Screening of Pesticides QuEChERS, LC-MS and Beyond

Similar documents
Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Multi-residue analysis of pesticides by GC-HRMS

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Highly Sensitive and Rugged GC/MS/MS Tool

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Validation Report 18

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

IMPROVING PESTICIDE RESIDUE DETECTION PROTOCOL FOR FRUIT

WADA Technical Document TD2003IDCR

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Choosing the metabolomics platform

Powerful Scan Modes of QTRAP System Technology

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Advanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Liquid Chromatography Mass Spectrometry. Shimadzu Corporation, UK; 2 Phytocontrol, France; 3 Shimadzu France, France. Trimesium S + CH 3 ETU

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Trading Rules in Targeted/Unknown Multiresidue Pesticides Analysis Using UHPLC-Orbitrap MS and Data Mining Technologies

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

Workflow Using Hyphenated Mass Spectrometry Techniques

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

MassHunter TOF/QTOF Users Meeting

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

LC-HRMS: Challenges for Routine Implementation

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Making Sense of Differences in LCMS Data: Integrated Tools

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

How to screen and identify unexpected and unwanted compounds in food

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Untargeted Screening on the X500R QTOF

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Analysis and Quantification of Mycotoxins in Cereals Using MRM HR on the SCIEX X500R QTOF System with SCIEX OS

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

Die Nadel im Heuhaufen

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

LC-MS Based Metabolomics

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Finnigan LCQ Advantage MAX

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Validation Report 8 Determination of pesticide residues in rice and wheat by GC-MS/MS and LC-MS/MS (QuEChERS method) Appendix 2

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Computer-assisted analysis of complex natural product extracts

Application Note. Edgar Naegele. Abstract

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

De Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

The new Water Screening PCDL

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Determination of urea in ultrapure water by IC-MS/MS

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Quantitative Screening of 46 Illicit Drugs in Urine using Exactive Ultrahigh Resolution and Accurate Mass system

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Transcription:

Pushing the Limits of Target Analysis and Non-target Screening of Pesticides QuEChERS, LC-MS and Beyond Paul Yang 1, Jon W. Wong 2, James S. Chang 3, and Jennifer Sutton 3 1. Ontario Ministry of the Environment, Etobicoke, Ontario, Canada 2. FDA-CFSAN, College Park, Maryland, USA 3. Thermo Fisher Scientific, San Jose, CA, USA 16 th CVG Annual Meeting, October 5, 2010

Outline Targeted analysis and non-targeted screening Limits of using liquid chromatography and mass spectrometry detector (LC-MS) for targeted analysis and non-targeted screening QuEChERS (Quick, Effective, Cheap, Easy, Rugged & Safe) Method performance of targeted analysis using high resolution mass spectrometry (HRMS) detector Using SIEVE as a tool for non-targeted screening Future work 2

Targeted and Non-targeted Pesticides Analysis Pesticides Known Knowns Known Unknowns Unknown Unknowns Targeted analysis (routine and non-routine analysis) Non-targeted screening 3

What Are Identification Points? (ID Points) Derived dfrom European Commission i Council Directive 96/23/EC, http://ec.europa.eu/food/food/chemicalsafety/residues/council_directive_96_23ec.pdfeuropa eu/food/food/chemicalsafety/residues/council directive pdf Detailed examples given for its applications in LC-MS analysis ( Identification of residues by LC-MS. The application of new EU guidelines, A.A.M. A Stolker, R.W. Stephany and L.A. van Ginkel, ANALUSIS, 2000, 28, #10, p.947) http://www.edpsciences.org/articles/analusis/pdf/2000/10/stolker.pdf?access=ok) 4

Identification Points (ID points) Legal compounds require 3 ID points while illegal compound require 4 ID points to be qualified as true-positively identified MS technique ID Points earned per ion Low resolution mass spectrometry (LRMS) 1 LRMS n Precursor ion 1 LRMS n Transition products (tandem MS) 1.5 High resolution mass spectrometry (HRMS) 2 HRMS n Precursor ion 2 HRMS n Transition products (tandem MS) 2.5 5

