AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS

Similar documents
Aqueous and polar GPC/SEC columns. Product guide

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

GPC/SEC standards. Product guide

GPC/SEC standards. Product guide

Practical Steps in GPC Method Development

GPC/SEC An essential tool for polymer analysis

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

CALIBRATING GPC COLUMNS

Organic GPC/SEC columns. Product guide

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Maximizing Performance Through GPC Column Selection

Polymer analysis by GPC-SEC. Technical Note. Introduction

Low molecular weight resins Analysis of low molecular weight. resins and prepolymers by GPC/SEC. Application compendium. Authors

Optimizing GPC Separations

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

LC and LC/MS Column Selection Flow Chart

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

GPC/SEC Start-up Kit

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

Comprehensive Polymer Analysis Strategies

An Introductions to Advanced GPC Solutions

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Sepax SRT -C, Zenix -C SEC Phases

GPC/SEC Column Selection & Method Development

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Gel Permeation Chromatography

for Acclaim Mixed-Mode HILIC-1 Column

Shodex TM ODP2 HP series columns

ProPac WCX-10 Columns

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Guide to Peptide Quantitation. Agilent clinical research

Cation Exchange HPLC Columns

Determination of Polymer Modifier in Asphalt

PHENOGEL GPC/SEC COLUMNS

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Analysis of polyolefins by GPC/SEC

Polymer Analysis by Gel Permeation Chromatography

GPC/MS. Analysis of PET

Application compendium. Authors. Greg Saunders, Ben MacCreath Agilent Technologies, Inc. A guide to multi-detector gel permeation chromatography

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

food testing & agriculture

C18 Column. Care & Use Sheet

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

Agilent 385-ELSD Evaporative Light Scattering Detector

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Agilent 385-ELSD Evaporative Light Scattering Detector

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

for Acclaim Trinity TM P1

LC Technical Information

GPC-/SEC-Columns. MZ-Gel SD. MZ-Gel Super FG SEC with fluorinated Eluents

Gel Permeation Chromatography - GPC

HPLC Sample Preparation

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

Basic Principles for Purification Using Supercritical Fluid Chromatography

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

WALKUP LC/MS FOR PHARMACEUTICAL R&D

GPC/SEC. VARIAN, INC. Engineering Polymers ANALYSIS OF ENGINEERING POLYMERS BY GPC/SEC.

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Solvent-Compatible High Performance GPC Columns: TSKgel HHR Series

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

High Performance Liquid Chromatography

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Products for GPC. Products for GPC. Size exclusion chromatography. Basic principles

Size Exclusion Chromatography: Method Development

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Gemini-NX Performance paired with Axia Technology

State-of-the-art C18 HPLC Columns

TSKgel Size Exclusion Chromatography Columns

Acclaim Mixed-Mode WCX-1

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Excipient analysis by GPC/SEC and other LC techniques

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Packings for HPLC. Packings for HPLC

Basic principles of HPLC

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

Method Development Kits

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

columns IonPac AS17-C Anion Exchange Column

How proteins separate on reverse-phase HPLC

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Transcription:

AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS

Contents Agilent GPC/SEC columns...3 InfinityLab PL Multisolvent...4 PL aquagel-oh SEC columns...7 PL Rapide Aqua columns...10 PL aquagel-oh preparative SEC columns...11 Agilent PolarGel GPC columns...12 Agilent Publications...14 Agilent GPC/SEC Analysis Systems...15 1976 1981 1984 1993 1999 PLgel columns, individual standards, and standard kits Polymer Laboratories founded to develop market-leading products for organic GPC/SEC PLgel MIXED columns, PL aquagel columns MIXED columns improve data quality, and novel chemistries for analysis of water-soluble polymers GPC software Dedicated software streamlines GPC/SEC calculations EasiCal standards New format shortens sample preparation time and the speed of calibration PL-GPC 220 instrument Market-leading high temperature GPC system for even the most difficult samples at temperatures up to 220 ºC 2

