Protein Sequencer PPSQ-31A / 33A C297-E055B

Similar documents
Spectrophotometer for Life Science. BioSpec-nano C101-E112D

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

Chiral Separation Using SFC and HPLC

C146-E209. Headspace Samplers. HS-20 Series

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Single Nano Particle Size Analyzer

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Consumables Guide for the Cannabis Testing Lab

The solution for all of your

Agilent G2350A Atomic Emission Detector (AED)

Fusion UV/Persulfate TOC Analyzer

883 Basic IC plus. The smallest Metrohm ion chromatograph

Micro Volume QuEChERS kit

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Orbit Support Pack for Excel. user manual

Subject: Cycle Modification on the ABI 3900 DNA Synthesizer using software v1.2

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Fusion UV/Persulfate TOC Analyzer

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Analyst Software. Peptide and Protein Quantitation Tutorial

FLASH CHROMATOGRAPHY

Application Note. Capillary Zone Electrophoresis

Thermo Finnigan LTQ. Specifications

Esterification in a PFR with Aspen Plus V8.0

JAPAN QUALITY. Automated Clinical Analyzer

Rapid Distinction of Leucine and Isoleucine in Monoclonal Antibodies Using Nanoflow. LCMS n. Discovery Attribute Sciences

GAS CHROMATOGRAPHY (GC)

Varian Galaxie Chromatography Data System for Preparative HPLC

Preparative Separation of Active Components from Natural Products using Low-pressure Gradient Preparative HPLC

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

COMPREHENSIVE LC X LC ANALYSIS OF FLAVORING INGREDIENTS IN DISTILLED SPIRITS

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

C101-E145 TALK LETTER. Vol. 17

ION CHROMATOGRAPHY SYSTEM S 150

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

How do you explain HPLC? 2 AZURA Educational System for tomorrow s HPLC professionals

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Application Note. No. 51. Visualization of Progress of Internal Damage in Carbon Fiber Composite Materials and Mechanism of Impact Strength

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

ISSP User Guide CY3207ISSP. Revision C

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Energy Dispersive X-ray Fluorescence Spectrometer for RoHS/ELV Screening EDX-GP / LE C142-E035A

ChromTech HPLC System

Nanoparticle Analyzer

FoodScreen Radiological Food Screening System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Peptide Isolation Using the Prep 150 LC System

Technology that counts

25-OH VITAMIN D 3 AND 25-OH VITAMIN D 2 IN PLASMA BY UV / VIS FAST CODE Z19710

JAPAN QUALITY. Automated Clinical Analyzer

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

TL6 Ultra Micro-volume Spectrophotometer

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Automatic titrators, TitroMatic

Rapid Catalyst Screening Reactors

Expanded capabilities in ammonium and amine detection

Analyst Software. Automatic Optimization Tutorial

Fast and Accurate Analysis of Fluorotelomer Alcohols and Acrylates using Triple Quadrupole GC-MS/MS

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

Finnigan LCQ Advantage MAX

The Plus for your lab!

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

+ butanal + 2-picolineborane. + acetic acid. + butanal + 2-picolineborane. + acetic acid

Screening of pesticides in water using SPE on line

Successfully Scaling and Transferring HPLC and UPLC Methods

Esterification in CSTRs in Series with Aspen Plus V8.0

Technology that counts

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

A new chapter. medicacorp.com

symphony Reference Electrodes

Technical Data Sheet: Thermokinetics 3

Pressure Swing Distillation with Aspen Plus V8.0

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Spectrometer User s Guide

Investigation reply tool operation manual

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

25-OH VITAMIN D 3 IN PLASMA BY UV FAST CODE Z19610

Calibration and Normalization of MALS Detectors

Gas Chromatograph Mass Spectrometer GCMS-TQ8040 C146-E251

DR/4000 PROCEDURE. IRON, Total

mylab: Chemical Safety Module Last Updated: January 19, 2018

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

genesig Easy q16 Validation kit

3-METHYL INDOLE (Skatole) IN URINE BY FLUORIMETRY FAST - Code Z60010

ncounter PlexSet Data Analysis Guidelines

User's Manual. Chemical software Acid-base equilibria for Windows. ABEW Version Windows XP - Windows Vista - Windows 7 - Windows 8 - Windows 10

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Transcription:

Protein Sequencer PPSQ-31A / 33A C297-E055B

Protein Sequencer PPSQ-31A / 33A Achieving Greater Simplicity and Reliability in the Determination of Amino Acid Sequences

Analytical Stability Excellent baseline stability and retention time reproducibility P. 4 Repeated Use of Mobile Phase Reduced running costs and liquid waste in the analysis of PTH-amino acids using isocratic mode P. 5 Software with Excellent Operability Simple operations and easy-to-use data analysis functions P. 5

Analytical Stability Baseline Stability PPSQ series protein sequencers separate PTH-amino acids isocratically. This improves baseline stability and allows high-sensitivity analysis of PTH-amino acids. Retention Time Reproducibility Isocratic sequence analysis provides more stable retention times. Therefore, peaks detected in previous cycles can be cancelled using substation chromatogram processing, making it easier to identify sequences. 2.00 1.75 1.50 1.25 1.00 0.75 0.50 0.25 mv D E N Q S T H G A Y R M V P -0.25 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 min W F PTH-AA K I L 10pmol Spot 1 Analysis Examples for Spot 1 (The results for cycle 2 onwards are subtraction chromatograms.) 2D Electrophoresis Image of Proteins Extracted from E. Coli cycle 1 cycle 2 1.0 mv DTT 1.0 mv 0.8 0.8 0.6 S 0.6 T 0.4 0.4 0.2 DPU 0.2 DTT 0.0 0.0 cycle 14 cycle 15 0.50 mv 0.50 mv 0.40 0.40 0.30 0.30 DTT Y 0.20 0.10 L 0.20 0.10 cycle 24 cycle 25 0.50 mv 0.50 mv 0.40 0.40 0.30 0.30 0.20 0.10 E DTT 0.20 0.10 DTT K 4

