arxiv:astro-ph/ v3 7 Apr 2005 Space Telescope Science Institute 2, 3700 San Martin Drive, Baltimore, MD 21218, U.S.A.

Similar documents
A Cross-Calibration between Tycho-2 Photometry and Hubble Space Telescope Spectrophotometry

A Recalibration of Optical Photometry Based on STIS Spectrophotometry

The HST Set of Absolute Standards for the 0.12 µm to 2.5 µm Spectral Range

TECHNICAL REPORT. Doc #: Date: Rev: JWST-STScI , SM-12 August 31, Authors: Karl Gordon, Ralph Bohlin. Phone:

WFC3/UVIS Photometric Transformations

Absolute Flux Calibration for STIS First-Order, Low-Resolution Modes

Study of the evolution of the ACS/WFC sensitivity loss

Improved Photometry for G750L

An Algorithm for Correcting CTE Loss in Spectrophotometry of Point Sources with the STIS CCD

The HST/STIS Next Generation Spectral Library

Impacts of focus on aspects of STIS UV Spectroscopy

New On-Orbit Sensitivity Calibration for All STIS Echelle Modes

Calibration of ACS Prism Slitless Spectroscopy Modes

Grism Sensitivities and Apparent Non-Linearity

Fringe Correction for STIS Near-IR Long-Slit Spectra using Contemporaneous Tungsten Flat Fields

NICMOS Photometric Calibration

Point-Source CCD Photometry with STIS: Correcting for CTE loss

NICMOS Status and Plans

Updated flux calibration and fringe modelling for the ACS/WFC G800L grism

Measurement of the stellar irradiance

Setting UBVRI Photometric Zero-Points Using Sloan Digital Sky Survey ugriz Magnitudes

COS FUV Dispersion Solution Verification at the New Lifetime Position

Revised Filter Profiles and Zero Points for Broadband Photometry

Delivery of a new ACS SBC throughput curve for Synphot

arxiv: v2 [astro-ph.im] 26 Jun 2018

XMM-Newton Optical-UV Monitor: introduction and calibration status OM instrument and calibration

arxiv: v1 [astro-ph] 19 Jun 2007

arxiv:astro-ph/ v1 26 Nov 2004

First On-orbit Measurements of the WFC3-IR Count-rate Non-Linearity

Here Be Dragons: Characterization of ACS/WFC Scattered Light Anomalies

Verification of COS/FUV Bright Object Aperture (BOA) Operations at Lifetime Position 3

arxiv: v2 [astro-ph.im] 5 Sep 2018

ACS CCDs UV and narrowband filters red leak check

Updates to the COS/NUV Dispersion Solution Zero-points

Photometric Systems. Neil Phillips 08 April Introduction 1. 2 Magnitudes and Colours 2

Determining the magnitudes and spectral types of the components of the binary Mira X Ophiuchi

A Calibration Method for Wide Field Multicolor. Photometric System 1

APLUS: A Data Reduction Pipeline for HST/ACS and WFC3 Images

Catalog Information and Recommendations

SMOV Absolute Flux Calibration of the COS FUV Modes

All-Sky Spectrally Matched UBVRI ZY and u 0 g 0 r 0 i 0 z 0 Magnitudes for Stars in the Tycho2 Catalog

SBC L-Flat Corrections and Time-Dependent Sensitivity

Wavelength Calibration Accuracy for the STIS CCD and MAMA Modes

The Effective Spectral Resolution of the WFC and HRC Grism

2 Properties of light, magnitudes, errors and error analysis

5.6 Spectrophotometry and Magnitudes

All-Sky spectrally matched UBVRI-ZY and u g r i z magnitudes for stars in the Tycho2 catalog

Earth Flats. 1. Introduction. Instrument Science Report ACS R. C. Bohlin, J. Mack, G. Hartig, & M. Sirianni October 25, 2005

EXPOSURE TIME ESTIMATION

Investigating the Efficiency of the Beijing Faint Object Spectrograph and Camera (BFOSC) of the Xinglong 2.16-m Reflector

