[VIM = 4 R3 gx ( 3)

Similar documents
(3) A UNIVERSAL CALIBRATION FOR GEL PERMEATION CHROMATOGRAPHY. [TIM = 4 R3 gx POLYMER LETTERS VOL. 5, PP (1967)

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Macromolecular Chemistry

Author(s) Donkai, Nobuo; Nakazawa, Atsushi; I.

Gel Permeation Chromatography

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Application compendium. Authors. Greg Saunders, Ben MacCreath Agilent Technologies, Inc. A guide to multi-detector gel permeation chromatography

Molecular Weights of Copolymers Obtained by Gel Permeation Chromatography Light Scattering

How to use GPC/SEC for compositional analysis

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

Differentiation of polymer branching and composition using the Mark Houwink plot

Latest Developments in GPC Analysis of Adhesive and Sealant Polymers Mark Pothecary PhD Americas Product Manager Malvern Instruments

Polymers Reactions and Polymers Production (3 rd cycle)

Sem /2007. Fisika Polimer Ariadne L. Juwono

GPC / SEC Theory and Understanding

Size exclusion chromatography of branched polymers: Star and comb polymers

An Introductions to Advanced GPC Solutions

Progress toward reliable NC molecular mass distribution by GPC

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

c) fitting of the NMR intensity in dependence of the recycle delays 4

Optimizing GPC Separations

GPC/SEC An essential tool for polymer analysis

Dr. Christoph Johann Wyatt Technology Europe GmbH Copyright Wyatt Technology Europe GmbH All Rights reserved 1

How Molecular Weight and Branching of Polymers Influences Laser Sintering Techniques

Gel Permeation Chromatography

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

CHARACTERIZATION OF BRANCHED POLYMERS IN SOLUTION (I)

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

Polymer analysis by GPC-SEC. Technical Note. Introduction

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Static and dynamic polystyrene dimensions in relation to the blob model and size-exclusion chromatography

GPC/SEC standards. Product guide

Molecular Weight of Polymers *

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

GPC/SEC standards. Product guide

Physical Polymer Science Lecture notes by Prof. E. M. Woo adapting from: Textbook of Physical Polymer Science (Ed: L. H.

GRAFT COPOLYMERS OF STYRENE AND METHYL METHACRYLATE

MOLECULAR CHARACTERIZATION OF POLYETHYLENE

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

Practical Steps in GPC Method Development

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Maximizing Performance Through GPC Column Selection

Determination of Molecular Weight and Its Distribution of Rigid-Rod Polymers Determined by Phase-Modulated Flow Birefringence Technique

COURSE MATERIAL: Unit 3 (Part 1) Polymer Science LT8501 (Click the link Detail to download)

Solution Properties of Poly(dimethyl siloxane)

Setting the Standard for GPC. Complete Guide for GPC / SEC / GFC Instrumentation and Detection Technologies. The Right Instrument for Your Application

A Question of Molecular Weight

HYPERBRANCHED METHACRYLATES BY SELF-CONDENSING GROUP TRANSFER POLYMERIZATION. Peter F. W. Simon, Wolfgang Radke, Axel H. E. Müller

Supporting Information

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Author(s) Min, Tea-Ik; Miyamoto, Takeaki; Ina.

The power of multi-detector SEC in the analysis of antibodies

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Field-Flow Fractionation of Macromolecules and Structures That Cannot be Characterized by Conventional GPC/SEC Techniques

The ph-responsive behaviour of aqueous solutions of poly(acrylic acid) is dependent on molar mass

Combined metallocene catalysts: an efficient technique to manipulate long-chain branching frequency of polyethylene

The Differential Viscometer. 11. On-Line Viscosity Detector for Size-Exclusion Chromatography

Chap. 2. Molecular Weight and Polymer Solutions

Branching Revealed: Characterizing Molecular Structure in Synthetic and Natural Polymers by Multi-Angle Light Scattering

(Published in Journal of Liquid Chromatography 2(3): (1979) GEL PERMEATION CHROMATOGRAPHY OF POLYMERS FROM WOOD

Tips & Tricks GPC/SEC: From a Chromatogram to the Molar Mass Distribution

Part 8. Special Topic: Light Scattering

Viscoelastic Flows in Abrupt Contraction-Expansions

Supporting Information

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Chapter 14. Molar Mass Distribution.

