Introduction to IH Analytical Chemistry

Similar documents
METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003

Real-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)

HYDROCARBONS, AROMATIC 1501

METHYLTIN CHLORIDES 5526

ORGANOPHOSPHORUS PESTICIDES 5600

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority:

Chromatography. Gas Chromatography

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Industrial Hygiene Report

Validation of. Tetrahydrofuran Using. SKC Passive Sampler Cat. No

VINYL CHLORIDE. Recommended by NIOSH, partially evaluated by OSHA Laboratory.

Chapter 31 Gas Chromatography. Carrier Gas System

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Media blank result for a single-section sampler (e.g., membrane filter). Media blank result for back section of a sampler.

CHAPTER 6 GAS CHROMATOGRAPHY

Principles of Gas- Chromatography (GC)

High Performance Liquid Chromatography

Laboratory Safety and Fundamental Equipment Post-Assessment Exam Page 1 of 9

Research Report. Validation of Methyl Methacrylate (MMA) using SKC Passive Sampler Abstract

University of Tennessee Safety Procedure

Chromatography & instrumentation in Organic Chemistry

Art, Science or Voodoo?

Hazard Communication PPT-SM-HAZCOM V.A.0.0

Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs

Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14)

Module No. # 02 Lecture No. # 06 Dispersion models (continued)

IV. DIRECT MEASUREMENT LABS. Introduction

Sample Date (Required) IH UIC (Required) The date the sample is collected.

Sample Date (Required) IH UIC (Required) The date the sample is collected.

Short-Period Air Sampling by Direct-reading Instruments

Gas Chromatography notes

GAS CHROMATOGRAPHY (GC)

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES

HAZARD COMMUNICATION PROGRAM

The Lab-Field Gap between IH Chemists and IH Non- Chemists - A Chemist's View. C.R. (Gus) Manning

Methods of pollution control and waste management - laboratory. Adsorptive removal of volatile organic compounds from gases streams

Physical Separations and Chromatography

CHROMATOGRAPHY AND MASS SPECTROMETER

Common Safety Data Sheet Terms

INDUSTRIAL HYGIENE DIRECT READING SINGLE STRESSOR SAMPLE SURVEY FORM

Chemistry Gas Chromatography: Separation of Volatile Organics

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Irene L. Richardson, M.S.

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Technical know-how in thermal analysis measurement

Introduction. 1. Safety and chemical exposure

Gas Chromatography. Introduction

Introduction to Gas Chromatography

Hazard Communication Program

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Safety Data Sheets (SDS)

Gas Chromatography (GC)

Hazcom 2012: Changes to the OSHA Hazard Communication Standard. Risk Engineering

Raw Material Finished product By product Exposure standards Length of shift Physical environment

3590/ Laboratory

Method for the determination of 1,3-butadiene

This document is a preview generated by EVS

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

RADIATION SAFETY GUIDELINES FOR NON-USERS

Questions, Myths and Misconceptions about Using Photoionization Detectors

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

HYDROGEN CYANIDE 6017

PRESENTER'S GUIDE "HAZMAT LABELING" Training for the OSHA HAZARDOUS WASTE OPERATIONS and EMERGENCY RESPONSE (HAZWOPER) REGULATION

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

C L I E N T A LERT. Ha r m o n i z i n g Ha z a rd Co m m u n i c a t i o n : OSHA Pr o p o s e s t o. I. Ba c k g r o u n d

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

FORMALDEHYDE by GC 2541

MEASURING NANOPARTICLE EXPOSURE

Chapter content. Reference

DEHYDRATION OF ALCOHOLS-GAS CHROMATOGRAPHY

1. The Supervisor and/or the Section Safety Officer must be notified of all accidents and injuries which may occur within the section.

