Test Report. Report No.RLSZE Page 1 of 11

Similar documents
Test Report MITSUI HIGH-TEC (SHANGHAI) CO.,LTD NO.2001 XINJIN QIAO ROAD EXPORT PROCESSING ZONE PUDONG SHANGHAI CHINA

Test Report. Report No. ECL01I Page 1 of 7

Test Report. Report No. SCL03H Page 1 of 7

Test Report. Report No. RLSHD Page 1 of 6

Test Report. Report No. ECL01H Page 1 of 9

Test Report. ECL01H Page 1 of 9. Report No.

Test Report. Report No. ECL01H Page 1 of 9

Test Report. Report No. RLSHE Page 2 of 5 Test Result: Content 1 2

Test Report NANTONG HUADA MICROELECTRONICS GROUP CO., LTD NO.99 ZILANG ROAD,NANTONG CITY,JIANGSU PROVINCE

Test Report. Report No. ECL01H Page 1 of 7

Test Report. Report No. RLSHE Page 2 of 7

Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 2 of 11 Test Result(s) PART NAME NO.1 : BLACK PLASTIC TUBE Cadmium (Cd) Lead (Pb) Mercury (Hg

Test Report. Report No. ECL01H Page 1 of 7

Test Report No. : CE/2009/34977 Date : 2009/03/25 Page : 1 of 10

Test Report No. CANEC Date: 01 Sep 2011 Page 1 of 8

Test Report. LEDELS LIGHTING CO., LTD Address. Applicant

Test Report JIANGMEN ABQ ELEECTRONIC MATERIAL CO.,LTD NO.136 GAOXINWESTRD JIANGMEN HI-TECH INDUSTRIAL DEVELOPMENTZONE CITY GUANGDONG

Test Report No. SH / CHEM Date: Apr. 28, 2008 Page 1 of 6

Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report KUO SEN ENTERPRISE CO.,LTD NO.87-2 NINGPAO WEST ST. TAIPEI, TAIWAN, R.O.C

Test Report No. SH /CHEM Date: Oct. 22, 2009 Page 1 of 5

Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7

Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 2 of 9 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUND Test Item (s): Unit Metho

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI

Test Report. Report No. ECL01H Page 1 of 5

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 2 of 9 Test Result(s) PART NAME NO.1 : SILVER NIPPON COPPER WIRE Cadmium (Cd) mg/kg With refe

No. KE/2016/52417 Date 2016/05/26 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

No. CE/2012/44922 Date 2012/05/03 Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalen

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06

Test Report TAIYO INK(SUZHOU)CO.,LTD. NO.26 TAISHAN ROAD,SUZHOU NEW DISTRICT, SUZHOU CITY,JIANGSU PROVINCE,P.R.CHINA

TEST REPORT : SR A-DC, SR A-DA, SR A-DT, SR A-DN, SR C-DC, SR C-DA, SR C-DT, SR C-DN

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro

Thin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by

Test Report TAIYO INK(SUZHOU)CO.,LTD. NO.26 TAISHAN ROAD,SUZHOU NEW DISTRICT, SUZHOU CITY,JIANGSU PROVINCE,P.R.CHINA

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

No. CE/2012/C1503 Date 2012/12/18 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

The following sample(s) was/were submitted and identified by/on behalf of the client as : (2) (3) (4) (5) Please refer to next page(s).

No. : CE/2012/A3090 Date : 2012/10/23 GAP PAD 1000SF RICK STEWART REPORT PER REQUEST FOR QUOTE, DATED 10/5/11

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr

Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 2 of 6 Test results by chemical method (Unit: mg/kg) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test

Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 2 of 6 Test Result(s) PART NAME No.1 PART NAME No.2 PART NAME No.3 Cadmium (Cd) Lead (Pb) Mercu

No. CE/2014/51910 Date 2014/05/20 Page 2 of 5 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Test Report No. : CE/2015/15894 Date : 2015/02/04 NIHON ALMIT CO., LTD. ALMIT BLDG., , YAYOICHO, NAKANO-KU, TOKYO, JAPAN Page : 1 of 7 *CE/2015/