Identification of Pesticides Using Liquid Chromatography- Tandem Mass Spectrometry (LC-MS/MS) More than 1,000 pesticides used worldwide, along with their metabolites and degradation products, might be present in food and the environment LC-MS/MS is well established for target multi-pesticide screening with ihh the highest hih selectivity ii and sensitivity, iii and wide linearity range for quantitative results. Two LC-MS/MS multiple reaction monitoring (MRM) transitions can deliver four ID points and has been considered as an effective and rugged analytical approach to detect low level pesticides 6

LC-MS and LC-MS/MS in Non-targeted Screening The Limits it from the Outset t Require analytical standard to carry out non-targeted screening An (educated) trial and error process that requires multiple LC-MS or MS/MS runs Will require the use of library spectra or HRMS data to confirm the identity Difficult to obtain quantitative data Analysis of unknown practically not possible The limits has been a moving target since the late 1990s and changes with every new technology! 7

Limits in the Late 1990s LC/MS Analysis For example: Hewlett-Packard 1100 single quadrupole LC/MS system Inferior ID points provided d for the analysis Single ion monitoring is vulnerable to interference Limited horse power for multiresidue analysis 8

LC/MS Analysis Glyphosate and Glufosinate Glufosinate Glufosinate AMPA AMPA Glyphosate Glyphosate 13 13 C C 15 N Glyphosate Glyphosate HP 1100 LC-MS system C18 column, from 95:5 to 25:75 A: 5mM CH 3 COONH 4 in H 2 O; B: CH 3 CN Electrospray ionization (ESI) Negative, single ion monitoring of target and qualifier ions for glyphosate (390, 168), glufosinate (402, 180), AMPA (332, 110) and 13 C 15 N-glyphosate (392, 170) Identification Point of 2 AMPA: aminomethylphosphonic h h i acid L. Grey, B. Nguyen, and P. Yang, J. AOAC, 84, #6, 1770 (2001). 9

Limits in the Early 2000s (circa 2000~2003) For example: HP 1100-Sciex API 2000 LC-MS/MS system Does require a standard to create a method Gave the opportunity to explore mega methods! Can provide an ID point of three using two Multiple or selected reaction monitoring i (MRM or SRM) transitions MRM/SRM provided good selectivity Limited horse power for multiresidue analysis and may not provide enough data points to define chromatographic peaks correctly (< 100 analytes) 10

LC-MS/MS Analysis of Phenyl Ureas, Carbamates and Organophosphates Reconstructed MRM chromatograms of 39 target analytes in a 10-min LC-MS/MS analysis Area Co ounts, Ar rbitrary 12 Phenyl ureas 12 Carbamates 15 Organophosphates p Time (Minutes) Chunyan Hao, Bick Nguyen, Xiaoming Zhao, Ernie Chen, and Paul Yang, J. of AOAC, 93(2) 400-410, 2010. 11

Limits in the mid-2000s (circa 2004~2007) Hybrid LC-Tandem MS/Linear Iontrap (LC-qqqLIT) Analysis For example: HP 1100-Sciex API 4000q LC-MS/MS system Does require a standard to create a method Can provide an ID point of three using two multiple or selected reaction monitoring (MRM or SRM) transitions Allows for the collection of spectral library and library search (more ID points but inferior duty cycle time) MRM/SRM provided good selectivity and superb sensitivity Improved horse power for multiresidue analysis to provide enough data points to define chromatographic peaks for about 250 analytes 12

Typical MRM/SRM Chromatograms 57 Target Pharmaceutical and Personal Care Products 13

QuEChERS Sample Preparation Step 1: Weigh 5-gram of homogenized sample; add 5.0-mL of CH 3 CN 14