METHOTREXATE mg/m 3 (arbitrary). There is no OSHA PEL or AGGIH TLV for

Paper Chromatography. Identifying the components of a mixture

Determination of Volatile Substances Proof of Food Adulteration

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Material Safety Data Sheet acc. to ISO 11014

HAZARD COMMUNICATION PROGRAM

1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer. HAZARDS IDENTIFICATION Classification of the Substance or Mixture

Application Note 032

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Dehydration of Alcohols-Gas Chromatography

NANOTECHNOLOGY: AN INDUSTRIAL HYGIENE PERSPECTIVE. Loren Anderson, CIH, ROH

Instrumental Chemical Analysis

ENVH 555. Industrial Hygiene Methods: Laboratory

G a s C h r o m a t o g r a p h y Determination of Ethanol in Wine by Head-Space Gas Chromatography

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

PILOT OF AN EXTERNAL QUALITY ASSURANCE PROGRAMME FOR CRYSTALLINE SILICA

Arizona Division of Occupational Safety and Health Administration. 800 W. Washington Street, Phoenix, AZ Consultation:

Gas Chromatography-Mass Spectrometry (GC-MS)

MATH 1050QC Mathematical Modeling in the Environment

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Experience with data handling in large chemical databases NEAL LANGERMAN

Good Stewardship and Safe Nanomaterial Handling Practices for Graphene Products

Gas Chromatography. 1. Experiment Category: 2. Experiment Name: 3. Date and Issue number: 4. Instructor Name: 5. Institution: Ain Shams University

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Transcription:

Introduction to IH Analytical Chemistry Sampling and Analysis Manning, Eide, Van Etten (Apr 2013)

Foreword Thank you for purchasing the Introduction to IH Analytical Chemistry self-study workbook. Course Format The workbook is divided into 9 chapters, each with review questions. Read through each of these chapters and take the time to answer the review questions at the end. You can type your answers in the document. Answers to the review questions are included at the back of the workbook so you can check your work. Final Exam & Evaluation The final exam will test your knowledge of the materials you have studied. The final exam should be taken by yourself, working alone, but you may consult tables, graphs, charts, calculator, manuals, course materials and other references as the need arises. Exam Evaluation Once completed, you will receive notification of your updated Education Transcript with CM, COC and CEU credit for this course. Scoring Final Exam scoring is as follows: 90-100% Excellent 80-89% Good 70-79% Fair <70% Exam must be retaken Retaking the Final If you fail to achieve 70% on your first try, you may retake the Final Exam after re-reviewing and re-studying course materials. If you fail to score 70% on the second test, you will not be awarded CM, CEU or COC credit. Course Credit The course will award 6.0 CM credit/contact hours, 0.6 CEU and 0.6 COC. Completion Time You have 3 months from the date of purchase to complete the course and exam. If more time is needed please contact the AIHA elearning Program Assistant at dlassistant@aiha.org. 02

Table of Contents 1. Definitions...2 2. Occupational Exposure Limits PELs and STELs...5 3. Personal Sampling (in Workers Personal Breathing Zones)...8 4. Sampling Gases, Vapors, and Aerosols... 10 5. Characteristics of Personal Samplers... 13 6. Personal Sampling Parameters and Calculations... 17 7. Lab Analysis Basic Concepts... 22 8. Lab Analysis Techniques... 26 9. Data Analysis and Statistics... 36 10. Answer Key for Review Questions... 40 1

