Geology 777 Monte Carlo Exercise I

Similar documents
Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

EDS User School. Principles of Electron Beam Microanalysis

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Basic structure of SEM

Modern Optical Spectroscopy

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Task 1: Open ArcMap and activate the Spatial Analyst extension.

NIST DTSA-II ( Son of DTSA ): Step-by-Step

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

EGS: Lab Activities. Virtual Visitor Center at SLAC

h p λ = mν Back to de Broglie and the electron as a wave you will learn more about this Equation in CHEM* 2060

HOW TO APPROACH SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE SPECTROSCOPY ANALYSIS. SCSAM Short Course Amir Avishai

DAY LABORATORY EXERCISE: SPECTROSCOPY

Spectroscopy II Introduction: Spectrophotometry and Fluorometry

2: SIMPLE HARMONIC MOTION

AP5301/ Name the major parts of an optical microscope and state their functions.

Monte Carlo simulation of electron-solid interactions in cement-based materials

2: SIMPLE HARMONIC MOTION

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

Massachusetts Institute of Technology. Dr. Nilanjan Chatterjee

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Depth Distribution Functions of Secondary Electron Production and Emission

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

Relative Photometry with data from the Peter van de Kamp Observatory D. Cohen and E. Jensen (v.1.0 October 19, 2014)

Standards-Based Quantification in DTSA-II Part II

Setting The motor that rotates the sample about an axis normal to the diffraction plane is called (or ).

X-RAY SPECTRA. Theory:

Sample Alignment (2D detector) Part

Understanding X-rays: The electromagnetic spectrum

Introduction to EDX. Energy Dispersive X-ray Microanalysis (EDS, Energy dispersive Spectroscopy) Basics of EDX

Monte Carlo study of medium-energy electron penetration in aluminium and silver

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

Concentrations that absorb. Measuring percentage transmittance of solutions at different concentrations

Computer simulation of radioactive decay

CBE Science of Engineering Materials. Scanning Electron Microscopy (SEM)

Standards-Based Quantification in DTSA-II Part I

THERMAL RADIATION. The electromagnetic radiation emitted by a hot tungsten filament will be studied.

Using Microsoft Excel

LAB 01 X-RAY EMISSION & ABSORPTION

Auger Electron Spectroscopy

Sample Alignment Part

The Method of Increasing COMPO Contrast by Linearization of Backscattering Characteristic η =f(z)

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

4. Inelastic Scattering

Tutorial 23 Back Analysis of Material Properties

Understanding X-rays: The electromagnetic spectrum

Overview: In this experiment we study the decay of a radioactive nucleus, Cesium 137. Figure 1: The Decay Modes of Cesium 137

LAB 3 INSTRUCTIONS SIMPLE LINEAR REGRESSION

Chapter 9. Electron mean free path Microscopy principles of SEM, TEM, LEEM

5-Sep-15 PHYS101-2 GRAPHING

Designing a Quilt with GIMP 2011

Application Note. Capillary Zone Electrophoresis

SteelSmart System Cold Formed Steel Design Software Download & Installation Instructions

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

Lecture 22 Ion Beam Techniques

Motion II. Goals and Introduction

Semiconductor Optoelectronics Prof. M. R. Shenoy Department of physics Indian Institute of Technology, Delhi

Assignment #0 Using Stellarium

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

EDAX Microanalysis Course. Tasks

Within this document, the term NHDPlus is used when referring to NHDPlus Version 2.1 (unless otherwise noted).

Absorption of X-rays

Thermal Effect Behavior of Materials under Scanning Electron Microscopy. Monte Carlo and Molecular Dynamics Hybrid Model.

