Preliminary comparison between GEANT4, Fluka and the TileCal 2002 Test Beam data

Similar documents
Overview of validations at LHC

Measurement of the associated production of direct photons and jets with the Atlas experiment at LHC. Michele Cascella

CALICE scintillator HCAL

Study of TileCal Sampling Fraction for Improvement of Monte-Carlo Data Reconstruction

Validation of Geant4 Physics Models Using Collision Data from the LHC

Combined Calorimeters Properties Part 1.

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

Exclusive Central π+π- Production in Proton Antiproton Collisions at the CDF

Jet Reconstruction and Energy Scale Determination in ATLAS

CALICE Test Beam Data and Hadronic Shower Models

Recent CMS results in the forward region with the CASTOR detector. Sebastian Baur for the CMS Collaboration

Simulation and validation of the ATLAS Tile Calorimeter response

ATLAS Tile Calorimeter Calibration and Monitoring Systems

Jet energy measurement in the ATLAS detector

Contents. What Are We Looking For? Predicted D

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

Granularity of ATLAS Tile Calorimeter studied through simulations

PAMELA satellite: fragmentation in the instrument

arxiv:hep-ex/ v1 7 Oct 1999

Simulation study of scintillatorbased

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

Status of the physics validation studies using Geant4 in ATLAS

Les Premières Données dans ATLAS et le Calorimètre à Argon Liquide

Geant3/Geant4 Comparisons - status

Detector Simulation. Mihaly Novak CERN PH/SFT

Jet reconstruction with first data in ATLAS

Commissioning of the ATLAS LAr Calorimeter

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

Tracker material study with the energy flow through the CMS electromagnetic calorimeter. Riccardo Paramatti, Ambra Provenza

ATLAS NOTE. August 25, Electron Identification Studies for the Level 1 Trigger Upgrade. Abstract

Dual readout with tiles for calorimetry.

Jet Energy Calibration. Beate Heinemann University of Liverpool

Test setup, APDs,, preamps Calibration procedure Gain monitoring with LED Beam test results Future R&D options

Studies of the ATLAS hadronic Calorimeter response to muons at Test Beams

Dario Barberis Evaluation of GEANT4 Electromagnetic and Hadronic Physics in ATLAS

ATLAS Tile Calorimeter performance for single particles in beam tests

HARP (Hadron Production) Experiment at CERN

Precise Measurement of the Absolute Yield of Fluorescence Photons in Atmospheric Gases

Available online at Physics Procedia 37 (2012 )

Geant4 Physics Lists: Status and Proposed Upgrades. Dennis Wright (SLAC) 25 February 2011

5 Hadronic calorimetry

NuSOnG Detector Resolution, Calibration, and Event Separation

Hadron Calorimetry at the LHC

Di muons and the detection of J/psi, Upsilon and Z 0 Jets and the phenomenon of jet quenching

First Run-2 results from ALICE

V0 cross-section measurement at LHCb. RIVET analysis module for Z boson decay to di-electron

Calorimetry in particle physics experiments

CMS Simulation Software

Transition Radiation Detector for GlueX

Measurement of the η mass by the NA48 Experiment

The reaction p(e,e'p)π 0 to calibrate the Forward and the Large Angle Electromagnetic Shower Calorimeters

GEANT4 simulation of the testbeam set-up for the ALFA detector

Calorimeter test-beam results with APDs

Absolute D Hadronic Branching Fractions at CLEO-c

ATLAS NOTE October 12, 2009

Justin Vandenbroucke (KIPAC, Stanford / SLAC) for the Fermi LAT collaboration

Physics sources of noise in ring imaging Cherenkov detectors

Deep generative models for fast shower simulation in ATLAS

Tracking properties of the ATLAS Transition Radiation Tracker (TRT)

The ERC ENUBET project high precision neutrino flux measurements in conventional neutrino beams

ATLAS: Status and First Results

Alignment of the ATLAS Inner Detector

Results from HARP. Malcolm Ellis On behalf of the HARP collaboration DPF Meeting Riverside, August 2004