CCD astrometry and UBV photometry of visual binaries

Lab 4 Radial Velocity Determination of Membership in Open Clusters

The in-orbit wavelength calibration of the WFC G800L grism

Time Dependence of ACS WFC CTE Corrections for Photometry and Future Predictions

GDR1 photometry. CU5/DPCI team

Performance of the NICMOS ETC Against Archived Data

Cross-Talk in the ACS WFC Detectors. I: Description of the Effect

Data analysis: CMD and SED

arxiv:astro-ph/ v1 12 Nov 2003

The HII Regions of Sextans A

Selection of stars to calibrate Gaia

Relative Astrometry Within ACS Visits

CHEMICAL ABUNDANCE ANALYSIS OF RC CANDIDATE STAR HD (46 LMi) : PRELIMINARY RESULTS

Photometric relationships between Gaia photometry and existing photometric systems

ESTIMATING DISTANCES FROM PARALLAXES. III. DISTANCES OF TWO MILLION STARS IN THE Gaia DR1 CATALOGUE

Improving the Absolute Astrometry of HST Data with GSC-II

FGS2r: Deadtime, Background, Photon Aging, Sensitivity Calibrations, and Noise Properties

Astrometric Performance of STIS CCD CTI Corrections on Omega Cen Images

BV R photometry of comparison stars in selected blazar fields

Lorentzian analysis of the accuracy of modern catalogues of stellar positions

A Fast Algorithm for Cosmic Rays Removal from Single Images

High accuracy imaging polarimetry with NICMOS

Extraction of Point Source Spectra from STIS Long Slit Data

Optical/NIR Spectroscopy A3130. John Wilson Univ of Virginia

THE ABSOLUTE DIMENSIONS OF THE OVERCONTACT BINARY FI BOOTIS

MARCS: MODEL STELLAR ATMOSPHERES AND THEIR APPLICATION TO THE PHOTOMETRIC CALIBRATION OF THE SPITZER SPACE TELESCOPE INFRARED SPECTROGRAPH (IRS)

arxiv: v2 [astro-ph.ep] 2 Nov 2017

The Accuracy of WFPC2 Photometric Zeropoints

The Galactic O-Star Spectral Survey (GOSSS) Project status and first results

SkyMapper and the Southern Sky Survey

arxiv:astro-ph/ v1 13 May 2004

Characterizing the COS OSM1 Drift in the Dispersion Direction

Estimating Visual Magnitudes for Wide Double Stars

Frequency analysis of five short periodic pulsators

Breathing, Position Drift, and PSF Variations on the UVIS Detector

Thirteen-Color Photometry of Open Cluster M48

Exploring the substellar IMF in the Taurus cloud

arxiv:astro-ph/ v2 2 May 2005

GALEX GR1 Instrument Performance and Calibration Review

Satellite Type Estination from Ground-based Photometric Observation

Flat Fields and Flux Calibrations for the COS FUV Channel at Lifetime Position 4

LSST, Euclid, and WFIRST

The x Factor: Determining the Strength of Activity in Low-Mass Dwarfs

arxiv:astro-ph/ v1 17 Oct 2002

High Signal-to-Noise, Differential NICMOS Spectrophotometry

SBC FLATS: PRISM P-FLATS and IMAGING L-FLATS

arxiv: v1 [astro-ph.sr] 5 Jun 2018

WFC3 Calibration Using Galactic Clusters

arxiv:astro-ph/ v1 5 Oct 2001

Transcription:

Accepted at Publications of the Astronomical Society of the Pacific (June 2005 issue) A cross-calibration between Tycho-2 photometry and HST spectrophotometry arxiv:astro-ph/0504085v3 7 Apr 2005 J. Maíz Apellániz 1 Space Telescope Science Institute 2, 3700 San Martin Drive, Baltimore, MD 21218, U.S.A. jmaiz@stsci.edu ABSTRACT I show that Tycho-2 photometry and HST spectrophotometry are accurate and stable enough to obtain a precise cross-calibration by analyzing a wellcalibrated sample of 256 stars observed with both Hipparcos and HST. Based on this analysis, I obtain the following photometric zero points in the Vega magnitude system for Tycho-2: 0.020±0.001 (B T V T ), 0.078±0.009 (B T ), and 0.058±0.009 (V T ). Subject headings: space vehicles: instruments stars: fundamental parameters techniques: photometric techniques: spectroscopic 1. Introduction It is nowadays extremely common to analyze photometric observations by comparing them with synthetic photometry derived from observed or theoretical spectral energy distributions (SEDs). Such comparisons are done by establishing a magnitude system based on a reference spectrum, be that of a real object, such as Vega, or a simple artificial spectrum, such as a constant in f λ or f ν (STScI 1998). Each reference spectrum yields a different magnitude system defined from the expression: 1 Affiliated with the Space Telescope Division of the EuropeanSpace Agency, ESTEC, Noordwijk, Netherlands. 2 The Space Telescope Science Institute is operated by the Association of Universities for Research in Astronomy, Inc. under NASA contract No. NAS5-26555.

