The Decomposition of Hydrogen Peroxide. Evaluation copy

Similar documents
Evaluation copy. The Molar Mass of a Volatile Liquid. computer OBJECTIVES MATERIALS

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Acid Rain. Evaluation copy

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Acid-Base Titration. Evaluation copy

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

Chemical Equilibrium: Finding a Constant, Kc

Heat of Combustion: Magnesium. This equation can be obtained by combining equations (1), (2), and (3): (1) MgO(s) + 2 HCl(aq) MgCl 2 (aq) + H 2 O(l)

Evaluation copy. Acids and Bases. computer OBJECTIVES MATERIALS

MODULE Catalysis, Chemical Reactions, and Nanoparticles-An Instructional Module

Diffusion through Membranes. Evaluation copy. dialysis tubing, 2.5 cm 12 cm

Photosynthesis and Respiration. Evaluation copy

Evaluation copy. Ground Temperature Measurements. computer OBJECTIVES MATERIALS PRE-LAB QUESTIONS

Evaluation copy. Transpiration. Computer OBJECTIVES

Exploring the Poles (Without Leaving Your Classroom!)

Acid-Base Titration. Computer OBJECTIVES

The Magnetic Field of a Permanent Magnet. Evaluation copy

Transpiration. Evaluation copy

Distance From the Sun

Evaluation copy. Momentum: A Crash Lesson. computer OBJECTIVES MATERIALS

The Determination of an Equilibrium Constant

Determining the Concentration of a Solution: Beer s Law

Establishing a Table of Reduction Potentials: Micro-Voltaic Cells. Evaluation copy

The Synthesis and Analysis of Aspirin

The Determination of an Equilibrium Constant

Cart on a Ramp. Evaluation Copy. Figure 1. Vernier Dynamics Track. Motion Detector Bracket

Ashes to Ashes: Using evaporation rate to identify an unknown liquid

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

Evaluation copy. First-Class Levers. computer OBJECTIVES MATERIALS

Computer 3. Lifetime Measurement

Acid-Base Titration. Sample

Energy of a Tossed Ball. Evaluation Copy. Motion Detector. Figure 1. volleyball, basketball, or other similar

Enzyme Catalysis Lab

H 2 CO 3 (aq) HNO 2 (aq) + HNO 3 (aq)

Determining the K sp of Calcium Hydroxide

The Determination of an Equilibrium Constant

2 (aq) [FeSCN [Fe 3JSCN] Figure 1

Spectrometer User s Guide

How Can We Determine the Actual Percentage of H 2 O 2 in a Drugstore Bottle of Hydrogen Peroxide?

Center of Mass. Evaluation copy

LABORATORY 2. ENZYME CATALYSIS

Lab Activity 3: Factors Affecting Reaction Rate

IODINE CLOCK REACTION KINETICS

LAB. FACTORS INFLUENCING ENZYME ACTIVITY

Determining the Enthalpy of a Chemical Reaction

Chemistry with Mr. Faucher. Acid-Base Titration

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

Microscale Acid-Base Titration

Experimental Procedure Lab 402

The Determination of an Equilibrium Constant

LABORATORY INVESTIGATION

Newton s Third Law. Evaluation copy

Energy Storage and Transfer: Gravitational Energy. Evaluation copy. Vernier Photogate (Extension only)

Microscale Acid-Base Titration

Examining the Effect of Temperature on Reaction Rate

Using Conductivity to Find an Equivalence Point

Determining the Concentration of a Solution: Beer s Law

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Chemical Equilibrium: Finding a Constant, Kc

DIFFUSION THROUGH MEMBRANES STANDARDS B C.4 INTRODUCTION

Investigating Food Dyes in Sports Beverages. Sample

Conductometric Titration & Gravimetric Determination of a Precipitate

Experiment 14 It s Snow Big Deal

PRELIMINARY ACTIVITY FOR. Seasons and Angle of Insolation

Experiment 2: Analysis of Commercial Bleach Solutions

Determination of the Rate of a Reaction, Its Order, and Its Activation Energy

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

STOICHIOMETRY AND THE CHEMICAL REACTION

Chemistry 1B Experiment 17 89

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

The CCLI Initiative Computers in Chemistry Laboratory Instruction

Conductimetric Titration and Gravimetric Determination of a Precipitate

Experiment 7 Can You Slow It Down?