Repeated Use of Mobile Phase Analysis of PTH-Amino Acids Using Isocratic Mode Performing PTH-amino acid analysis in an isocratic mode in which eluents are recycled to allow repeated use of the mobile phase makes it possible to reduce liquid waste and running costs. Software with Excellent Operability Simple Operations Specialized protein sequencer software incorporating control functions for the reaction unit and HPLC analysis unit makes it easy to perform sequence analysis. Main Window Selection of sequencing schedule Summary display of currently executed cycle and step and estimated completion time Sequence Schedule Window Reagent Control Window Sequence analysis can be started by simply registering the number of analysis cycles, data file names, and other information, and then clicking the [Start] button. When a reagent is replaced, the inside of the reagent bottle is purged with nitrogen. The replacement dates and times of the reagents can be ascertained with a glance, and lot control is possible. PPSQ-31A / 33A Protein Sequencer 5

Simpl e, Eas y - t o- U s e D a t a A na l y s is F u n ctio n s Specialized protein sequencer software makes it simple to perform the reprocessing of chromatograms, the overlay of multiple chromatograms, and the automatic estimation of amino acid sequences, which are required for sequence analysis. R ep ro c e s s in g o f c h ro mato g ra m s re q u ire d fo r d ata a n a ly s is A ut om at ic es t im a ti on of am ino ac id s equences Chromatogram peak integration, printing, and other processes can be performed on a per-sample basis. Displays multiple chromatograms. Analysis cycles can be updated simply by clicking a button. Window allows easy identification of sequences. Calibrates PTH-amino acids. Retention times can be edited simply by selecting a PTH-amino acid and clicking a peak. Automatically generates a report containing analytical parameters, estimated sequences, yield rates, and other information. Au to mati c Seq u e n ce Es ti mati o n If the appropriate settings are entered before analysis starts, sequences are automatically estimated after each cycle is complete. Up to four candidate amino acids are displayed together with their certainty levels. 6 O ver lay of m ult iple c hrom at ogr am s C u s t o m ized Repor t s Yield G r aph D is play Reports containing information such as analytical parameters, estimated sequences, and yield rates are automatically created. Initial and repeated yield rates are calculated and displayed in graph form. Amino acids used for calculations can be freely selected.

Specifications Main Unit Reaction method Reaction time Number of reactors PPSQ-31A/33A Edman degradation PPSQ-31A: 47 min/cycle PPSQ-33A: 48.5 min/cycle PPSQ-31A: 1 PPSQ-33A: 3 Sample immobilization method Glass fiber disk (8 mm dia.) or PVDF membrane Reactor temperature control Room temperature + 10 C to 60 C Converter temperature control Room temperature + 10 C to 70 C Column temperature control Room temperature + 10 C to 60 C Number of reagents/solvents 8 (one is an option) Reagent/solvent delivery method Nitrogen gas pressure Dimensions W650 D500 H520 mm Weight PPSQ-31A: 55 kg Solvent Delivery Module Flow rate setting range Dimensions Weight Detector Wavelength setting range Dimensions Weight Control PC Computer Display LC-20AT 1 to 10 ml/min W260 D420 H140 mm 11 kg SPD-20A 190 to 700 nm W260 D420 H140 mm 13 kg IBM PC/AT or compatible OS: Windows XP, Windows 7 17-inch LCD Note: In the interests of product improvement, these specifications may change without notice. Note: Windows is a registered trademark of Microsoft Corporation in the U.S. and other countries. Startup Kit Part name Quantity Reagents for amino acid sequence analysis (7 types) 1 of each type Glass fiber disks 50 Polybrene reagent 1 Apomyoglobin standard 1 Mobile phase for PTH-amino acids 1 L Separation column for PTH-amino acids 1 Mixed standards for PTH-amino acids 2 ml x 4 Note: The startup kit is for initial installation. To order additional reagents, contact Wako Pure Chemical Industries, Ltd. Other Items Provided by User Installation space Power supply Nitrogen gas Exhaust equipment Desktop: W1,730 D600 H550 mm min. (Weight: Approx. 93 kg) 100 VAC, 1,100 VA, 50/60 Hz Purity: 99.9999% min. A cylinder pressure regulator and gas tubing (10 m) are provided as standard accessories. In order to provide an exhaust for gases produced by waste liquids, an exhaust tube must either be connected to exhaust equipment or led outside. An exhaust tube (20 m) is provided as a standard accessory. Note: The required installation space and power supply may change according to the PC and display used. Standard Configurations PPSQ-31A System Part number Part name 292-31310-XX PPSQ-31A (main unit) LC-20AT SPD-20A PPSQ-30 (control PC set) 292-05684-92 Startup kit PPSQ-31A Single Reactor Offers highly cost-effective performance. PPSQ-33A System Part number 292-31330-XX 292-05684-92 Part name PPSQ-33A (main unit) LC-20AT SPD-20A PPSQ-30 (control PC set) Startup kit PPSQ-33A Triple Reactor (Supports consecutive analysis of 3 samples.) Using a triple reactor makes it possible to save time and effort, and gives greater freedom in the formulation of analysis programs. PPSQ-31A / 33A Protein Sequencer 7

PPSQ-31A / 33A Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2013 Printed in Japan 3655-05318-30AMF