Charge to Mass Ratio of the Electron

Auger Electron Spectroscopy (AES) Prof. Paul K. Chu

Lateral sensitivity in electron probe microanalysis studied by Monte Carlo simulations involving fluorescence enhancements

Using the Stock Hydrology Tools in ArcGIS

Watershed Modeling Orange County Hydrology Using GIS Data

Everhart-Thornley detector

Linear Motion with Constant Acceleration

Size Determination of Gold Nanoparticles using Mie Theory and Extinction Spectra

Photoluminescence Spectrometer (FLS980)

Analysis of Insulator Samples with AES

Displaying Latitude & Longitude Data (XY Data) in ArcGIS

SEM. Chemical Analysis in the. Elastic and Inelastic scattering. Chemical analysis in the SEM. Chemical analysis in the SEM

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Jasco V-670 absorption spectrometer

STATISTICAL HANDLING OF RADIOACTIVITY MEASUREMENTS

Building Inflation Tables and CER Libraries

Athena Visual Software, Inc. 1

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Date: Summer Stem Section:

MITOCW watch?v=wr88_vzfcx4

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

This experiment is included in the XRP 4.0 X-ray solid state, XRS 4.0 X-ray structural analysis, and XRC 4.0 X-ray characteristics upgrade sets.

theoretical practice on grazing-exit energy dispersive X-ray spectroscopy as a surface analysis

Momentum & Collisions

Lesson Plan 2 - Middle and High School Land Use and Land Cover Introduction. Understanding Land Use and Land Cover using Google Earth

REPLACE DAMAGED OR MISSING TEXTBOOK BARCODE LABEL

LECTURE 15: SIMPLE LINEAR REGRESSION I

module, with the exception that the vials are larger and you only use one initial population size.

Lab 1 Uniform Motion - Graphing and Analyzing Motion

Standardless Analysis by XRF but I don t know what s in my sample!! Dr Colin Slater Applications Scientist, XRF Bruker UK Limited

SFT3000S Measurement of Sn-Cu Coating

Interactions with Matter

XUV 773: X-Ray Fluorescence Analysis of Gemstones

k T m 8 B P m k T M T

The Flow of Energy Out of the Sun

Transcription:

Geology 777 Monte Carlo Exercise I Purpose The goal of this exercise is to get you to think like an electron... to start to think about where electrons from the stream of high energy electrons go when they hit the metal or mineral or semi-conductor or glass that you are analyzing. Where do the electrons go in the process of generating x-rays? How big of a region do the x-rays come from? What factors govern the size of this interaction region? (Think... spatial resolution). Do all x-rays in your sample come from the same region? Do the backscattered elections come from the same region? What about secondary electrons? For the hard core.consider looking at the 1991 Scanning Microscopy paper by David Joy (An Introduction to MC Simulations; go to class website and navigate to folder with papers, then to specific Journal) to get a better general understanding of what these programs are modeling. This week you will run electron-solid Monte Carlo simulations with the CASINO (Windows) 1 application. It can be downloaded from its homesite www.gel.usherbrooke.ca/casino/. The name is from monte CArlo SImulation of electron trajectory in solids, and was originated by Raynald Gauvin of Univ of Sherbrooke (Quebec). Download only the v2.48 version! (Not the newer version v3.2 which is a 3d simulation which no one here has yet figured out how to run!) Unzip it and be sure to run it from a folder/directory which contains the int folder at the same level as the.exe file. Note: there is an article in 2007 Scanning on this program which you might consider looking at (posted on the class website): Drouin et al, 2007, CASINO V2.42 - A fast and easy-to-use modeling tool for scanning electron microscopy and microanalysis users. The program models both the electron scattering and the X-ray production by those electrons, and is useful for determining what kind of accelerating voltage must be used to keep the electrons and the x-rays within the top layer. Remember that is takes more energy to produce an X-ray than the actual energy of said X-ray (ex: Si-Kα X-ray = 1.74 kev, Si K absorption edge = 1.84 kev) It is set up to simulate both bulk specimens, plus a thin films (could be more than one) over a substrate You have 3 problems to run for your assignment: Compare the electron scattering and x-ray generation in (1) Si and (2) Au solids. (3) Look at a thin film. Background: Using resources 2 at hand, fill in the blanks: can 15 kev beam excite this line? Si Ka characteristic energy kev minimum excitation (edge) energy for this kev Y N Au Ka chacteristic energy kev minimum excitation (edge) energy for this kev Y N Au La chacteristic energy kev minimum excitation (edge) energy for this kev Y N Au Ma chacteristic energy kev minimum excitation (edge) energy for this kev Y N I. Bulk Sample of Si metal Instructions for bulk samples: 1. Run Casino v. 2.48 1 If you use a Mac computer, you will either need to use a Windows emulation program on it, or find a windows computer for this and many of the other programs you will need to run for this class. There is a standalone windows computer in Weeks 306 which you may use. 2 Tables 14.6, 14.7, 14.8 from Goldstein et al, distributed first day of class. Or relevant tables in Orange X-ray book handed out Class 1. Page 1 11/19/15