1. DEFINITIONS Air Sample The contents of a sampler which has been used in an air sampling event American Conference of Governmental Industrial Hygienists (ACGIH ) A private organization that has established guidelines and Occupational Exposure Limits to promote chemical safety. Analyte or Contaminant The chemical substance that is being sampled and analyzed. Certified Industrial Hygienist (CIH) An IH practitioner certified by the American Board of Industrial Hygiene (ABIH) based on meeting work experience requirements, and passing a comprehensive examination. IH Practitioner An industrial (occupational) hygienist who identifies, measures, and controls exposures in a workplace, and conducts exposure assessments, including conducting air sampling events. IH Industrial hygiene or occupational hygiene, a profession that identifies, measures, and controls exposures in a workplace. IH Lab An AIHA -accredited Industrial Hygiene Laboratory (AIHA Registry Programs LLC) that analyzes Samples National Institute for Occupational Safety and Health (NIOSH) An agency of the US government (in the Department of Health and Human Services) charged with doing research and making recommendations in support of the Occupational Safety and Health Act of 1970. NIOSH publishes the NMAM (NIOSH Manual of Analytical Methods) which describes non-binding OELs and sampling methods used by NIOSH in doing their research studies in occupational exposure. Occupational Exposure Limit (OEL) A generic name for any exposure limit established by any organization to control TWA exposures to workers. Occupational Safety and Health Administration (OSHA) An agency of the U.S. government charged with enforcing the Occupational Safety and Health Act of 1970. OSHA establishes PELs (below) that are legally binding regulations under the OSH Act. OSHA also publishes OSHA Sampling and Analytical Methods (OSAM) that it uses for sampling events in enforcement inspections. OSAM are recommended, but are not legally binding (as the agency desires to support the development of new and improved methods that may be more suitable for the private sector.) 2

5. CHARACTERISTICS of PERSONAL SAMPLERS Sampling Tubes Used for sampling gases and vapors, sampling tubes are glass ampoules usually containing two sections of loosely packed sorbent particles separated by an inert spacer. Sorbents for different sampling tubes are selected based on chemical affinity for analytes to be sampled. To begin sampling, each tube is broken at both ends, then attached via tubing to a sampling pump which draws air though the tube at a metered sampling rate (ca. 100 ml/min). The open end of the sampling tube is attached near the worker s lapel, while a sampling pump is attached at the worker s belt. Air passes through the larger (front) sorbent section first, and, then, subsequently, through the smaller (back-up) section of the tube. The two sorbent sections are analyzed separately by the lab. The finding of a significant amount of analyte in the back section of sorbent indicates breakthrough of analyte through the sorbent and suggests an invalid sample. Different organizations may have different guidelines as to how much back-section analyte (as % of total sample) is grounds for rejecting a sample. (As a rule of thumb, 10% of analyte in the back-section suggests at least 1% has been lost from the back section, while 20% in the back-section suggests at least 4% has been lost.) Sampling Cassettes Sampling cassettes are used in sampling of aerosols (solid or liquid particles) as they retain analytes by mechanical entrapment rather than by chemical affinity. Like sampling tubes, cassettes are used in conjunction with a 1-lb sampling pump that draws air through tubing connected to the cassette (typical sampling rates 1 2 L/min). Each cassette contains a porous filter disc that is matched to the size of the particles to be collected. For analysis, the cassette is disassembled and the filter disc removed for examination and extraction. In some cases, the entire cassette is extracted to remove particles adhered to the cassette body. 2 piece cassettes are used for closed face sampling methods. 3 piece cassettes are used when open face sampling is required. Some so-called treated sampling cassettes contain filters treated with chemical reagents which form a stable derivative when exposed to a reactive vapor or aerosol. It is important to recognize that treated cassettes are able to sample for vapors or aerosols that are reactive with the treating reagent, while un-treated cassettes are unable to retain gases or vapors at all. 13

6. PERSONAL SAMPLING PARAMETERS and CALCULATIONS Calculating Time-Weighted Average (TWA) Concentrations In normal IH practice, air samples are collected in the field and the sampler is shipped to a remote IH lab that analyzes the sampler. In so doing, the IH lab extracts and measures the quantity (mass) of analyte found in the sampler. The average air concentration of chemical present in the worker s breathing zone can be determined as the amount of analyte found in the sampler divided by the volume of air sampled, as follows. TWA Conc n = [Amount Found (µg)] / [Sample Volume (L) ] Sample Volume The effective volume of air sampled during an air sampling event is equal to the sampling time (typ., minutes) multiplied by the sampling rate (typ., ml/min). Assuming typical units are employed the calculation of sample volume is as follows. [Sampling Time (min)] X [Sampling Rate (ml/min)] = Sample Volume (ml) [Sample Volume (ml)] X [L/1000 ml] = Sample Volume (L) Different time units (seconds, minutes, hours), Rate (ml/min, L/hr, etc.), and volume (ml, L, M 3 ) may also be used, as long as the units of time and rate are properly matched for the calculation. When sampling with badges it is also important for the IH to record the temperature and uncorrected barometric pressure or elevation of the worksite. It is important to note that the sample volume has as much impact on the calculated result as the mass of analyte found by the lab. Thus, any error in measuring the sample volume is as costly as an error in lab analysis. Sampling Rate and Sample Volume Sampling devices used by the IH in the field are characterized by their sampling rate (ml/min). Some sampling devices (sampling pumps) can be adjusted in the field to a desired sampling rate, while others (personal monitoring badges) have a fixed sampling rate for each chemical sampled. The sampling rate for a particular analyte on a particular badge is obtained from its manufacturer. 17

