Dissolution Automation: Basic Questionnaire.

Similar documents
Application Note PB 401. Improve HPLC Sample Preparation in an Analytical Laboratory A New Automated Sample Preparation Process

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

SOPHAS - Speeding up the process of discovery and optimisation

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

Elemental Scientific. Spike Recovery. Elemental Scientific

Plop Plop, Fizz Fizz, Oh What A Relief It Is (Which Pain Reliever Works Fastest)

RINCIPLE OF COLORIMETER AND SPECTOPHOTOMETER AND VARIOUS TYPE OF ANALYSER USED IN CLINICAL BIOCHEMISTRY

Elemental Scientific. Stability. Elemental Scientific

ION CHROMATOGRAPHY IC-3000 SERIES EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Automatic titrators, TitroMatic

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

HPLC Praktikum Skript

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Varian Galaxie Chromatography Data System for Preparative HPLC

Chemistry Instrumental Analysis Lecture 31. Chem 4631

To assess product performance and the quality of

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

Multiphase Oscillatory Flow Strategy for in Situ Measurement and Screening of Partition Coefficients

Plop Plop, Fizz Fizz, Oh What A Relief It Is (Which Pain Reliever Works Fastest)

Cary 60 UV Dissolution Systems THE STANDARD FOR MULTICELL OR FIBER OPTIC DISSOLUTION TESTING

Protocol Particle size distribution by centrifugal sedimentation (CPS)

Biochemistry. Biochemical Techniques HPLC

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Spectroscopy in Transmission

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

ChromTech HPLC System

DI 3500 Discrete Aoalvzer

High Performance Liquid Chromatography

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

A LAZAR LABORATORY HANDBOOK MEASUREMENT OF NITRIC OXIDE IN BIOLOGICAL SAMPLES

Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences

Elemental Scientific. Spike Recovery. Elemental Scientific

ION CHROMATOGRAPHY SYSTEM S 150

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text.

T 282. WORKING GROUP CHAIRMAN Junyong Zhu SUBJECT

Nitrate Reductase (NR) Colorimetric Assay Kit

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

Comprehensive Polymer Analysis Strategies

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

Determination of Polymer Modifier in Asphalt

Determination of Caffeine by HPLC

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

DMA-80L TECHNICAL SPECIFICATIONS

Petroleum Thermodynamic Research Group

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

The solution for all of your

Degree of labeling (DOL)

A New Hyperspectral Spherical-Cavity Absorption Meter

Chapter content. Reference

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

Cyanide Analysis with the CNSolution 3100

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Method for Nitrite determination on Low-Range Samples

Spectrometer User s Guide

3590/ Laboratory

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

AFM1 (Aflatoxin M1) ELISA Kit


Which Optistat is right for you?

HIPPURIC ACID and o-m-p- METHYLHIPPURIC ACIDS IN URINE BY UV CODE Z06010

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Polyethylene Glycol (PEG), High Sensitive ELISA

Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Research Article. Dissolution Study of Oxolamine Citrate by UV Spectrophotometric Method in Pharmaceutical Dosage Form

The Plus for your lab!

How do you explain HPLC? 2 AZURA Educational System for tomorrow s HPLC professionals

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Pig immunoglobulin E (IgE) ELISA Kit

Pelagia Research Library

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Fasted State Dissolution Protocol

SPECIALIZED LABORATORY of pharmaceuticals manufacturing

25-OH VITAMIN D 3 AND 25-OH VITAMIN D 2 IN PLASMA BY UV / VIS FAST CODE Z19710

Chemistry 1210 Quantitative Determination of a Two-Component System

Instrumental Technique: Cuvette. Md Rabiul Islam

Notice Basic Information Estimated Contract Value (USD) $35, (Not shown to suppliers) Reference Number Issuing Organization

novaa 800 D Atomic Absorption Spectrometer

Human rheumatoid factor (RF) antibody (IgM) ELISA Kit

Concise laboratory catalogue

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

Dissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min.

