ISEmax CAS40D. Technical Information

Similar documents
ISEmax CAM40/CAS40. Technical Information

Operating Instructions ISEmax CAS40D

ph/redox Measurement CPM 280

Chloromax CCS142D. Technical Information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Application Your benefits

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Operating Instructions for Digital Manometer. Model: MAN-SD

Stamolys CA71HA. Technical Information

Conductivity sensor for hygienic applications

ED 701 General Industry Pressure Transmitter

Pressure Transmitter ED 701

Installation guide 862 MIT / MIR

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Pressure Measurement Single-range transmitters for general applications

Field IT 50T Series Transmitters

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

NH 3 -selective electrodes

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Sterilizable non-glass IsFET sensor for ph Measurement TopHit CPS 471

Mineral-insulated thermocouples to DIN and EN

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Calio-Therm NC Type Series Booklet

Direct-operated 2/2-way solenoid valves Type EV210B

The FLUX F 430 with mechanical seal

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Compact ph Measuring Instruments With Pro Engineering

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Direct-operated 2/2-way compact solenoid valves Type EV210A

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

ATEX/IECEx RTD temperature probe

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Air velocity & IAQ measuring instruments

Automatic titrators, TitroMatic

Residual Chlorine Monitor

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Pressure transmitters for industrial applications MBS 32 and MBS 33

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Kjeltec 2300 Analyzer Unit

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Air velocity & IAQ measuring instruments

473-SHX Dew Point Mirror

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

Solenoid valves 2/2-way direct-operated type EV210A

One-hand ph/temperature measuring instrument

Thermometers. Applications

EX-EMERGENCY LIGHT FITTINGS

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Differential ph Probe Type 18

Cartridge Valves Technical Information. Quick reference

Concise laboratory catalogue

VD1 CLC. Small Valves DIN-range with a higher k v -value

Rotary modules.

Reflex-Radar BM 100 A

FVBSS fixed volume bottle

Non-Contact Safety Systems CMS

Mercury Stack Monitor SM-4

Exchangeable measuring insets SensyTemp TSA101

FLOW SENSOR FOR LIQUID MEDIA Serie 210

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

473 Dew Point Hygrometer

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

SmartLine Radar Level Meter RM70

OCS 140 / 141 Sensors for Free Chlorine Operating Instructions

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

PHOENIX CONTACT - 04/2016. Features

Presco AG. Standard Air Capacitor 10 nf / 2 kv. Type CL-0N10-K201. User's manual

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

Metso Concentration Measurement 3300

473 Dew Point Hygrometer

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

ADI 2040 Process Analyzer

Nanotechnology Sensors

PRODUCT CATALOGUE PREssURE switch

OEM Flow sensor for liquid media type 200

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Linear measuring technology

Transcription:

Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor works directly in the activated sludge basin of the sewage treatment plant without any sample conditioning or sample transportation. A complete measuring system consists of a sensor with electrodes and a transmitter with display and operating elements. The sensor is used to monitor the ammonium and nitrate content in the activated sludge basin in the preclarification outlet. Your benefits Reliable, cost-saving unit: Direct measurement of ammonium or nitrate without costly sample conditioning Optional potassium and/or chloride measurement, also to compensate high concentrations of interference ions ph measurement as standard Low operating costs since no reagent used Versatile and flexible: Large measuring range 0.1-1000 mg/l NH 4 -N or 0.1-1000 mg/l NO 3 -N Easy-to-use and safe: Installed directly on the basin rim, no measuring container or sample-conveying pump required Minimum maintenance thanks to compressed air cleaning Membrane cap replacement every 6 months prolongs electrode service life Standardized communication enables Plug&Play TI491C/07/EN/01.11 71130404

Function and system design Measuring principle At the heart of the ion-selective electrode (ISE) is a membrane that is selective for the ion to be measured. An ionophore is integrated into the membrane which facilitates the selective "migration" of a specific type of ion (e.g. ammonium or nitrate) to the electrode. As a result of ion migration, a change in the charge occurs, causing the creation of a potential that is proportional to the ion concentration logarithm. The potential is measured against a reference electrode with a constant potential and converted to a concentration using the Nernst equation. With the potentiometric measuring principle, the color and turbidity do not affect the measurement result. 1 A B 1 A B 1 2 3 4 5 Reference electrode 1) Ion-selective electrode Inner metal lead Inner electrolyte (reference) Junction Inner electrolyte (ISE) Ion-selective membrane 2 4 3 General measuring principle of an ion-selective electrode 5 a0009231 1) When using a ph single-rod measuring cell such as the CPS11, its reference is also the reference electrode for the overall sensor and for the ph electrode itself. Interference Depending on the selectivity of the ion-selective electrode vis-à-vis other ions (interference ions), and the concentration of these ions, such ions could also be interpreted as part of the measuring signal and thus cause measuring errors. When measuring in wastewater, the potassium ion which is chemically similar to the ammonium ion can cause higher measured values. The measured values for nitrate can be too high due to high concentrations of chloride. To reduce measuring errors resulting from such cross-interference, the concentration of the potassium or chloride interference ion can be measured and compensated for with a suitable additional electrode. 2 Endress+Hauser

