Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Similar documents
HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Chromatography 2010/2011. Thermo Scientific. Chromatography Columns and Consumables. Columns and Consumables

UCT. Selectively removing Chlorophyll without Compromising your Planar Pesticides INNOVATION THROUGH CHEMISTRY E N V I R O

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables.

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Basics in Solid Phase Extraction (SPE)

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Validation Report 18

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Sample Prep Options for GC users

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Validation of a Simple and Rapid Multiresidue Method (QuEChERS) and its Implementation in Routine Pesticide Analysis

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

HILIC Method Development in a Few Simple Steps

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

[ Care and Use Manual ]

Validation Report 8 Determination of pesticide residues in rice and wheat by GC-MS/MS and LC-MS/MS (QuEChERS method) Appendix 2

Sample Preparation Method Development for Complex Matrices Such as Foods by QuEChERS and Solid Phase Extraction (SPE)

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Advances in Sample Preparation for Accelerated Solvent Extraction

Application of the QuEChERS Sample Preparation Method for the Determination of Carbamate Pesticides in Flos Carthami Samples by UPLC-MS/MS

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Introduction to Fourier Transform Infrared Spectroscopy

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Agilent QuEChERS Kits

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Determination of trace anions in concentrated hydrofluoric acid

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Agilent Bond Elut QuEChERS Food Safety Applications Notebook: Volume 2 INNOVATIVE APPROACHES FOR TODAY S FOOD ANALYSIS CHALLENGES

Validation Report Determination of isoprothiolane residues in rice by GC-MS/MS (QuEChERS method)

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Analysis of Polycyclic Aromatic Hydrocarbons in Soil with Agilent Bond Elut HPLC-FLD

1 Introduction. Tomasz Rejczak, Tomasz Tuzimski* A review of recent developments and trends in the QuEChERS sample preparation approach

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Detection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC.

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution


Determination of Trace Cations in Power Plant Waters Containing Morpholine

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Gemini-NX Performance paired with Axia Technology

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

ab Carrez Clarification Reagent Kit

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Analytical Instrumentation

Highly Sensitive and Rugged GC/MS/MS Tool

Automated and accurate component detection using reference mass spectra

DETERMINATION OF CHLORAMPHENICOL RESIDUES IN HONEY BY MONOLITHIC COLUMN LIQUID CHROMATOGRAPHY MASS SPECTROMETRY AFTER USE OF QUECHERS CLEAN-UP

Transcription:

Thermo Scientific HyperSep Dispersive SPE Products Efficient sample preparation and clean-up using the QuEChERS Method

The QuEChERS method overcomes the problems associated with time consuming, expensive and labor intensive multiresidue methods (MRM). QuEChERS stands for Quick, Easy, Cheap, Effective, Rugged and Safe. The method, developed in 2003 by Anastassiades and Lehotay, is becoming the method of choice by many for food analysis. High sample throughput Determination of a large number of pesticide compounds No laborious steps and no need for automation Less solvent usage than conventional MRM s Detection of wide pesticide range (polars, ph-dependent compounds) Extraction in acetonitrile GC and LC amenable High recovery levels and accurate results Our comprehensive range of Dispersive SPE products contain the proper sorbents foroptimum extraction, clean-up and separation of analytes from complex matrices such as food using QuEChERS methods. Save valuable time in preparation products are supplied pre-prepared Reduced variability due to consistency in products and rigorous quality control Cleaner extracts from cleaner, pre-prepared products Lower peak counts as a result of using pre-prepared products QuEChERS methods products used For non-base sensitive compounds, such as bendiocarb and diuron using the original QuEChERS method: 1 Add 15mL of acetonitrile to QuEChERS centrifuge tube 2 Shake to mix contents. 3 Add surrogate or internal standards if necessary* 4 Add 15g of homogenised hydrated sample and shake for 1 minute 5 Centrifuge tube for 1 minute at 3700 rcf 6 Add an aliquot of the supernatent to the appropriate clean-up tube (and shake for 1 minute) 7 Centrifuge for 1 minute at 3700 rcf 8 Analyse extract 50mL PP centrifuge tube: 60105-211 2mL or 15mL clean-up tubes: 60105-202 60105-203 60105-204 60105-205 60105-206 60105-223 60105-224 60105-225 60105-226