AGILENT GPC/SEC COLUMNS For molecular weight separation in aqueous and polar solvents Tough Agilent GPC/SEC columns set the standard for robustness and lifetime across a wide range of solvents and conditions. This uncompromising quality has made it the workhorse of the analytical industry for over 35 years. Inert The neutral surface and the ability to operate across a wide range of eluent conditions allows for high performance analyses of compounds with neutral, ionic and hydrophobic moieties. Fast The unmatched chemical and physical stability of Agilent's GPC/SEC media allows for wider pores and larger volumes, which translates to faster seperations, higher resolution, and reduced cost-of-analysis. 2004 2007 2009 2015 2017 PlusPore columns and EasiVial standards New chemistries deliver high-pore-volume materials for increased resolution, and EasiVial standards simplify calibration procedures even further PLgel Olexis columns Optimized for polyolefin analysis with highest resolution and data quality for even ultrahigh molecular weight samples 1260 Infinity Multi Detector Suite and PolarGel columns The 1260 Infinity MDS turns any LC into a powerful multi-detector GPC system, and PolarGel columns analyze polar samples in any solvent system The 1260 Infinity II Multi-Detector GPC/SEC System The first choice for accurate, reproducible polymer analysis. Select any combination of light scattering, viscometry and refractive index detection for absolute molecular weights and sizes. PL MultiSolvent GPC columns The newest addition to the InfinityLab GPC family, offering solvent flexibility for a variety of GPC analyses all on one column. 3

INFINITYLAB PL MULTISOLVENT High performance size exclusion chromatography across solvents Polymer-coated silica offers excellent resolution without sticking Special amphoteric surface chemistry is compatible with aqueous, polar organic, and nonpolar solvents and samples Short, efficient, and fast, these columns maximize instrument throughput and minimize labor costs 1e5 Characteristics: ph range: 2 to 8.5 Solvent compatibility: Water, Buffer, Chloroform, Dichloromethane, THF Typical Pressure: <200 bar (2900 psi) (aqueous buffer) Maximum Pressure: 400 bar (5800 psi) Maxiumum Temperature: 80 ºC Recommended Calibrants: For Aqueous Solvents: EasiVial PEG/PEO for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2080-0201 4 ml vials: PL2080-0200) For Polar Solvents: EasiVial PMMA for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2020-0201 4 ml vials: PL2020-0200) MW (g/mol) 1e4 THF Chloroform Dichloromethane 1e3 1e2 4 Retention time (min) 5 Polystyrene calibration curves in various solvents 1e6 chromatogram to come MW (g/mol) 1e5 1e4 THF Chloroform Dichloromethane 1e3 1e2 3 4 5 Polymethylmethacrlyate calibration curves in various solvents Retention time (min) 4

INFINITYLAB PL MULTISOLVENT Column: InfinityLab PL Multisolvent 30 4.6 x 150 mm Temperature: 25 ºC Solvent: Dichloromethane 8,000 2 95 1.3 95 dw/dlogm RI (nriu) dw/dlogm Ht (%) 0 0 Time (minutes) Fast separation of an epoxy sample in dichloromethane 8 0.1 1e1 1e2 MW distribution of epoxy sample Fitted MW (g/mol) 1e3 5 1e4 Column: InfinityLab PL Multisolvent 30 4.6x150 mm Temperature: 25 ºC Solvent: 10 mm NaH 2 PO 4 + 0.2 M NaNO 3 at ph 7 10 RI (mv) Ht (%) 0-2 5 6 7 Time (minutes) 0.1 1e2 1e3 Fitted MW (g/mol) 1e4 5 1e5 A switch to aqueous buffer and rapid analysis of dextrin MW distribution of dextrin sample 5