Measuring system A complete measuring system comprises: Sensor CAS40D Ion-selective electrode(s) for ammonium, nitrate, potassium or chloride ph glass electrode, Orbisint CPS11-1AT2GSA Temperature sensor, CTS1 Transmitter, e.g. Liquiline CM442 Optional Assembly holder, e.g. CYH112 Weather protection cover - absolutely essential if mounting the transmitter outdoors! Compressed air generator (if no compressed air available on site) Example: measuring system on basin rim 1 Wastewater assembly holder, secure to rail, with transverse pipe and chain 2 Transmitter, e.g. Liquiline CM442 (in graphic: wall-mounted with weather protection cover) 3 Rail 4 5 6 a0015206 Sensor CAS40D with ion-selective electrodes Connection for optional compressed air cleaning (not in graphic) Sensor cable Endress+Hauser 3

Input Measured variables Measuring ranges Depending on version: Ammonium: NH 4 -N, NH 4 + [mg/l] Nitrate: NO 3 -N, NO 3 - [mg/l] Potassium, K + [mg/l] Chloride, Cl - [mg/l] ph value Temperature Ammonium: 0.1 to 1000 mg/l (NH 4 -N) Nitrate: 0.1 to 1000 mg/l (NO 3 -N) Potassium: 1 to 1000 mg/l Chloride: 1 to 1000 mg/l Wiring Electrical connection The sensor will be connected to the transmitter as follows: With the M12 plug (version: fixed cable, M12 plug) or With the fixed cable connected to the terminal strips (version: fixed cable, end sleeves): Sensor connection a0012460 The maximum cable length is 100 m (328 ft). 4 Endress+Hauser

Performance characteristics Response time t 90 1) Maximum measured error Repeatability Ammonium: < 2 min. Nitrate: < 2 min. Potassium: < 2 min. Chloride: < 2 min. ± 5 % of the measured value ± 0.2 mg/l ±3 % of the display value Compensation Sensor Temperature ph Potassium 1)2) Chloride 1)3) Ammonium ph 8.3 to 10 1 to 1000 mg/l (ppm) - Nitrate - - 10 to 1000 mg/l (ppm) 2 to 40 C (36 to 100 F) Potassium - - - Chloride - - - 1) The fluctuations in concentration, not the absolute value, are the determining factor 2) Recommendation: Use as compensation electrode for potassium concentrations > 40 mg/l in the case of simultaneously fluctuating values of ± 20 mg/l, or apply an offset in the case of non-fluctuating values. 3) Recommendation: Use as compensation electrode for chloride concentrations > 500 mg/l in the case of simultaneously fluctuating values of ± 100 mg/l, or apply an offset in the case of non-fluctuating values. Maximum operating life Automatic cleaning Membrane and electrolyte Use: 0.5 years Storage: 2 years Cleaning medium: Air Pressure: 3 to 3.5 bar (30 to 50 psi) Volume of air required per cleaning cycle: 3 to 4 l (0.8 to 1 US gal) Cleaning duration: 4 to 15 s Cleaning intervals (at T > 10 C (50 F)): Sludge activation inlet: 15 s cleaning, 30 min pause Sludge activation: 15 s cleaning, 1 hour pause 1) For a change between 0.5 and 1 mmol/l in both directions, at 25 C (77 F) Endress+Hauser 5

Environment Ambient temperature range Storage temperature -20 to 50 C (-4 to 120 F) 2 to 40 C (36 to 100 F) Protection class IP 68 Electromagnetic capability Interference emission and interference immunity as per EN 61326, Namur NE21 Process Process temperature range Process pressure ph value of the medium 2 to 40 C (36 to 100 F) 400 mbar (160 inh 2 O) max. permitted overpressure Ammonium: ph 5 to 8.3 (without ph compensation) ph 5 to 10 (with ph compensation) Nitrate: ph 2 to 12 Potassium: ph 2 to 12 Chloride: ph 1 to 10 6 Endress+Hauser

Mechanical construction Dimensions Dimensions CAS40D a0015207 Weight Approx. 3.5 kg (7.7 lbs) Material Sensor - Protective cage: - Electrode holder: - Flat seals: - O-rings for electrode holder and sensor head: - O-rings in ISE holder: - O-rings for air nozzle: - Sensor pipe with coupling nut: - Retaining bracket: - Sensor head: - Temperature sensor: - ph single-rod measuring cell with reference: Ion-selective electrodes - Membrane cap: - Shaft: - Color ring: - Membrane: - O-rings: POM POM Silicon EPDM EPDM Viton PP Stainless steel POM Glass Glass, PTFE POM POM PP PVC, plasticizer EPDM Electrode process connection Pg 13.5 Compressed air connection for hose with OD 8 mm Endress+Hauser 7

