Series VVX// The models VX// have been revised. For details, please refer to catalog no. ES0-A. Similar updating Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.) Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 00-0-Main Office: () -00-Outside Local Area: (00) -00-www.stevenengineering.com JIS Symbol Port P Port R Solenoid Specifications Apparent Power Temperature Power source Frequency power (VA) consumption rise (Hz) (W) ( C ) Inrush Holding (Holding) (Rated voltage) 0 0 0. VX (Full wave rectification) 0/. 0. VX (Full wave rectification) 0/ 0.. 0. 0 VX (Full wave rectification) 0/.. Note) They are values in an ambient temperatue of 0 C ± C and application of rated voltage. coil for air (-X) comes with full wave rectifier. Changing coils from to and vice versa is impossible, because of different core shapes. Return voltage is 0% or more of the rated value at power and % or more at the power. Allowable voltage fluctuation is ± 0% of the rated voltage. Operating Fluid and Ambient Temperature Temp. Power conditions source Maximun Minimum, Operating fluid temperature ( C ) Water (Std.) 0 Oil (Std.) 0 Ambient temp. ( C ) High temp. Oil Steam water (X, E, N, P) (. N) (S,Q) 0 0 0 Ambient Temp. Power Operating fluid temp. ( C ) temperature conditions source Air Vacuum ( C ) Maximum / Minimum / 0 0 0 0 0 Tightness of Valve (Leak rate) Fluid Seal material NBR, FKM, EPM Normally closed (N.C.) Air cm /min or less Normally open (N.O.) Non-leak Liquid () Vacuum 0. cm /min 0 Pa m /s or less () or less Note ) iffers depending on the operating conditions such as pressure, etc. Note ) Value on option V, R, Y (Nonleak, Vacuum). Manifold Specifications Manifold Manifold type Number of valves (with gasket, screws) /Valve Specifications (Fluids: Oil) Max. operating pressure differential (MPa) N.O, N.C. C.O. (mmø),. VX -00.0 VX -00 0. 0.. VX-00 VX-00.0 VX -00 0. 0. VX-00 0. VX-00 VX-00 0. VX-00 0. Response Characteristics B Mount Common supply, Common exhaust, Individual out to 0 stations VVX VX0-00 VVX/ VX0-00 Manifold Base and Applicable Solenoid Valve Part No. n: stations Manifold base A port Applicable solenoid valve Base weight (g) VVX-stations Rc / VX -00- VVX-stations Rc / n x 00 + 0 VVX-stations Rc / VVX-stations Rc / VX -00- n x + VVX-stations Rc / VVX-stations Rc / VX -00- n x + /Valve Specifications (Fluids: Air, Vacuum, Inert gas) (mmø) Max. operating pressure differential (MPa) C.O. /.. VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 VX-00 0..0 0. 0. VX-00 0. VX-00 0. Flow characteristics Air C [dm /(s bar)] b Cv 0. 0. 0.0 0 0. 0. 0.. Switching Signal Power source VX Pressure VX VX Note) The value is the case of no grease applied on armature.. Flow characteristics Oil Av x 0 (m ) Cv converted. 0.0.... 0.0 0.0 0. 0.0 0. 0. 0. 0. 0. 0.0 0. 0. Max. system pressure (MPa).0 Max. system pressure (MPa).0 Weight (g) 0 0 0 0 0 0 0 0 0 Weight (g) 0 0 0 0 0 0 0 0 0 Response time (msec) ON OFF or less 0 or less 0 or less 0 or less 0 or less 0 or less 0 or less 0 or less or less or less 0 or less 0 or less --
Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 00-0-Main Office: () -00-Outside Local Area: (00) -00-www.stevenengineering.com [For liquid and gas ( voltage)] * Refer to the table () given below for availability. [For gas ( voltage)] Table () Orifice Size Solenoid valve model VX VX VX (. mm ) (No.) (. mm ) ( mm ) VX VX VX ( mm ) Ð Ð Ð Table Electrical () Rated Voltage- Electrical Entry-Electrical Option Insulation type Electrical option (00 V) (00 V) (0 V) (0 V) (0 V) ( V) ( V) ( V) irect Operated Port Solenoid Valve/Manifold For Air, Gas, Vacuum and Oil. mm. mm mm mm Solenoid valve option Nil Standard Valve/Body Class B Class H G C, T G, C T S Note) S