INFINITYLAB PL MULTISOLVENT Ordering information InfintyLab PL Multisolvent Description MW range (g/mol) (PEG/PEO) Guaranteed efficiency (p/m) Part No. InfintyLab PL Multisolvent 20, 4.6 x 150 mm up to 30,000 >145,000 PL1515-3321 InfintyLab PL Multisolvent 20, 4.6 x 50 mm PL1515-1321 InfintyLab PL Multisolvent 20, 7.8 x 150 mm PL1015-3321 InfintyLab PL Multisolvent 20, 7.8 x 50 mm PL1015-1321 InfintyLab PL Multisolvent 30, 4.6 x 150 mm 3,000 to 100,000 >145,000 PL1515-3323 InfintyLab PL Multisolvent 30, 4.6 x 50 mm PL1515-1323 InfintyLab PL Multisolvent 30, 7.8 x 150 mm PL1015-3323 InfintyLab PL Multisolvent 30, 7.8 x 50 mm PL1015-1323 Agilent InfinityLab Maximize Your LC Workflow Efficiency How can you make your LC workflow more efficient, so you can spend more time on your analytical priorities? Find out with Agilent InfinityLab an optimized portfolio of LC instruments, columns, and supplies designed to work together in perfect harmony. Learn more at: www.agilent.com/chem/infinitylab 6

PL AQUAGEL-OH SEC COLUMNS High performance aqueous size exclusion chromatography Highly stable matrix ensures reliable separations, even with modified eluents MIXED columns cover a wide spread of molecular weights, eliminating dislocations and inaccurate measurements Highly inert towards neutral, polar, anionic, and cationic samples Characteristics: ph range: 2-10 Solvent compatibility: Water and buffers containing up to 50% methanol Typical Pressure: <30 bar (435 psi) Maximum Pressure: 140 bar (2030 psi) Maxiumum Temperature: 90 ºC Recommended Calibrants: For PL aquagel-oh 5 µm columns: EasiVial PEG for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2070-0201 4 ml vials: PL2070-0200) For PL aquagel-oh 8 µm columns: EasiVial PEG/PEO for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2080-0201 4 ml vials: PL2080-0200) For PL aquagel-oh 15 µm columns: EasiVial PEG/PEO for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2080-0201 4 ml vials: PL2080-0200) 7 LogM 2 7 LogMW 30 40 20 50 60 5 Retention time/min 25 PL aquagel-oh MIXED 8 µm PL aquagel-oh 20 5 µm 2 5 Retention time/min 10 Tip: Polymers with MW over 2,000,000 are much more likely to suffer from shear degradation. This is largely eliminated by switching from 8 µm to 15 µm particles. PL aquagel-oh calibration curves 7

PL AQUAGEL-OH SEC COLUMNS Typical applications Heparin, gum, polyacrylic acid, polyacrylamide, pectin, dextran Columns: Eluent: Flow Rate: Detector: 3 x PL aquagel-oh MIXED 8 μm, 7.5 x 300 mm 0.2 M NaNO 3, 0.01 M NaH 2 PO 4, ph 7 1.0 ml/min PL-GPC 50 (RI) Columns: PL aquagel-oh 60 15 μm, 7.5 x 300 mm PL aquagel-oh 40 15 μm, 7.5 x 300 mm Eluent: 0.2 M NaNO 3, 0.01 M NaH 2 PO 4, ph 7 Flow Rate: 1.0 ml/min Detector: PL-GPC 50 (RI) Chromatogram 5 Retention time/min 18 1 10 min 33 Polyvinyl alcohol dw/dlog M Mw 1,800,00 g/mol Columns: 2 x PL aquagel-oh 30 8 μm, 7.5 x 300 mm Eluent: 0.2 M NaNO 3, 0.01M NaH 2 PO 4, ph 7 Flow Rate: 1.0 ml/min Detector: PL-GPC 50 (RI) 0 5 LogM 7 Hyaluronic acid Columns: 2 x PL aquagel-oh 20 5 µm, 7.5 x 300 mm Eluent: 0.25 M ammonium formate in water Flow Rate: 1.0 ml/min Inj. Vol: 20 µl Software: Agilent GPC/SEC software Detector: Agilent ELS (neb = 30 C, evap = 30 C, gas = 1.4 SLM) 8 1 5 Retention time/min 22 Heparin dw/dlog M Cum.Ht 8 0 1.0 LogM Differences in composition of two alkyl naphthalene sulfonates 3.5 0

