Microscale Acid-Base Titration

Similar documents
Microscale Acid-Base Titration

ACID-BASE TITRATION (MICROSCALE)

Acid-Base Titration. Sample

Acid-Base Titration. Volume NaOH (ml) Figure 1

Chemistry with Mr. Faucher. Acid-Base Titration

Acid-Base Titration. Evaluation copy

Acid-Base Titration. Computer OBJECTIVES

Determining the K sp of Calcium Hydroxide

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

HESS S LAW: ADDITIVITY OF HEATS OF REACTION

Standardization of a Primary Standard & Determination of Concentration by Acid-Base Titration

Additivity of Heats of Reaction: Hess s Law

Conductimetric Titration and Gravimetric Determination of a Precipitate

Conductimetric Titration and Gravimetric Determination of a Precipitate

Evaluation copy. Acids and Bases. computer OBJECTIVES MATERIALS

Determining the Concentration of a Solution: Beer s Law

Additivity of Heats of Reaction: Hess s Law

Name Date Period. 1. If drops of ACID are added to a ph buffer, then the ph of the buffer will [increase / decrease / stay the same].

Conductometric Titration & Gravimetric Determination of a Precipitate

H 2 CO 3 (aq) HNO 2 (aq) + HNO 3 (aq)

Heat of Combustion: Magnesium

Using Conductivity to Find an Equivalence Point

Acids and Bases. Figure 1. Logger Pro or graph paper

Determining the Concentration of a Solution: Beer s Law

Lab 5 Enthalpy of Solution Formation

Acids and Bases. Figure 1

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

Acid Rain. Evaluation copy

6 Acid Base Titration

Alkalinity. LabQuest INTRODUCTION

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Determining the Enthalpy of a Chemical Reaction

EXPERIMENT 6. Properties of Buffers INTRODUCTION

TITRATION CURVES INTRODUCTION. Read and/or review Sections 4.10 and 16.7 in your textbook.

Chemistry 3202 Lab 6 Hess s Law 1

Lab- Properties of Acids and Bases. Name. PSI Chemistry

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

Acid-Base Titration Curves Using a ph Meter

INTRODUCTION TO ACIDS, BASES AND TITRATION

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Titration of a strong acid with a strong base with Cobra4

The Decomposition of Hydrogen Peroxide. Evaluation copy

Titration with an Acid and a Base

The Determination of an Equilibrium Constant

Acid Rain. Computer OBJECTIVES

Chemical Equilibrium: Finding a Constant, Kc

EXPERIMENT 15. USING CONDUCTIVITY TO LOOK AT SOLUTIONS: DO WE HAVE CHARGED IONS OR NEUTRAL MOLECULES? rev 7/09

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background

Use quantitative and qualitative analyses to identify the powder in Mr. Orlow s car.

The Effect of Alcohol on Biological Membranes

Endothermic and Exothermic Reactions

Heat of Combustion: Magnesium. This equation can be obtained by combining equations (1), (2), and (3): (1) MgO(s) + 2 HCl(aq) MgCl 2 (aq) + H 2 O(l)

Acid-Base Titration Curves Using a ph Meter

The Synthesis and Analysis of Aspirin

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution, analysis of vinegar & antacid tablets

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

experiment7 Explaining the difference between analyte and standard solutions. Know the definition of equivalence point.

Titration of Acids and Bases

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

pka AND MOLAR MASS OF A WEAK ACID

Properties of Acids and Bases

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Experiment C-10 Titration of a Strong Acid and a Strong Base

EXPERIMENT 9 ENTHALPY OF REACTION HESS S LAW

Percentage of Acetic Acid in Vinegar

Reaction Stoichiometry

PRELIMINARY ACTIVITY FOR

Acid-Base Titration Lab

HESS S LAW: ADDITIVITY OF HEATS OF REACTION

Experimental Procedure

CONDUCTOMETRIC MEASUREMENTS

LABORATORY INVESTIGATION

The Determination of an Equilibrium Constant

Titration of a Cola Product INSTRUCTOR RESOURCES

Chemistry CP Lab: Additivity of Heats of Reaction (Hess Law)