L, Z S L, Z Ð Ð Ð Ð Ð Ð Ð Ð Ð Ð Ð Ð Note) Surge voltage suppressor is attached in the middle of lead wire. How to Order Solenoid Valves for Manifold Common/For manifold Normally closed (N.C.) and Normally open (N.O.) are available only for VX with power supply. Normally open (N.O.) is available. Mark Valve N.C. Valve N.O. * Select an option mark in page -- by ÒApplicable Fluids Check ListÓ for special fluids outside of the standard.. mm. mm mm mm VX VX VX * Refer to the table () given below for availability. Valve/Body Common/For Manifold Solenoid valve option Nil Standard * Select an option mark in page -- by ÒApplicable Fluids Check ListÓ for special fluids outside of the standard. Manifold base Symbol Applicable valve VVX VX -00 VVX VVX VX -00 VX -00 00 Connection 00 (No connection screw) For manifold Write both the base part number and the solenoid valve to be mounted or blanking plate part number. (Example) stations of VX common SUP, individual port Rc /. (Base P/N) VVX-0 pc. (Solenoid valve P/N) VX-00-G pcs. ( P/N) VX0-00 pc. How to Order Manifold Base VVX VVX VVX How to Order Manifold G C T Series VVX// Conduit IN terminal Conduit terminal * Refer to the table () given below for availability. Rated voltage 00 V 0/ Hz 00 V 0/ Hz 0 V 0/ Hz 0 V 0/ Hz V V 0 V 0/ Hz V 0/ Hz Other (Please contact SMC separately) * Refer to the table () given below for availability. 00 X G IN Terminal Rated voltage 00 V 0/ Hz 00 V 0/ Hz 0 V 0/ Hz 0 V 0/ Hz 0 V 0/ Hz V 0/ Hz Connection 00 (No connection screw) Nil S L Z Number of stations 0 stations 0 0 stations Port size (Individual port) Rc / Rc / The models VX// have been revised. For details, please refer to catalog no. ES0-A. Similar updating for other VX* series are scheduled to follow shortly. Electrical option * All common ports are Rc /.The common SUP is indicated as ÒPÓ on the common port and the individual SUP is indicated as ÒRÓ. Arrangement of solenoid None With surge voltage suppressor With indicator light With light/surge voltage suppressor * Refer to the table () given below for availability. Plug The standard arrangements of manifolds should be placed on an individual port on this side, each solenoid valve from the left side and a blank plate in the right side. The right side of the common port provides plug. VC VW VQ VX VX VX VXA VN LVC LVA LVH LV LVQ LQ LVN TI/ TIL PA PAX PB --
Series VVX// The models VX// have been revised. For details, please refer to catalog no. ES0-A. Similar updating Construction/Principal Parts Material Port R Port P Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 00-0-Main Office: () -00-Outside Local Area: (00) -00-www.stevenengineering.com No. escription Material Standard Option q w e r Manifold body Retainer Manifold base Coil assembly Class B molded Brass Brass Class H molded t Armature Stainless steel y Core assembly Stainless steel, Copper Stainless steel, Silver u Gasket NBR FKM/EPM i Polyacetal, NBR Stainless steel Valve assembly FKM/EPM o Return spring Stainless steel!0 O-ring NBR FKM/EPM! Support spring Stainless steel --0
imensions irect Operated Port Solenoid Valve/Manifold For Air, Gas, Vacuum and Oil Series VVX// The models VX// have been revised. For details, please refer to catalog no. ES0-A. Similar updating IN terminal Conduit terminal Conduit VC VW VQ Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 00-0-Main Office: () -00-Outside Local Area: (00) -00-www.stevenengineering.com VVX VVX VVX (Mounting hole) Mounting hole A 0 B 0 C 0 0 Pitch F H J 0 0 0 K Indication of valve type L VVX VVX VVX M. 0. 0. n-rc, Symbol N 0. L L L L Stations Q 0 S 0 T 00 U Type indication (Gasket) 0 V 0 0 0 W 0 00 0 X 0 Y 0 Z VX VX VX VXA VN LVC LVA LVH LV LVQ LQ LVN TI/ TIL PA PAX PB --