PL AQUAGEL-OH SEC COLUMNS Ordering information PL aquagel-oh columns, 7.5 x 300 mm Description Particle size (µm) MW range (g/mol) (PEG/PEO) Guaranteed Efficiency (p/m) Part No. PL aquagel-oh 20 5 100 to 20,000 >55,000 PL1120-6520 PL aquagel-oh 30 8 100 to 60,000 >35,000 PL1120-6830 PL aquagel-oh 40 8 10,000 to 200,000 >35,000 PL1149-6840 PL aquagel-oh 40 15 10,000 to 200,000 >15,000 PL1149-6240 PL aquagel-oh 50 8 50,000 to 600,000 >35,000 PL1149-6850 PL aquagel-oh 50 15 50,000 to 600,000 >15,000 PL1149-6250 PL aquagel-oh 60 8 200,000 to 10,000,000 >35,000 PL1149-6860 PL aquagel-oh 60 15 200,000 to 10,000,000 >15,000 PL1149-6260 PL aquagel-oh MIXED-H 8 6,000 to 10,000,000 >35,000 PL1149-6800 PL aquagel-oh MIXED-M 8 1,000 to 500,000 >35,000 PL1149-6801 Ordering information PL aquagel-oh analytical column accessories Description Quantity (pk) Part No. Frit removal tool for threaded columns only 1 PL1310-0001 Frit (2 μm) kit for threaded columns, 5 PL1310-0002 7.5 mm id Frit (5 μm) kit for threaded columns, 5 PL1310-0012 7.5 mm id Column connecting nuts, 1/16 in. tube 5 PL1310-0007 Tubing ferrules, 1/16 in. tube 5 PL1310-0008 LDV intercolumn SS connector 1 PL1310-0005 Connecting tubing, 10 cm length, 0.01 in. id 10 PL1310-0048 Ordering information PL aquagel-oh Guard columns Description Particle size (µm) id (mm) Length (mm) Part No. PL aquagel-oh Guard 10 25.0 25 PL1249-1120 PL aquagel-oh Guard 5 7.5 50 PL1149-1530 PL aquagel-oh Guard 8 7.5 50 PL1149-1840 See also: Polymer Calibration Standards, with highly characterized molecular weights, publication 5990-7996EN 9

PL RAPIDE AQUA COLUMNS Fast separations on high dispersion systems Maximize throughput when using older systems or multiple detectors High sample throughput reduces labor costs per sample Net savings of solvents due to reduced analysis time Characteristics: ph range: 2-10 Solvent compatibility: Water and buffers containing up to 50% methanol Typical Pressure: <30 bar (435 psi) Maximum Pressure: 140 bar (2030 psi) Maxiumum Temperature: 90 ºC Recommended Calibrants: For PL Rapide L columns: EasiVial PEG for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2070-0201 4mL vials: PL2070-0200) For PL Rapide H columns: EasiVial PEG/PEO for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2080-0201 4mL vials: PL2080-0200 Typical applications Sodium acrylate Column: PL Rapide Aqua H, 7.5 x 150 mm Eluent: Water + 0.2 M NaNO 3, 0.01 M NaH 2 PO 4, ph 7 Flow rate: 1.0 ml/min Detector: RI 0 Retention time/min 7 Sodium acrylate Ordering information PL Rapide Aqua columns Description MW range (g/mol) Guaranteed efficiency (p/m) Part No. PL Rapide Aqua H, 7.5 x 150 mm 6,000 to 10,000,000 >35,000 PL1149-3800 PL Rapide Aqua H, 10 x 100 mm 6,000 to 10,000,000 >35,000 PL1049-2800 PL Rapide Aqua L, 7.5 x 150 mm 100 to 60,000 >35,000 PL1120-3830 PL Rapide Aqua L, 10 x 100 mm 100 to 60,000 >35,000 PL1020-2830 10