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

TEST REPORT. : The following submitted sample(s) said to be:-

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium

Management number No. KA/2015/80033 Date 2015/08/10 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an

Page : 2 of 12 Test Result(s) PART NAME No.1 : MIXED ALL PARTS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

TEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K

TEST REPORT Report No. : GR:HL: DATE : 20/11/2014

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material

Test Report No. CTSSA/13164/14 Date: 11/07/2014 Page: 1 of 10 CTS Ref. CTSSA/14/2009/Redring

Test Report No: (1) R1 Date: 29-Apr-13 Page 1 of 5

TEST REPORT Report No. : GR:HL: DATE : 27/10/2014

TEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. : CE/2011/A5289 Date : 2011/11/02 Page : 2 of 18 Test Result(s) PART NAME No.1 : BLACK GRAINS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Test Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item

TEST REPORT NUMBER: SHAH TESTS CONDUCTED. (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE:

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H

Test Report No. F690101/LF-CTSAYAA

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He

Test Report No. CTSSA/ /12 Date : 10/01/2012 Page: 1 of 5 CTS Ref. CTSSA/12/0018/Straits

Page 2 of 11 Test Result(s) PART NAME No.1 COPPER/SILVER COLORED METAL SHEET (INCLUDING THE PLATING LAYER) Cadmium (Cd) Test Item(s) Unit Method With

Page 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf

Test Report No. CRSSA/ /17 Date : 22/02/2017 Page: 1 of 9 CRS Ref. CRSSA/17/0450/EQX

CHI NHANH CONG TY TNHH SAN XUAT THUONG MAI HA PHONG -XUONG SAN XUAT

Test Report No Date : 27/NOV/2017 Page 1 of 5

ICP Test Report Certification Packet

Technical Report No A Dated

Test Report No. CRSSA/03608/18 Date : 28/03/2018 Page: 1 of 7 CRS Ref. CRSSA/18/0736/Toray

Page 2 of 11 Test Result(s) PART NAME No.1 YELLOW/WHITE PAD (EXCLUDING THE RELEASE FILM) Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With referenc

Test Report No. CTSSA/27121/12 Date : 04/01/2013 Page: 1 of 5 CTS Ref. CTSSA/12/4387/Luvata

Test Report No. CRSSA/25672/16 Date : 08/12/2016 Page: 1 of 9 CRS Ref. CRSSA/16/2799/Ametek

ICP Test Report Certification Packet

Test Report No. CRSSA/01754/18 Date : 19/02/2018 Page: 1 of 11 CRS Ref. CRSSA/18/0368/Ametek

Test Report No. CRSSA/08508/17 Date : 12/07/2017 Page: 1 of 9 CRS Ref. CRSSA/17/1742/CSC

Transcription:

Report No. Page 1 of 11 Applicant Address HER MEI ELECTRONIC CO.,LTD NO.61,FONG TIEN RD.,FONG TIEN INDUSTRY PARK,DAH-PYI SHANE,YUNLIN COUNTY,TAIWAN,R.O.C The following sample(s) and sample information was/were submitted and identified by/on the behalf of the client No. Sample Name Material Part No. (1) 正箔 LE LT LR LZ LL ZL LS (2) 負箔 LH HS HK HG SN HT (3) 電解紙 SP LB BL HR SU SS SH (4) 铝质电解电容器端子線 NP NK BP LA HC EC (5) 電解液 HL ML HA HX LV TC (6) 迫緊 LU HH EL UA SL (7) 鋁殼 Sample Received Date Jul. 21, 2012 Testing Period Jul. 21, 2012 to Jul. 25, 2012 Test Requested Please refer to the following page(s). Test Method Please refer to the following page(s). Test Result(s) Please refer to the following page(s). Tested by Reviewed by Approved by Date Jul. 25, 2012 Danny Liu Technical Manager Centre Testing International (Shenzhen) Co., Ltd. No. 15501266 Hongwei Industrial Zone, Bao an 70 District, Shenzhen, Guangdong, China