2. File-> New, automatically opens Edit Layers dialog box, click Add Layer, then select the Undefined (=Substrate) and for Composition, type in Si (case sensitive) and it should put in the proper density for the metal (note: it will NOT give the correct density for non-metals, and you will need to manually enter correct values). Click Done. Then click Next. 3. You are now in the Microscope and Simulation Properties dialog box. There are only 3 things to edit here: a. Define the accelerating voltage (we only use a constant one): change from 1 to 15 kv, b. Number of electrons to simulate, default is 200, but really gives poor statistics. (Set to 2000; you will want to run 10 thousand or more runs.) c. Beam radius (nm): default is 10 nm which might be for a low current (50 pa) field emission SEM. For a more realistic beam size for a tungsten filament at 20 na, use a 250 nm diameter (=125 nm radius) beam d. Click Next --> to go to next setup box. 4. Distributions Dialog box. Generally leave this alone. Click Next --> to got to next setup box. 5. Options Dialog box. Here you may wish to increase the number of displayed trajectories (on screen), default is 200, but set to 2000. Leave rest alone. Click Next --> 6. Select Physics Model; here you can "peak under the hood" to see that there are many models for the various physical processes being modeled. Leave it alone. Click Finish. 7. You now get a New Simulation Request box. Click Yes. And away it goes. 8. Active display. At the bottom of the active window will be a timer showing elapsed time, and also a running calculation of the backscattered electron coefficient. There will be an actively updated display of incident electrons (blue) and backscattered electrons (red) up to the max number you specified in Options Dialog box above> It is nice to be able to reduce the scale to see the position; you can do this under View --> adjust scale, setting the x axis to 4000 or more nm (also the second button from right on toolbar), or with the auto adjust button. Wait for the simulation to finish. Questions: what is the BSE coefficient (as fraction/decimal)? Having scaled the display, eyeball the maximum dimensions of the inelastically scattered electrons (blue ones), not using any single outlier, but a value ~90% of the farthest electron (straight line). If the electron trajectories got to the edges, then rescale the display: ViewàAdjust ScaleàDouble the x and y values Electron range in Z nm Radial electron range in X (or Y) nm (Not Diameter) 9. On the left column is displayed a folder labeled with the accelerating voltage. Click +, and then underneath (inside) are subfolders labeled Distribution, X-Ray, and X-Ray Radial Distribution. You want to save this run now to some folder you create on your computer, as you may want to come back and reexamine the run later. What is electron range? While used much, the definition is not always easily found in general books on SEM and EPMA. One definition I found, in the orange X-ray Data Booklet, is The electron range is a measure of the straight-line penetration distance of electrons in a solid, where they cite Everhart and Hoff, J. Appl. Phys, 42, 5837 (1971). You will see that for many materials there is a difference between furthest in Z (depth) vs furthest in X or Y (radial distance) Page 2 11/19/15

