Shear Behaviour of Fin Plates to Tubular Columns at Ambient and Elevated Temperatures

Similar documents
Improving fire resistance of existing concrete slabs by concrete topping

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

STRUCTURAL RESPONSE OF K AND T TUBULAR JOINTS UNDER STATIC LOADING

A CONNECTION ELEMENT FOR MODELLING END-PLATE CONNECTIONS IN FIRE

If the number of unknown reaction components are equal to the number of equations, the structure is known as statically determinate.

Module 6. Approximate Methods for Indeterminate Structural Analysis. Version 2 CE IIT, Kharagpur

CE5510 Advanced Structural Concrete Design - Design & Detailing of Openings in RC Flexural Members-

University of Sheffield The development of finite elements for 3D structural analysis in fire

Chapter 11. Displacement Method of Analysis Slope Deflection Method

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

Stress Analysis Lecture 3 ME 276 Spring Dr./ Ahmed Mohamed Nagib Elmekawy

Experimental Tests and Numerical Models of Double Side Non-Welded T RHS Truss Joints

FLEXIBILITY METHOD FOR INDETERMINATE FRAMES

Standardisation of UHPC in Germany

Structural Steelwork Eurocodes Development of A Trans-national Approach

Problem d d d B C E D. 0.8d. Additional lecturebook examples 29 ME 323

FINITE ELEMENT ANALYSIS OF TAPERED COMPOSITE PLATE GIRDER WITH A NON-LINEAR VARYING WEB DEPTH

Experiment Two (2) Torsional testing of Circular Shafts

OUTCOME 1 - TUTORIAL 3 BENDING MOMENTS. You should judge your progress by completing the self assessment exercises. CONTENTS

Assignment 1 - actions

EFFECT OF TRANSIENT THERMAL STRAIN ON THE BUCKLING OF SLENDER CONCRETE AND CONCRETE-FILLED COLUMNS IN FIRE

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

UNIT IV FLEXIBILTY AND STIFFNESS METHOD

Seismic design of bridges

MAAE 2202 A. Come to the PASS workshop with your mock exam complete. During the workshop you can work with other students to review your work.

Presented by: Civil Engineering Academy

[5] Stress and Strain

Unit III Theory of columns. Dr.P.Venkateswara Rao, Associate Professor, Dept. of Civil Engg., SVCE, Sriperumbudir

THEME IS FIRST OCCURANCE OF YIELDING THE LIMIT?

Engineering Science OUTCOME 1 - TUTORIAL 4 COLUMNS

Mechanical Engineering Ph.D. Preliminary Qualifying Examination Solid Mechanics February 25, 2002

Laboratory 4 Bending Test of Materials

ME Final Exam. PROBLEM NO. 4 Part A (2 points max.) M (x) y. z (neutral axis) beam cross-sec+on. 20 kip ft. 0.2 ft. 10 ft. 0.1 ft.

Mechanical Properties of Materials

FURTHER RESEARCH ON CHORD LENGTH AND BOUNDARY CONDITIONS OF CHS T- AND X-JOINTS

Deterministic and stochastic investigation of welded, high strength steel T joint

Influence of column web stiffening on the seismic behaviour of beam-tocolumn

CHAPTER 6: ULTIMATE LIMIT STATE

Chapter 4. Test results and discussion. 4.1 Introduction to Experimental Results

NAME: Given Formulae: Law of Cosines: Law of Sines:

SLOPE-DEFLECTION METHOD

PLASTIC COLLAPSE MECHANISMS IN COMPRESSED ELLIPTICAL HOLLOW SECTIONS

PDDC 1 st Semester Civil Engineering Department Assignments of Mechanics of Solids [ ] Introduction, Fundamentals of Statics