PL AQUAGEL-OH PREPARATIVE SEC COLUMNS Rapid and convenient scale-up Up to 10 x scale-up for milligram to gram quantities Efficient 8 µm particles offer greater speed, purity, and recovery High pore volume maximizes loadability Preparative PL aquagel-oh columns use the same 8 µm particles as standard columns. This enables rapid and reliable scale-up from analytical to preparative separations. The analytical grade 8 µm media offer much higher effieciency than conventional large particle SEC and GFC columns. This efficiency results in fast separations to maximize throughput, and sharp peak shape to maximize purity and yield from each cut. Typical applications Fractionation of disperse polymers, component isolation Column: PL aquagel-oh 40 8 µm, 25 x 300 mm Eluent: 0.2M NaNO 3, 0.01M NaH 2 PO 4, ph 7 Flow Rate: 10.0 ml/min Loading: 10 mg/ml, 2 ml Detector: RI 0 Retention time/min 15 Polyvinyl alcohol Ordering information PL aquagel-oh preparative columns 8 µm, 25 x 300 mm Description MW range Part No. (g/mol) (PEG/PEO) PL aquagel-oh 30 100 to 60,000 PL1220-6130 PL aquagel-oh 40 10,000 to 200,000 PL1249-6140 PL aquagel-oh 50 50,000 to 600,000 PL1249-6150 PL aquagel-oh MIXED 6,000 to 10,000,000 PL1249-6100 PL aquagel-oh Guard, 25 x 25 mm PL1249-1120 11

AGILENT POLARGEL GPC COLUMNS For intermediate polarity solvents and polar solvent combinations Eliminates the risk of interactions and bad data when using in high polarity solvents such as DMSO, NMP, DMAc, and DMF High efficiency and resolution maximizes sample throughput Excellent stability and lifetime in challenging polar solvents and at elevated temperatures Highly polar groups present on some polymers can lead to nonspecific interactions and secondary separation mechanisms when using polar solvents. These secondary effects result in distorted chromatograms and inaccurate MW data. PolarGel mixed bed columns have a medium polarity surface and high mechanical stability. They are capable of operating in a wide range of solvents and solvent combinations, greatly enhancing their ability to analyze polar polymers that are not soluble in traditional aqueous or organic solvents. Characteristics: ph Range: 2-10 Solvent Range: THF to Water Particle Size: 8 μm Efficiency: >35,000 p/m Typical Pressure: <30 bar (435 psi) Maximum Pressure: 140 bar (2030 psi) Maximum Temperature: 80 ºC Recommended Calibrants: For Polar Solvents: EasiVial PMMA for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2070-0202 4 ml vials: PL2070-0203) For Polar/Aqueous Solvents: EasiVial PEG/PEO for convenient 12 point calibration in three preweighed vials (2 ml vials: PL2080-0201 4 ml vials: PL2080-0200) Columns: 2 x PolarGel-M, 7.5 x 300 mm Sample: Melamine resins Eluent: Dimethylformamide + 0.1% LiBr Flow Rate: 1.0 ml/min Temp: 50 C Detector: RI PolarGel-M columns Styrene/divinyl benzene columns Polymer Shoulder Oligomer 5 Retention time/min 20 Superior polar performance from PolarGel columns Columns: 2 x PolarGel-L, 7.5 x 300 mm Eluent: Dimethylformamide + 0.1% LiBr Flow Rate: 1.0 ml/min Inj Vol:: 100 μl Temp: 50 C Detector: RI Retention time/min 0 22 Two samples of melamine resin analyzed by PolarGel-L Tip: Buffers in a stored column may crystallize out and cause damage, so flush out the column with water containing a small amount of sodium azide, to prevent biological growth. 12

AGILENT POLARGEL GPC COLUMNS Ordering information PolarGel columns Description MW range (g/mol) Guaranteed efficiency (p/m) Part No. PolarGel-L, 7.5 x 300 mm 100 to 60,000 >35,000 PL1117-6830 PolarGel-M, 7.5 x 300 mm 1,000 to 500,000 >35,000 PL1117-6800 Ordering information PolarGel Guards 7.5 x 50 mm Description PolarGel-L Guard column, 7.5 x 50 mm PolarGel-M Guard column, 7.5 x 50 mm Part No. PL1117-1830 PL1117-1800 Columns: 2 x PolarGel-L, 7.5 x 300 mm Eluent: Dimethylformamide + 0.1% LiBr Flow Rate: 1.0 ml/min Inj Vol:: 100 μl Temp: 50 C Detector: RI Retention time/min 0 22 Two samples of melamine resin analyzed by PolarGel-L Tip: Filter samples through a 0.45 µm filter prior to injection to extend column lifetime. 13