For base sensitive compounds such as folpet and fungicides using the AOAC 2007.01 QuEChERS method: For non-base sensitive compounds using the European EN15662 Method: For polar aromatic (planar) compounds such as matrix plant pigments using the Schenck Method: 1 Add 15mL of 1% acetic acid in acetonitrile to QuEChERS centrifuge tube 2 Shake to mix contents 3 Add surrogate or internal standards if necessary* 4 Add 15g of homogenised hydrated sample and shake for 1 minute 5 Centrifuge tube for 1 minute at 3700 rcf 6 Add an aliquot of the supernatent to the appropriate clean-up tube and shake for 1 minute 7 Centrifuge for 1 minute at 3700 rcf 8 Analyse extract 50mL PP centrifuge tube: 60105-210 2mL or 15mL clean-up tubes: 60105-202 60105-203 60105-204 60105-205 60105-206 60105-223 60105-224 60105-225 60105-226 1 Weigh 15g of homogenised (hydrated at least 80%) sample in a 50mL centrifuge tube 2 Add 15mL acetonitrile (or 1:1 acetone/hexane, ethyl acetate) and IS 3 Shake briefly 4 Add 6g anhydrous magnesium sulfate, 1.5g sodium chloride, 1.5g sodium citrate Tribadic dihydrate, 0.75g sodium citrate dibasic 5 Shake by hand for 1 minute 6 Centrifuge at 5,000 rpm for 5 minutes 7 Transfer a portion of supernatent to a QuEChERS clean up tube 8 Shake for 30 seconds 9 Centrifuge for 1 minute at 6,000 rpm 50mL PP centrifuge tube: 60105-212 60105-216 2mL or 15mL clean-up tubes: 60105-215 60105-217 60105-218 60105-219 60105-221 60105-222 60105-227 1 Pre-rinse the cartridge with 5mL of toluene 2 Add an aliquot of the supernatent to the cartridge 3 Start collection 4 Elute with 6-12mL of 3:1 acetone :toluene 5 Concentrate for GC/MS analysis - or - 6 Concentrate to dryness and reconstitute in mobile phase for LC analysis 6mL columns: 60105-207 60105-208 60105-209 * Surrogate or internal standards may be required if subsequent analysis is required. We offer a complete range of standards visit www.thermoscientific.com for more information

Considerations in Method Development technical information 1. Determine the properties of the sample matrix: Matrix Type Examples Sorbent Requirements General Matrices Apples Cucumber Melon MgSO4, PSA Fatty Matrices Milk Cereals Fish MgSO4, PSA, C18 Pigmented Matrices Lettuce Carrot Wine MgSO4, PSA, C18, GCB High Pigmented Matrices Spinach Red Peppers MgSO4, PSA, C18, GCB 2. Determine the properties of the pesticides of interest: Base sensitive ph dependent Non-base sensitive Troubleshooting Problem Causes Recommended Solutions Loss of planar pesticides Presence of GCB may result in a loss of planar compounds Use a product with less GCB Use the Dual Phase QuEChERS product Loss of acidic compounds e.g. 2,4-D from starting matrix Presence of PSA will extract acidic compounds from matrix Use a product containing MgSO4 and C18 Loss of compounds during subsequent analysis Some compounds are unstable and can break down during analysis Use an analyte protectant e.g. toluene or sorbitol Addition of sample to QuEChERS Extraction tube containing sorbent causes an exothermic reaction Exothermic reaction between water in sample and MgSO4 Add the sample to the tube, then the solvents,m then the sorbent materials Poor recovery of pesticide compounds Sample not in appropriate homogenisation state Wrong products used in method Ensure sample is hydrated to 80% or higher Verify nature of pesticides e.g. are base sensitive compounds present

Thermo Scientific HyperSep Dispersive SPE products are available in a range of sorbent material combinations. Each of the sorbent materials is used to remove different interferences from the starting sample. The table below shows the different sorbent materials used and the compounds they are used to target. Extraction Tubes ordering info Size Contents Application Quantity Part No. 50mL 6g Anhydrous Magnesium Sulfate, 1.5g Anhydrous Sodium Acetate 4g Anhydrous Magnesium Sulfate, 1g Sodium Chloride 6g Anhydrous Magnesium Sulfate, 1.5g Sodium Chloride, 1.5g Sodium Citrate Tribadic Dihydrate, 750mg Sodium Citrate Dibasic Sesquihydrate 4g Anhydrous Magnesium Sulfate, 1g Sodium Chloride, 1g Sodium Citrate Tribadic Dihydrate, 500mg Sodium Citrate Dibasic Sesquihydrate This product is listed in the AOAC for the extraction of pesticide residues using the QuEChERS method. Primarily designed to preserve base sensitive compounds such as chlorothalonil, dichloofluanid, tolyfluanid, folpet, captafol, captan from non-acidic matrices. This product is used for the extraction of pesticide residues using the QuEChERS method. It is preferred when base sensitive compounds are not present or are not of analytical interest. Eliminating the buffer allows a cleaner extract, and sodium chloride aids in the extraction of the analytes. This product is the European version of 60105-210 and is used for the extraction of pesticide residues. It is preferred when base sensitive compounds are not an issue. 250 60105-210 60105-211 60105-212 60105-216 Columns Size Contents Application Quantity Part No. 6mL 200mg graphatized carbon on top, 400mg PSA on bottom, separated by a Teflon frit Used in the Schenck variation of QuEChERS, this product removes pigments, polar organic acids, some sugars and lipids from an aliquot of extract. 30 60105-207 250mg graphatized carbon on top, 500mg PSA on bottom, separated by a Teflon frit Schenck variation of QuEChERS, but with a different quantity of sorbents. When in doubt, use 60105-208. 60105-208 500mg graphatized carbon on top, 500mg PSA on bottom, separated by a Teflon frit 60105-209 The Schenck variation of QuEChERS introduces the use of PSA and graphatized carbon block to remove high levels of chlorophyll and plant sterols in the final extract without loss of planar pesticides using an acetone : toluene solvent mix (3:1). LC Columns and Consumables As a leader in HPLC column technology including silicia manufacturing, bonded phase production and column packing, you can rely on Thermo Scientific HPLC products. For over 30 years our innovation has pioneered the market with advanced products such as our Hypersil GOLD columns offering outstanding peak shape and consistent results. GC Columns and Consumables Thermo Scientific TRACE GC Columns offer high temperature stability and exhibit low bleed and long lifetimes. From general purpose non-polar to polar columns, many of which are MS-compatible, TRACE GC columns provide excellent quality and performance, with guaranteed results. Reagents and Standards We offer a wide range of high quality GC/HPLC reagents and solvents, which include: Silylation, Alkylation and Acylation reagents for GC derivatisation HPLC/GC Grade Solvents HPLC detection reagents for pre- and post-chromatographic techniques. All compounds and formulations are purified for chromatography, minimizing artefact formation

