Pracownia Podstaw Fizyczne Laboratorium Mikrokomputerowe Wydział Fizyki Eksperymentu Fizycznego Filami UAM. Radioactive decay

Similar documents
Lab #13: MEASUREMENT OF RADIATION DOSES

5) Measurement of Nuclear Radiation (1)

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

11 Gamma Ray Energy and Absorption

6. Atomic and Nuclear Physics

sample What happens when we are exposed to radiation? 1.1 Natural radiation Cosmic radiation

Radiation Quantities and Units

Radiation and Radioactivity. PHYS 0219 Radiation and Radioactivity

Radiation Protection & Radiation Therapy

11/23/2014 RADIATION AND DOSE MEASUREMENTS. Units of Radioactivity

PS-21 First Spring Institute say : Teaching Physical Science. Radioactivity

Dosimetry. Sanja Dolanski Babić May, 2018.

Radiological Preparedness & Emergency Response. Session II. Objectives. Basic Radiation Physics

Radioactive Decay 1 of 20 Boardworks Ltd 2016

The basic structure of an atom is a positively charged nucleus composed of both protons and neutrons surrounded by negatively charged electrons.

WHAT IS IONIZING RADIATION

Unit 08 Nuclear Structure. Unit 08 Nuclear Structure Slide 1

Overview: In this experiment we study the decay of a radioactive nucleus, Cesium 137. Figure 1: The Decay Modes of Cesium 137

Question Bank. Nuclear Physics

Nuclear Radiation. Natural Radioactivity. A person working with radioisotopes wears protective clothing and gloves and stands behind a shield.

4.4.1 Atoms and isotopes The structure of an atom Mass number, atomic number and isotopes. Content

Nuclear Spectroscopy: Radioactivity and Half Life

Radioactivity. Lecture 7 Dosimetry and Exposure Limits

Interaction of the radiation with a molecule knocks an electron from the molecule. a. Molecule ¾ ¾ ¾ ion + e -

Lecture Presentation. Chapter 21. Nuclear Chemistry. James F. Kirby Quinnipiac University Hamden, CT Pearson Education, Inc.

Overview: In this experiment we will study the decay of a radioactive nucleus, Cesium. Figure 1: The Decay Modes of Cesium 137

Waves & Radiation exam questions

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Radiation Safety Basic Terms

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

BASIC OF RADIATION; ORIGIN AND UNITS

Radioactivity. Lecture 7 Dosimetry and Exposure Limits

Differentiating Chemical Reactions from Nuclear Reactions

Core Questions Physics unit 4 - Atomic Structure

Shielding of Ionising Radiation with the Dosimetry & Shielding Module

What do all of these things have in Common?

The Geiger Counter. Gavin Cheung. April 10, 2011

Wallace Hall Academy Physics Department. Radiation. Pupil Notes Name:

College Physics B - PHY2054C

Atomic and nuclear physics

Gy can be used for any type of radiation. Gy does not describe the biological effects of the different radiations.

Become Aware: Preparation for a Radiological Terrorism Event Ionizing Radiation and Its Biological and Human Health Effects

Atomic and nuclear physics

Interaction of Ionizing Radiation with Matter

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

U (superscript is mass number, subscript atomic number) - radionuclides nuclei that are radioactive - radioisotopes atoms containing radionuclides

APPENDIX A RADIATION OVERVIEW

Radioactive nuclei. From Last Time. Biological effects of radiation. Radioactive decay. A random process. Radioactive tracers. e r t.

RADIOACTIVITY IN THE AIR

LECTURE 26 RADIATION AND RADIOACTIVITY. Instructor: Kazumi Tolich

ZX or X-A where X is chemical symbol of element. common unit: [unified mass unit = u] also known as [atomic mass unit = amu] or [Dalton = Da]

Chapter 7 - Radioactivity. Science 10 P

Part 12- Physics Paper 1 Atomic Structure Knowledge Questions

NORM and TENORM: Occurrence, Characterizing, Handling and Disposal

Radioactivity Outcomes. Radioactivity Outcomes. Radiation

Name: COMBINED SCIENCE Topics 4, 5 & 6 LEARNING OUTCOMES. Maintain a record of your progress Use the booklet to guide revision

Number of protons. 2. What is the nuclear symbol for a radioactive isotope of copper with a mass number of 60? A) Cu

Absorption and Backscattering of β-rays

Industrial Hygiene: Assessment and Control of the Occupational Environment

Nuclear Physics and Astrophysics

Chapter 2. Atomic Structure and Nuclear Chemistry. Atomic Structure & Nuclear Chemistry page 1

PHY138Y Nuclear and Radiation

Radioactivity and energy levels

Final Exam. Physics 208 Exit survey. Radioactive nuclei. Radioactive decay. Biological effects of radiation. Radioactive tracers

Radiation Terminology

Absorption of X-rays

Figure 1. Time in days. Use information from Figure 1 to calculate the half-life of the radioactive isotope.