Module 11 Design of Joints for Special Loading. Version 2 ME, IIT Kharagpur

DESIGN OF BEAM-COLUMNS - II

Structural Steelwork Eurocodes Development of a Trans-National Approach

Lecture 4: PRELIMINARY CONCEPTS OF STRUCTURAL ANALYSIS. Introduction

CRACK FORMATION AND CRACK PROPAGATION INTO THE COMPRESSION ZONE ON REINFORCED CONCRETE BEAM STRUCTURES

CAPACITY DESIGN FOR TALL BUILDINGS WITH MIXED SYSTEM

SHEAR LAG IN SLOTTED-END HSS WELDED CONNECTIONS

Special edition paper

NUMERICAL EVALUATION OF THE ROTATIONAL CAPACITY OF STEEL BEAMS AT ELEVATED TEMPERATURES

2012 MECHANICS OF SOLIDS

DEFORMATION CAPACITY OF OLDER RC SHEAR WALLS: EXPERIMENTAL ASSESSMENT AND COMPARISON WITH EUROCODE 8 - PART 3 PROVISIONS

EUROCODE EN SEISMIC DESIGN OF BRIDGES

TRANSVERSE PLATE-TO-SQUARE/RECTANGULAR HSS CONNECTIONS

Structural Steelwork Eurocodes Development of A Trans-national Approach

Structural Analysis. For. Civil Engineering.

PLASTIC DEFORMATION CAPACITY OF H-SHAPED STEEL BEAM CONNECTED TO CONCRETE FILLED STEEL TUBULAR COLUMN

Low Cycle Fatigue Behavior of a Reduced End Plate Moment Connection (T-Stub)

Mechanics of Solids. Mechanics Of Solids. Suraj kr. Ray Department of Civil Engineering

FCP Short Course. Ductile and Brittle Fracture. Stephen D. Downing. Mechanical Science and Engineering

7 STATICALLY DETERMINATE PLANE TRUSSES

Application nr. 7 (Connections) Strength of bolted connections to EN (Eurocode 3, Part 1.8)

Fundamentals of Structural Design Part of Steel Structures

Longitudinal buckling of slender pressurised tubes

Lap splice length and details of column longitudinal reinforcement at plastic hinge region

THE DEVELOPMENT OF A COMPONENT-BASED CONNECTION ELEMENT FOR ENDPLATE CONNECTIONS IN FIRE

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

ENG1001 Engineering Design 1

Canadian Journal of Civil Engineering. RHS-to-RHS Axially Loaded X-Connections near an Open Chord End. Journal: Canadian Journal of Civil Engineering

Finite Element Modelling with Plastic Hinges

THE EC3 CLASSIFICATION OF JOINTS AND ALTERNATIVE PROPOSALS

Made by PTY/AAT Date Jan 2006

Experimental investigation on monotonic performance of steel curved knee braces for weld-free beam-to-column connections

INFLUENCE OF FLANGE STIFFNESS ON DUCTILITY BEHAVIOUR OF PLATE GIRDER

STRENGTH OF MATERIALS-I. Unit-1. Simple stresses and strains

SECTION 7 DESIGN OF COMPRESSION MEMBERS

3. Stability of built-up members in compression

CIVIL DEPARTMENT MECHANICS OF STRUCTURES- ASSIGNMENT NO 1. Brach: CE YEAR:

1 of 12. Law of Sines: Stress = E = G. Deformation due to Temperature: Δ

DESIGN GUIDES FOR HIGH STRENGTH STRUCTURAL HOLLOW SECTIONS MANUFACTURED BY SSAB - FOR EN 1090 APPLICATIONS

Name :. Roll No. :... Invigilator s Signature :.. CS/B.TECH (CE-NEW)/SEM-3/CE-301/ SOLID MECHANICS

Downloaded from Downloaded from / 1

CHAPTER 4. Design of R C Beams

ENGINEERING COUNCIL DIPLOMA LEVEL MECHANICS OF SOLIDS D209 TUTORIAL 3 - SHEAR FORCE AND BENDING MOMENTS IN BEAMS

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

Design of Beams (Unit - 8)