Muon reconstruction performance in ATLAS at Run-2

Jet reconstruction in W + jets events at the LHC

Extending the Calibration of the ATLAS Hadronic Calorimeter to High P t Chris Sears, University of Chicago May 16 th, 2002 Advisor: James Pilcher

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Dario Barberis Evaluation of GEANT4 electromagnetic physics in ATLAS

NA62: Ultra-Rare Kaon Decays

Alignment of the ATLAS Inner Detector. Oscar Estrada Pastor (IFIC-CSIC)

Simulation Results for CLAS12 From gemc

The ENUBET neutrino beam

Jet Calibration Issues in t t Events

Atlas results on diffraction

Electromagnetic and hadronic showers development. G. Gaudio, M. Livan The Art of Calorimetry Lecture II

MDI and detector modeling

CLEO c. Anders Ryd Cornell University June 7, e e cc D D. D K,D K e

Hadronic energy reconstruction in the combined electromagnetic and hadronic calorimeter system of the CALICE Collaboration

Cavern background measurement with the ATLAS RPC system

V 0 production studies at LHCb. Mathias Knecht, EPFL , joint SPS-ÖPG-ÖGA 2 meeting, Innsbrück, Österreich, September 2-4, 2009

SOFT QCD AT ATLAS AND CMS

Jet quenching in PbPb collisions in CMS

Studies of Hadron Calorimeter

Conference Report Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

SUPPLEMENTARY INFORMATION

Jet Results in pp and Pb-Pb Collisions at ALICE

Physics with Tau Lepton Final States in ATLAS. Felix Friedrich on behalf of the ATLAS Collaboration

Measurements of the total and inelastic pp cross section with the ATLAS detector at 8 and 13 TeV

Recent Developments in Geant4. Calice Collaboration Meeting 10 March 2010 Dennis Wright (on behalf of the Geant4 hadronic working group)

OPERATIONS & PERFORMANCE OF THE ATLAS DETECTOR IN LHC RUN II

Variation in MC prediction of MB nu flux

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Particle detection 1

Luminosity measurement and K-short production with first LHCb data. Sophie Redford University of Oxford for the LHCb collaboration

Preliminary analysis of p-pb data update n. 6

Dual-Readout Calorimetry Simulations

Calorimeter energy calibration using the energy conservation law

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

Usage of GEANT 4 versions: 6, 7 & 8 in BABAR

Transcription:

Preliminary comparison between GEANT4, Fluka and the TileCal 2002 Test Beam data M. Cascella, T. Del Prete, A. Dotti, M. Gallas, W. Pokorski, A. Ribon, I. Vivarelli LCG - Physics Validation Meeting July 25, 2007

Introduction integration of Fluka in the test beam Monte Carlo machinery Some details on the analysis Total energy distribution 20 GeV 50 GeV Shower shape (at 20 GeV) lateral end longitudinal shape longitudinal shape correlations 2

The 2002 test beam 4 TileCal modules stacked together projective particle beam electrons, pions, muons and protons wide range of energies 2-350 GeV 3

Goal and Motivation Be able to compare simulations results from Geant4 and FLUKA with data in the context of the ATLAS Tile 2002 test beam. To come up with a reusable machinery which is as much as possible application-independent: - In order to reduce implementation effort (and number of possible bugs) the maximum number of elements should be common to both G4 and FLUKA applications: common source of geometry same format of the simulation output allowing common digitization/analysis Main principles: Use GDML+FluGG+FLUKA to create FLUKA-hits with the material & geometry extracted from the G4 simulation of the TB. Re-use as much as possible the work done for the Geant4 and data comparison: re-create the same ntuples, use the same macros for the analysis. 4

Fluka Geant4 Geometry Interface FluGG (FluGG) developed by P.Sala and S.Vanini allows running FLUKA with Geant4 geometry - FORTRAN - C++ interface allowing to 'plug' Geant4 geometry into FLUKA all the steering still done through FLUKA input cards all the output as in native FLUKA - configurable through input cards, based on FLUKA 'user routines' very useful tool, but a few things need to be added for the purpose of G4 - FLUKA validation: Geometry is not always available in form of G4Classes (=> GDML) Mimic of the G4 sensitive detectors HitsManager Root I/O hit persistency Hits Manager Root IO G4 geometry GDML FluGG FLUKA Fluka output OO Hits Input card 5