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

SCANNING UV VISIBLE SPECTROPHOTOMETER

Automating Wet Chemical Analysis

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

Human anti-deoxyribonuclease B, anti-dnase B ELISA Kit

DISCLAIMER: This method:

SPECTROPHOTOMETERS. Visible and UV-Visible

EXPERIMENT: LIMITING REAGENT. NOTE: Students should have moles of reactants in DATASHEET converted into masses in grams prior to the lab period.

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Transcription:

Dissolution Automation: Basic Questionnaire. In order to quote the most suitable automated Dissolution System we would like you to answer this questionnaire: 1. Do you want to work : a) On line (on line is defined by a closed loop system with a spectrometer and multi-cell cuvette changer) c) Off line (off line is defined as working with a PTFC 2/12 fraction collector either with a peristaltic, syringe pump or piston pump - Sampling only) d) Off line including Sample Dilution (is defined as working with a DSR Sampling Robot or ASP 2000 Auto Sampler for direct online Dilution and/or dispensing into sealed Vials) e) Both or Hybrid System (is defined as an on line and off line: possible using PTFC 2 Fraction Collector and a Photometer with multi-cell changer) f) HPLC injection (requires auto sampler ASP2000 and injection system - communicates with HPLC for sample injection - data evaluation done by HPLC System software g) HPLC fully control system (requires auto sampler and injection system - communicates with HPLC system for sample injection and data transfer from integrator to WinDiss32 software. Reporting supplied by WinDiss32-V3 Dissolution program) h) In-Situ using Fiber Optics (does not need any pump or tubing - can measure each 15 seconds all 8 vessels, uses PDA Diode Array UV/VIS Photometer wavelength range either 200-6000 nm or 200-1000 nm) c ( ) d ( ) e ( ) g ( ) h ( ) 2. UV/VIS spectrophotometer If you want to work on line - closed loop, then which spectrometer do you wish to use? We recommend the use of a Diode Array Photometer such as the SA500 (full system responsibility from one supplier only) Answer:. (Spectrometer brand and type). Cell changer exists? Yes ( ) No ( ) if yes how many channels? 6 ( ) 7 ( ) 8 ( ) 16 ( ) 05-200730_09.1.0E Page 1 of 6

2a. Flow cells If you need flow cells for the spectrometer changer, do you have a preference? a) STARNA Optiglas, or b) Hellma QS c) which path length do you require? 0.1mm ( ) 0.5 mm ( ) 1.0 mm ( ) 5.0 mm ( ) 10 mm ( ) 20 mm ( ) or other 3. HPLC injection: If you want to inject samples on-line into a HPLC system, then which system do you wish to use? Answer: Isocratic Pump Type: Detector Type:. Software Suite and Version:. (pls. tell us brand and type - manufacturing year). 4. Sampling Method In terms of sampling, we have either in situ (sample probe remains always inside the media) or an Automatic manifold (EPE) which enters the solution with sampling probes only when the actual sampling is required. Do you have a preference? (This can affect the model type offered) a) In situ - (always in media sample probes) available for PT-DT7/70, DT8, PTWS100, or b) Auto Sampling System - EPE (only available for PTWS300/310, PTWS600/610, PTWS 1200/1210) 5. Filtration We have a choice of primary filters which are either 10 micron or 5 micron; which type is best suited? a) 10 micron, or b) 5 micron. c) other, like 0.45 micron c ( ) 05-200730_09.1.0E Page 2 of 6

