REVIEW OF LAB TECHNIQUES

Similar documents
REVIEW OF LAB TECHNIQUES

KINETICS: INITIAL RATES

THE IRON(III) THIOCYANATE REACTION SYSTEM

THE TEMPERATURE DEPENDENCE OF THE EQUILIBRIUM CONSTANT

KINETICS OF THE PERMANGANATE- ISOPROPYL ALCOHOL REACTION

Density of Aqueous Sodium Chloride Solutions

Density of Aqueous Sodium Chloride Solutions

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law

MEASUREMENT: PART II

Spectrophotometric Determination of the Copper (II) Sulfate Pentahydrate Content in a Mixture

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Analysis of Aspirin. Prepared by Masanobu Yamauchi and Ross S. Nord, Eastern Michigan University PURPOSE

Kinetics of Crystal Violet Bleaching

pka AND MOLAR MASS OF A WEAK ACID

ANALYSIS OF ALUMINUM(III) IN WATER

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

EXPERIMENT #3 A Beer's Law Study

Introduction to Chemistry Techniques Prelab (Week 1) 2. Determine the number of significant figures in each of the following numbers.

The Determination of an Equilibrium Constant

DETERMINATION OF AN EQUILIBRIUM CONSTANT

Experiment 11 Beer s Law

Experiment 11 Beer s Law

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

A Study of Beer s Law Prelab

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Introduction to Spectroscopy: Analysis of Copper Ore

Experiment 7A ANALYSIS OF BRASS

CHEM 122 LABORATORY SKILLS EXAMINATION

Introduction to Spectroscopy: Analysis of Copper Ore

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Lab 5: Calculating an equilibrium constant

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore

EXPERIMENT 6 INTRODUCTION TO SPECTROSCOPY

Spectrophotometric Determination of an Equilibrium Constant

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Experimental Procedure Lab 402

Determination of an Equilibrium Constant

Titration of an Unknown Acid

Introduction to Spectroscopy: Analysis of Copper Ore

TITRATION CURVES INTRODUCTION. Read and/or review Sections 4.10 and 16.7 in your textbook.

Spectroscopy II Introduction: Spectrophotometry and Fluorometry

Experiment 20-Acid-Base Titration: Standardization of KOH and Determination of the Molarity and/or Percent Composition of an Acid Solution

Investigating Food Dyes in Sports Beverages. Sample

PRELIMINARY ACTIVITY FOR

Experiment 13I THE REACTION OF RED FOOD COLOR WITH BLEACH 1

CH 112 Special Assignment #4 Chemistry to Dye for: Part C

Chemistry 213. A KINETIC STUDY: REACTION OF CRYSTAL VIOLET WITH NaOH LEARNING OBJECTIVES

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

Determining the Concentration of a Solution: Beer s Law

Experiment 7. Determining the Rate Law and Activation Energy for the Reaction of Crystal Violet with Hydroxide Ion

Experiment 6: Determination of the Equilibrium Constant for Iron Thiocyanate Complex

for a Weak Acid 1-ring stand stir plate and stir bar ph Probe ml burette 1-50 ml and ml beaker Drop counter ph 7.00 buffer 0.

Experiment 8 Introduction to Volumetric Techniques I. Objectives

aa + bb cc + dd Equation 1

Experiment #7. Determination of an Equilibrium Constant

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Using Conductivity to Find an Equivalence Point

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Analysis of Hypochlorite in Bleach

Titration of Acids and Bases

CHEM 334 Quantitative Analysis Laboratory

The Chemical Reaction In neutral solution, crystal violet dye exists as a cation with an intense purple color. In basic -

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Equilibrium and Ionic Strength Effects

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

CHM 152 updated May 2011 Lab 6: Experimentally Determining an Equilibrium Constant using Spectrophotometry

Order of a Reaction. Using Labquest and Colorimeter. Teachers Guide

K = [C]c [D] d [A] a [B] b (5)

Lab 5 Enthalpy of Solution Formation

The Synthesis and Analysis of Aspirin

Spectrophotometric Determination of pka of Phenol Red

EXPERIMENT 23. Determination of the Formula of a Complex Ion INTRODUCTION

The Determination of an Equilibrium Constant

Microscale Acid-Base Titration

Beer's Law and Data Analysis *

Acid-Base Titration. Evaluation copy

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Solvation and Freezing Point Depression

Laboratory Measurements and Procedures

Determining the Conductivity of Standard Solutions

Chemistry 1215 Experiment #11 Spectrophotometric Analysis of an Unknown Brass Sample

Solution Calorimetry

Acid-Base Titration Curves Using a ph Meter

Solution Calorimetry

Concentrations that absorb. Measuring percentage transmittance of solutions at different concentrations

POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE?