THE IDENTIFICATION OF A SOLID ORGANIC ACID

O H 3 O 1 1 A. O 1 1 OH (K w

# 12 ph-titration of Strong Acids with Strong Bases

The Determination of an Equilibrium Constant

aa + bb cc + dd Equation 1

Acid-Base ph Titration Introduction

Experiment 7 Buffer Capacity & Buffer Preparation

Acid / Base Titrations

Chemical Equilibrium: Finding a Constant, Kc

Kinetics of Crystal Violet Bleaching

Acidity of Beverages Lab

Objectives. Materials TI-73 CBL 2 TM

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution and the analysis of antacid tablets

Chemistry Determination of Mixed Acids

Upset Tummy? MOM to the Rescue! LeChâtelier s Principle

for a Weak Acid 1-ring stand stir plate and stir bar ph Probe ml burette 1-50 ml and ml beaker Drop counter ph 7.00 buffer 0.

Related concepts Electrolyte, electrical conductance, specific conductance, ion mobility, ion conductivity, conductometry, volumetry.

HEATS OF REACTION EXPERIMENT

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

Introduction. Objectives

2 (aq) [FeSCN [Fe 3JSCN] Figure 1

Chemical Equilibrium: Finding a Constant, Kc

Lifetime Measurement

Evaluation copy. Ground Temperature Measurements. computer OBJECTIVES MATERIALS PRE-LAB QUESTIONS

Transcription:

Microscale Acid-Base Titration Experiment 36 A titration is a process used to determine the volume of a solution needed to react with a given amount of another substance. In this experiment, you will titrate hydrochloric acid solution, HCl, with a basic sodium hydroxide solution, NaOH. The concentration of the NaOH solution is given and you will determine the unknown concentration of the HCl. Hydrogen ions from the HCl react with hydroxide ions from the NaOH in a one-to-one ratio to produce water in the overall reaction: H + (aq) + Cl (aq) + Na + (aq) +OH (aq) H 2 O(l) + Na + (aq) + Cl (aq) When HCl solution is titrated with NaOH solution, the ph value of the acidic solution is initially low. As base is added, the change in ph is quite gradual until close to the equivalence point, when equimolar amounts of acid and base have been mixed. Near the equivalence point, the ph increases very rapidly. The change in ph then becomes more gradual again, before leveling off with the addition of excess base. Since this experiment may be your introduction to acid-base titrations, you will determine only the approximate concentration of the hydrochloric acid solution. Use the formula: M acid = M base X V base V acid where M acid is the concentration of the acid (in M or mol/l), M base is the concentration of the base, V base is the volume of the base (in drops), and V acid is the volume of the acid. The concentration of the sodium hydroxide solution is 0.10 M. The drops of sodium hydroxide and hydrochloric acid solutions at the equivalence point will be determined from the experiment. MATERIALS LabPro or CBL 2 interface 0.10 M NaOH solution (in dropper bottle) TI Graphing Calculator HCl solution (in a dropper bottle) DataMate program ph Sensor ring stand utility clamp wash bottle phenolphthalein indicator distilled water micro-beaker (top half of a storage bottle toothpick (for stirring) for the ph Sensor) PROCEDURE 1. Obtain and wear goggles. 2. Prepare the ph Sensor for data collection. a. Plug the ph Sensor into Channel 1 of the LabPro or CBL 2 interface. Use the link cable to connect the TI Graphing Calculator to the interface. Firmly press in the cable ends. b. Remove the ph Sensor from the ph storage solution bottle by unscrewing the lid. Carefully slide the lid from the sensor body. c. Rinse the tip of the sensor with distilled water. Chemistry with Calculators Vernier Software & Technology 36-1