8. LAB ANALYSIS TECHNIQUES Some of the fundamentals of the analytical methods most commonly employed in industrial hygiene analysis are included in the following section. Gas Chromatography (GC) The most popular single technique in industrial hygiene analysis, gas chromatography is specified for the analysis of more than 150 analytes in OSHA methods, the NIOSH Manual, and in the standard test methods of many accredited industrial hygiene labs. In gas chromatography, a sample (usually a solvent containing analytes) is injected into a flowing gas stream (helium or hydrogen) which immediately passes through a heated column containing a polymer material (or sorbent). During chromatography, each analyte tends to travel through the column at a slightly different rate (based on its affinity for the column material) emerging from the column at a different time (the retention time). In gas chromatography, the column is often programmed to increase in temperature at a pre-determined rate, taking advantage of the fact that each analyte s affinity for the column is altered dramatically as its boiling point in approached. In so-called temperature programmed GC, analytes travel very slowly down the column at temperatures below their boiling point, and begin to travel very rapidly when their boiling point is approached. Scanning the column temperature in this way provides a method for analyzing a large number of analytes in a small amount of time. Sample injector Flow controller Waste Column Detector Carrier gas Column oven FIGURE 1. A schematic of a gas chromatograph 26

REVIEW QUESTIONS Section 8. Lab Analysis Techniques 1. What is the most commonly used Lab analysis method for organic vapors? Why? 2. Analytes are separated in gas chromatography based on which of the following physical properties? (a) Affinity for the GC column stationary phase (b) Number of carbon atoms (c) Heat of vaporization (d) Volatility (vapor pressure & boiling point) (e) Specific gravity 3. What is the most commonly used lab analysis method for metal dust? Why? 4. What class of compounds is best suited for HPLC? 5. The detector commonly used for gas chromatographic analysis of carbon containing analytes is: (a) Electron capture detector (b) Flame ionization detector (c) Electron capture detector (d) Flame photometric detector 34

Answer Key for Questions Section 1. Definitions: 1. What is an IH practitioner? What is a CIH? An IH is anyone who practices industrial hygiene, regardless of credentials. A CIH is a Certified Industrial Hygienist, i.e., one whose professional standing has been recognized by the American Board of Industrial Hygiene (ABIH), based on a review of qualifications, passing of a comprehensive exam, and meeting maintenance requirements. 2. What is the difference between a STEL and a Full-Shift PEL? A STEL is a PEL for short-term exposure, a 15-min TWA. A full-shift PEL is a PEL for the duration of the work shift, usually a 8-hr TWA. 3. Which of the following Occupational Exposure Limits are legally enforceable? (a) OSHA PEL (b) ACGIH TLV (c) NIOSH REL (a) OSHA PEL 4. Which of the following performs accreditation of industrial hygiene laboratories? (a) NIOSH (b) OSHA (c) AIHA (d) EPA (c) AIHA 5. What organization enforces the Occupational Safety and Health Act of 1970? OSHA 6. Which of the following organizations performs certification of industrial hygienists? (a) NIOSH (b) OSHA (c) ABIH (d) ACGIH The American Board of Industrial Hygiene (ABIH). 40