How switching mobile phases can improve your OMNISEC results

Polymer Analysis by Gel Permeation Chromatography

Comprehensive Polymer Analysis Strategies

Technical Report No* 3

Relationship of Rheological Behavior and Molecular Architecture for LDPE Designed for Extrusion Coating. Bert Nijhof Technical Paper-7603

Skript zum Praktikum. (Lab course macromolecular chemistry: physical chemistry )

Size Exclusion Chromatography of Poly(2-ethyl-2-oxazoline) Homopolymers and Poly(ethylene oxide)-b-poly(2-ethyl-2-oxazoline) Copolymers

CALIBRATING GPC COLUMNS

GPC/MS. Analysis of PET

Particle Characterization Laboratories, Inc.

Determination of the propagation rate coefficient for 3-[tris(trimethylsilyloxy)silyl] propyl methacrylate by pulsed-laser polymerization

SIZE EXCLUSION CHROMATOGRAPHY

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

One-pot polymer brush synthesis via simultaneous isocyanate coupling chemistry and grafting from RAFT polymerization

Chapter 3. Molecular Weight. 1. Thermodynamics of Polymer Solution 2. Mol Wt Determination

PAPER No. 6: PHYSICAL CHEMISTRY-II (Statistical

Dilution and polydispersity in branched polymers

CASE STUDY. Degradation of Polyethylene by FTIR and High Temperature GPC

Size Exclusion Chromatography

Analysis of Fragile Ultra-High Molar Mass. d Chromatography. Amandaa K. Brewer October 22, 2015

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Power Law of Molecular Weight of the Nucleation Rate of Folded Chain Crystals of Polyethylene

CHAPTER 10 DENSITY AND VISCOSITY AS REAL-TIME PROBES FOR THE PROGRESS OF HIGH-PRESSURE POLYMERIZATION:

GPC/SEC Analysis of Polymer Degradation

Supporting Information

ANALYSIS OF POLYMER BLENDS BY GPC-FTIR

Living Cationic Polymerization of p-alkoxystyrenes by Free Ionic Species

Anomalous phase behavior in blends of -SO 3 H terminated polystyrene with poly(n-butyl acrylate) containing a small amount of tertiary amino groups

Zwitterionic Polymerization: A Kinetic Strategy for the Controlled Synthesis of Cyclic Polylactide

Supporting Information. Reduction- and Thermo-Sensitive Star Polypeptide Micelles. and Hydrogels for On-Demand Drug Delivery

Tips & Tricks GPC/SEC: Inter-Detector Delay

Single-ion BAB triblock copolymers as highly efficient electrolytes for lithium-metal batteries

Transcription:

POLYMER LETTERS vol. 5, PP. 753-759 (1967) A UNIVERSAL CALIBRATION FOR GEL PERMEATION CHROMATOGRAPHY Gel permeation chromatography is one of the most powerful techniques for characterizing the polydispersity of polymeric materials (1). A versatile commercial apparatus (2) has been used successfully in numerous laboratories on various problems of molecular weight distributions. But one of the difficulties still unsolved is the problem of calibration, i.e., the relation between elution volume and molecular weight. Some authors (2) have assumed that retention time depends on the contour length of the molecular chain. Others think that it is more reasonable to use the radius of gyration or some average volume of the polymer molecule as the calibration parameter. In a recent paper (3) we have reported GPC retention times of a series of polystyrenes exhibiting different molecular structures: linear, star-shaped, and comb-like. All were of known molecular weight and of low polydispersity. Obviously the conventional calibration method, where the logarithm of molecular weight is plotted against elution volume, does not yield a universal curve for all the samples. Retention times for branched samples were always larger than those for the linear homologs of the same molecular weight. We therefore tried using the hydrodynamic volume as the calibration parameter. According to the Einstein viscosity law one can write where [?I is the limiting viscosity index, V the hydrodynamic volume of the particles, M their molecular weight, and K a constant. This equation shows that the product [q]m is a direct measure of the hydrodynamic volume of the particles and suggests the use of log [q]m, instead of log M, in the calibration of the chromatograms. With this type of plot, all our experimental points fall on the same curve. This assertion is supported by the following considerations. It is well known that for branched polymers one can write or [VIM = 4 R3 gx - 3 2 ( 3) where R is the actual radius of gyration, g is the parameter introduced 753 Journal of Polymer Science: Part 9: Polymer Physics, Vol. 34,1707-1713 (1996) 0 1996 John Wiley & Sons, Inc. CCC 0887-6266/96/101707-07 1707