GATE SOLUTIONS E N G I N E E R I N G

Design of AAC wall panel according to EN 12602

Impact loading of ductile rectangular plates

Theory of structure I 2006/2013. Chapter one DETERMINACY & INDETERMINACY OF STRUCTURES

Structural Analysis I Chapter 4 - Torsion TORSION

PERIYAR CENTENARY POLYTECHNIC COLLEGE PERIYAR NAGAR - VALLAM THANJAVUR. DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK

STRESS. Bar. ! Stress. ! Average Normal Stress in an Axially Loaded. ! Average Shear Stress. ! Allowable Stress. ! Design of Simple Connections

Limit analysis of brick masonry shear walls with openings under later loads by rigid block modeling

JUT!SI I I I TO BE RETURNED AT THE END OF EXAMINATION. THIS PAPER MUST NOT BE REMOVED FROM THE EXAM CENTRE. SURNAME: FIRST NAME: STUDENT NUMBER:

The University of Melbourne Engineering Mechanics

Eurocode 8 Part 3: Assessment and retrofitting of buildings

Research Collection. Numerical analysis on the fire behaviour of steel plate girders. Conference Paper. ETH Library

Transcription:

Shear Behaviour of Fin Plates to Tubular Columns at Ambient and Elevated Temperatures Mark Jones Research Student, University of Manchester, UK Dr. Yong Wang Reader, University of Manchester, UK

Presentation Research background Current connection design guidance Fin-plate Test results Hollow & concrete-filled tubular (CFT) columns Ambient Elevated temperature Potential new approach to calculation of connection ultimate strength 2

Background Fin-plate connections a common solution for CFTbeam connections Research into such connections not advanced for fire engineering design In fire situations catenary action will occur if joints sufficiently robust Little current physical data re. such connections to CFTs, especially circular columns 3

Eurocode 3 Guidance; Fin-plate under shear and bending Plate Shear Resistance: Incorporating plastic moment resistance: V M = A( f / 3), y pl Rd 2V = M 1 Sd, fin 1 V pl, Rd V. Rd pl. Rd 2 And: M = V L. V. Rd Sd. fin 4

Current Design Guidance for CFT Component 1. Punching shear check 2. Shear yield strength adjacent to welds = ( ) CIDECT guidance for connections to hollow RHS tubes only Hollow tube guidance based on curve-fitted yield line analysis Deformation limits imposed 3%b 0 for tensile force Φ<0.1 rad. for bending case t f F u,0 < F y, p V 2V 2A f 3 / γ Sd pl. Rd. local v y M 0 5

Experimental Test Program Specimens represent finplate connections under shear and bending force Load imparted at one end of rig Connection anchored such that rotation allowed Test rig Electric kiln surrounding specimen used for steadystate tests at temperature 6

Test Rig Hinge allows rotation Roller base allows lateral movement 7

Test Specimens Specimen classification SFS square concrete-filled sections CFS circular concrete-filled section CHS circular hollow sections SHS square hollow sections Other test variables Column thickness, t c, 5 or 12.5mm Fin-plate thickness, t f, 6 or 10mm Lever arm, 30 or 60mm Temperature, 400-600 C 8

Failure Modes Failure mode (a) Failure mode (b) Failure of fin-plate due to bending and shear Tear-out of column face around the weld 9

Ambient Test Results Tests Difference Failure mode effect Load effect A1 & A5 A1 CFT A5 hollow (a) (b) 36% increase in load due to concrete in-fill A2 & A4 A2 CFT A4 hollow (b) (b) 28% increase in load due to concrete in-fill A3 & A4 A3 t f = 6mm A4 t f = 10mm (a) (b) 38% increase in load with thicker fin-plate 10

Observations Considering test pairs 1 & 5 and 2 & 4; Variable is presence of concrete in-fill Idealized strain along connection length For a given F, T is less & therefore CFT fails at higher load 11

