The illumination source: the electron beam

Similar documents
MSE 321 Structural Characterization

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Basic structure of SEM

Scanning Electron Microscopy

Part II: Thin Film Characterization

M2 TP. Low-Energy Electron Diffraction (LEED)

Part I Basics and Methods

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Modern Optical Spectroscopy

AP5301/ Name the major parts of an optical microscope and state their functions.

Why microscopy?

Chapter 9. Electron mean free path Microscopy principles of SEM, TEM, LEEM

SEM Doctoral Course MS-636. April 11-13, 2016

Needle cathodes for high-brightness beams. Chase Boulware Jonathan Jarvis Heather Andrews Charlie Brau

Electron beam scanning

tip conducting surface

Chapter 2 Structure and Imaging of a Transmission Electron Microscope (TEM)

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

object objective lens eyepiece lens

h p λ = mν Back to de Broglie and the electron as a wave you will learn more about this Equation in CHEM* 2060

SEM Optics and Application to Current Research

STRONG DOUBLE LAYER STRUCTURE IN THERMIONIC VACUUM ARC PLASMA *

~1 V ~20-40 V. Electron collector PLASMA. Ion extraction optics. Ionization zone. Mass Resolving section Ion detector. e - ~20 V Filament Heater

Lecture 7: Electron Emission

Design and numerical simulation of thermionic electron gun

The Liquid Metal Ion Source A Hot Ion Source. Jon Orloff Professor Emeritus, University of Maryland and FEI Company Hillsboro, Oregon

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

Practical course in scanning electron microscopy

Photoelectric Effect Experiment

Auger Electron Spectroscopy (AES)

Everhart-Thornley detector

PhysicsAndMathsTutor.com 1

Invited Lecture. "Different Aspects of Electron Microscopy. Sardar Vallabhbhai National Institute of Technology, Surat. Deepak Rajput & S.K.

I live in this atom, with my other electron brothers

Electron Diffraction

Low kv Scanning Electron Microscopy

Chapter 2 Instrumentation for Analytical Electron Microscopy Lecture 5. Chapter 2 CHEM 793, 2011 Fall 1

Massachusetts Institute of Technology. Dr. Nilanjan Chatterjee

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Analytical Methods for Materials

SOLID STATE PHYSICS PHY F341. Dr. Manjuladevi.V Associate Professor Department of Physics BITS Pilani

ρ. Photoemission is presumed to occur if the photon energy is enough to raise qf πε, where q is the electron charge, F the electric field, and ε 0 φ ω

High-Resolution. Transmission. Electron Microscopy

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

Paper 2. Section B : Atomic World

CHARACTERIZATION of NANOMATERIALS KHP

SEM stands for Scanning Electron Microscopy. The earliest known work describing

Dual Nature of Radiation and Matter-I

Life cycle of a tungsten cold field emitter

Questions/Answers. Chapter 1

Recent Status of Polarized Electron Sources at Nagoya University

MSN551 LITHOGRAPHY II

QUANTUM PHYSICS. Limitation: This law holds well only for the short wavelength and not for the longer wavelength. Raleigh Jean s Law:

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Transmission Electron Microscopy

JURONG JUNIOR COLLEGE J2 H1 Physics (2011) 1 Light of wavelength 436 nm is used to illuminate the surface of a piece of clean sodium metal in vacuum.

DUAL NATURE OF RADIATION AND MATTER I K GOGIA KV JHARODA KALAN DELHI.

Homework 2: Forces on Charged Particles

Crystal Structure and Electron Diffraction

Project report. Spacecraft Charging and Mitigation Methods. By Muhammad Azam. Abstract

sin" =1.22 # D "l =1.22 f# D I: In introduction to molecular electron microscopy - Imaging macromolecular assemblies

The Franck-Hertz Experiment

A NEW LEED INSTRUMENT FOR QUANTITATIVE SPOT PROFILE ANALYSIS

MSE 321 Structural Characterization

Astronomy 203 practice final examination

MSE 321 Structural Characterization

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

TMT4320 Nanomaterials November 10 th, Thin films by physical/chemical methods (From chapter 24 and 25)

ADSORBATE EFFECTS ON FIELD EMISSION

Name the region of the electromagnetic radiation emitted by the laser. ...

The CeB6 Electron Gun for the Soft-X-ray FEL Project at SPring-8

AQA Physics A-level Section 12: Turning Points in Physics

Electron microscopy in molecular cell biology I

H2 Physics Set A Paper 3 H2 PHYSICS. Exam papers with worked solutions. (Selected from Top JC) SET A PAPER 3.

Laboratory 14: Ratio of Charge to Mass for the Electron

*Specifications subject to change without notice.