2 ( ) P(λ)fλ (λ)λdλ m P = 2.5log 10 +ZP P, (1) P(λ)fλ,ref (λ)λdλ where P(λ) is the total-system sensitivity curve, f λ (λ) is the SED of the object, f λ,ref (λ) is the SED of the reference spectrum, and ZP P is the zero point for filter P. In order to attain accurate results when comparing measured magnitudes or colors with SED models, it is necessary not only to have an accurate knowledge of f λ,vega (λ) but also of P(λ) and of ZP P. For example, Bohlin & Gilliland (2004) measured the spectrum of Vega and found that in the Johnson system (which uses that star as a reference), ZP V = 0.026±0.008. One can also define a system where ZP P = 0 for any filter, such as the VEGAMAG 1, STMAG, or ABMAG systems (STScI 1998). The lack of an accurate knowledge of the system sensitivities has plagued some groundbased systems such as Johnson s UBV (Bessell et al. 1998), mostly due to the use of different observing conditions, technologies, and reduction techniques by different observers. Modern space-based telescopes tend to be more uniform and stable and usually produce better-quality photometry. ZP P is usually close to 0.0 but not exactly so, the reason being the common use of secondary calibrators (Vega is often too bright for a detector and/or unaccesible from many sites to be observed). ZP P thus needs to be measured (Bessell et al. 1998; Cohen et al. 2003; Bohlin & Gilliland 2004), since assuming it is exactly zero can introduce systematic errors in the comparison between observed magnitudes and reference SEDs. The Hipparcos mission (ESA 1997) observed the full sky and yielded the Tycho catalog, which is reasonably complete down to V = 11.5. The original Tycho catalog was consequently reprocessed by Høg et al. (2000b) to produce the Tycho-2 catalog, which contains 2.5 million stars and is currently the most complete and accurate all-sky photometric survey in the optical. The Tycho-2 catalog contains photometry in two optical bands, B T and V T, whose sensitivities were analyzed by Bessell (2000) and use Vega as the reference spectrum. The careful processing of Tycho-2 photometry was described by Høg et al. (2000a), including the difffferent tests used to check for possible systematic errors. HST spectrophotometry is calibrated using the method of Colina& Bohlin(1994), which is based on a combination of Landolt BV photometry, ground-based spectrophotometry, and SED models. Four white dwarf stars observed with the Space Telescope Imaging Spectrograph (STIS) are used as primary calibrators: G191B2B, GD71, GD153, and HZ43 (Bohlin et al. 1995). The absolute flux calibration has an accuracy of 4% in the FUV and 2% in 1 Note that it is possible to derive VEGAMAG magnitudes from SEDs using the Johnson throughputs but those values should be different from published photometry due to the different zero points used.

3 the optical (Bohlin 2000) but, given that the photometric repeatibility of STIS is 0.2-0.4% (Bohlin et al. 2001), the relative flux calibration for colors derived from STIS spectra is expected to be better than 2% in the optical. The latest values for the Advanced Camera for Surveys (ACS) photometric zero points are also based on that same calibration (De Marchi et al. 2004). Given the usefulness of the Tycho-2 photometric database for a number of astronomical studies and the accuracy of the absolute flux calibration of HST spectrophotometry, I considered it important to calibrate the first with respect to the second one, as well as to check the existence of possible problems in either of them. Ultimately, we want to obtain the zero points for Tycho-2 magnitudes, ZP BT and ZP VT, and color, ZP BT V T. 2. The data In order to test the consistency of the Tycho-2 and HST calibrations we would ideally need a large uniform sample of stars with B T and V T magnitudes that has also been observed in the optical with an HST spectrograph. Such a sample has indeed been obtained for the Next Generation Spectral Library (or NGSL, Gregg et al. 2004, see also http://lifshitz.ucdavis.edu/~mgregg/gregg/ngsl/ngsl.html). Originally, the NGSL intended to obtain low-resolution 1660-10200 Å spectra for 600 stars with a wide range of temperatures, gravities, and metallicities. Unfortunately, the failure of STIS in August 2004 ended the program before reaching that goal. However, 378 stars that are also included in the Tycho-2 catalog had already been observed, and that number is large enough for our purposes. Each star was observed using three different STIS gratings, G230LB, G430L, and G750L. Here, only the latter two will be used since those are the ones that span the Tycho-2 filters. The NGSL spectra were obtained using the 52 0.2 slit without a peak-up, which is not the ideal configuration for absolute spectrophotometric calibration, the reason being that the slit is narrow enough that if the star is not well centered, the aperture correction used may not be accurate. In principle, an off-center positioning could also cause problems with the relative spectrophotometric calibration if the aperture correction was strongly dependent on wavelength due to variations in the PSF 2. Fortunately, for G430L and G750L that is only a strong effect at the long-wavelength part of the spectrum beyond V T (STScI 2005). Therefore, the relative fluxes (and hence the derived colors) should not be affected as long as the star did not shift position significantly during the visit. Given that all exposures for 2 Also, due to diffraction off the slit edge.