Clean-Up Tubes Size Contents Application Quantity Part No. ordering info 15mL 900mg Anhydrous Magnesium Sulfate, 300mg PSA & 150mg Carbon 900mg Anhydrous Magnesium Sulfate, 300mg PSA & 150mg endcapped C18 750mg Anhydrous Magnesium Sulfate, 250mg PSA, 250mg endcapped C18 & 250mg Carbon and lipids. This product will cause the loss of Designed for use with a 10mL aliquot of supernatent 50 60105-205 60105-206 60105-213 900mg Anhydrous Magnesium Sulfate & 300mg PSA 60105-214 900mg Anhydrous Magnesium Sulfate & 150mg PSA 60105-215 900mg Anhydrous Magnesium Sulfate, 150mg PSA & 45mg Carbon 900mg Anhydrous Magnesium Sulfate, 150mg PSA & 15mg Carbon 1200mg Anhydrous Magnesium Sulfate & 400mg PSA 1200mg Anhydrous Magnesium Sulfate, 400mg PSA & 400mg endcapped C18 1200mg Anhydrous Magnesium Sulfate, 400mg PSA, 400mg endcapped C18 & 400mg Carbon and lipids. 60105-217 60105-218 60105-224 60105-225 60105-226 900mg Anhydrous Magnesium Sulfate, 150mg 60105-227 150mg Anhydrous Magnesium Sulfate, 50mg PSA & 50mg Carbon 60105-230 900mg Anhydrous Magnesium Sulfate, 300mg PSA & 150mg ChloroFiltr Removal of chlorophyll. 60105-231 2mL 150mg Anhydrous Magnesium Sulfate & 25mg PSA and lipids. aliquot of supernatent 150mg Anhydrous Magnesium Sulfate, 25mg PSA & 25mg endcapped C18 Designed for use with a 2mL aliquot of supernatent 50 100 60105-219 60105-220 150mg Anhydrous Magnesium Sulfate, 25mg PSA & 2.5mg Carbon 150mg Anhydrous Magnesium Sulfate, 25mg PSA & 7.5mg Carbon 150mg Anhydrous Magnesium Sulfate, 50mg PSA, 50mg endcapped C18 & 50mg Carbon 150mg Anhydrous Magnesium Sulfate, 50mg PSA & 50mg Carbon 150mg Anhydrous Magnesium Sulfate, 50mg PSA 150mg Anhydrous Magnesium Sulfate, 50mg PSA & 50mg endcapped C18 planar pesticides and lipids. Removing polar organic acids, sterols, some 60105-221 60105-222 60105-223 60105-202 60105-203 60105-204 2009 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. North America: USA/Canada +1 866 984 3766 (866-9-THERMO) Europe: Austria +43 1 801 40 0, Belgium +32 2 482 30 30, France +33 2 2803 2180, Germany national toll free 08001-536 376, Germany international +49 6184 90 6940, Italy +39 02 02 95059 434-254-375, Netherlands +31 76 571 4440, Nordic/Baltic countries +358 9 329 100, Russia/CIS +7 (812) 703 42 15, Spain/Portugal +34 93 223 09 18, Switzerland +41 44 454 12 12, UK/Ireland +44 870 609 9203 Asia: China +86 21 6865 4588 or +86 10 8419 3588, India toll free 1800 22 8374, India +91 22 6716 2200, Japan +81 45 453 9220, Other Asian countries +852 2885 4613 Countries not listed: +49 6184 90 6940 or +33 2 2803 2180 BRGSCQUECHERS 1109 www.thermoscientific.com/columns