QuEChERS Sample Preparation Step 2: Add method surrogates, MgSO 4 and NaCl; shake and centrifuge CH 3 CN Extract Plant Matrix Aqueous 15

QuEChERS Sample Cleanup Dispersive Solid Phase Extraction ti Step 3: Add primary-secondary amine and MgSO 4 to extract 16

LC-MS/MS Chromatogram and Time Program (200 pesticides and Scheduled MRM ~400 transitions) XIC of +MRM (436 pairs): 238.1/163.0 amu Expected RT: 5.7 ID: 3-Hydroxycarbofuran.1 from Sample 13 (5.0 ppb-1) of Data20091211 blue b... Max. 1.4e4 cps. Flow rate 0.45 ml/min 2.6e5 Injection volume 20 μl 2.5e5 95% B A: 5 mm NH 4 HCO 2 in 2.4e5 2.3e5 0.1% HCOOH/H 2 O 2.2e5 2.1e5 B: 5 mm NH 4 HCO 2 in 2.0e5 0.1% HCOOH/MeOH OH 1.9e5 1.8e5 1.7e5 1.6e5 1.5e5 14e5 1.4e5 LC time 1.3e5 1.2e5 program 1.1e5 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 Time, min Column: RESTEK Ultra Aqueous C18 (100 mm x 21 2.1mm x 30 3.0 μm) ) 1.0e5 MS source temp: 500 o C 9.0e4 80e4 8.0e4 Mode: ESI positive 7.0e4 6.0e4 Spray voltage: 5000 volts 5.0e4 Curtain gas: 30 PSI 4.0e4 3.0e4 Collision gas: medium 2.0e4 1.0e4 5.7 5% B Gas 1: 50 PSI 0.0 Gas 2: 50 PSI 17

Using Information Dependent Acquisition-Enhanced Product Ion (IDA-EPI) Spectrum to Collect Library Spectra Threshold value Data/Information triggered EPI Scan MRM Scan Courtesy of fthermofisher h 18

IDA-EPI Data Processing 19

Typical Library Search Result 20

Limits in Known Unknown Analysis Using LC-qqqLIT MS Is time consuming and must have a standard to start with Requires the use of many injections to identify unknowns in a sample May run out of sample before the identification Faster LC, like fast gas chromatography (GC), will produce narrower peakwidths Still needs at least 10 data points to define a chromatographic peak for quantitation Increasingly difficult for the mass spectrometer t hardware to handle the overhead required for MRM, EPI spectrum and correctly define peaks Retention times shift Available analytical standards to carry out the analysis, especially standard mixes in mega-method, becomes the biggest challenge 21

Two Viable Alternatives? LC using a quadrupole tof-ms (qtof) or Orbitrap MS as a Detector Scanning speed tof-ms can scan 20 spectra/sec @ < 30,000 resolution, practical for most routine LC experiments Orbitrap MS can scan 2 spectra/sec @ 50,000 resolution, practical for a 2.1 mm LC column Accurate mass measurement will give one more level of confirmation of results, better data quality Product ion scan followed by full spectral library search will provide unambiguous identification of a suspicious component 22

Reconstructed LC/qTOF-MS Total Ion Chromatogram 23 qtof: quadrupole time-of-flight flight

LC/qTOF-MS Analysis of 39 Pesticides 32 of the 39 targets confirmed with mass accuracy within ±10 ppm 24

Un-identifiable Ions Root Cause Analysis van der Heeft E, Bolck YJ, Beumer B, Nijrolder AW, Stolker AA, Nielen MW. J Am Soc Mass Spectrom. (2009) 20(3):451-63. 25

Exactive Benchtop LC-MS An Orbitrap MS Based LC-MS Mass Resolution (R) 10,000 to 100,000, variable Mass accuracy Sub ppm Sensitivity 500 fg Buspirone with S/N >10:1 Dynamic range >10,000 000 within a spectrum Scan speed Up to 10 scans per second Mass range m/z 50-4000 Polarity switching One positive and one negative scan < 1 second (25K Resolution) 26

