An Investigation of the Impact of Common Experimental Parameters on Signal Intensity in SFC ESI MS

Similar documents
Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

Multi-Channel SFC System for Fast Chiral Method Development and Optimization

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Chapter 1. Introduction

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Basic Principles for Purification Using Supercritical Fluid Chromatography

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Mass Spectrometry in MCAL

Enantiomeric and Diastereomeric Separations of Pyrethroids Using UPC 2

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

TANDEM MASS SPECTROSCOPY

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

A Protocol for High-Throughput Drug Mixture Quantitation: Fast LC MS or Flow Injection Analysis MS?

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Lecture 15: Introduction to mass spectrometry-i

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

UPC 2 Strategy for Scaling from Analytical to Preparative SFC Separations

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Nexera UC Unified Chromatography

Supercritical Fluid Extraction Directly Coupled with Reversed Phase Liquid Chromatography for Quantitative Analysis of Analytes in Complex Matrices

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Supercritical Fluid Chromatography

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Supporting Information

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Technical Note. Introduction

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Use of the SFC-MS Splitter Kit G

Dilution(*) Chromatography

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Electrospray Ion Trap Mass Spectrometry. Introduction

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC)

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

PosterREPRINT AN INTERACTIVE PHYSICOCHEMICAL PROPERTY PROFILING SOFTWARE FOR EARLY CANDIDATE ANALYSIS IN DRUG DISCOVERY INTRODUCTION

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Analysis of Polar Metabolites using Mass Spectrometry

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Determination of 15 phthalate esters by ultra performance convergence chromatography

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

The Analysis of Organophosphate Pesticides by LC/MS Application

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

HPLC Praktikum Skript

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Translational Biomarker Core

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

LC and LC/MS Column Selection Flow Chart

Application Note. Authors. Abstract. Pharmaceuticals

BUFOTENINE Latest Revision: August 16, 2005

Supporting Information. Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Refractive Index Detection Using an Ultraviolet Detector with a Capillary Flow Cell in Preparative SFC

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

High Performance Liquid Chromatography

Contents. Efficient synthesis of 5-(chloromethyl)furfural (CMF) from high fructose corn syrup (HFCS) using continuous flow processing

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Application Note. Edgar Naegele. Abstract

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

SECOBARBITAL Latest Revision: February 15, 1999

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Introduction. Chapter 1. Learning Objectives

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Routine MS Detection for USP Chromatographic Methods

The precursor (TBA) 3 [H 3 V 10 O 28 ] was synthesised according to the literature procedure. 1 (TBA = n tetrabutylammonium).

Introduction to Pharmaceutical Chemical Analysis

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

LC Technical Information

Selecting Detectors for Compounds with No Optical Absorbance

Transcription:

An Investigation of the Impact of Common Experimental Parameters on Signal Intensity in SFC ESI MS Lakshmi Subbarao, Jacquelyn Cole and Rui Chen TharSFC, a Waters Company, Pittsburgh, Pennsylvania, USA Introduction In the past decade, supercritical fluid chromatography (SFC) has experienced a steady growth in acceptance, particularly in pharmaceutical and chemical laboratories. In SFC, a supercritical fluid, most commonly CO 2, in combination with one or more polar organic solvents, such as alcohols, is used as mobile phase. Compared to HPLC, SFC offers better selectivity and shorter analysis time due to the low viscosity and high diffusivity inherent to supercritical fluids [1]. The ongoing acetonitrile (ACN) shortage has also stimulated an elevated interest in employing SFC as a possible alternative to the industry-dominating, ACN-reliant reversed phase LC (RPLC). Advances in detection in SFC have contributed, at least in part, to its resurgence and increased acceptance by HPLC practitioners. The detection in SFC has gradually evolved to encompass many LC-type detectors, including the ultra-violet (UV) detector, the evaporative light scattering detector (ELSD), and the mass spectrometer (MS). As the general analytical philosophy gradually shifts from enhancing capacity and efficiency to generating high-quality and more informative data within a minimal time frame [2], SFC MS readily lends itself as an attractive complement to RPLC MS, mainly due to the combination of the high speed and unique selectivity of SFC and the intrinsic universality, sensitivity, and specificity of MS.

