up to 180 C (356 F) - Reaction chamber heating range: 45-120 C (104-248 F) - Power supply and max. consumption: 115/230 V, 1500 W - Dimensions (w x h x d): 60x91x60 cm (23.7x35.9x23.7 in.) - Weight (incl. SRI): 132 kg (291 lbs) - Main interfaces: 1x Touch screen display 1x Ethernet 10/100 Mbit RJ45 (TCP/IP) 8x DO, 4x DI, 4x AI, 4x AO *Specifications are subject to change without prior notice. Product pictures and illustrations may differ from actual configuration. **Detection limit, linearity range and resolution are dependent on the substances measured, integration time and system set-up. TECHNOLOGY The innovative technology IONICON PTR-MS products are based on is Proton Transfer Reaction - Mass Spectrometry (PTR-MS). This unique soft ionization is realized by proton transfer from H 3 O + ions to all compounds with a higher proton affinity (PA) than water. Common constituents of air such as N 2, O 2, Ar, CO 2 etc. have lower PAs than H 2 O and are therefore not ionized. This is one of the main reasons for our market-leading low online detection limit for trace compounds and due to precisely controlled ion source and drift tube parameters, absolute quantification of VOC concentrations is possible. IONICON invented the Switchable Reagent Ions (SRI) technology featuring NO + and O 2 + as additional precursor ions created in the new IONICON ULTRA-PURE ion source. The benefits are extraordinary as not only isomeric VOCs can be separated and instantaneously quantified but also substances with a smaller PA than the PA of H 2 O can now be detected with PTR-MS instruments. OUTSTANDING SENSITIVITY The High-Sensitivity PTR-QMS 500, our PTR-QMS series flagship product is incarnating the technological evolution of more than a decade s experience in PTR-MS we have at IONICON. With the 4 th generation of IONICON PTR-MS instruments, featuring technology such as the new ULTRA-PURE ion source and many other refinements, the new High-Sensitivity PTR-QMS 500 is the benchmark for extraordinary sensitivity and detection limit in the market. Up to 60.000.000 precursor ions are responsible for a break-through in real-time mass spectrometry: for the first time an IONICON PTR-MS instrument is capable of quantifying concentrations in the ppqv-range. Reagent ion yield (cps) 6x10 7 4x10 7 2x10 7 0 1M H 3 O + NO + O 2 + 10 M 40 M 60 M 50 M Typical PTR-MS 1 IONICON (past) IONICON (today) 1 R.S.Blake, P.S.Monks and A.M.Ellis, Chem.Rev., 109 (2009) 861. 4 th GENERATION PTR-MS The High-Sensitivity PTR-QMS 500 is the most sensitive commercial PTR-MS instrument available in the market and represents the 4 th and most advanced generation of the IONICON PTR-MS evolution. It is the successor of the world's bestselling PTR-MS system: the IONICON High-Sensitivity PTR-MS, of which various versions and generations are in use all over the world in more than 100 places. We provide flexible inlet solutions such as the integrated multi-position capability, calibration solutions and the possibility to optionally upgrade the PTR-QMS 500 series with multiplexing and data interface units thus bringing down the costs per sampling point and simplifying the integration in existing monitoring network infrastructure. IONICON Analytik GmbH Eduard-Bodem-Gasse 3 6020 Innsbruck Austria Tel.: +43 512 214 800 www.ionicon.com info@ionicon.com

SERIES THE WORLD s LEADING PTR-MS COMPANY PRESENTS LoD < 300 pptv The IONICON PTR-QMS 300 instrument is a real-time monitoring system for volatile organic compounds (VOCs) that allows for continuous VOC quantification at very low concentrations. The PTR-QMS series is based on quadrupole mass spectrometry and combines market-leading low online detection limits with high selectivity and a very fast response time. Direct injection of sample gases without preparation contributes to the speed and simplicity that is common to all our instruments. Mass Range 1-300 amu > Low detection limit < 300 pptv > Real-time VOC quantification > One-button touchscreen operation > Process monitoring and multiplexing ready Find out more: www.ionicon.com/products A modular software can be tailored to different industrial applications and individual, touchscreen operated monitoring solutions. The PTR-QMS 300 can optionally be equipped with multiplexing units. Our unique soft ionization (PTR) technology together with our extensive experience in gas-phase ion chemistry and engineering of scientific instruments accounts for the reliability, low detection limit, very low mass fragmentation, fast response time and robustness of our PTR-MS systems. THE SOLUTION FOR REAL-TIME TRACE GAS ANALYSIS

Picture: Rainer Sturm / pixelio.de PTR-QMS 3 00 IONICON PTR-QMS 300 SPECIFICATIONS* - Mass range: 1-300 amu - Resolution** < 1 amu - Response time: 100 ms - Detection limit**: 300 pptv - Linearity range**: 300 pptv - 10 ppmv - Adjustable flow: 50-500 sccm - Inlet system (Different inlet systems available on request): - 1.2 m long inlet hose - with internal inert (PEEK) capillary - Inlet system heating: up to 180 C (356 F) - Reaction chamber heating range: 40-130 C (104-266 F) - Power supply and max. consumption: 100-230 V, 1200 W - Dimensions (w x h x d): 56x61x53 cm (22.1x24.1x20.9 in.) - Weight (incl. SRI): 80 kg (177 lbs) - Main interfaces: 1x Touch screen display 1x Ethernet 10/100 Mbit RJ45 (TCP/IP) 8x DO, 4x DI, 4x AI, 4x AO touchscreen display allowing for one-button control of the system and even preconfigured analysis tasks in combination with an optional embedded industrial computer and individualized software packages (see Fig. 1). We provide flexible inlet solutions such as the integrated multi-position capability and the possibility to optionally upgrade the PTR-QMS 300 with multiplexing and data interface units thus bringing down the costs per sampling point and simplifying the integration in existing monitoring network infrastructure. For research or laboratory use the PTR-QMS 300 is available as a fully functional entry-level PTR-MS instrument, being operated using the comprehensive IONICON PTR-QMS series software suite, available on an external notebook computer (the touchscreen display then being used as status indicator). *Specifications are subject to change without prior notice. Product pictures and illustrations may differ from actual configuration. **Detection limit, linearity range and resolution are dependent on the substances measured, integration time and system set-up. TECHNOLOGY The innovative technology IONICON PTR-MS products are based on is Proton Transfer Reaction - Mass Spectrometry (PTR-MS). This unique soft ionization is realized by proton transfer from H 3 O + ions to all compounds with a higher proton affinity than water. Common constituents of air such as N 2, O 2, Ar, CO 2 etc. have lower proton affinities than H 2 O and are therefore not ionized. This is one of the main reasons for our market-leading low online detection limit for trace compounds and due to precisely controlled ion source and drift tube parameters, absolute quantification of VOC concentrations is possible. Fig. 1: Illustration of an automated monitoring software for different preset compounds and/or multiple sampling points. FEATURES The new IONICON PTR-QMS 300 is a milestone for time critical process monitoring applications that require outstanding sensitivity, speed and the selectivity of a quadrupole mass spectrometer. The PTR-QMS 300 is engineered as a very affordable, userand maintenance-friendly, lean and innovative bench top set-up that focuses on industrial applications. It features a Optionally available for all IONICON PTR-MS instruments: SRI (Switchable Reagent Ions) featuring NO + and O 2 + as additional precursor ions. Find out more about PTR+SRI-MS: www.ionicon.com/technology IONICON Analytik GmbH Eduard-Bodem-Gasse 3 6020 Innsbruck Austria Tel.: +43 512 214 800 www.ionicon.com info@ionicon.com