Sparks in Gases: Line Spectra

Chapter 9: Quantization of Light

Ecole Franco-Roumaine : Magnétisme des systèmes nanoscopiques et structures hybrides - Brasov, Modern Analytical Microscopic Tools

Principles of Electron Optics

MEMS Metrology. Prof. Tianhong Cui ME 8254

University of Puerto Rico at Humacao Department of Physics and Electronics

Stepwise Solution Important Instructions to examiners:

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

X-RAY SPECTRA. Theory:

Ion Implanter Cyclotron Apparatus System

THE CHARGE-TO-MASS RATIO OF THE ELECTRON

Ma5: Auger- and Electron Energy Loss Spectroscopy

Biochemistry 9001 Protein structure determination by 3D Electron Microscopy

V 11: Electron Diffraction

Quantum Mechanics (made fun and easy)

Praktikum zur. Materialanalytik

Field Emission and Channeling Radiation for High-Spectral-Brilliance X-ray Sources

Ratio of Charge to Mass (e/m) for the Electron

MODELING AND ELECTROSTATIC FOCUSING FOR A FIELD EMISSION ELECTRON SOURCE *

Revision Guide. Chapter 7 Quantum Behaviour

Modeling Electron Emission From Diamond-Amplified Cathodes

Questions on Electric Fields

Equivalent cylinder model for electron guns

Transcription:

The SEM Column

The illumination source: the electron beam The probe of the electron microscope is an electron beam with very high and stable energy (10-100 kev) in order to get images with high resolution. There are different electron beam sources which are different for the lifetime, for the beam intensity and so on. In principle, there are two methods for the electron extraction: Thermoionic electron emission A tungsten or lanthane esaborate (LaB 6 ) filament are heated by Joule effect. The increasing temperature of the filament gives energy to the electrons enough to overcome the working function of the material becoming free electrons. Field emission A very high electric field is applied to the cathode in order to extract the electron by tunneling effect. Some sources are covered by a low working function material such as zirconium oxide (which emits electrons by Schottky effect).

Thermoionic electron emission The tungsten filament The Richardson equation gives the current density emitted from a material for thermoionic effect: J c = AT 2 exp( E W / kt) A is a constant of the emitter material [A/cm 2 K 2 ] T is the absolute temperature emission [K] E W is the working function of the material [ev] (for the tungsten is 4.5 ev) K the Boltzmann constant [ev/k]

Thermoionic electron emission The tungsten filament At high temperature (higher than 2700 K) the electrons gain energy enough to overcome the tungsten E W producing a high electron current The tungsten filament has a diameter of 100 µm and it is usually folded with a V shape with a curvature ray of about 100 µm. The electron emission occurs from the tip of the filament (in a area of about 100 µm x 150 µm )

The electron gun by thermoionic electron emission The electron gun is characterized by three main parties: The filament. Wehnelt cylinder at negative bias with respect to the filament. The hole anode at positive bias of the high voltage of a power supply.

Wehnelt cylinder The filament electrons are emitted at a very large angle. The Wehnelt cylinder focuses the beam as well as controls the electrons emission from the filament.

Wehnelt cylinder The presence of an electrostatic field between the filament and the Wehnelt region focuses the beam as an electrostatic lens. The result is an image formation between the Wehnelt and the anode (crossover), with d 0 of diameter and α 0 of angular aperture (divergence).

A proper SEM operation requires a stable current probe on the sample which has to be time constant and the same in every point of the sample. In order to obtain a stable current, the filament current, i f, has to reach the saturation condition: it means that a small variation of i f doesn t induce a variation of the beam current, i b. At the saturation regime, the electrons are emitted only from the tungsten filament tip.

The anode The electrons emitted from the filament are then accelerated in the region between cathode (Wehnelt) and anode. An electron fraction deriving from the filament goes through the anode hole going to the electromagnetic lenses. Generally the electron current deriving from the anode,i b, is called beam current. During the path of the electrons inside the SEM column, a fraction of the electrons is stopped due to the lens aperture. For this reason the current arriving on the sample (i p probe current) is lower than the beam current.

The electron source of LaB 6 The LaB 6 (2.4 ev) has a working function lower than that one of W (4.5 ev), for this reason, with the same temperature, much more electrons are emitted from the source. Tip of LaB 6 mounted on the holder Magnified tip of LaB 6 Tip of LaB 6 ruined from the evaporation and from the oxide formation

The electron source of LaB 6 It is a single crystal of about 100 μm and it is about 0.5 mm lenght and it is heated by a graphite or renio support. These materials don t react chemically with the LaB 6 filament. The crystal tip is of about 1 μm in diameter. The very high electric field on the tip favours the electrons emission. The high sharp crystals have a higher brightness but a lower lifetime of the source. Blunt crystals have a lower brighteness but a longer lifetime. A LaB 6 source needs, with respect to a W filament, a high vacuum level of 10-4 Pa because the source could be easily affected by contaminations. For this reason after the air exposion, the temperature of the crystal should be increased slowly. In this way the degasing of crystal material is induced.

High electric fields induce the electrons emission. A field emission cathode is a tungsten needle (ray 100 nm) settled on a W hook. A negative bias voltage is applied on the cathode which is very intense on the tip. When the electric field arrives to a value of 10 V/nm, the electric field potential decreases and the electrons are able to go out by tunnelling effect. By these sources, it is possible to obtain a current density of 10 5 A/cm 2 (for a thermoinic source only 1-3 A/cm 2 ). Field emission guns (FEG)

Field emission guns (FEG) The current density, emitted from a field emission gun, depends strongly by the applied electric field F according to the Fowler-Nordheim equation: J = 6.2 10 6 E E E F W F + 1 2 E F W 2 exp( 6.8 10 9 E 9 W / F) [A/m 2 ] For F>5x10 9 V/m, the current density is of 10 5 A/cm 2 (for a thermoinic source only 1-3 A/cm 2 ) and the brightness is hundreds times higher with respect to a thermoinic source.