Chapter 18 Nuclear Chemistry

Quantifying Radiation. Applications

21/11/ /11/2017 Atomic Structure AQA Physics topic 4

P7 Radioactivity. Student Book answers. P7.1 Atoms and radiation. Question Answer Marks Guidance

Introduction. Principle of Operation

Atomic Structure and Radioactivity

Absorption and Backscattering ofβrays

Nuclear forces and Radioactivity. Two forces are at work inside the nucleus of an atom

Chapter 21 Nuclear Chemistry: the study of nuclear reactions

Year 9 AQA GCSE Physics Revision Booklet

Homework 5: Radiation. 1. Which sign is used to indicate the presence of radioactive material?

Lecture PowerPoint. Chapter 31 Physics: Principles with Applications, 6 th edition Giancoli

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

Part 12- Physics Paper 1 Atomic Structure Application Questions Combined Science

LECTURE 26 RADIATION AND RADIOACTIVITY

National 5. Waves and Radiation. Summary Notes. Name:

NAT 5 - Waves and Radiation Powerpoint Answers

Determining the Efficiency of a Geiger Müller Tube

What is Radiation? Historical Background

Chapter 29. Nuclear Physics

Chapter 20: Phenomena. Chapter 20: The Nucleus: A Chemist s View. Nuclear Decay. Nuclear Decay. Nuclear Decay. Nuclear Decay

9 Nuclear decay Answers to exam practice questions

Radiation Protection Fundamentals and Biological Effects: Session 1

RADIOACTIVE DECAY - MEASUREMENT OF HALF-LIFE

4.4 Atomic structure Notes

INTRODUCTION TO IONIZING RADIATION (Attix Chapter 1 p. 1-5)

Georgia Institute of Technology. Radiation Detection & Protection (Day 3)

Question. 1. Which natural source of background radiation do you consider as dominant?

Classroom notes for: Radiation and Life Lecture Thomas M. Regan Pinanski 207 ext 3283

05/11/2013. Nuclear Fuel Cycle Ionizing radiation. Typical decay energies. Radiation with energy > 100 ev. Ionize an atom < 15eV

The sources include Am-241 which emits alpha radiation, Sr-90 which emits beta radiation and Co-60 which emits gamma radiation.

Absorption of Gamma Rays

Radioactivity. PC1144 Physics IV. 1 Objectives. 2 Equipment List. 3 Theory

Transcription:

Radioactive decay Aim of the experiment: determination of background radiation, determination of absorption of radioactive radiation. Instruments: computer system with interface, sensor of ionising radiation, weak radioactive source. Problem: radioactivity References: S5.2 (69-86), JD3 (17), HS (29.0, 29.1), statistical distribution of results of measurements HS (1.3). 1. Introduction Ionising radiation induces ionisation of the medium in which it propagates. Such properties show X-ray radiation, radioactive radiation, and electromagnetic radiation in the near ultraviolet range. Energy of ionising radiation is measured in joules (J). To facilitate the description of the phenomenon, some additional physical quantities are introduced: Radioactive activity of a source A is defined as the number of decays per second: dn( t) A N( t) (1) dt where N(t) is the number of atomic nuclei of radioactive material that have not decayed at time t, while is the radioactive decay constant describing how many nuclei undergo decay in a unit of time, so describing the rate of radioactive decay. Radioactive activity is expressed in becquerels (Bq) (1 Bq = 1 decay per 1 second) or in Curies Ci (1 Ci = 3.7 10 10 decays per 1 second = 3.7 10 10 Bq). Exposition dose is a measure of the ionising radiation ability to ionise the air through which it passes. The unit of exposition dose is roentgen (R); one roentgen is defined as the dose

which provides 8.78 mj of energy to 1 kg of dry air in normal conditions. Earlier one roentgen was defined as the dose which in 1 cm 3 of dry air in normal conditions generates ions of each sign of the total charge equal to one electrostatic unit. The exposition dose describes the energy lost by ionising radiation and not the dose of energy absorbed by the medium. Absorbed dose the dose of radiation absorbed by a certain medium is measured in greys (Gy). The absorbed energy is equal to 1 Gy, if 1 kg of the medium absorbs the energy of 1 J. There is another unit still in use, roentgen defined as 1 R = 0.01 Gy. In medicine and biology it is convenient to use the equivalent of exposition dose or equivalent dose expressed in sieverts (Sv). Equivalent dose is a dose quantity used in radiological protection to represent the stochastic health effects (probability of cancer induction and genetic damage) of low levels of ionising radiation on the human body. It is based on the physical quantity absorbed dose, but takes into account the biological effectiveness of the radiation, which is dependent on the radiation type and energy. To calculate equivalent dose the dose expressed in greys is multiplied by coefficients of relative biological effectiveness. The coefficients are tabulated, for gamma irradiation and electrons they are close to one, for alpha irradiation this coefficient is close to 10. There is also another not SI unit in use 1 REM = 0.01 Sv. The activity of the source used in the experiment you are going to perform is so low that it has no effect on the experimenter health. 2. Experiment To perform the experiment you need a Geiger Müller counter (G-M), voltmeter, a connector box interfacing the G-M counter with an acquisition card plugged into a PC and a program working in LabView environment. The sensor comprising a G-M counter is in a special case with connections to the connector box. The G-M counter is mounted in the front of the case and its cross-section area is close to 1.5 cm 2. Behind it there is a potentiometer regulating the supply voltage in the range from 300 V to 800 V. On the right hand side there is a potentiometer knob, while on the left hand side there is a terminal permitting a connection with a voltmeter of very high input resistance. The G-M counter is adapted for measurements of and radiation. Determination of Geiger Müller characteristic. The sensitivity of a G-M counter