4 a given star were obtained in a single orbit (usually not filling it completely) and that the typical drift rate for HST is less than 10 mas/hr (STScI 2005), indeed one would expect a shift of less than 10% of a STIS CCD pixel in the relative position of the star with respect to the slit between the first and the last exposure. There are also two calibration issues that need to be addressed regarding the fact that all exposures were obtained at the E1 position using a CCD subarray. The use of a subarray requires the definition of a background region closer to the star than for a measurement with a full array; I checked that this selection did not affect the measured fluxes. Also, the location of the E1 position, closer to the readout point in the detector, minimizes CTE effects but the CTE correction algorithm itself (Bohlin & Goudfrooij 2003) was not originally designed to work with CCD subarrays, so a test should be carried out to check for its validity. In order to explore the possible problems with the spectrophotometric accuracy mentioned in the previous paragraph, I first calculated the effect of the CTE correction on the derived spectrophotometric B T and V T magnitudes by extracting the spectra with and without the correction and comparing the results. The correction turned out to be very small, with anaverage of 0.010 magnitudes for V T, 0.018 magnitudes for B T, and 0.008 magnitudes for B T V T. As a further check, I measured the value of the discontinuity between the G430L and G750L gratings by calculating the ratio between the two fluxes in the 5550-5650 Å, region, where both gratings overlap in coverage. Results are shown in Fig. 1, both without applying the CTE correction and applying it. As it can be seen, in both cases the majority of the data points are clustered around a zero value for the jump, indicating the lack of a systematic effect. However, for the non-cte-correction case a small slope as a function of V T is present, which indicates that a non-negligible correction is indeed required. For the case with CTE correction, the data have no dependency with V T and have a distribution with mean of 0.12% and standard deviation of 1.83%. Given the results in the previous paragraph, I adopted the following criteria for selecting the NGSL sample: The CTE correction was applied. Only stars with a 5600 Å jump of less than 2.5% (in absolute value) were included. Given that the spectrophotometry and the photometry used in this article were obtained in different epochs, I eliminated variable stars. The criterion used was the presence of a variability flag in the Tycho photometry. With the restrictions above, our final NGSL sample was reduced to 256 objects.