1708 GRUBISIC, REMPP, AND BENOIT 754 POLYMER LETTERS by Zimm and Stockmayer (4), q5 is a universal constant, and x is an exponent ranging from 1/2 to 31 2 depending upon the theory used. If this is true, it means that it is the hydrodynamic volume-obtained from viscometric data-which determines retention in the chromatographic columns. But if the hydrodynamic volume is the parameter responsible for GPC retention, the above calibration should be valid for any polymer, regardless of its chemical nature as well as of its morphological structure: it should be universal, and thus be characteristic for any given set of columns and elution solvent at a given temperature. We have measured GPC elution volumes of a number of polymer samples chosen for their small polydispersity. The polymers, obtained in most cases through anionic reaction mechanisms, were: polystyrene (PS), poly(methy1 methacrylate) (PMM), polybutadiene, and poly(viny1 chloride) samples which can be considered as having linear molecular structure; block and graft copolymers of styrene and methyl methacrylate; star-shaped polystyrenes and poly(methy1 methacrylates); heterograft copolymers composed of a three-block sequence PMM-PS-PMM, with PS grafts on the PMM blocks. Molecular weights M were determined by light scattering (Sofica apparatus) in suitable solvents; control of polydispersity rendered it necessary, sometimes, to get number-average values through osmometry (Mechrolab equipment). Intrinsic viscosities were measured, for all samples, on tetrahydrofuran solutions in a capillary viscometer at 25OC. The gel permeation chromatography experiments were carried out on a Waters machine equipped with 4 columns (lo6, los, lo4, 9 x 10 A.), at room temperature. The solvent was tetrahydrofuran. Injection time was 2 min. and pumping rate was always 1 ml./min. All the chromatograms were quite sharp and almost symmetric. The maximum of the peak was taken as the elution volume for each of the tested polymers and the log of the product [TIM was plotted as a function of this elution volume, which was measured in 5-ml. increments (counts). The results are collected in Table I, and a plot is shown in Figure 1. It can be seen that all of the experimental points lie on a single curve. This confirms our hypothesis according to which the viscometric hydrodynamic volume, characterized by [TIM, determines retention in the chromatographic column. It is interesting to note that this universal calibration curve takes into account interactions of all types-those between polymer and solvent, and in the case of copolymers the hetero- contact interactions-which are included in [TI. This explains why molecular weight calibration curves, i.e., log M vs. elution volume, established for each homologous series exhibit different slopes (Fig. 2): in a given Solvent the viscosity laws for different polymers have different exponents.

TABLE I 'd I _ 0 '? Y Sample Shape r7/1 x Mw z Elution vol. m counts. 5 ml.!z Polystyrene Linear 13,000 11.5 1.49 x lo5 28.2 m PS 68,000 31.3 2.13 x lo6 25.4 cl cl 213,000 81.5 1.74 lo7 23.1 m 290,000 96.7 2.80 x lo7 22.6 E 934,000 220.5 2.06 x lo8 20.7 2,230,000 391 8.7 x lo8 19.6 r Poly(methy1 methacrylate) PMMA Poly(viny1 chloride) PVC Polybutadiene Linear Linear Linear 170,000 54.4 9.25 x lo6 23.5 570,000 96.0 5.47 x lo7 22.0 947,000 1,277,000 190 2 16 1.80 x 10' 2.76 x 10' 20.6 20.4 27,000 40 1.08 x lo6 26.1 40,000 42.3 1.69 x lo6 25.6 46,500 42 1.95 x lo6 25.5 85,000 78 6.6 x lo6 24.3 100.000 83 8.3 x lo6 24 390,000 255 9.94 x lo7 21.5 Polystyrene PS Comb 147,000 19 2.91 x lo6 25.0 294,000 24.4 7.17 x lo6 23.9 550,000 41.4 2.28 x lo7 23.0 2,040,000 86.5 1.76 x 10' 20.75 3,600,000 116.5 4.19 x 10' 21.0 11,200,000 160 1.68 x lo9 19.2

+I +I m E Polystyrene PS PS/PMMA graft copolymer PS/PMMA Poly(pheny1 siloxane) TP-62-4 Stat Comb Heterograft a Ladder 146,000 23.5 3.43 x lo6 24.9 176,000 23 4.05 X lo6 24.75 409,000 59.8 2.45 x lo7 22.7 590,000 67.5 3.98 X lc7 22.3 460,000 41.8 1.92 x 10' 23.0 830,000 57.5 4.77 x 107 22.05 122,000 15 1.83~ lo6 25.6 235,000 24.8 5.83 X lo6 24.3 308,000 23.7 7.29 x lo6 23.8 311,000 27.3 8.50 x lo6 24.2 1,400,000 56.3 7.88 x lo7 21.5 3,630,000 81.6 2.96 x 10' 20.2 5,200,000 318 1.65 x lo9 20.7 TP-61 840,000 380 3.19~ 10' 20.2 325 2.73 x lo8 20.2 TP-62 1,720,000 280 4.81 x lo8 20 256-3 4.40 x lo8 20 or PS/PMM Linear 234,000 89.6 2.09 x 107 23.0 4 statistical copolymer E w 'See text. r m