While much has been accomplished in LC MS, in both understanding its fundamentals as well as the practices, their counterparts in SFC MS remain limited in scope. We report herein part of our investigation of the impact of some common experimental parameters on signal intensity in SFC electrospray (ESI) MS. We hope that the observations from our study can stimulate more fundamental research activities in this area; and contribute, albeit small, to a better understanding of this emerging hyphenated technique. Experimental All chemicals were purchased from Sigma Aldrich (St. Louis, Missouri, USA) and used as received. HPLC grade methanol was purchased from Thermo Fisher Scientific. All samples were dissolved in methanol to make stock solutions of.25 mg/ml, with the exception of theobromine, where a saturated solution (estimated to be.2 mg/ml) was used instead. The chemical structures and molecular masses of the compounds used in this study are listed in Table 1. A TharSFC SFC-MS Resolution II system (TharSFC, A Waters Company, Pittsburgh, Pennsylvania, USA) equipped with a 2998 photo diode array (PDA) detector and 31 MS (Waters Corp., Milford, Massachusetts, USA) was used for all experiments. Electrospray mode was used for all experiments. The system was controlled by Masslynx software. A 4.6 x 5 mm silica column (Kromasil, Bohus, Sweden) was used in this study. The effluent after the back pressure regulator (BPR) was directly flown into the inlet of the MS through a 5 µm ID PEEKsil tube (Upchurch, Oak Harbor, Washington, USA). For all experiments, methanol was used as the modifier (co-solvent). Other general experimental parameters included: flow rate, 2. ml/min; injection volume, 5 µl (full loop injection); cone voltage, 4 V; source temperature, 15 C; cone gas flow rate, 7 L/hr; and mass scan, 1 to 4 amu. Investigated parameters were capillary voltage, 2 4 kv; desolvation gas temperature, 4-5 C; and mobile

phase composition, 1 5% methanol. Triplicate injections were performed under each condition and peak areas were averaged for each data point. Results and discussion Figure 1 shows representative extracted ion chromatograms (EIC) of the compounds from all four compound classes. The first parameter we studied was capillary voltage, and the results are summarized in Figure 2. Two neutral polar compounds, sulfamerazine and sulfaquinoxaline, exhibited the highest signal intensity among the group, most likely due to primary amine moiety in the molecules that are highly receptive to protons. Two acidic compounds, ketoprofen and acetaminophen, generated much lower signal intensity, as expected in the positive ionization mode; although the secondary amine group in acetaminophen seemed to significantly boost the MS signal. Across all compound classes, the peak area increased as the capillary voltage increased. Application of higher voltages to the electrospray needle results in the production of smaller droplets, thus, more efficient ionization. The unexpected ionization behavior, i.e. increased signal intensity in the absence of high voltage reported by Langley et al. [3] was not observed in our experiments. It is speculated that the reported unusual ionization behavior is somewhat compound specific. It is noted, however, the likelihood of sonic spray ionization, where ions are formed due to the collision of molecules in the free jet expansion region, is expected to be much higher in SFC MS than in LC MS. One of the major differences between SFC MS and LC MS arises from the mobile phase. In SFC, supercritical CO 2 in combination with one or more polar solvents, most commonly alcohol is used as the mobile phase. The supercritical state, or near-critical state, is maintained by regulating system pressure via a BPR, typically above 1 bar. On the other hand, nebulization and evaporation of the ionization process all take place at near atmospheric pressure. The dramatic pressure drop will cause CO 2 decompression to form a jet spray regardless of the applied capillary voltage. Even without jet spray ionization, the aerosol formation due to CO 2 decompression is beneficial for the electrospray ionization process in the context of either ion-evaporation model or

charge residual model. However, it is also noted this decompression process is highly endothermic. The overall impact is the result of the competition of the opposing factors brought about by CO 2 decompression. Figure 3 summarizes the peak area change as the function of desolvation gas temperature. In general, a higher desolvation temperature (typically 4 C or higher) is required for SFC MS to compensate for the endothermic effect of CO 2 decompression. As shown in Figure 3, the MS signal appeared to slightly decrease as the temperature increased from 4 to 5 C. This is likely due to the thermal degradation of the compounds. And finally, we evaluated the signal dependence on mobile phase composition. In LC MS, mobile phase composition influences MS response by changing the number and size of droplets formed during nebulization and thus, ionization of the analytes, due to the changes in solvent physical properties including viscosity and surface tension. The scenario is vastly different for SFC MS. At lower percentage of modifier, there is more CO 2 expansion, which will lead to more efficient nebulization and possibly more small droplets. Desolvation of the droplets formed, and thus ionization of the analytes, is favored by the initial production of small droplets. This is evidenced by the observed decrease in peak area as the percentage of modifier increased (Figure 4). On the other hand, because of the CO 2 decompression, by the time the analyte reaches the ion source, it is surrounded by virtually 1% modifier regardless of the original percentage. The variation in modifier percentage essentially transpires to the change in flow rate, or more accurately, the rate of liquid flow into the SFC MS interface. The higher the modifier percentage, the higher is the rate of liquid flow. Figure 4 displays a concentration-sensitivity at low modifier percentage (< 2%) and mass-flow-sensitivity at higher modifier percentage (>2%), typical characteristic for ESI [4]. A more detailed analysis will be published elsewhere. Conclusions