Can Orbitrap MS Provides a Viable Solution for Non-targeted t dknown Unknown Screening? Validation of Method Parameters 181 pesticides mixtures @ concentrations of 25, 100 and 250 ppb (mg/kg) were prepared in three matrices (oranges, spinach and apples) Target analytes introduced using ultra high pressure liquid chromatography (UHPLC) Replicates (4) analysis at mass resolution (R) of 10,000 (10k), 25k, 50k and 100k 27

Recovery Studies of Spinach, Oranges and Apples 25 µg/kg % Recovery 140 120 100 80 60 40 20 0 0 50 100 150 Spinach Orange Apple 100 µg/kg % Recov very 140 120 100 80 60 40 20 0 0 50 100 150 Spinach Orange Apple 250 µg/kg % Recover ry 140 120 100 80 60 40 20 0 0 50 100 150 Pesticide ID Number Spinach Orange Apple 28

Relative Standard Deviations (RSD %) of Spinach, Orange and Apple (N = 7) 25 µg/kg 100 µg/kg 250 µg/kg % RSD % RSD % RSD 40 35 30 25 20 15 10 5 0 0 50 100 150 40 35 30 25 20 15 10 5 0 40 35 30 25 20 15 10 5 0 0 50 100 150 0 50 100 150 Pesticide ID Number Spinach Orange Apple Spinach Orange Apple Spinach Orange Apple 29

Method Detection Limits, n = 7 @ 99% confidence (Spinach, Orange, Peach, Apple) 25 MDL (ng/g) 20 15 10 5 Spinach Orange Peach Apple 0 0 50 100 150 Pesticide ID Number Federal Register, U.S. Code of Federal Regulations, Part 136, Appendix B, 49 FR 43430, Oct 26, 1984; 50 FR 694, 696, Jan 4, 1985, as amended at 51 FR 23703, June 30, 1986. 30

Resolving a Pesticide Mixture of Similar Masses Molecular Isobars Pymetrozine C 10 H 11 N 5 O 218.10419 Pyracarbolid C 13 H 15 NO 2 218.1181111811 Ethoxyquin C 14 H 19 NO 218.15449 R = 10,000 Pymetrozine Pyracarbolid Ethoxyquin Estimated R (R est ) required for baseline separation 62,388 23,868 R = 25,000 R = 50,000 000 R = 100,000 31

Resolving [M + H] + of Isazophos (314.04941) and Triazophos (314.07141) (R est ~53,690) Isazophos Ti Triazophos R s = 10,000 000 R s = 25,000 R s = 50,000 R s = 100,000 000 Isazophos C 9 H 17 ClN 3 O 3 PS 313.041680 Triazophos C 12 H 16 N 3 O 3 PS 313.065002 32

Aldicarb sulfone C 7 H 14 N 2 O 4 S, MW = 222.067430 Accurate Mass EIC 1ppb in Spinach R= 10,000 R= 10,000 R= 25,000 R= 25,000 R= 50,000 R= 50,000 R= 100,000 R= 100,000 Stick Plot Point to Point Plot Stick Plot Point to Point Plot 33

Bitertanol C 20 H 23 N 3 O 2, MW = 337.179027 1ppb in Spinach 1ppb Standard Matrix interference! R= 10,000 R= 25,000 R= 50,000 R= 100,000 Stick Plot Point to Point Plot Stick Plot Point to Point Plot 34

Clofentezine C 14 H 8 C l2 N 4, MW = 302.012602 1ppb in Spinach 1ppb Standard R= 10,000 R= 25,000 R= 50,000 R= 100,000 Stick Plot Point to Point Plot Stick Plot Point to Point Plot 35