AGILENT PUBLICATIONS Further reading GPC/SEC publication Primers An introduction to gel permeation chromatography and size exclusion chromatography Calibrating GPC/SEC columns - a guide to best practice Step-by-step method development in GPC Polymer-to-solvent reference table for GPC/SEC Instrument setup for Fast GPC Application compendia Analysis of polymers by GPC/SEC - energy & chemicals applications Analysis of polymers by GPC/SEC - food applications Analysis of polymers by GPC/SEC - pharmaceutical applications Excipient analysis by GPC/SEC and other LC techniques Biodegradable polymers - analysis of biodegradable polymers by GPC/SEC Analysis of engineering polymers by GPC/SEC Analysis of elastomers by GPC/SEC Analysis of polyolefins by GPC/SEC Low molecular weight resins - Analysis of low molecular weight resins and prepolymers by GPC/SEC Product guides Aqueous and polar GPC/SEC columns GPC/SEC standards Publication number 5990-6969EN 5991-2720EN 5991-7272EN 5991-6802EN 5991-7191EN 5991-2517EN 5991-2029EN 5991-2519EN 5990-7771EN 5990-6920EN 5990-6970EN 5990-6866EN 5990-6971EN 5990-6845EN 5990-7995EN 5990-7996EN Agilent GPC/SEC calibration standards Calibrating your GPC/SEC columns with the highest quality polymer standards, Agilent EasiVial and Agilent EasiCal, ensures superior results and boosts productivity through: Improved reproducibility Improved resolution, leading to better accuracy Earlier detection of problems Reduced trouble-shooting and system downtime Statistically significant analysis of the system To learn more about calibrating your GPC columns, refer to the primer Calibrating GPC Columns - A Guide to Best Practice (5991-2720EN). Get your copy, and find other useful documents at www.agilent.com/chem/gpcresources 14

AGILENT GPC/SEC ANALYSIS SYSTEMS The Agilent 1260 Infinity II GPC/SEC system and 1260 Infinity II Multi-Detector GPC/SEC system are part of Agilent InfinityLab, an optimized portfolio of LC instruments, columns and supplies that work together seamlessly for maximum efficiency and performance. The Agilent 1260 Infinity II GPC/SEC system has been designed to meet the challenges of today s polymer analyst. The system features the new Infinity II refractive index detector for exceptional improvements in resolution and speed. The newly developed vialsampler offers higher unattended sample throughput, while the multicolumn thermostat provides accurate temperature control to minimize detector noise and baseline drift. The updated isocratic pump allows for extra flow precision to maximize reproducibility and accuracy in MW measurements. The Agilent 1260 Infinity II Multi-Detector GPC/SEC system is the first choice for accurate, reproducible polymer analysis. Select any combination of light scattering, viscometry and refractive index detection for absolute molecular weights and sizes. The system provides a wealth of information regarding polymer structure and it is also possible to identify and quantify properties such as branching which can influence processing and physical properties. Precise temperature control minimizes equilibration time and maximizes sample throughput. Innovative InfinityLab supplies that simplify your work Handle mobile phases with ease using ergonomic, easy-grip solvent bottles Prevent harmful solvents from leaching into the air with InfinityLab Stay Safe caps Safely control solvent drainage with InfinityLab Anti-Drain Fitting Ensure leak-free column connections with InfinityLab Quick Connect Fittings 15

Calibration is key to generating reliable and accurate GPC data. To learn more, refer to the primer: Calibrating GPC Columns A Guide to Best Practice Publication 5991-2720EN Learn more www.agilent.com/chem/gpcresources Buy online www.agilent.com/chem/store Find a local Agilent customer center in your country www.agilent.com/chem/contactus USA and Canada 1-800-227-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com India india-lsca_marketing@agilent.com This information is subject to change without notice. Agilent Technologies, Inc. 2017 Printed in the USA July 1, 2017 5990-7995EN