Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs

Similar documents
Preparative Separation of Active Components from Natural Products using Low-pressure Gradient Preparative HPLC

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Screening of pesticides in water using SPE on line

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

Development of high speed CYP cocktail inhibition assay using UHPLC-MS/MS

Highly sensitive quantitative analysis of Felodipine and Hydrochlorothiazide from plasma using LC/MS/MS

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

COMPREHENSIVE LC X LC ANALYSIS OF FLAVORING INGREDIENTS IN DISTILLED SPIRITS

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (2015) by GPC-GC-MS/MS

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

+ butanal + 2-picolineborane. + acetic acid. + butanal + 2-picolineborane. + acetic acid

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Benzodiazepines and Barbiturates

Chiral Separation Using SFC and HPLC

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

State-of-the-art C18 HPLC Columns

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188A

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Shodex TM ODP2 HP series columns

Open Column Chromatography, GC, TLC, and HPLC

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer)

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Micro Volume QuEChERS kit

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Consumables Guide for the Cannabis Testing Lab

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

State - of - the -art C18 HPLC Columns

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

penta-hilic UHPLC COLUMNS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

High Performance Liquid Chromatography

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Nexera UC Unified Chromatography

Determination of Pharmaceuticals in Environmental Samples

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

CHAPTER 19 PARACETAMOL + IBUPROFEN

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Selecting Detectors for Compounds with No Optical Absorbance

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) tandem mass spectrometry

Supporting Information. Corporation, 1-1 Kurosakishiroishi, Yahatanishi-ku, Kitakyushu , Japan

Fast methods for the determination of ibuprofen in drug products

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

A Protocol for High-Throughput Drug Mixture Quantitation: Fast LC MS or Flow Injection Analysis MS?

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

LC Technical Information

Protein Sequencer PPSQ-31A / 33A C297-E055B

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Peptide Isolation Using the Prep 150 LC System

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

It s hot! ZIC -chilic

Hypericin Analysis by LC/MS

penta-hilic UHPLC COLUMNS

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

HPLC Praktikum Skript

with diode array detection

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Appendix II- Bioanalytical Method Development and Validation

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Transcription:

PO-CON1577E Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs HPLC 215 PSB-PHARM-17 Minori Nakashima*(1), Yuki Sato (2,3), Takeshi Kuwahara (3), Azusa Uchida (1), Takenao Fujii (1), Daisuke Nakayama (1), Tadayuki Yamaguchi (1); (1) Analytical & Measuring Instruments Division Shimadzu Corporation, (2) Shimadzu GLC, (3) Department of pharmacy National Cerebral and Cardiovascular Center

Introduction The majority of pharmaceutical drugs are still small molecule drugs. Many of them consist of basic compounds. Although carryover is one of the biggest issues when analyzing basic compounds with HPLC, the recent progress of HPLC system has been overcoming the issue. On the one hand, adsorption onto consumables when in sample preparation is regarded as another big issue. Especially, adsorption onto vials directly decreases the accuracy and the precision of quantitative values. Two main materials of HPLC vial are glass and polypropylene. It is famous that basic compounds adsorb to glass surface and hydrophobic compounds absorb to polypropylene surface, respectively. The adsorption rate elevates at the lower sample concentration. Thus, recent progress of HPLC system on sensitivity emphasize the adsorption effect. To overcome the adsorption effect, we developed and evaluated a novel glass vial LabTotal vial which is highly inert to basic compounds and perfect for highly sensitive LC/MS analyses. Methods Regent and standards Reagents : Standard samples (amitriptyline, atenolol, imipramine and propranolol ) and TFA were purchased from Wako chemical. Water was made in house using a Millipore Milli-Q Integral 5 Ultrapure Water Purification System. Acetonitrile and methanol were purchased from Nacalai tesque. Standard solutions : Stock solutions were prepared by dissolving.1 mg of standard samples in 1 ml of water, respectively. They were diluted in mobile phase before use. Analytical conditions LC System : Nexera MP system (Shimadzu corporation) Detector : SPD-M3A photodiode array detector and LCMS-86 triple quadrupole mass spectrometer Surface analyzer : Nano search microscope SFT-45 (Shimadzu corporation) Table 1 LC and LC/MS/MS Analytical Conditions Column : Shim-pack XR-ODS seris columns (1 mm L. x 2. mm I.D./5 mm L. x 2. mm I.D., 2.2 μm) Mobile Phase : A:.1 % TFA in water; B:.1 % TFA in Acetonitrile 4%B (Amitriptyline, Imipramine), 2%B (Propranolol), 1%B (Atenolol) Flow Rate :.5 ml/min Column Temperature : 4 C Injection Volume : 1 µl Detection : 254 nm (Amitriptyline, Imipramine), 28 nm (Atenolol), 29 nm (Propranolol), 24 nm (Amiodarone), ESI-positive MRM mode (Figure 3) 2