Report No. Page 2 of 11 Test Requested As specified by client, to test Lead(Pb), Cadmium(Cd), Mercury(Hg), Hexavalent Chromium(Cr(VI)), Polybrominated Biphenyls(PBBs), Polybrominated Diphenyl Ethers(PBDEs), Fluorine(F), Chlorine(Cl), Bromine(Br), Iodine(I), Polycyclic Aromatic Hydrocarbons(PAHs), Perfluorooctane Sulfonates(PFOS), Perfluorooctanoic Acid(PFOA) in the submitted sample(s). Test Method Test Method Measured Equipment(s) MDL IEC 62321:2008 Ed.1 Sec.8 Lead (Pb) IEC 62321:2008 Ed.1 Sec.9 IEC 62321:2008 Ed.1 Sec.10 ICP-OES 2 mg/kg IEC 62321:2008 Ed.1 Sec.8 Cadmium (Cd) IEC 62321:2008 Ed.1 Sec.9 IEC 62321:2008 Ed.1 Sec.10 ICP-OES 2 mg/kg Mercury (Hg) IEC 62321:2008 Ed.1 Sec.7 ICP-OES 2 mg/kg Hexavalent Chromium (Cr(VI)) IEC 62321:2008 Ed.1 Annex B / UV-Vis IEC 62321:2008 Ed.1 Annex C 2 mg/kg Fluorine (F) Refer to BS EN 14582:2007 IC 10 mg/kg Chlorine (Cl) Refer to BS EN 14582:2007 IC 10 mg/kg Bromine (Br) Refer to BS EN 14582:2007 IC 10 mg/kg Iodine (I) Refer to BS EN 14582:2007 IC 10 mg/kg Perfluorooctane Sulfonates(PFOS) Refer to US EPA 3550C:2007 LC-MS-MS 5 mg/kg Perfluorooctanoic Acid(PFOA) Refer to US EPA 3550C:2007 LC-MS-MS 5 mg/kg Polycyclic Aromatic Hydrocarbons Refer to US EPA 3550C:2007 & US EPA (PAHs) 8270D:2007 GC-MS 0.2 mg/kg Polybrominated Biphenyls (PBBs) IEC 62321:2008 Ed.1 Annex A GC-MS 5 mg/kg Polybrominated Diphenyl Ethers (PBDEs) IEC 62321:2008 Ed.1 Annex A GC-MS 5 mg/kg

Report No. Page 3 of 11 Test Result(s) (1) (2) (3) (4) Lead (Pb) Cadmium (Cd) Mercury (Hg) Hexavalent Chromium (Cr(VI)) / / / Perfluorooctanoic Acid(PFOA) Perfluorooctane Sulfonates(PFOS) (5) (6) (7) Lead (Pb) Cadmium (Cd) Mercury (Hg) Hexavalent Chromium (Cr(VI)) / Perfluorooctanoic Acid(PFOA) Perfluorooctane Sulfonates(PFOS) Conclusion (1) (2) (4) (7) Hexavalent Chromium (Cr(VI)) Negative Negative Negative Negative

Report No. Page 4 of 11 Test Result(s) (1) (2) (3) (4) Polybrominated Biphenyls(PBBs) Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Pentabromobiphenyl Hexabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Polybrominated Diphenyl Ethers(PBDEs) Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether

Report No. Page 5 of 11 Test Result(s) (5) (6) (7) Polybrominated Biphenyls(PBBs) Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Pentabromobiphenyl Hexabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Polybrominated Diphenyl Ethers(PBDEs) Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether

Report No. Page 6 of 11 Test Result(s) (3) (5) (6) Halogen(s) Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Polycyclic Aromatic Hydrocarbons(PAHs) Naphthalene Acenaphthylene Acenaphthene Fluorene Phenanthrene Anthracene Fluoranthene Pyrene Chrysene Benzo[a]anthracene Benzo[b]fluoranthene Benzo[k]fluoranthene Benzo[j]fluoranthene Benzo[a]pyrene Benzo[e]pyrene Indenol[1,2,3-cd]pyrene Dibenz[a,h]anthracene Benzo[g,h,i]perylene (6) 4.6 mg/kg