Certificates and approvals 4 approval Declaration of conformity The product meets the requirements of the harmonized European standards. It thus complies with the legal requirements of the EC directives. The manufacturer confirms successful testing of the product by affixing the 4 symbol. Ordering information Product structure Approval AA Non-hazardous area Version 1 Immersion operation, ph electrode CPS11, temperature sensor CTS1 ISE slot 1 A1 Ammonium B1 Nitrate C1 Potassium D1 Chloride Adapter cable A Fixed cable, ferrules B Fixed cable, M12 connector Cable length 1 3 m 2 7 m 3 15 m 7... m, specify the desired length. 8... ft, specify the desired length. CAS40D- F1 F2 F3 F4 G1 G2 G3 G4 Z1 Complete order code ISE slot 2 (optional, single selection only) Ammonium Nitrate Potassium Chloride ISE slot 3 (optional, single selection only) Ammonium Nitrate Potassium Chloride Identification (optional, multiple selection possible) Measuring point (day), see additional spec. To obtain a valid order code, simply append the optional features to the order code. If you have any questions, please contact your sales center. Scope of delivery The scope of delivery comprises: 1 sensor (version as per nameplate) 1 socket key 1 Operating Instructions 8 Endress+Hauser

Accessories In the following sections, you find the accessories available at the time of issue of this documentation. For information on accessories that are not listed here, please contact your local service or sales representation. Assembly holder Maintenance kits Holder system Flexdip CYH112 for water and wastewater assembly Flexdip CYA112 Modular holder system for sensors and assemblies in open basins, channels and tanks The holder system CYH112 works for nearly any type of fixing - fixing on the floor, wall or directly on a rail. Material: stainless steel Ordering acc. to product structure (Technical Information TI430C/07/en) Membrane kit 2 membrane caps (with chloride only 1 membrane cap with crystal) Electrolyte Order numbers: Ammonium: 71072574 Nitrate: 71072575 Potassium: 71072576 Chloride: 71072577 Maintenance kit for chloride electrode Sandpaper Electrolyte Order number: 71085727 Electrodes Ion-selective electrode Electrode, complete, length 120 mm Order numbers: Ammonium: 71109938 (color identification red) Nitrate: 71109937 (color identification blue) Potassium: 71109936 (color identification yellow) Chloride: 71109939 (color identification green) ph electrode with reference Order number: CPS11-1AT2GSA Temperature sensor Order number: CTS1-A2GSA Dummy electrode Order number: 71123812 Standard solution Ammonium, nitrate, potassium and chloride Standard solution 1 Ammonium nitrate, 1 molar 2 Potassium chloride, 1 molar Container size A 250 ml (8.45 fl.oz.) Transport documents 1 Standard documents 2 Incl. dangerous goods sheets 3 Safety data sheet Certificate A None B Manufacturer's certificate CAY40- Complete order code Endress+Hauser 9

ph High-quality buffer solutions of Endress+Hauser - CPY20 The secondary buffer solutions have been referenced to primary reference material of the PTB (German Federal Physico-technical Institute) and to standard reference material of NIST (National Institute of Standards and Technology) according to DIN 19266 by a DKD (German Calibration Service) accredited laboratory. ph value A ph 2.00 (accuracy ± 0.02 ph) C ph 4.00 (accuracy ± 0.02 ph) E ph 7.00 (accuracy ± 0.02 ph) G ph 9.00 (accuracy ± 0.02 ph) I ph 9.20 (accuracy ± 0.02 ph) K ph 10.00 (accuracy ± 0.05 ph) M ph 12.00 (accuracy ± 0.05 ph) Quantity 01 20 x 18 ml (0.68 fl.oz) only buffer solutions ph 4.00 and 7.00 02 250 ml (8.45 fl.oz) 10 1000 ml (0.26 US gal) 50 5000 ml (1.32 US gal) canister for Topcal S Certificates A Buffer analysis certificate Version 1 Standard CPY20- complete order code Compressed air cleaning Not suitable for continuous operation! Operating interval: max. 3 minutes cleaning, break for at least six times the cleaning time. Avoid condensation in the pressurized hoses. Cleaning unit in the housing 230 V or 115V, IP 65 Conveying rate at atmospheric pressure: 50 l/min (13.2 gal/min) Power consumption: 240 W Current consumption: 1.3 A Overheating protection: automatic switch off at T > 130 C (266 F) Order no. 230 V: 71072583 115 V: 71096199 Hose reducer coupling AD 8/6 mm: 71082499 10 Endress+Hauser

Endress+Hauser 11

Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI491C/07/EN/01.11 71130404 FM6