Sorgenti Field ad emissione guns di campo (FEG) (FEG) Usually in common SEMs, there are the following field emission gun emitters: Cold Field Emitters (CFE) Thermal Field Emitters (TFE) Schottky Field Emitters (SFE)

Cold Field Emitters (CFE) The emission derives from a few nanometers area and it is indipendent from the source temperature. Even if the total current is relatively small (1-10 μa), the brightness is particulary high (10 8 A/cm 2 sr @ 20 kv ) thanks to the very small beam dimensions. The beam is focused and accelerated by two anodes. The bias voltage between the first anode and the cathode (3-5 kv) determines the electric field to extract the electrons. The bias voltage between the second anode and the cathode (from some hundreds of Volts to 30 kv) accelerates the electrons. (ELECTRON GUN OF A CFE) Scheme of the Butler s triode

Cold Field Emitters (CFE) The proper operation of a CFE requires a very clean enviroment, for this reason a vacuum level of 10-8 -10-9 Pa is needed. Before working, the emitter is hitted for few seconds at very high temperature (2500K). This procedure damages slowly the emitter tip. Nevertheless, even if cleaning procedure is performed every day, the tip damage occurs at very long time. Advantages: the very small dimensions of the beam (3 nm) requires a very small focusing process (by the electromagnetic lenses) to reach the proper dimension of the spot (1 nm). low energetic spread. since the beam source is changed rarely, the system (source-lenses) remains allaigned and clean for long time, assuring reproducibility and stability in the measurements.

Thermal Field Emitters (TFE) TFE have the same properties of CFE, but they work at high temperatures. For this reason the tip is always clean reducing the noise and the instabilities even at not perfect vacuum conditions. Moreover, the tip becomes sharp, due to the high electric field, improving the performances.tfe are able to operate as CFE at low temperatures for short periods.

Schottky Field Emitters (SFE) The electric field on the tip of SFE is applied to decrease the material working function. For this reason such field emitters are coated with low working function materials such as ZrO 2. Even if SFE is a thermoinoic emitter, the brightness and the current density are comparable with that ones of CFE. The electron gun of a SFE is quite similar to that one of CFE. SFE guns include a suppressor grid to eliminate unwanted thermionic emission from regions outside the tip.

Schottky Field Emitters (SFE) The emission currents are of about 30-70 μa. Useful lifetime of a SFE is about 12 15 months, so it must be replaced on a regular basis. Vacuum level, required for successful Schottky operation, is not as demanding as that one of CFE, but in practice an ultrahigh vacuum aids long term stability, prevents poisoning of the ZrO 2 cathode, and maximizes brightness. The spot dimension of CFE and TFE are almost equal, whereas that one of SFE is bigger because bigger is the curvature ray. Nevertheless such thing could be an advantage when bigger spots are required. Finally, the energetic spread could be bigger because the cathode is hitted.

Parameters of the electron gun Brightness, β (A/cm 2 /steradiant) is defined as the beam current for unit area and solid angle. β current ip 4i p = = 2 2 2 2 area solid _ angle πd = π d p 2 pα p πα p 4 The brightness is constant and it is the same in all the column points. For this reason the brightness on the sample is almost the same of the brightness close to the source. The defects and the aberrations of the lenses decrease the effective value of the brightness.

Parameters of the electron gun The operation of a thermoinic electron gun was studied in a model system by Haine and Einstein (1952). The brightness is given by: β = Jc ev kt = AT exp( Ew / k kt ) The brightness is proportional to the accelerating voltage, while rapidly increases with the temperature of the filament, even though T also appears as a factor in the denominator.

Caratteristiche Parameters of del the cannone electron elettronico gun Lifetime: a W filament evaporates gradually on time due to the high temperature of the operation: the filament makes thin and stops working. Increasing the filament temperature (oversaturation), the evaporation rate increases and induces a fast break of the filament. Source dimensions: the beam dimension at the crossover, for a W source, is tipically ~ 50 μm (it depends on the gun configurations and the work conditions). Such relatively high dimensions need of an high electro-optical reduction of the images to obtain a small electron beam enough to obtain a good resolution. The new generation of electron microscopes has smaller beam dimension: for the LaB 6 source the dimension of the beam in the gun is of ~ 5 μm, while for the field emission sources is of 5-25 nm. Energetic Spread, E: this is the energetic dispersion of the electron emitted from the filamet. For the W is ~ 3 ev, for the LaB 6 is ~ 1.5 ev and for the field emission sources is ~ 0.3 1 ev. Stability: this indicates how much the electron emission is constant in the working time. The Schottky sources are the more stable; the termoionic sources have good stability too, in comparison with the field emission sources.

Comparison among the different electronic sources operating @20kV