Do you need any further filtering down to say 0.45 microns as your product changes colour of the dissolution media? 6. Dilution You may do Dilution at present when sampling manually and measuring the concentration in a UV/VIS spectrophotometer using a 10 mm cuvette. Using a closed loop (on-line) dissolution system Dilution can be avoided using various flow-cell sizes offering different path-length. The range includes flow-cell path length from 0.1 mm, 0.2 mm, 0.5 mm - 1mm, 2mm, 5mm and 10 mm. Using a 1 mm flow cell instead of the 10mm cuvette you are using in your manual method offers a dilution factor of 1:10. Which one will you require? none ( ) 1:10 ( ) 1:20 ( ) 1:50 ( ) 1:100 ( ) Do you need to dilute the sample from the very first sampling or later? need to dilute all the time ( ) need to dilute after.. hrs. ( ) 7. Online Dilution Besides the use a various path length cells its possible to Dilute the sample online if the DSR or ASP 2000 System is attached to the Dissolution Bath. a) The DSR Sampling Robot can be connected directly to a PTA Dissolution Bath Type DT8, PTWS 310, a PTWS 600/610, or a PTWS 1200/1210. There is no need to use a PC or software, sampling information is programmed via the keypad of the Dissolution Bath. Its also possible to attach the DSR to any other make of Dissolution Bath and program all sampling information using the DSR keypad. Only online injection into a Spectrophotometer is possible. http://www.pharma-test.de/en/products/p20_6.htm b) The ASP2000 Auto Sampling System can be connected to any Dissolution Bath. The entire System will be controlled by the WinDiss32 Software. Samples can be diluted and injected online into a connected Spectrophotometer or even a HPLC System http://www.pharma-test.de/en/products/p30_10.htm Which system will you prefer? Answer: System a) ( ) System b) ( ) 8. Absorbance problems Do any of your active materials react with or are absorbed by polypropylene? Answer: Yes ( ) No. ( ) (Filter material is PP) 05-200730_09.1.0E Page 3 of 6

9. Which tubing material do you need? We supply tubing for sample loops PTFE. Do you need any other material, like FEP? a) PTFE is fine b) Need other: 10. Sample transportation (pumps) For sample transportation, we can offer either a peristaltic pump or a piston pump. Within a closed loop system no media will be lost. The peristaltic pump is fine for closed loop (i.e., on line systems), but a piston pump is recommended for off line (Fraction collector) systems and auto samplers. This is because of the sure degradation with time of the peristaltic pump tubes which are under a lot of pressure during their working life. Fractions need to be accurately taken as they remove liquid from the dissolution vessels. Do you need : a) peristaltic b) piston pump. 11. Sampling only = off-line operation (PTFC 2 Fraction Collector) If you are working off line, would you like simultaneous refilling of the fraction which has been removed from the dissolution vessel (applies to peristaltic pumps only). Do you need refilling? http://www.pharma-test.de/en/products/p20_8.htm a) Yes b) No. 12. sampling and injection (Auto Sampler DSR and ASP 2000) Would you require refilling of the fraction which has been removed from the dissolution vessel? Do you need to dilute the sample previous to injection? Which Dilution do you need: 1:10 ( ) 1:20 ( ) 1:50 ( ) 1:100 ( ) 05-200730_09.1.0E Page 4 of 6

13. Media Change while dissolution testing Dissolution Automation: Basic Questionnaire Do you need to have medium exchange (applies to USP Apparatus 1 or 2 using Sinkers)? a) Yes b) No. 14. Dissolution Volume Do you need to work with larger dissolution volumes? We are able to offer a variety of larger vessels, not only the standard 1 liter version. Do you need: http://www.pharma-test.de/en/products/po10.htm a) 1 liter b) 2 liter c) 4 to 5 liter versions c ( ) 15. Media Degassing and Filling The use of degassed dissolution media is preferable, are you using a degassing system, which one? Remark: - Helium has relatively high running costs - Ultra Sonic is often insufficient as the volume you need to degas for a dissolution run is at least 6 ltr. - Heating, vacuum and filtration is very time consuming http://www.pharma-test.de/en/products/p10_11.htm a) Helium b) Ultra Sonic c) Heating, vacuum and filtration (FDA recommended) d) None c ( ) d ( ) 05-200730_09.1.0E Page 5 of 6

Please fill this questionnaire and return to: PHARMA TEST AG Siemensstrasse 5 D-63512 Hainburg (Germany) Fax: +49 6182 9532 650 Email: D.Beilke@pharma-test.de or S.Klassa@pharma-test.de PHARMA TEST AG, 2009/2010 05-200730_09.1.0E Page 6 of 6