Fin-plate theory alone? Test no. Test failure load, T L (kn) Theoretical failure load, F L (kn) T L /F L A1 94.6 125.3 0.755 A3 92.5 125.3 0.738 Fin-plate guidance alone insufficient Strength of column side is influential re. failure load and mode even if failure mode is in the fin-plate 12

Elevated Temp. Test Results Test No. Column Type Temp. ( C) Column, t c (mm) Fin-plate, t f (mm) Failure Load (kn) Failure Mode T1 CFS 400 5 6 130.7 (a) T2 CFS 600 12.5 6 51.1 (a) T3 CFS 600 5 6 49.6 (a) T4 CFS 500 12.5 6 85.5 (a) T5 SFS 400 5 6 133.8 (a) T6 SFS 600 5 6 53.3 (a) T7 CFS 600 5 10 67.4 (b) T8 CFS 400 5 10 133.4 (b) 13

Experimental Conclusions A number of tests have been performed upon fin-plate connections to CFT columns under shear load Concrete in-fill modifies load transfer mechanism to column face, changing relative strength of column face Connection failure mode depends on relative strengths of connection components The change in mechanism influences failure load and failure mode 14

Referring back 1. Punching shear check 2. Shear yield strength adjacent to welds = ( ) CIDECT guidance for connections to hollow RHS tubes only Hollow tube guidance based on curve-fitted yield line analysis Deformation limits imposed 3%b 0 for tensile force Φ<0.1 rad. for bending case t f F u,0 < F y, p V 2V 2A f 3 / γ Sd pl. Rd. local v y M 0 15

Shortcomings of current guidance 1. Load at deformation limit calculated, not ultimate load 2. Yield lines may not actually develop 3. Membrane action may result in higher ultimate loads and deformations 16

Deformation limits: test examples 120 100 80 A1 CFT column 8 %b 0 0.27 rads. Load (kn) 60 40 20 3%b 0 limit Test A1 Test A5 A5 Hollow column 13 %b 0 0.28 rads. 0 0 2 4 6 8 10 12 14 Displacement (mm) Failure load greater than that at 3%b 0 limit. Connections more robust than current guidance allows for. 17

Starting point Simplest loading situation is tensile force only Column side walls restricted by concrete in-fill Area of column face above and below connection is influential 18

Establishing basic principles F. δ = m P. L 4 Equilibrium equation 2 F. L = P. δ m Work method m Derive expression from equilibrium equations by treating the plate as beam under point load 19

Results for plate only 3000 2500 Failure Load (kn) 2000 1500 1000 500 F.E. Equilibrium Equation 1 Equilibrium Equation 2 0 0 0.005 0.01 0.015 0.02 Column Thickness (m) Equations work well when considering the full-length plate connection Work equation is therefore suitable for adoption 20

Extension of procedure Decide upon deformation mechanism and apply work equation along the lines 21

Long columns, short fin-plates 1000 900 800 Load (kn) 700 600 500 400 300 200 100 0 fin = 0.4 m fin = 0.2 m Work equation, fin = 0.4 m Work equation, fin = 0.2 m 0 0.005 0.01 0.015 Column thickness (m) 22

contd. Zone assumed to extend b 0 /2 above and below connection Linear internal work force and L distributions assumed 23

First approximation 1000 1000 900 900 Load (kn) 800 700 600 500 400 t = 5 mm F.E. t = 10 mm F.E. t = 5 mm, Work method t = 10 mm, Work method Load (kn) 800 700 600 500 400 t = 5 mm, F.E. t = 10 mm, F.E. t = 5 mm, W.M. t = 10 mm, W.M. 300 300 200 200 100 100 0 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Plate Length (m) b 0 = 0.4 m 0 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Plate Length (m) b 0 = 0.6 m 1 st approximation is slightly greater than F.E. result Estimate of internal work along diagonal yield lines requires revision Difference is consistent, indicating method may be correct 24

Unresolved issues Deflection, δ m, currently obtained from F.E. results Internal work distribution along diagonal yield lines requires approximation Adapting method to connections under bending and shear force 25

Thank you 26