Results Comparison of adsorption of basic compounds The novel glass vial and other vendor s vials were evaluated for adsorption of four basic compounds. The LabTotal vial showed the highest inertness for all compounds. Table 2 Peak area and estimated recovery rate Compound 1 mg/l Amitriptyline 1 mg/l Atenolol 1 mg/l Imipramine 1 mg/l Propranolol 51376 (1%) 8638 (1%) 6499 (1%) 32249 (1%) (for LCMS) 45376 (88 ) 762 (88%) 55531 (85%) 31496 (97%) (for LC/GC) 21788 (42 ) 6137 (71%) 24131 (37%) 27327 (84 ) *Recovery rate was estimated by divided by the peak area of LabTotal vial. 2 Amitriptyline 4 Atenolol 3 1 2 1 1.5 2. 2.5 min 1. 1.5 2. min 3 Imipramine Propranolol 2 2 1 1 1.5 2. 2.5 min..5 1. min Figure 1 Structures and chromatograms of four basic compounds 3

Adsorption effect on ultratrace analysis To evaluate the performance for trace analysis with LC/MS/MS, the LabTotal vial and the vendor A vial (for LC/MS) were tested with.5 µg/l basic compound solution. The LabTotal vial showed about 2 times higher peak area than the vendor A vial. (x1,) 2. 1.5 Area 884 444 1..5..5 1. 1.5 2. 2.5 3. min Fig.3 MRM Chromatogram of.5 μg/l Basic Compound Standard Solution Adsorption effect for the compounds having both basic and hydrophobic properties Amiodarone is a compound having both hydrophobic and basic properties and adsorbs onto both glass and polypropylene vials. The LabTotal vial showed excellent inertness far more than both vials. The data suggested that the LabTotal vial is suit for the compounds which have various properties or unknown property. 3 Area 6216 Amiodarone Polypropylene vial 173 2 glass vial 175 1..5 1. 1.5 2. 2.5 3. min Fig.4 Structure and chromatograms of Amiodarone (1 mg/l) 4

Analysis of glass surface To understand the causes of the higher inertness of the LabTotal vial, its microstructure was compared with vendor B vial. The LabTotal vial has quite smooth surface structure by contrast with vendor B vial having rough structure. Furthermore, by analyzing their nanostructures, hole structures were found on the latter vial. The hole size was reasonable to trap small compounds and then explain the cause of the higher adsorption effect. LSM Height image (3D) LSM Height image (3D) Height: 1 µm Height: 1 µm AFM Height image (3D) AFM Height image (3D) 5. µm 5. µm Height: 1. nm 5. µm Height: 6. nm 5. µm AFM Height image (2D) AFM Height image (2D) B A B 12.65 [nm] 6. [nm] A 5. nm 1. x 1. µm. 2. µm 5. x 5. µm. Shape profile A-B Shape profile A-B Fig.5 Surface analysis of Fig.6 Surface analysis of s Vial 5

Conclusions The LabTotal vial showed the higher inertness for not only basic compound but also the compound having both basic and hydrophobic properties. The LabTotal vial also showed the excellent performance for very low amount of sample. Thus, it is preferable for trace analysis using LC/MS/MS. The smooth micro/nano structure of the LabTotal vial is supporsed to cause its lower adsorption activity. The evaluation results demonstrated that the can be a first choice regardless of the properties of the target compound. Especially, it is quite effective to the unknown samples requiring the highly precise quantitative results and the multicomponent samples having various properties. First Edition: June, 215 www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. Shimadzu Corporation, 215