LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Similar documents
Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

LC-MS/MS Analysis of Phytocannabinoids and their

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Fast methods for the determination of ibuprofen in drug products

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Determination of urea in ultrapure water by IC-MS/MS

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

LC Technical Information

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Determination of trace anions in concentrated hydrofluoric acid

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

Tecan AC Extraction Plate

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Figure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

HILIC Method Development in a Few Simple Steps

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Optimizing a Generic Approach to Analyzing PPCPs in River Water

[ Care and Use Manual ]

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Appendix II- Bioanalytical Method Development and Validation

Analysis of Tobacco Alkaloids

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

A Simple SPE Method for the Determination of Malachite Green, Crystal Violet and Other Synthetic Dyes in Seafood

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Transcription:

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core Enhanced Technology, solid core Abstract A liquid chromatography-tandem mass spectrometry method for the determination of diclofenac in human plasma was developed. Using Thermo Scientific SOLA cartridges and plates, sample preparation was fast and efficient and gave excellent recovery levels for the compound. Separation was carried out using a Thermo Fisher Scientific Accucore RP-MS column with a cycle time of 1 minute. Good chromatographic peak shape and linearity over the dynamic range 1 to 1000 ng/ml was achieved. Introduction SOLA TM products revolutionize solid phase extraction (SPE). This first-in-class SPE product range introduces next generation, innovative technological advancements that give unparalleled performance compared to conventional SPE, phospholipid and protein precipitation products. This includes: Higher levels of reproducibility Higher levels of extract cleanliness Reduced solvent requirements Increased sensitivity SOLA products have significant advantages for the analyst when processing compounds in complex matrices, particularly in high-throughput, bioanalytical and clinical laboratories where reduced failure rates, higher analysis speed and lower solvent requirements are critical. The increased performance gives higher confidence in analytical results and lowers cost without compromising ease of use or requiring complex method development. very low tailing. The tightly controlled 2.6 µm diameter of the Accucore particles results in much lower backpressures than typically seen with sub-2 µm materials. Diclofenac is a non-steroidal anti-inflammatory drug that is used in the treatment of post operative pain, rheumatoid arthritis and the chronic pain regularly associated with cancer (Figure 1). Diclofenac works by blocking the action of cyclo-oxygenase that produces prostaglandins in response to injury, which subsequently results in pain and inflammation. Diclofenac is marketed under many brand names which include, Voltarol, Diclomax SR and Dicloflex. Accucore TM HPLC columns use Core Enhanced Technology to facilitate fast and highly efficient separations. The 2.6 µm diameter particles are not totally porous but have a solid core and a porous outer layer. The optimized phase bonding creates a series of high-coverage, robust phases. Accucore RP-MS uses an optimized alkyl chain length for more effective coverage of the silica surface. This coverage results in a significant reduction in secondary interactions and highly efficient peaks with

2 The extraction of diclofenac from human plasma is demonstrated in this application. Cl NH Cl OH O Figure 1: Diclofenac Experimental Details Consumables Fisher Scientific LCMS grade water W/011217 Fisher Scientific LCMS grade methanol M/4062/17 Fisher Scientific LCMS grade acetonitrile A/0626/17 Fisher Scientific Analytical grade acetic acid A/0360/25 Thermo Scientific National Mass Spec Certified 2 ml clear vial with blue bonded PTFE silicone cap MSCERT4000-34W Sample Handling Equipment Thermo Scientific 96 well plate vacuum manifold 60103-351 Thermo Scientific UltraVap sample evaporator CLS-229070 Sample Pretreatment A standard spiking solution (diclofenac) was prepared in water. A working internal standard solution (diclofenac-d4) was also prepared in water. A 200 µl sample of blank human plasma was taken. For standards and quality control (QC) samples, 10 µl of standard spiking solution was added. For all other samples, 10 µl of water was added. For standards and QCs, 10 µl of working internal standard solution was added; for blanks, 10 µl of water was added. Then, 200 µl of 70% formic acid in water was then added to the spiked samples and mixed well. Sample Preparation Compound(s): Matrix: Diclofenac, Diclofenac d4 (IS) Human plasma Cartridge/plate type: Thermo Scientific SOLA 10 mg/1 ml 60309-001 Conditioning stage: Application stage: Washing stage: Elution stage: Additional stage: 0.5 ml methanol then 0.5 ml water Apply all of the spiked sample 200 µl 90:10 (v/v) water / methanol 2 x 200 µl acetonitrile Dry down under nitrogen at 40 C and reconstitute in 100 µl 50:50 (v/v) water/ acetonitrile. Mix well. Separation Conditions Instrumentation: Thermo Scientific Accela 600 UHPLC Column: Accucore RP-MS 2.6 µm, 50 x 2.1 mm 17626-052130 Mobile phase A: Water + 0.1% acetic acid Mobile phase B: Acetonitrile + 0.1% acetic acid Gradient: 50% 100% B in 1 minute Flow rate: 0.6 ml/min Column temperature: 40 C Injection details: 20 µl Injection wash solvent 1: 80:20 (v/v) water / acetonitrile Injection wash solvent 2: 45:45:10 (v/v/v) IPA / acetonitrile / acetone