Experiment 36 d. Obtain a ph Sensor storage bottle that has been cut in half. This is your microbeaker! e. With the open end of the ph Sensor pointing upward, as shown here, slip the microbeaker and cap down onto the sensor body (small opening first), so the sensor tip extends about 1 cm into the bowl of the microbeaker. Then tighten the threads of the cap so the cap tightens snugly against the ph Sensor body. f. Attach the utility clamp to a ring stand and to the bottle lid, with the sensor in an inverted position as shown here. 3. Obtain a dropper bottle containing the HCl solution of unknown concentration. Add 10 drops of the HCl solution into the micro-beaker. As you add the drops, hold the bottle in a vertical position to ensure that drop size is uniform. CAUTION: Handle the hydrochloric acid with care. It can cause painful burns if it comes in contact with the skin. Add 1 drop of phenolphthalein indicator to the microbeaker, then add enough distilled water so the resulting solution completely covers the sensor tip. Stir the solution thoroughly with the toothpick. 4. Obtain a dropper bottle containing 0.10 M NaOH. Wait until Step 8 to begin adding this solution to the HCl solution in the microbeaker. 5. Turn on the calculator and start the DATAMATE program. Press CLEAR to reset the program. 6. Set up the calculator and interface for the ph Sensor. a. Select SETUP from the main screen. b. If CH 1 displays PH, proceed directly to Step 7. If it does not, continue with this step to set up your sensor manually. c. Press ENTER to select CH 1. d. Select PH from the SELECT SENSOR menu. 7. Set up the data-collection mode. a. To select MODE, press once and press ENTER. b. Select EVENTS WITH ENTRY from the SELECT MODE menu. c. Select OK to return to the main screen. 8. You are now ready to perform the titration. This process goes faster if one person adds drops of NaOH solution while another person operates the calculator and enters volumes. a. Select START to begin data collection. b. Before you have added any drops of NaOH solution, press ENTER and type in 0 as the NaOH volume, in drops. Press ENTER to save the first data pair for this experiment. c. Add one drop of NaOH solution. Be sure to hold the dropper bottle vertically to ensure that the drop size is uniform. CAUTION: Sodium hydroxide solution is caustic. Avoid spilling it on your skin or clothing. Stir with a toothpick to uniformly mix the solution. When the ph stabilizes, press ENTER and enter 1 as the number of drops of NaOH solution added. You have now saved the second data pair for the experiment. d. Add a second drop of NaOH solution and stir. When the ph stabilizes, press ENTER, and enter 2 as the number of drops added. e. Continue this procedure until 20 drops of NaOH solution have been added. 36-2 Vernier Software & Technology Chemistry with Calculators

Microscale Acid-Base Titration 9. Press STO when you have finished collecting data. 10. Examine the data on the displayed graph to find the equivalence point that is, the 1-drop volume increment that resulted in the largest increase in ph. As you move the cursor right or left on the displayed graph, the volume (X) and ph (Y) values of each data point are displayed below the graph. Go to the region of the graph with the large increase in ph. Find the NaOH volume (in drops) just before this jump. Record this value in the data table. Then record the NaOH volume after the drop producing the largest ph increase was added. 11. (optional) Print a copy of the graph of ph vs. volume. 12. Carefully loosen the ph Sensor from the utility clamp and dispose of the beaker contents as directed by your instructor. Thoroughly rinse out the microbeaker and the ph Sensor tip. Remove the microbeaker from the sensor. Rinse the sensor tip with distilled water and return it to the ph Sensor storage bottle. PROCESSING THE DATA 1. Use your printed graph to confirm the volume of NaOH titrant you recorded before and after the largest increase in ph values upon the addition of 1 drop of NaOH solution. 2. Determine the volume of NaOH added at the equivalence point. To do this, add the two NaOH values determined above and divide by two (use 0.5-drop increments in your answer). 3. Using the formula in the introduction of the experiment, calculate the concentration of the hydrochloric acid solution (in M or mol/l). DATA AND CALULATIONS TABLE Concentration of NaOH NaOH volume added before the largest ph increase NaOH volume added after the largest ph increase M drops drops Volume of NaOH added at equivalence point Concentration of HCl drops M Chemistry with Calculators Vernier Software & Technology 36-3