Geant4 simulations and FLUKA hit analysis G4 simulations: The geometry in use by the old Tile 2002 TB was ported (V. Tsulaia) to the ATHENA framework (ATLAS framework for event processing). A G4Atlas application was assembled: the easiest way to use the latest G4 versions and (if needed) access to the digitization and reconstruction in use by the ATLAS exp. Geometry exportation: Once the geometry is loaded into the Atlas G4 application it can be exported in xml format using the GDML writers.fluka+flugg can read the GDML geometry using the GDML readers Any mismatch in between the geometries used by G4 and FLUKA will be detected at the time the FLUKA hits are processed. The read-out geometry (complex) implemented in the G4 SD is not exported. The FLUKA-hits (pre/post step, PDG, energy, time) are read into the G4Atlas application and processed using the G4SD. The process of FLUKA or G4 produces always the same TileHitVector container ---> we can use the same digitization, reconstruction and analysis Analysis: Can be done at the step level, hit level or after digit+reconstruction To reproduce the Tile2002 analysis a specific G4UserAction was created. It produces paw tuple information at the level of the energy-hit. More information can be found in W. Pokorski and M. Gallas presentations at LCG Physics Validation Meeting 25 Jnauary 2006: 6 http://indico.cern.ch/conferencedisplay.py?confid=a06408

Monte Carlo Data One position of the Tile calorimeter at eta=0.35 The coordinate system has (0,0,0) at the center of the central barrel module 1, below we have the module0 and on top two extended barrels. Particle gun: PDGs: +11, -211, +211, 2212, +13 beam spot flat at -3000 mm (z and y in [-16,9,16,9] mm) beam smearing in theta and phi constant energies: 20-350 Gev. Geant4 Two versions: - geant4-07-patch-01 (25 Oct 2005) - geant4-08-01-patch-01 (27 Jul 2006) Two physics lists: QGSP, QGSP_BERT ATLAS standard cuts of 1mm. Birks law implemented in the G4 sensitive detector. Time cut in the hit collection 200ns FLUKA One version: 7 - FLUKA-2006.3 Configuration card: CALORIMEter Cuts suggested by Paola Sala (100kev for e+and 5 kev for gammas) Birks law (quenching) implemented in FLUKA. Time cut in the hit collection 200ns

Calibration Energy measured summing over 3 half-modules (-0.7<η<0) residual pedestal (small) subtracted from data data and MonteCarlo are both calibrated at nominal beam energy (20 GeV electrons) 8

Corrections electronic noise is measured on data and a correspondent gaussian noise is added to the simulations to account for the effect of photostatics we also add a poissonian fluctuation to the MC (70.7 photoelectrons per GeV). 9

Corrections: S-shape scintillator spacer (Fe) master (Fe) the total energy depends (~5%) on the impact point due to the periodic TileCal structure. Electron data and simulations are both corrected (pions do not suffer from this effect since their shower is larger) 10

particle selection 20 GeV (π - run) Cherenkov counter to separate e/pi (4.9% residual electron contamintation in pions) anti-proton contamination is negligible muon are easily removed (calorimetric cut) 50 GeV (π + run) preliminary results Cherenkov used to identify protons we use two variables related to the shower shape (C long and C tot ) to separate e/pi 11

20 GeV electrons 12

MC Calib: 36.80 MC Calib: 34.03 MC Calib: 33.07 - Data - MC simulation mean values at 20 GeV are fixed by the calibration 13

20 GeV electrons 7% statistical errors only No residual pion contamination in electron run considered GEANT 4.8 has the better agreement with our data 14

20 GeV pions 15

20 GeV pions: total energy 16

residual electron contamination we can study the residual contamination of electrons in pion beams using combination of calorimetric (C long and C tot ) and Cherenkov cuts Residual electrons in pion runs using C long and C tot : 2.7% using Cherenkov gives: 4.9% At 20 GeV beam polarity is negative (very few anti-protons expected) 17