Open each option up one by one. 10. Distribution -- of electrons (potentially all: backscattered, transmitted, secondary) 1. ZMax--maximum Z penetration of ALL electrons (low relevance here) 2. ZMax Backscattered--max Z penetration of Backscattered Electrons (low relevance) 3. Backscattered Energy--histogram of spread of BSE energies (low relevance) 4. Transmitted Energy - irrelevant in this geometry 5. Surface Radius of BE--key data, this is the BSE spatial resolution. Question is how to interprete the "edge" of the BSE signal. I suggest the cumulative 90% of the signal (as it tails off on the outer limits for a bit. What is the surface radius? um Diameter (2 x radius)? um 6. Energy of Surface Radius of BE--low relevance here 7. Energy by Position--very important for consideration of the maximum extent of the lowest energy electrons that can cause CL to occur in the specimen. The concentric shells show the remaining energy level, and there are faint grayish boxes that show the maximum extent. Questions: For electrons with a maximum (remaining) energy of 3.75 kev (the 25% line, in green), what is their maximum depth? nm maximum lateral radial spread from the center line? nm. Now consider the energy needed to produce Si Ka xrays which is kv. The red line is close to that level, what is the maximum depth at which there are electrons with this energy? nm Maximum lateral radial spread from the center line? 11. X-Ray -- these are the Phi Rho-Z 3 (PRZ) distributions (intensity of x-rays vs depth in nm), with Blue showing the x-rays generated that do not escape the sample (normally called Generated, but here called Non-absorbed ), and Red showing the x-rays that escape from the sample and reach the detector (normally called Detected or Emitted, but here called Absorbed apparently using nonuniform terminology, referring to x-rays absorbed by the detector very confusing!! Sorry.). Notice that the x-rays suffer absorption (IN THE SPECIMEN!) and only those near the surface escape untouched. Note that here and in virtually all samples, the maximum intensity (y axis) is at some short distance from the surface (recall depth is plotted to the right on X-axis). This is because maximum lateral scattering occurs below, not at, the surface. At what depth in Si does maximum lateral scattering occur? nm Questions: Click Si-K: At what approx. depth is the maximum depth (~99%) of Si K x-ray production? nm. Note that 2 numbers are given for Blue (Generated) and Red (Emitted). Calculate the percentage of Emitted relative to Generated (red divided by blue as percent). 12. X-Ray Radial Distribution-- here is the lateral (radial) expression of the x-rays generated at depth. Most of the x-rays are generated within some small radius of a projection directly below the point of impact on the surface, but there will be lateral scattering, and always be a "tail" extending far out. The program unfortunately does not display the x-ray radial data on a log scale, and thus it is hard to see the maximum radius within which the majority (e.g. 99%) of the x-rays are generated. To do this, you have to first display a particular display (e.g. Si k) and then manually export it to a file -- Distributionà Export Data 3 Refers to x-ray generation as a function of depth in the sample: Phi=generation; Rho=density; Z=depth. Page 3 11/19/15

II. Change the target to Au: Au Z=79 density= 19.5 Now, run Au in the same way as you did Si before. How does the electron range compare between Au and Si, for the same beam energy? Look at the X-ray phi-rho Z plot for Au La. : At what approx maximum depth (99%) of Au La x-ray production? nm. Calculate the percentage of Emitted relative to Generated (red divided by blue as percent). Look at the X-ray phi-rho Z plot for Au Ma. : At what approx maximum depth (99%) of Au Ma x-ray production? nm. Calculate the percentage of Emitted relative to Generated (red divided by blue as percent). Compare (1) maximum depth (~range) of Au La vs Au Ma x-ray production; (2) Emitted vs Generated percent for Au La vs Au Ma x-rays. Explain the behavior. III. Thin Film Simulations The instructions are pretty much the same as for the above case, the only difference being that in the first setup, Edit Layers, you click the Multi Layer rather than Grain Boundary button. Consider a half micron (500 nm) of Ni (density 8.9) on a SiO2 substrate (density 2.62). 1. Start at 20 kv. Do the electrons penetrate the substrate? Are x-rays being produced from both the top film and the substrate? Observe the different behavior of Ni K and L xrays. Using the phi-rho-z plots, fill in the blanks, using the values given in the upper right of each plot (Blue=Generated or non-absorbed; Red=Detected or absorbed ; % Detected = red/blue) Ni K generated Detected % Detected Ni L generated Detected % Detected Si K generated Detected % Detected O K generated Detected % Detected 2. Drop now to 8 kv. Do the electrons penetrate the substrate? Are x-rays being produced from both the top film and the substrate? Ni K generated Detected % Detected Ni L generated Detected % Detected Si K generated Detected % Detected O K generated Detected % Detected Page 4 11/19/15

Why are there no Ni K xrays at 8 kv? What patterns do you see here? Write/attach a short summary paragraph discussing what you have learned about electron scattering and x-ray production/x-ray emission, comparing/contrasting homogeneous versus non-homogeneous samples. Version history 9/11/2007 9/26/07 9/8/08 10/3/08 9/24/09 10/8/10 1/30/12 2/20/12 1/18/13 1/25/13 1/26/14 Page 5 11/19/15