A systematic investigation of the impact of capillary voltage, desolvation temperature, and modifier percentage on MS signal intensity in SFC MS was reported. Similar to LC MS, increasing capillary voltage resulted in higher signal intensity, contrary to previous reports that high sensitivity can be achieved in the absence of high voltage in SFC MS. Desolvation temperature seemed to have negligible impact on signal intensity in the range studied; although caution should be exercised to minimize possible thermal degradation of the analytes. In general terms, the MS signal decreased as the percentage of modifier increased due to the decrease in CO2 expansion and the increase in liquid flow rate to the SFC MS interface. References 1. T. A. Berger in Packed Column SFC, R.M. Smith (Editor), Royal Society of Chemistry, Cambridge, UK, 1995. 2. Y. Zhao, P. Sandra, G. Woo, S. Thomas, K. Gahm, D. Semin, LC GC Europe, 17 (24) 224-238. 3. M. A. Thite, R. Boughtflower, J. Caldwell, L. Hitzel, C. Holyoak, S. J. Lane, P. Oakley, F. S. Pullen, S. Richardson and G. J. Langley, Rapid Commun. Mass Spectrom. 22 (28) 3673 3682. 4. R. E. Ardrey in Liquid Chromatography-Mass Spectrometry: an Introduction, John Wiley & Sons Ltd, West Sussex, UK, 23. Jacquelyn Cole graduated from Grove City College with a B. S. in Chemistry. Jacquelyn has been working for TharSFC, a Waters Company as an application chemist and technical support since February 25. Prior to joining TharSFC, Jacquelyn worked in the environmental lab at Allegheny Energy, Greensburg, Pennsylvania and Flexsys in Monongahela, Pennsylvania. Lakshmi Subbarao graduated from University of Delaware with a B.S. in Chemistry in 24 and Illinois Institute of Technology in 28 with a M. S. degree in Analytical Chemistry. Lakshmi joined TharSFC, a Waters Company in January 29 as an application chemist. Prior to joining TharSFC, Lakshmi worked for Advanced Materials Technology (Wilmington, DE). Rui Chen obtained his B.Sc. in Material Chemistry in 1993, and his M. Sc. in Polymer Physics and Chemistry in 1996, both from Fudan University, Shanghai, China. Rui obtained his Ph.D. in 22 in analytical chemistry from the University of Alberta, Canada. In 22, he became an Alberta Ingenuity Research Fellow. In 24, Rui joined the Institute of Chemistry and Cell Biology at Harvard Medical School. Rui joined METTLER TOLEDO AutoChem in September 25. Currently Dr. Chen is the global technical support manager for TharSFC, a Waters Company. Rui has published over 1 papers in peerreviewed journals, and made numerous presentations at national and international conferences.

Name Structure Compound Class Molecular Mass (Da) Hydrocortisone Neutral non-polar 362.5 Progesterone Neutral non-polar 314.5 Caffeine Base 194.2 Theobromine Base 18.2 Ketoprofen Acid 254.3 Acetaminophen Acid 151.2 Sulfamerazine Neutral polar 264.3 Sulfaquinoxaline Neutral polar 3.3 Table 1. Chemical structures and molecular masses of the compounds used in this study.

1 1.11 1 A) B) 2.7 % % Time 1. 2. 3. Time 1. 2. 3. 1 2.15 1 C) D) 3.67 % % Time 1. 2. 3. 2. 4. Time Figure 1. Representative extracted ion chromatograms (EIC) of the compounds used in this study obtained with 15% methanol: A) progesterone (neutral non-polar); B) theobromine (base); C) acetaminophen (acid); and D) sulfamerazine (neutral polar).

7 Peak Area (x 1-6 ) 6 5 4 3 2 1 Hydrocortisone Progesterone Caffeine Theobromine Ketoprofen Acetaminophen Sulfamerazine 2 2.5 3 3.5 4 Capillary Voltage (kv) Figure 2. Peak area vs. capillary voltage. Desolvation gas temperature: 45 C; desolvation gas flow rate: 65 L/hr; modifier percentage: 15% MeOH.

6 Peak Area ( x 1-6 ) 5 4 3 2 1 Hydrocortisone Progesterone Caffeine Theobromine Ketoprofen Acetaminophen Sulfamerazine Sulfaquinoxaline 4 42 44 46 48 5 Temperature ( C) Figure 3. Peak area vs. desolvation gas temperature. Capillary Voltage: 3.5 kv; desolvation gas flow rate: 65 L/hr; modifier percentage: 15% MeOH.

Peak Area (x 1-7 ) 18 16 14 12 1 8 6 4 2 1% 2% 3% 4% 5% Modifier (%) Hydrocortisone Progesterone Caffeine Theobromine Ketoprofen Acetaminophen Sulfamerazine Sulfaquinoxaline Figure 4. Peak area vs. modifier percentage. Capillary Voltage: 3.5 kv; desolvation gas flow rate: 65 L/hr; desolvation gas temperature: 45 C.