Effect of the electron contamination We study the effect of contamination on mean and sigma of the pion energy distribution adding the expected fraction of electrons to the correspondent pion sample G4.7 electrons pions 18 10k pi + 1k e- Example: effect of a 10% electron contamination

Electron contamination Expected Residual Contamination Mean (GeV) +0.7% GEANT 4.7 Sigma (GeV) +4.7% No contamination 19

Comparison with the data Mean (GeV) Sigma (GeV) 8% <1% data g47 g48 g47bert g48bert fluka 12% 6% data g47 g48 g47bert g48bert fluka Before and after adding the electron contamination20 Mean value is increased, we get a better MC/data agreement Sigma becomes larger, resulting in better or comparable agreement for GEANT+Bertini and Fluka

50 GeV pions (preliminary results) 21

experimental issues Cherenkov used to reject protons -> variables related to the shower shape are used to separate pions from positrons mean value affected at 1% level 5% uncertainty over the width positron residual contamination (~2.7%) Caveat: the cut is not applied to MC (would induce a bias dependent on the how well the shape is reproduced, need a more detailed study) 22 Preliminary evaluations

50 GeV pions (preliminary results) 23

50 GeV pions mean and sigma 3 % 20% 2% NB: cuts applied to data only. no contaminations included yet in MC 3% 24 the mean values for G4 +Bertini and Fluka are in agreement with our data within 2% (preliminary results)

preliminary studies on the proton contaminations Mean (GeV) Sigma (GeV) if the residual proton contamination is <5% the effect can be safely neglected at this level of analysis Etot p e π Cher cherenkov pedestal well separated from signal. Proton residual (after Cher cuts) contamination neglected 25

preliminary studies on the positrons contaminations Mean (GeV) GEANT 4.7 Sigma (GeV) In addition the effect of the calorimetric cut still needs to be understood in detail 26

The shower shape (E = 20 GeV) 27

Longitudinal and lateral segmentation TILECAL s longitudinal segments S1 ~ A cells ~ 1.7 λ I S2 ~ BC cells ~ 4.8 λ I S3 ~ D cells ~ 2.2 λ I the core is defined as the projective tower crossed by the beam line ~25x25x150 cm 3 the halo is the external volume 28

experimental issues Electron contamination has been included in MC simulations (4.9%) To get rid of residual muons and out-of-axis events an energy release of at least 5 GeV is requested in the central tower 29

Longitudinal shower shape 30

Energy in Sample 1 31

Energy in Sample 2 32

Energy in Sample 3 33

The longitudinal shower shape (20 GeV pion) 9.5% 3% S1 data G4.7 G4.8 G4.7b G4.8b fluka All simulations give more energy in the first sample 16% S2 data G4.7 G4.8 G4.7b G4.8b fluka S3 the tendency is reversed in Sample 2 and 3 Fluka and G4+Bertini give reasonable agreement at this level of the analysis 68% data G4.7 G4.8 G4.7b G4.8b fluka 34 Fluka is the closest to data

Lateral shower shape 35

Energy release in the core 36

Energy release in the halo 37

The lateral shower shape (20 GeV pion) core (mean) 2% data G4.7 G4.8 G4.7b G4.8b fluka halo (mean) 2.6% GEANT with the Bertini list and Fluka are closer to the data GEANT without Bertini has significantly less energy in the shower halo data G4.7 G4.8 G4.7b G4.8b fluka

Conclusions 39

Conclusions GEANT4 QGSP has a lower energy response and the resulting shower shape is shorter and narrower than the data GEANT4 needs Bertini to reproduce the characteristics of hadronic shower Overall acceptable agreement between data GEANT+Bertini and Fluka For 50 GeV need to take into account correct beam residual contaminations and effect of calorimetric cuts to improve comparison Big improvement on both simulation accuracy and on understanding of the data with respect to previous studies 40

Open issues and work in progress better control of contaminations and calorimetric cuts to extend the analysis on the total energy distributions at E beam = 100, 180, 350 GeV expand our work on the shower shapes to higher energies. 41

Backup slide 42

electron cuts c_tot pi e c_long we use two variables related to the shower shape (C long and C tot ) to get rid of the residual electrons 43