5 InordertoprovideafurthercheckonthepossibleeffectsofsystematicapertureandCTE effects I used a control sample by analyzing the spectrophotometric standards of Bohlin et al. (2001) that have Tycho-2 photometry with magnitudes brighter than 12.0 and uncertainties of 0.06 magnitudes or less. Those stars were observed with STIS using the 52 2 slit and with the full CCD array, so the problems mentioned above (slit centering and validity of the CTE correction algorithm) should not be relevant. Four of the Bohlin et al. (2001) stars satisfy the above requirements for both B T and V T (BD +17 4708, BD +28, 4211, BD +75 325, HD 93521) and an additional three do so only for B T (AGK + 81 266, Feige 34, HZ 44). The stars in both samples were analyzed using a synthetic photometry code created for Maíz-Apellániz (2004) and their spectrophotometric B T and V T magnitudes calculated. 3. Results I start by analyzing the relative flux calibration of our data. I show in Fig. 2 the difference between the photometric(from the Tycho-2 catalog) and spectrophotometric(computed from STIS spectra) values for the B T V T of each of the stars in our samples as a function of the photometric B T V T. No general trend is observed as a function of color and the data are symmetrically distributed around a central value, which I take to be ZP BT V T. I measured ZP BT V T by calculating the weighted mean using 1/σ 2 B T V T as weights and found it to be 0.020±0.001 magnitudes. I show the histogram for the B T V T data in Fig. 3, both in absolute and relative (corrected for ZP BT V T and dividing each point by its photometric uncertainty) terms. The second histogram has a median of 1.2 10 5 and a standard deviation of 1.04 and the distribution is very well approximated by a normalized Gaussian. All of the above implies that an accurate cross-calibration of colors vs. relative fluxes between Tycho-2 photometry and HST spectrophotometry is possible in principle without having to invoke e.g. modifications in the Tycho filter sensitivities or the STIS calibration. Furthermore, given that the normalized histogram has a standard deviation only slightly larger than 1.0, the largest source of deviations from the expected value originates in the photometry, not in the spectrophotometry. Since the mean photometric σ BT V T = 0.025 magnitudes, the accuracy of the spectrophotometrically-derived Tycho-2 colors must be better than 1%, which agrees with the published value for the STIS photometric repeatibility Bohlin et al. (2001). Only four objects in the Bohlin sample have both B T and V T photometry. Of course, such a low number is not enough to do accurate statistics but we can see in Fig. 2 that the results from that sample are consistent with the derived ZP BT V T and with the absence of a

6 color dependence for the cross-calibration. One can argue that the two stars with B T V T around 0.3 (BD +75 325 and HD 93521) are slightly above the ZP BT V T line and, hence, may indicate the beginning of a small departure from the general rule for very blue objects. However, it can also be a fluctuation caused by small-number statistics, which is reinforced by the reversal of the trend in the bluest of the stars in the Bohlin sample, BD +28 4211. In any case, even if the effect turned out to be real, it would be very small and affect only extremely blue stars. Next, I deal with the absolute calibration of our data. I show in Fig. 4 the difference between the photometric and spectrophotometric values for both B T (left panel) and V T (right panel). Once again, no significant trend is observable as a function of B T or V T, thus enabling the cross-calibration of the two systems. However, a difference is readily apparent between the relative and absolute plots for the NGSL sample: for the absolute case the data are also concentrated around a central point but a tail towards the negative in the distributions of B T,phot B T,spec and V T,phot V T,spec is clearly present. Such a behavior is the expected one if some of the stars are not well centered on the 52 0.2 slit, as previously mentioned. Under such circumstances it is not possible to derive a value for either ZP BT or ZP VT with a precision of the order of 0.01 magnitudes or better. Therefore, for that task I decided to use instead the Bohlin sample, which was obtained using the wider 52 2 slit. Given the high precision achieved for ZP BT V T, it is a better strategy to measure just one of the two absolute ZP values and then use the color zero point to obtain the other one. Considering that I have more stars with B T data thanwith V T data (seven vs. four), I choose the first one for the absolute flux calibration. A weighted mean for those seven stars in the Bohlin sample yields ZP BT = 0.078±0.009 magnitudes. Applying ZP BT V T, we then obtain ZP VT = 0.058±0.009 magnitudes. As it can be seen in Fig. 4, those values are compatible with the observed distributions in B T,phot B T,spec and V T,phot V T,spec for the NGSL sample if one discards the negative-values tail. I have obtained a precise cross-calibration between Tycho-2 photometry and HST spectrophotometry which, combined with the independent absolute flux calibrations of both instruments, should allow for accurate comparisons between Tycho-2 photometry and synthetic photometry generated from SED models. Furthermore, the use of the zero points presented here should also allow combinations of Tycho-2 photometry with that of other surveys with precise zero points, such as 2MASS (Cohen et al. 2003). I would like to thank Rodolfo Barbá for fruitful conversations on this topic and Ralph Bohlin, Santiago Arribas, and an anonymous referee for useful comments on the manuscript.