Report No. Page 7 of 11 Tested Sample/Part Description (1) Gray metal foil (2) Silvery metal foil (3) Beige-white paper (4) Silvery metal pin (5) Yellow liquid (6) Black rubber (7) Silver-white metal case Note: The samples had been dissolved totally tested for Lead, Cadmium, Mercury. -MDL = Method Detection Limit - = Not Detected (<MDL) -mg/kg = ppm = parts per million Negative = Absence of Cr(VI), the detected Cr(VI) concentration in the boiling water extraction solution is less than 0.02 mg/kg with 50cm 2 sample surface area used. Test Process 1. Lead(Pb), Cadmium(Cd) (1)IEC 62321:2008 Ed.1 Sec.8 Weigh sample and place it in a microwave digestion vessel Add digestion reagent Digest sample in microwave digestion oven Analyzed by Dry Ashing/ Alkali Fusion/ Acid Dissolution Residue Filtration ICP-OES deionized water Solution (2)IEC 62321:2008 Ed.1 Sec.9 Weigh sample and place it in a conical flask Add digestion reagent Digest the sample Analyzed by Dry Ashing/ Alkali Fusion/ Acid Dissolution Residue Filtration ICP-OES deionized water Solution

Report No. Page 8 of 11 (3)IEC 62321:2008 Ed.1 Sec.10 Weigh sample and place it in a microwave digestion vessel Add digestion reagent Digest sample in microwave digestion oven Analyzed by Dry Ashing/ Alkali Fusion/ Acid Dissolution Residue Filtration ICP-OES deionized water Solution 2. Mercury(Hg) Weigh sample and place it in a microwave digestion vessel Add digestion reagent Digest sample in microwave digestion oven Analyzed by Dry Ashing/ Alkali Fusion/ Acid Dissolution Residue Filtration ICP-OES deionized water Solution 3. Hexavalent Chromium(Cr(VI)) (1) IEC 62321:2008 Ed.1 Annex B Select a test sample measuring about 50±5cm 2 Extraction with boiling water Filter and remove the sample Analyzed by UV-Vis Add test solution Adjust the ph value of the solution (2) IEC 62321:2008 Ed.1 Annex C Weigh sample and place it in a conical flask Add digestion solution Heat at 90-95 for 3 hours Add test solution Adjust the ph value of the solution Cool and filter Adjust the ph value of the solution deionized water Analyzed by UV-Vis

Report No. Page 9 of 11 4. Polybrominated Biphenyls(PBBs), Polybrominated Diphenyl Ethers(PBDEs) Weigh sample and place it in a thimble Extracted with organic solvent Concentrate the extract Analyzed by GC-MS organic solvent Transfer the extract into a volumetric flask 5. Fluorine(F), Chlorine(Cl), Bromine(Br), Iodine(I) Weigh and place sample in a sample cup of bomb Fill the bomb with oxygen Combust the sample in oxygen bomb Analyzed by IC ultra-purity water Transfer the sample solution into a volumetric flask 6. Perfluorooctanoic Acid(PFOA), Perfluorooctane Sulfonates (PFOS) Weigh sample and place it in the glass tube Extracted with organic solvent in a ultrasonic equipment Concentrate the extract Analyzed by LC-MS-MS organic solvent Transfer the extract into a volumetric flask 7. Polycyclic Aromatic Hydrocarbons(PAHs) Weigh sample and place it in a thimble Extracted with organic solvent Concentrate the extract Analyzed by GC-MS organic solvent Transfer the extract into a volumetric flask

Report No. Page 10 of 11 Photo(s) of the sample(s) (1) (2) (3) (4)

Report No. Page 11 of 11 Photo(s) of the sample(s) (5) (6) (7) *** End of Report *** The test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CTI, this report can t be reproduced except in full.