Experiment 12: SPECTROSCOPY: EMISSION & ABSORPTION

Chemical Equilibrium: Finding a Constant, Kc

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Beer s Law: Determining the Concentration of a Solution

Acid-Base Titration Curves Using a ph Meter

The Determination of an Equilibrium Constant

ACID-BASE TITRATION (MICROSCALE)

Transcription:

Experiment 1 REVIEW OF LAB TECHNIQUES Prepared by Masanobu M. Yamauchi and Ross S. Nord, Eastern Michigan University PURPOSE To review density calculations, Beer s Law and the use of electronic balances, volumetric glassware, and spectrometers. BEER'S LAW Colored species in solution absorb visible light. As the amount (concentration) of the species increases, so will the amount of light it absorbs. The fraction of incident light that passes through a solution, without being absorbed, is called the transmittance T, which is defined as T = I I 0 (1) where I is the intensity of light emerging from the solution and I 0 is the intensity of light that entered the solution. Percent transmittance %T is the percent equivalent of the fraction T: %T = I I 0 x 100% (2) If all of the light is absorbed then %T = 0. If all of the light is transmitted then %T = 100. Although %T decreases as the concentration of a colored species increases, the relationship is not linear. However, the concentration is a linear function of the logarithm of %T. Therefore, a quantity which is linear in concentration, called the absorbance A, has been defined: A = 2 log %T (3) This definition, utilizing common logs, is a relic from the days before electronic calculators when logarithms were obtained from "log tables." It is a convenient choice since A = 0 when %T=100. The equation describing how the absorbance A depends on concentration is referred to as Beer's law (although Mr. Beer was not solely responsible for it): A = εbc (4) where is the molar absorptivity or the molar extinction coefficient, b is the path length (the distance the light travels through the solution), and c is the molar concentration of the absorbing species. The molar absorptivity is different at each wavelength. It will have its maximum value at the wavelength of light most efficiently absorbed by the colored species. Therefore, because the absorbance A is unitless (which should be clear from its definition, see eq. 3), the units of must be the reciprocal of the units of b times c. can be determined by measuring the absorbance for a solution of known b and c. The concentration of an unknown solution can then be determined by measuring A and solving Beer's law for c. IN THIS EXPERIMENT You will prepare a 0.0500 M CuSO4(aq) solution and measure its density. The absorbance of this solution will be measured at 680 nm and 710 nm to determine its molar absorptivity at those wavelengths (demonstrating that changes with wavelength). The concentration of an unknown solution of CuSO4(aq) will then be determined by measuring its absorbance and using Beer's law. 1-1

PRE-LABORATORY PREPARATION 1. Read the background, procedure and data analysis sections of the experiment. 2. Review the use of volumetric glassware (pipets and volumetric flasks) and density calculations. 3. Answer the question on Beer's Law in the Data Analysis section. EXPERIMENTAL SECTION REAGENTS PROVIDED 0.500 M CuSO 4. Unknown CuSO 4 solution. Hazardous Chemicals Cu 2+ is somewhat toxic. The oral LD50 for rats is 300 mg/kg. A 1 kg rat has a 50% chance of dying if it drinks 10 ml of the 0.500 M solution. WASTE DISPOSAL Discard Cu 2+ solutions in the designated bottles. PROCEDURE PREPARATION OF 0.0500 M CuSO 4 You will do this part individually. 1. Practice using a 10-mL pipet by filling it with distilled water and transferring the water to a 250-mL beaker. Repeat until you feel confident of your ability to use a pipet accurately. 2. Rinse your pipet. Take about 30 ml of the 0.500 M CuSO4 in a clean, dry 100-mL beaker. Do not take more than you need. Rinse your pipet twice with two small portions of the CuSO4 solution (slightly more than a pipet stem full). Discard the rinsings in a 250-mL beaker which you should use as your temporary waste solution container. 3. Pipet 10 ml of the CuSO 4 into a 100 ml volumetric flask. Fill to the mark with distilled water, cap the flask and invert several times to mix. The density and spectrophotometric studies can be done in either order. Begin by doing the study for which you can most readily obtain access to the necessary equipment. DETERMINATION OF DENSITY You will do this part individually. 4. Rinse your pipet with the 0.0500 M CuSO 4 solution that you prepared. Discard your rinsings as before. 5. Place a clean, dry 50-mL Erlenmeyer flask on an electronic balance, tare (zero) the balance, and then transfer 10.00 ml of the 0.0500 M CuSO 4 into the flask. This transfer should be done while the flask is on the table top, not while it is on the balance pan. This is to avoid the possibility of spilling chemicals on the balance. 6. Record on your Data Sheet (in ink) the mass of the solution transferred. Always record your data readings as precisely as possible. So, record the mass to the nearest 0.001 g. If the last digit is fluctuating (which often occurs) record what you estimate is its average value. 1-2