MS Conditions Instrumentation: Thermo Scientific TSQ Vantage MS Ionization conditions: HESI Polarity: Negative Spray voltage: 3000 V Vaporizer temp: 300 C Sheath gas pressure: 65 arb Aux gas pressure: 30 arb Capillary temp: 210 C Collision pressure: 1.5 mtorr Scan time: 0.05 s Q1 (FWHM): 0.7 Q3 (FWHM): 0.7 Compound transitions: Table 1 3 Compound Diclofenac Diclofenac-d 4 Parent (m/z) 250.1 254.1 Products (m/z) 178.0 214.0 217.0 Collision energy (V) 25 19 21 S-lens (V) 113 113 120 Table 1: Compound transition details Data Processing Software: Thermo Scientific LCQuan Results Extracted diclofenac standards from human plasma gave a linear calibration curve over the dynamic range of 1 to 1000 ng/ml with an r 2 coefficient of 0.999 (Figure 2 and Table 2). The chromatography of the LOQ at 1 ng/ml is shown in Figure 3. QC samples were run in replicates of six at a concentration of 15 ng/ml. The precision of the QC level was <4.4% CV (Table 3). Overspikes were run in triplicate at a concentration of 15 ng/ml and used to calculate the percentage recovery level for diclofenac of 85.8% (Table 4). 3.0 2.5 Area Ratio 2.0 1.5 1.0 0.5 0.0 0 200 400 600 800 1000 ng/ml Figure 2: Diclofenac linearity over the dynamic range 1 to 1000 ng/ml

4 Specified (ng/ml) Calculated %Diff S1 1 1.17 17 S1 1 0.906-9 S2 10 9.36-6 S3 25 24.8-1 S4 50 49.7-1 S5 100 99.0-1 S6 500 509 2 S7 750 746-1 S8 1000 993-1 S8 1000 1000 0 Table 2: Accuracy data for eight extracted diclofenac standards over the linear range 1 to 1000 ng/ml 100 90 80 70 Relative Abundance 60 50 40 30 20 10 0 0.0 0.5 1.0 1.5 2.0 2.5 Time (min) Figure 3: Representative chromatogram of diclofenac SRM, extracted from human plasma at 1 ng/ml (ng/ml) Average Calculated (n=6) Average %Diff Precision (%CV) QCL 15 14.7-2 4.4 Table 3: Average precision data for six replicate QCs for diclofenac Response (n=3) % Recovery Average QCL area response 10629.1 Average overspike area response 12382.4 86 Table 4: Recovery data for diclofenac

Conclusion SOLA SPE cartridges or plates in combination with Accucore RP-MS columns allow for a simple extraction and quantification of diclofenac from human plasma using an internal standard. An LOQ of 1 ng/ml for diclofenac in plasma was achieved. The extraction recovery was >86%. The method showed excellent precision with a %CV (n=6) <5%. Application Note 20569 thermoscientific.com/chromatography 2012 Thermo Fisher Scientific Inc. All rights reserved. Voltarol is a registered trademark of Novartis AG. Diclomax is a registered trademark of kogen Limited. Dicloflex is a registered trademark of Dexcel Limited. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. USA and Canada +1 800 332 3331 France +33 (0)1 60 92 48 34 Germany +49 (0) 2423 9431 20 or 21 United Kingdom +44 (0)1928 534110 Japan +81 3 5826 1615 AN20569_E 08/12S China +86 21 68654588 +86 10 84193588 +86 20 83145199 800 810 5118 India +91 22 6742 9494 +91 27 1766 2352 Australia 1 300 735 292 (free call domestic) New Zealand 0800 933 966 (free call domestic) All Other Enquiries +44 (0) 1928 534 050 Technical Support North America +1 800 332 3331 Outside North America +44 (0) 1928 534 440