Finding the Constant K c 4/21/15 Maya Parks Partners: Ben Seufert, Caleb Shumpert. Abstract:

Acid Rain. Computer OBJECTIVES

Determination of an Equilibrium Constant

A STUDY OF REACTION RATES

Kinetics of an Iodine Clock Reaction Lab_Student Copy

CIE Chemistry A-Level Practicals for Papers 3 and 5

Enzyme Catalysis. Objectives

THE EFFECT OF TEMPERATURE AND CONCENTRATION ON REACTION RATE

Rate of Reaction. Introduction

THE IDENTIFICATION OF A SOLID ORGANIC ACID

Chemical Equilibrium: Finding a Constant, Kc

CHM112 Lab Iodine Clock Reaction Part 2 Grading Rubric

Conductimetric Titration and Gravimetric Determination of a Precipitate

Micro Mole Rockets. Hydrogen and Oxygen Mole Ratio

Weather Stations. Evaluation copy. 9. Post live weather data on the school s web site for students, faculty and community.

THE THERMODYNAMICS OF POTASSIUM NITRATE DISSOLVING IN WATER V010516

Experiment 17 It s A Gas and More!

Dr. White Chem 1B Saddleback College 1. Experiment 15 Thermodynamics of the Solution Process

Measuring Momentum: Using distance moved after impact to estimate velocity

Hess' Law: Calorimetry

Kinetics; A Clock Reaction

Rate Properties of an Iodide Oxidation Reaction

Spring Thing: Newton s Second Law. Evaluation copy

Experiment 2: The Rate of an Iodine Clock Reaction

Evaluation copy 10A. Impulse and Momentum. Experiment INTRODUCTION OBJECTIVES MATERIALS PRE-LAB QUESTIONS

GRIGNARD REACTION Synthesis of Benzoic Acid

The Phase Change Lab: Freezing and Melting of Water

Transcription:

The Decomposition of Hydrogen Peroxide Computer 12 The decomposition of hydrogen peroxide in aqueous solution proceeds very slowly. A bottle of 3% hydrogen peroxide sitting on a grocery store shelf is stable for a long period of time. The decomposition takes place according to the reaction below. 2 H 2 O 2 (aq) 2 H 2 O + O 2 (g) A number of catalysts can be used to speed up this reaction, including potassium iodide, manganese (IV) oxide, and the enzyme catalase. If you conduct the catalyzed decomposition of hydrogen peroxide in a closed vessel, you will be able to determine the reaction rate as a function of the pressure increase in the vessel that is caused by the production of oxygen gas. If you vary the initial molar concentration of the H 2 O 2 solution, the rate law for the reaction can also be determined. Finally, by conducting the reaction at different temperatures, the activation energy, E a, can be calculated. OBJECTIVES In this experiment, you will Conduct the catalyzed decomposition of hydrogen peroxide under various conditions. Calculate the rate constant for the reaction. Determine the rate law expression for the reaction. Calculate the activation energy for the reaction. MATERIALS Vernier computer interface computer Vernier Gas Pressure Sensor thermometer or Temperature Probe one-hole rubber stopper with stem tubing with two Luer-lock connectors solid rubber stopper (#1) distilled water Figure 1 Evaluation copy 3% hydrogen peroxide, H 2 O 2, solution 0.5 M potassium iodide, KI, solution 18 150 mm test tube two 10 ml graduated cylinders graduated plastic Beral pipet 1 liter beaker ~800 ml room temperature water Advanced Chemistry with Vernier 12-1

Computer 12 PRE-LAB EXERCISE The hydrogen peroxide solution that you are using in this experiment is labeled as a 3% solution, mass/volume. However, in order to complete the calculations, the concentration must be in molarity. Calculate the molarity of a 3% mass/volume H 2 O 2 solution ( I, II, and IV) and a 1.5% mass/volume H 2 O 2 solution ( III) and record these values in the table below. Volume H 2 O 2 (ml) [H 2 O 2 ] before mixing Volume KI (ml) [KI] before mixing I 4 1 0.50 M II 4 1 0.25 M III 4 1 0.50 M IV 4 1 0.50 M PROCEDURE I Decompose 3% H 2 O 2 solution with 0.5 M KI solution at ~20 C. 1. Obtain and wear goggles. 2. Prepare the reagents for temperature equilibration. a. Obtain room temperature water to set up a water bath to completely immerse the test tube. Use a thermometer or a Temperature Probe to measure the temperature of the bath. Record this temperature in your data table for s I-III; presume that the water bath temperature remains constant throughout. b. Measure out 4 ml of 3% H 2 O 2 solution into the test tube. Seal the test tube with the solid rubber stopper and place the test tube in the water bath. c. Measure out 2 ml of 0.5 M KI solution in a graduated cylinder. Draw about 1 ml of the KI solution into a graduated Beral pipet. Invert the pipet and immerse the reservoir end of the pipet in the water bath. 3. Connect a Gas Pressure Sensor to Channel 1 of the Vernier computer interface. Connect the interface to the computer using the proper cable. 4. Use the plastic tubing to connect the one-hole rubber stopper to the Gas Pressure Sensor, as shown in Figure 1. About one-half turn of the fittings will secure the tubing tightly. 5. Start the Logger Pro program on your computer. Open the file 12 Peroxide from the Advanced Chemistry with Vernier folder. 6. Prepare to run the reaction and collect pressure data. a. Remove the test tube from the water bath and remove the solid stopper. b. Remove the plastic Beral pipet from the water bath and quickly transfer 1 ml of KI solution into the test tube. Tap or lightly shake the test tube to mix the reagents. c. Seal the test tube with the one-hole stopper connected to the Gas Pressure Sensor. d. Place the test tube back in the water bath. 7. Click to begin data collection. Data will be gathered for three minutes. If necessary, gently hold the test tube so that it stays completely immersed in the water bath. 12-2 Advanced Chemistry with Vernier