depends on the voltage applied to it, that is why it is necessary to start with determination of the working voltage for which the counter sensitivity is the highest. To do this, the sensor must be connected to the acquisition card through the connector box. At a distance of a few centimetres from the front wall of the sensor, place a source of radiation of very small activity. Then, you should start the program Badanie rozpadu promieniotwórczego [a study of radioactive decay] available on the computer desktop and then choose the tab : G-M counter characteristics (Fig. 1). Figure 1. The screen view of the program Badanie rozpadu promieniotwórczego [a study of radioactive decay], the part needed for determination of the Geiger Müller counter characteristics. In the box Czas zliczania [time of counting] you should introduce time of counting e.g. 1 minute in which you want to count the pulses of radiation in a certain step of measurements. Connect the voltmeter to the sensor. With the help of the potentiometer mounted in the back of the sensor, change the voltage supplied over the range available. Write the value of voltage read on the voltmeter in the appropriate box on the computer screen. Start the measurement by pressing the button Zlicz impulsy [count the pulses]. The data are collected

by the program, which presents them graphically on a plot. Make 3 measurements for each value of voltage. In the next step change the voltage value and repeat the measurement. On the basis of the plot you should establish the working voltage and set it by the potentiometer. Distribution of the number of pulses recorded in stable conditions. Having set the working voltage, place the source of radiation at such a distance from the sensor to get the number of counts in a certain period of time (e.g. 1 minute) smaller than 20. Now, record the number of counts for over 100 times and then analyse the statistical distribution of the results as shown in Section 1.3 of the book Pracownia Fizyczna. Determination of damping of ionising radiation. On passing through matter the ionising radiation is weakened because of the loss of the energy used for ionisation. The intensity of radiation beam I, after passing through the active medium layer of the thickness d, exponentially decreases according to the expression: I d I 0 e, (2) where I 0 stands for the initial intensity of the beam prior to entering the active medium (absorbent) and is the linear coefficient of damping, depending on the composition of the medium and on the energy of the radiation. The ability of a given medium [material] to absorb and scatter ionising radiation is characterised by the damping coefficient. The damping of radiation is often characterised by another parameter, the so-called half-value layer (HVL) or half-value thickness d 1/2. It is the thickness of the material at which the intensity of radiation entering it is reduced by one half. The half-value thickness can be obtained from the equation (2): 0 equivalent to I 0 2 d1 / 2 I e (3) 0 1 d 1/ 2 ln 2 (4) The aim of the next experiment is determination of the half-value thickness of aluminium or the decay constant of the decaying quantity. In this part of measurements use the tab Analiza eksponencjalnego zaniku [analysis of exponential decay] shown in Fig. 2.

Figure. 2. View of computer screen for determination of the half-value thickness of an active medium or its half-value decay time. In the upper tab switch to Absorpcja promieniowania jonizującego [absorption of ionising radiation]. In the box Czas zliczania write the time of pulse counting in subsequent measurements (e.g. 100 s). Place a certain layer of studied material between the source and the G-M counter. Enter its thickness (in [m]) in the editing window Grubość d [thickness d]. By pressing the button Zlicz impulsy [count pulses] the process of counting the pulses for a given sample starts. Repeat this procedure for a series of samples of different thicknesses. The data collected can be analysed with the help of the tool-panel below the screen. By marking the option Pokaż model [show the model] the plot of the following function is displayed on the screen: y d A1 A0e (5)

Changes in the parameters A 1, A 0 and result in a dynamic change in the course of the line displayed. Select the most suitable parameters and start the process of fitting the function by pressing the button Dopasuj [adjust]. The procedure of fitting the function to the data is based on the Levenberg- Marquardt algorithm and ends with getting the best fit parameters displayed in the boxes of parameters. On the basis of the best fit parameters the value d 1/2 is calculated. To see the experimental data and best fit parameters press the button Pokaż dane i wyniki [display data and results]. Press the button Wyczyść wykres [erase the plot] to remove the plot and remove the data from memory. The buttons Otwórz [open], Zapisz [write] and Drukuj [print] start the respective processes.