10 ng/g Mass Ac ccuracy (ppm ) 10 8 6 4 2 0 Mass Accuracy of Pesticides in Different Matrices at 10 and 100 ng/g Short Term Mass Axis Stability: ± 0.989575 ppm, N=2,495, 10 days -2 0 50 100 150 200 250 300 350 400 450 500-4 -6-8 -10 100 ng/g Pesticide ID Number Hazelnut Raisin Wheat flour Orange Spinach Mass Acc curacy (ppm) 10 8 6 4 2 0 Short Term Mass Axis Stability: ± 1.099298 ppm, N=2,670, 10 days -2 0 100 200 300 400 500-4 -6-8 -10 Pesticide ID Number Hazelnut Raisin Wheat flour Orange Spinach 36

The Limits? The method can be good for targeted and non-targeted analysis if we know what we are looking for (known unknown) Ionization source of Orbitrap has good universality The pro: any organic acids/bases will be fragmented and appear as a chromatographic peak in the extracted ion chromatogram The con: One too many peaks to examine and data interpretation has become the barrier How can we do an unknown unknown analysis? 37

What is SIEVE? SIEVE TM, XCMS TM, Masstrix TM, MZMINE TM, MetID TM, to name a few, are post data processing software developed by various vendors for metabolomic studies 38

Unalign vs Align Unaligned Aligned 39

Frame Selection (Time window with Accurate Mass) 40

Frame Report, Standard @ RT4.205 m/z 226.08924 Mthi Methiocarb Monoiotopic+H 226.08963 Aligned Chromatogram 41

Gernerate Formula from Monoisotopic Mass 0.549 ppm Mass Accuracy 10 ppb Right click on mass Then select Generate formula form mass 100 ppb 1000 ppb 42 42

Multilevel Methiocarb Spikes in Spinach Matrix 10, 100, 1000 ppb 43

Methiocarb Spiked Spinach Frames and dchemspider Search Report Matrix Blank 44

Principle Component Analysis (PCA): Spinach Methiocarb Outlier identified by PCA 45

Methiocarb ChemSpider Search Report: Corn 46

PCA Analysis: Corn Methiocarb Matrix Blank 47

ChemSpider Search: Orange Matrix Blank 48

PCA Analysis: Orange 49

Known Unknown Analysis (Test #1) Incurred sample Navel 50

Incurred Orange Sample Navel Imaverol 51

Incurred Orange Sample Navel, PCA Incurred Sample Matrix Blank 52

Isotope Ratio Actual vs. Simulation Mass Accuracy 0.454 ppm Imaverol Actual 53 Simulation 53

Known Unknown Analysis (Test #2) Incurred samples, Clementine Incurred clementine samples Pesticide (ng/g) Carbendazim 1.0±0.2 Imazili 365±57 Thiabendazole 64±6 54

Matrix Blank vs. Navel vs. Clementine 55

Workflow of Unknown Unknown Analysis True outlier: Outlier in the training i set Unknown: Outlier not in the training set Outlier identified by PCA 56

Conclusions and Future Work Initial studies showed that Orbitrap and Sieve can do target and non-target identification automatically at a concentration at above 100 ppb and a mass resolution of 50,000 000 or greater Pending on data exchange ability, parallel studies with new generation LC-tof- MS Development of a good/extensive training set: A library (training set) of LC-Orbitrap MS runs of identical parameter (user contributed or in house) Replicate sample analysis to achieve over-determination for the training set Explore the ability of Orbitrap and Sieve in unknown identification Mathematically, principal component(s) identified by frame, confirmed by PCA bt but not tin the training ii set can be extracted td Characterization of the high score outliers shall result in the identification of unknowns 57

Acknowledgements Ginseng Board of Wisconsin U.S. Environmental Protection Agency National Pesticide Standard Repository US U.S. Food and ddrug Administration i i Field laboratories National Institutes of Health Office of Dietary Supplements IAG Y1-OD OD-6004-0101 58

Teşekkürler Thank You! Dziekuje 谢谢 감사합니다 Köszonom For Your Attention! 59