Vernier Software & Technology

Experiment 36 TEACHER INFORMATION Microscale Acid-Base Titration 1. This experiment can be done prior to Experiment 24, Acid-Base Titration. Students will quickly discover the shape of an acid-base titration curve for the reaction between a strong acid and strong base. They should not expect to determine precise concentration values using this method. It is meant to be an introduction to a traditional acid-base titration, not a substitute for more precise methods. 2. The preparation of 0.10 M NaOH requires 4.0 g of NaOH per liter of solution. Since the equivalence point concentrations are only approximate, using a value of ~0.10 M works well for this experiment. HAZARD ALERT: Corrosive solid; skin burns are possible; much heat evolves when added to water; very dangerous to eyes; wear face and eye protection when using this substance. Wear gloves. Hazard Code: B Hazardous. 3. Unknown samples with HCl concentrations in the 0.080 to 0.100 M range work well. The preparation of 0.080 M HCl requires 6.7 ml of concentrated HCl per liter of solution. HCl that is 0.100 M requires 8.4 ml of concentrated reagent per liter. HAZARD ALERT: Highly toxic by ingestion or inhalation; severely corrosive to skin and eyes. Hazard Code: A Extremely hazardous. The hazard information reference is: Flinn Scientific, Inc., Chemical & Biological Catalog/Reference Manual, 2000, P.O. Box 219, Batavia, IL 60510. See Appendix F of this book, Chemistry with Calculators, for more information. 4. The HCl and NaOH solutions can be dispensed from microscale Beral pipets if you do not have dropper bottles. 5. An alternate way of determining the precise equivalence point of the titration is to take the second derivative of the ph-volume data. When DataMate is transferred to the calculator, a small program called PHDERIVS will be copied into calculator as well. 1 PHDERIVS allows you to view first and second derivative plots of ph-volume data. PHDERIVS is set up to analyze volume data in L1 and ph data in L2. To run the program, follow this procedure: a. After you have collected ph-volume data, leave DataMate by selecting QUIT from the main screen. b. Start the PHDERIVS program. Note: On a TI-83 Plus, PHDERIVS will be a loaded as a program (press PRGM, not APPS ). On a TI- 86, 89, 92, or 92 Plus, the PHDERIVS program will be listed alphabetically below the DATAMATE programs. c. Proceed to the GRAPHS menu. Select SECOND DERIV, a plot of 2 ph/ vol 2. d. Using the arrow keys, move the cursor to the equivalence point. This will be the point where the curve crosses the zero line. The x-value shown at the bottom of the screen is the volume of acid at the equivalence point. 1 PHDERIVS will not be loaded onto the TI-82, TI-83, and TI-73 calculators because of their memory capabilities. If you would like a copy of PHDERIVS for these calculators, visit our web site: www.vernier.com/cbl/progs.html Chemistry with Calculators Vernier Software & Technology 36-1 T

Experiment 36 6. The stored Vernier ph calibration will work fine for this experiment. 7. You can purchase additional ph storage solution bottles from Vernier Software to use as the microbeakers. Simply cut the bottles in half to use in this experiment. Distribute the half with the threaded opening to student lab stations. You do not need to include the cap, since students are instructed to use the cap and O-ring already on the probe). Order information is: ph Storage Solution Bottles pkg of 5 order code: BTL $10.00 8. Explain to your students the purpose of adding the phenolphthalein indicator. They can easily observe the color change and large ph increase occur simultaneously in this experiment. SAMPLE RESULTS Concentration of NaOH NaOH volume added before largest ph increase NaOH volume added after largest ph increase 0.10 M 10 drops 11 drops Volume of NaOH added at equivalence point 10 + 11 2 = 10.5 drops Concentration of HCl = 0.10 M X 10.5 drops 10 drops = ~0.105 M Microscale titration for sodium hydroxide and hydrochloric acid 36-2 T Vernier Software & Technology Chemistry with Calculators

Using the CD Appendix A Important: You do not need to use the CD included with this book unless you want to change something in the student instructions to meet your needs. The CD located inside the back cover of this book contains two folders: Chemistry w Calculators Word - For use with this book. Supports the DataMate calculator program with LabPro or CBL 2. Contains files for each of the 36 student experiments in this book. Chemistry w Computers Word - Not for use with this book. Supports Logger Pro computer software with LabPro, Serial Box Interface, or ULI. Contains files for 31 student experiments in the lab book, Chemistry with Computers. Using the Chemistry with Calculators Word-Processing Files Start Microsoft Word, then open the file of your choice from the Chemistry with Calculators Word folder. Files can be opened directly from the CD or copied onto your hard drive first. These files can be used with any version of Microsoft Word that is Version 6 or newer. All file names begin with the experiment number, followed by an abbreviation of the title; e.g., 01 Endo- Exothermic is the file name used for Experiment 1, Endothermic and Exothermic Reactions. This provides a way for you to edit the tests to match your lab situation, your equipment, or your style of teaching. The files contain all figures, text, and tables in the same format as printed in Chemistry with Calculators. Chemistry with Calculators Vernier Software & Technology A - 1