JOURNAL OF POLYMER SCIENCE 50TH ANNIVERSARY 1711 POLYMER LETTERS 757 I og. r1i M lo! 10 10' 10' A HETERO GRAFT COPOL. )I POLYMETHYLMETHACRYLATE o WLYVINYLCHLORIDE V GRAFT COPOL. PS/PMMA POLYPHENYLSILOXANE 10 0 POLYBUTADIENE 1 I 18 20 22 24 26 20 30 Elution Volume _c ( 5 6 counis,thf solvinl) Figure 1. Recently it has been shown (4) that the log [q]m plot also furnishes a good fit for polystyrene and for poly( L-benzyl glutamate) in dimethylformamide. It is well known that the shape of these molecules is quite different: the first is a coil, the other a rigid rodlike molecule. Therefore, this result suggests that our calibration is independent of the shape of the molecules and is valid for elongated particles as well. Recently, Meyerhoff (5) published his own results in this field, and according to him the plots of log [q] 1/3M1/2 vs. elution volume should yield parallels for different polymeric series. Although the theoretical basis of this plot is not very convincing, we plotted our own experimental results according to Meyerhoff and obtained for each type of polymer a different straight line, but all the lines were parallel. Thus

1712 GRUBISIC, REMPP, AND BENOIT 758 POLYMER LETTERS Elution Volume Ismi counts,thf solvinl) - Fig. 2. GPC calibration: polystyrene/thf. it is demonstrated that the calibration proposed by Meyerhoff cannot be considered universal, since different polymeric series yield different curves for the same set of columns, the same solvent, and the same t emper at ure. The question now arises if it would not be possible to obtain the same kind of results using the radius of gyration. From our data on graft polymers this seems not to be the case. The value of x in eq. (3) is often assumed to be 1/2 (Zimm and Kilb) (7). Since in our samples g values range from 1 to 0.2, there is for the most highly branched polymers a factor of five between hydrodynamic and geometrical volumes, which makes it impossible to have a good fit in both representations. It is somewhat surprising to obtain such a good fit with the volume obtained viscometrically, and one could ask why another hydrodynamic volume, such as that obtained from translational brownian motion, could not be used. If one looks at the molecules moving in front of the pores

JOURNAL OF POLYMER SCIENCE 50TH ANNIVERSARY 1713 POLYMER LETTERS 759 in a velocity gradient, just as in a viscosity experiment, one could assume that it is the volume perturbing the flow that also governs the entry of molecules into the pores. But this is merely a hypothesis. Even if this explanation is not valid, this new method of calibration seems promising. GPC results can be considered as a combination of molecular weight and viscosity. Owing to the ease of both GPC and viscosity experiments, this method can be used for molecular weight determinations on unknown polymers, and it should be especially useful and efficient for polymers soluble only at elevated temperatures. We thank Mrs. Decker, Messrs. Curchod, Guyot, Gallot, and Zilliox for some of the samples we have used. References (1) J. C. Moore, J. Polymer Sci. A, 2, 835 (1964). (2) L. E. Maley, in Analysis and Fractionation of Polymers (J. Polymer Sci. C, S), J. Mitchell, Jr. and F. W. Billmeyer, Jr., Eds., Interscience, New York, 1965, p. 253. (3) H. Benoit, Z. Grubisic, P. Rempp, D. Decker, and J. G. Zilliox, J. Chim. Phys., 43, 1507 (1966). (4) B. H. Zimm and W. H. Stockmayer, J. Chem. Phys., x, 1301 (1949). (5) Z. Grubisic, L. Reibel, and G. Spach, Compt. Rend., in press. (6) G. Meyerhoff, Makromol. Chem., 82, 282 (1965); G. Meyerhoff, Ber. Bunsenges. Physik., @, 866 (1965). (7) B. Zimm and R. W. Kilb, J. Polymer Sci., z, 19 (1959). Centre de Recherches sur les Macromolecules Strasbourg, France Received March 27, 1967 Revised May 22, 1967 Z. Grubisic P. Rempp H. Benoit