7. Tare the balance again (while the flask is still on the balance), remove the flask, and then add a second 10-mL aliquot to the flask. Place the flask back on the balance and record the mass. If, in your judgment, the readings are too different, repeat until you have two reasonably consistent values. SPECTROPHOTOMETRIC ANALYSIS This part may be done with a partner. 8. Disconnect the LabPro interface box from the USB cable and connect the cable to the SpectroVis spectrophotometer. Note the words spectrophotometer and spectrometer are used interchangeably. 9. Start up LoggerPro. In the upper left corner of the screen there should be a small icon of a spectrum. If, it says No Device Connected the spectrophotometer is not properly connected to the computer. Check your cable connections. If properly connected, LoggerPro will immediately recognize the spectrometer. Get help, if needed. 10. Calibrate the spectrometer. (a) Click on Experiment from the menu line at the top of the screen. Next click on Calibrate and click on Spectrometer: 1. (b) Allow the spectrometer to go through the 60 second warm up if you have just connected it. (Otherwise, you may skip the warm up.) (c) Insert a cuvet, filled about 3/4 the way with distilled water, into the spectrometer. (This is called the blank cuvet.) The clear sides of the cuvet should be facing left & right (in the direction of the on the spectrometer). (d) Click on Finish Calibration. The calibration will finish in a couple of seconds. Then click on OK. 11. Obtain the absorbance spectrum (A vs. ) of the 0.0500 M CuSO 4 solution you prepared. a) Prepare your sample cuvet. It should be filled about 3/4 the way to the top. The outside of the cuvet should be carefully dried with a Kimwipe. b) Remove the blank cuvet and insert the sample cuvet into the spectrometer. As always, the clear sides must be oriented so that the light beam goes through them. The direction of the light beam is indicated by the on the spectrometer. c) By default, LoggerPro starts in this data collection mode. If you have changed to a different mode, you can change back by clicking on the Configure Spectrometer icon (which is the colorful spectrum icon near the right end of the top row of icons) and then click on Abs vs Wavelength and click OK. d) Click on Collect (in the upper right, at the end of the row of icons). If you have previously collected any data, you will be given the opportunity to save that data before it is erased. If you do not want it saved, simply click on Erase and Continue. e) The spectrum should be displayed almost instantly. Wait a few seconds for it to roughly stabilize and then click on Stop (located where the Collect icon had been). f) On your data sheet, record the absorbances found in the LoggerPro data table at 680 nm and at 710 nm (or the closest wavelengths to them, if your spectrometer does not take readings at those exact wavelengths). The absorbance at any given wavelength can be read from the data table on the left side of the screen (using the scroll bar as necessary). Typically, absorbances are displayed to the nearest 0.001 and should be recorded as such. 12. Title your graph and then print it. To add a title, double click anywhere on the graph and then type a title in the dialog box that appears. A good title tells you something about the graph (such as Absorbance vs. Wavelength for 0.0500 M Copper(II) Sulfate). Click on Done. To print the graph click on File, in the upper left corner, then Print Graph. If the Printing Options dialog box appears, you can optionally add a footer with your name(s). 1-3

13. Obtain about 20 ml of an unknown CuSO 4 solution in a clean beaker. Rinse a cuvet with the unknown, fill the cuvet (3/4 of the way to the top), and then measure its absorbance spectrum, as in Step 11. Again, record the absorbances at 680 nm and at 710 nm on your data sheet. Also, record the unknown number. 14. Close the LoggerPro program. The spectrophotometer will not turn off until it is disconnected or the program is closed. Leaving it on will decrease its lifetime. 15. Wash your glassware and put it away. Do NOT dry the inside of the cuvets (or volumetric flasks) with paper towels. Shake them out, over a sink, a couple of times to remove most of the water (being careful not to spray the person standing next to you). It is always a good idea to wash your hands before leaving lab. 1-4

Name Station Used Instructor/Day/Time Station Checked & Approved DATA SHEET Record all values with the proper units and number of decimal places. Mass of 10.00 ml aliquots of 0.0500 M CuSO4 (take as many, or as few, readings as needed). Put a star (*) next to the good trials that you will use to calculate the density. Absorbance 680 nm 710 nm 0.0500 M CuSO4: unknown CuSO4: Unknown number: 1-5

DATA ANALYSIS Show ONE sample calculation for each problem. Each calculation should have the general formula, the formula with the numbers and units plugged in, and the answer with proper units and significant figures. 1. Calculate the density of the 0.0500 M CuSO 4. Assume that the volume of your pipet is 10.00 ml. Record the density for each good trial in the lines below. You should have a minimum of two good trials. Density of Good Trial 1 = Density of Good Trial 2 = Density of Good Trial 3 = Density of Good Trial 4 = Average Density = 2. Write Beer's Law and identify each term in it (on both sides of the equation). 3. Calculate the molar absorptivity of CuSO 4 at both 680 nm and at 710 nm, using the measured absorbances of the 0.0500 M solution that you prepared. (The path length of the cuvets is 1.00 cm.) 680 = 710 = 4. Using the measured absorbance of your unknown at 710 nm and the calculated molar absorptivity of CuSO 4 at 710 nm, determine the concentration of your unknown CuSO 4 solution. [CuSO4] = Unknown Number = 1-6