Product Description and Specification

Similar documents
SYNCHROM EVO III. Choose your application of. Syn. processowner. runtime min. tracer reaction reactor purification. radiochemical.

Agilent G2350A Atomic Emission Detector (AED)

ɣ-radiochromatography

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

ChemComm. Supplementary Information. RSCPublishing

Automation of the radiochemical procedures for the sequential separation of radionuclides

[ 11 C]NNC 112 FOR INJECTION: CHEMISTRY, MANUFACTURING AND CONTROLS

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

[ 18 F]FALLYPRIDE FOR INJECTION: MASTER BATCH RECORD

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

Automatic titrators, TitroMatic

JAPAN QUALITY. Automated Clinical Analyzer

Petrochemical. Transformer Oil Gas Analysis - TOGA

ION CHROMATOGRAPHY SYSTEM S 150

TECHNOLOGY FOR PRODUCTION OF PORTABLE TC-99M GEL GENERATORS USING NEUTRON ACTIVATED NATURAL MOLYBDENUM ALMATY, REPUBLIC OF KAZAKHSTAN

Rapid Catalyst Screening Reactors

iba-synthera.com SYNTHERA + BETTER, SMARTER, STRONGER.

Auto-Immunity & Ease of Use through Automation. The DIAsource Neptune Instrument & Reagents

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

ACCELERATOR MASS SPECTROMETRY AT THE LUND PELLETRON ACCELERATOR

QuantumMCA QuantumNaI QuantumGe QuantumGold

Experiment 9: Synthesis and Isolation of Optical Isomers of a Cobalt (III) Compound CH3500: Inorganic Chemistry, Plymouth State University

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

The sercon group Isotope Ratio Mass

separation of the cleaned extract in subgroups of compounds (PCDDs, PCDFs, PCBs) depending on their polarity and geometry. The fractions can then be a

[ 11 C]MePPEP FOR INJECTION: CHEMISTRY, MANUFACTURING AND CONTROLS

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

High-Performance Continuous Flow Chemistry Systems. Robust Accurate Flexible Safe

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

Mercury Stack Monitor SM-4

High-Pressure Volumetric Analyzer

CapaciTorr HV Pumps. making innovation happen,together

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

MultiVap8: Automated concentration system

BG75 Plus [ 11 C] Upgrade CPM and Target Automated [ 11 C]Acetate Production & QC

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

20-22 ISOTOPE RATIO MASS SPECTROMETER

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Muliple Gas#3 plus Sulfur GC Configuration

SOPHAS - Speeding up the process of discovery and optimisation

In-Solution Digestion: Multi-Plate v1.0 Quick Start Guide

HIPPURIC ACID and o-m-p- METHYLHIPPURIC ACIDS IN URINE BY UV CODE Z06010

FlowSyn The Continuous Flow Reactor from Uniqsis Designed by chemists for chemists

Coflore Agitated Cell Reactor

Varian Galaxie Chromatography Data System for Preparative HPLC

Fusion UV/Persulfate TOC Analyzer

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

2. Pharmaceutical industry

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Thermal Soil Desorber Instructions September 2006

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Determination of freezing points of pure substances with Cobra4 TEC

Computational Chemistry Lab Module: Conformational Analysis of Alkanes

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Fusion UV/Persulfate TOC Analyzer

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Determination of Polymer Modifier in Asphalt

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

To understand concept of limiting reagents. To learn how to do a vacuum filtration. To understand the concept of recrystallization.

H E L P I N G C H E M I S T S. StartSYNTH. Microwave Synthesis Labstation

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

SPECIFIC MONOGRAPH TECHNETIUM ( 99M TC) SUCCIMER INJECTION

TitriSoft 2.5. Content

Automated Clinical Analyzer

novaa 800 D Atomic Absorption Spectrometer

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Finnigan LCQ Advantage MAX

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

COMMITTEE FOR HUMAN MEDICINAL PRODUCTS (CHMP) GUIDELINE ON RADIOPHARMACEUTICALS

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

Continuous flow nanocatalysis: reaction pathways in the conversion of levulinic acid to valuable chemicals

Thermo Finnigan LTQ. Specifications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Karl-Fischer Titration the method for determining water

Focus Series Peptide Synthesizers

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Synthesis of Benzoic Acid

Nano Spectrophotometer LNS-A10

RADIONUCLIDE INFORMATION

and Environmental Science Centre

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

ISEmax CAM40/CAS40. Technical Information

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

1. A gas chromatograph equipped with flame ionization detection and a computing integrator.

ChromTech options for PAL systems

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

FOR RESEARCH USE ONLY.