7 REFERENCES Bessell, M. S. 2000, PASP, 112, 961 Bessell, M. S., Castelli, F., & Plez, B. 1998, A&A, 333, 231 Bohlin, R. C. 2000, AJ, 120, 437 Bohlin, R. C., Colina, L., & Finley, D. S. 1995, AJ, 110, 1316 Bohlin, R. C., Dickinson, M. E., & Calzetti, D. 2001, AJ, 122, 2118 Bohlin, R. C., & Gilliland, R. L. 2004, AJ, 127, 3508 Bohlin, R. C., & Goudfrooij, P. 2003, STIS Instrument Science Report 2001-003 (STScI: Baltimore) Cohen, M., Wheaton, W. A., & Megeath, S. T. 2003, AJ, 126, 1090 Colina, L., & Bohlin, R. C. 1994, AJ, 108, 1931 De Marchi, G., Sirianni, M., Gilliland, R., Bohlin, R., Pavlovsky, C., Jee, M. Mack, J., van der Marel, R., & Boffi, F. 2004, ACS Instrument Science Report 2004-008(STScI: Baltimore) ESA. 1997, The Hipparcos and Tycho Catalogues (ESA SP-1200) Gregg, M. D., Silva, D., Rayner, J., Valdes, F., Worthey, G., Pickles, A., Rose, J. A., Vacca, W., & Carney, B. 2004, American Astronomical Society Meeting Abstracts, 205 Høg, E., Fabricius, C., Makarov, V. V., Bastian, U., Schwekendiek, P., Wicenec, A., Urban, S., Corbin, T., & Wycoff, G. 2000a, A&A, 357, 367 Høg, E., Fabricius, C., Makarov, V. V., Urban, S., Corbin, T., Wycoff, G., Bastian, U., Schwekendiek, P., & Wicenec, A. 2000b, A&A, 355, L27 Maíz-Apellániz, J. 2004, PASP, 116, 859 STScI. 1998, Synphot User s Guide, Howard Bushouse and Bernie Simon (eds.). 2005, STIS Instrument Handbook, J. Maíz Apellániz and J. Kim (eds.) This preprint was prepared with the AAS L A TEX macros v5.2.

8 10.0 NGSL sample, no CTE correction NGSL sample, CTE correction 10.0 7.5 7.5 5.0 5.0 5600 Angstrom jump (%) 2.5 0.0 2.5 2.5 0.0 2.5 5600 Angstrom jump (%) 5.0 5.0 7.5 7.5 10.0 2.5 5.0 7.5 10.0 12.5 10.0 2.5 5.0 7.5 10.0 12.5 V T,phot V T,phot Fig. 1. The 5600 Å flux discontinuity as a function of V T (photometric) without (left) and with (right) CTE correction for the 378 stars in the NGSL sample. A single object is located off the scale shown. The dashed lines indicate the limits considering for defining the sample used to derive ZP BT V T

9 0.20 NGSL sample Bohlin sample 0.15 (B T,phot V T,phot ) (B T,spec V T,spec ) 0.10 0.05 0.00 0.05 0.10 0.5 0.0 0.5 1.0 1.5 2.0 B T,phot V T,phot Fig. 2. Comparison between photometric and spectrophotometric B T V T colors as a function of photometric B T V T for the two samples. The error bars represent the photometric uncertainties and the horizontal line marks the proposed ZP BT V T.

10 60 60 50 50 40 40 30 30 20 20 10 10 0 0.15 0.10 0.05 0.00 0.05 0.10 0.15 (B T,phot V T,phot ) (B T,spec V T,spec ) 4 3 2 1 0 1 2 3 4 [(B T,phot V T,phot ) (B T,spec V T,spec ) 0.020]/σ BT V T 0 Fig. 3. Histograms for the comparison between photometric and spectrophotometric B T V T colors for the NGSL sample. (left) Regular histogram. (right) Histogram for the data shifted by the proposed ZP BT V T and normalized by the individual uncertainties. A Gaussian distribution with µ = 0 and σ = 1 is overplotted for comparison.

11 0.2 0.2 0.1 0.1 0.0 0.0 B T,phot B T,spec 0.1 0.2 0.3 0.1 0.2 0.3 V T,phot V T,spec 0.4 NGSL sample Bohlin sample NGSL sample Bohlin sample 0.4 0.5 0.5 0.6 3 4 5 6 7 8 9 10 11 12 2 3 4 5 6 7 8 9 10 11 0.6 B T,phot V T,phot Fig. 4. Comparison between photometric and spectrophotometric B T (left) and V T (right) magnitudes as a function of the photometric values for the two samples. The error bars represent the photometric uncertainties and the horizontal line marks the proposed ZP BT (left) and ZP VT (right). The asymmetric scatter of values below the line is due to light loss at the slit due to poor centering (see text for details).