The Decomposition of Hydrogen Peroxide 8. When the data collection is complete, carefully remove the stopper from the test tube to relieve the pressure. Dispose of the contents of the test tube as directed. 9. Examine the graph of I. Select a linear region just beyond the initial flat portion of the graph that covers one minute of the reaction. Click the Linear Regression button,, to calculate the best-fit line equation. Record the slope as the initial rate of the reaction in your data table. Store the results from the first trial by choosing Store Latest Run from the Experiment menu. 10. Rinse and clean the test tube for the second trial. II Decompose 3% H 2 O 2 solution with 0.25 M KI solution at ~20 C 11. Measure out 4 ml of 3% H 2 O 2 solution into the test tube. Seal the test tube with the solid rubber stopper and place the test tube in the water bath. 12. Add 1 ml of distilled water to the remaining 1 ml of KI solution in the graduated cylinder. Swirl the mixture gently to mix the solution. 13. Draw 1 ml of the KI solution into a plastic Beral pipet. Invert the pipet and immerse the reservoir end of the pipet in the water bath. Allow both the test tube and the Beral pipet to remain in the water bath for at least two minutes before proceeding. 14. Repeat Steps 6 10 to complete II. Remember to store the data. III Decompose 1.5% H 2 O 2 solution with 0.5 M KI solution at ~20 C 15. Prepare a 1.5% H 2 O 2 solution by mixing 2 ml of distilled water with 2 ml of 3% H 2 O 2 solution. Transfer the resulting 4 ml of the 1.5% H 2 O 2 solution to the test tube, seal the test tube with the solid stopper, and place the test tube in the water bath. 16. Rinse and clean the graduated cylinder that you have used for the KI solution. Add a fresh 2 ml of 0.5 M KI solution to the graduated cylinder. 17. Draw 1 ml of the KI solution into a plastic Beral pipet. Invert the pipet and immerse the reservoir end of the pipet in the water bath. Allow both the test tube and the Beral pipet to remain in the water bath for at least two minutes before proceeding. 18. Repeat Steps 6 10 to complete III, and store the data. IV Decompose 3% H 2 O 2 solution with 0.5 M KI solution at ~30 C 19. Conduct IV identically to the procedure in I, with one exception: set the water bath at 30 C. Advanced Chemistry with Vernier 12-3

Computer 12 DATA TABLE Reactants Temperature ( C) Initial rate (kpa/s) I 4 ml 3.0% H 2 O 2 + 1 ml 0.5 M KI II 4 ml 3.0% H 2 O 2 + 1 ml 0.25 M KI III 4 ml 1.5% H 2 O 2 + 1 ml 0.5 M KI IV 4 ml 3.0% H 2 O 2 + 1 ml 0.5 M KI DATA ANALYSIS Initial rate (mol/l-s) [H 2 O 2 ] after mixing [I ] after mixing Rate constant k I II III IV 1. Calculate the rate constant, k, and write the rate law expression for the catalyzed decomposition of hydrogen peroxide. Explain how you determined the order of the reaction in H 2 O 2 and KI. 2. The following mechanism has been proposed for this reaction: H 2 O 2 + I IO H 2 O H 2 O 2 + IO I + H 2 O + O 2 If this mechanism is correct, which step must be the rate-determining step? Explain. 3. Use the Arrhenius equation (shown below) to determine the activation energy, E a, for this reaction. ln k 2 E 1 = R T2 T1 k1 a 1 12-4 Advanced Chemistry with Vernier

Vernier Lab Safety Instructions Disclaimer THIS IS AN EVALUATION COPY OF THE VERNIER STUDENT LAB. This copy does not include: Safety information Essential instructor background information Directions for preparing solutions Important tips for successfully doing these labs The complete Advanced Chemistry with Vernier lab manual includes 35 labs and essential teacher information. The full lab book is available for purchase at: http://www.vernier.com/cmat/chema.html Vernier Software & Technology 13979 S.W. Millikan Way Beaverton, OR 97005-2886 Toll Free (888) 837-6437 (503) 277-2299 FAX (503) 277-2440 info@vernier.com www.vernier.com