The New Legend. Eppendorf Reference 2 Pipette

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

Transcription:

Product Description and Specification Catalog No 7 Synthra [ 11 C]Choline Description Synthra [ 11 C]Choline is a completely automated synthesis system for routine production of [ 11 C]choline. Using in-target produced [ 11 C]carbon dioxide, high specific activity preparations are produced ranging from 10 Ci/µmol to 24 Ci/µmol when high purity target gas is used for [ 11 C]CO 2 production. The target gas should meet the following requirements: Cold carbon dioxide (CO 2) content: less than 20 ppb (part per billion) Cold carbon monoxide (CO) content: less than 20 ppb (part per billion) Cold total hydrocarbon (CH n) content: less than 50 ppb (part per billion) First the [ 11 C]carbon dioxide is trapped in a stainless steel tube at -180 C and converted to [ 11 C]methane by reduction on a Ni catalyst. The [ 11 C]methane is trapped at -120 C on a Carbosphere column and the hydrogen is removed from the system. In a successive gas phase reaction the [ 11 C]methane is converted into [ 11 C]methyl iodide and trapped on Porapak Q in a column. Methyl iodide is ready for release after only 7 min starting from trapping the [ 11 C]carbon dioxide. The yield for the [ 11 C]methyl iodide formation is better than 50% non-decay corrected. Up to 15 sequential [ 11 C]methyl iodide preparations are possible from a single box set-up. The [ 11 C]methyl iodide can be used for solid support heterogeneous reactions for the synthesis of [ 11 C]choline in the cartridge oven. The synthesis system is equipped with: 3 reagent vials with dead volume free connections to the valves A built-in detector to determine the activity of the final radiopharmaceutical preparation A liquid nitrogen cooling trap for the collection of radioactive volatiles and for protection of the vacuum pump Cartridge holder for the final purification step A leak detector

The module also contains filter integrity test capability according to GMP. After filtration of the final formulated radiopharmaceutical product, an automated pressure hold test according to GMP is done at the steril filter. The measuring procedure is monitored and graphically documented. The synthesis unit has a chemically inert vacuum pump with end vacuum of < 5 hpa (5 mbar). All wetted components are chemically inert, simplifying maintenance and protecting the final product. A portable PC for controlling the synthesizer with min. 320 GB hard disk drive, 4 GB RAM, CD/DVD reading/writing, 15 screen and LAN port is included. The control hardware is implemented in the synthesizer. The synthesizer is controlled via TCP/IP from the provided notebook. The synthesizer can be operated either fully automated controlled by software using time lists or by manual operation of the automated system. The automated as well as the manual operation is performed via graphical user interface. The synthesizer has program lists for 2 different radiopharmaceuticals already built-in. New sequences or different conditions can be created easily and tested by graphical simulation prior to the operation of the new sequence. The integrated program lists can be used as templates for the creation of new time lists. The synthesizer has a built-in cleaning program. The machine runs with a data logging procedure. All manual or automated operations are separately recorded. The synthesizer provides a synthesis report which includes the preparations steps, the recorded data channels and the yield of the synthesis and the specific activity of the synthesized tracer. The software generates full GLP conform production documentation including data logging capability. The documentation report includes preparation steps, the graphical trending of the up to 18 channels, radioactivity, temperature and pressure, the radiochemical yield and the specific activity of the labeled radiopharmaceutical. The software has built-in functions e. g. for the preparation and printing of production reports. The software is in full compliance with GMP/GLP guidelines.

Features: Simple creation of user-defined synthesis methods Seven heating zones, four with cooling capabilities (-196 C 800 C ) Three electronic flow controllers One leak detector Four shielded radiation detectors for in-process feedback Two (1-3 ml) and three large (10-15 ml) volume glass vials for reagents Chemically inert valves with small dead volume (< 35 µl) 5 bar rated Chemically inert vacuum pump Cooling trap with liquid nitrogen to collect radioactive volatiles compounds The unit as well as the software are easy to set up and operate The synthesizer has program lists for 2 different radiopharmaceuticals Automated cleaning Electronic control and data collection system for up to18 channels embedded cgmp compliance complete logbook for cgmp documentation Control via TCP/IP Password protected access to software Software (Windows 7, SynthraView), computer and mouse included

Synthra [ 11 C]Choline Synthra [ 11 C]Choline graphical user interface

Examples for [ 11 C] compounds [ 11 C]Radiotracer Target Application Choline Choline kinase Tumors, prostate, lung and esophageal cancer Specifications: Yields: > 50 % for [ 11 C]CH 3I in less than 7 min Maximum [ 11 C]CO 2 starting activity 150 GBq Number of consecutive [ 11 C]CH 3I syntheses 15 Synthesis time for [ 11 C]choline 20 min Yield for [ 11 C]choline [RCY] 30 % Radiochemical purity for [ 11 C]choline > 98 % Dimensions 42 cm 45 cm 40 cm (w d h) Weight Approx. 30 Kg Hot Cell (minimum size) 60 cm 50 cm 50 cm (w d h) Utilities Compressed air 4-8 bar 6 mm O.D. Compressed He Purity 6.0 (99.9999 %) 3-5 bar, 1/8 O.D. Compressed H 2 Purity 6.0 (99.9996 %) 3-5 bar, 1/8 O.D. Target gas connection 1/8 O.D. Synthra GmbH reserves the right to modify the information contained herein without prior notice. Copyright 2013 Printed in the EU Rev 1.0