Thin Layer Chromatography

Similar documents
Laboratory Exercise: Chromatographic Separation

Thin Layer Chromatography

THIN LAYER CHROMATOGRAPHY

CHEMICAL SEPARATION EXPERIMENT 2

Chromatography Lab # 4

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed

Experiment Nine Thin Layer Chromatography

Exercise 4: Thin layer chromatography of organic compounds

Experiment 1: Thin Layer Chromatography

Exp 1 Column Chromatography for the Isolation of Excedrin Components. Reading Assignment: Column Chromatography, TLC (Chapter 18)

Physical Separations and Chromatography

Practical 1 Procedure Iron by Titrimetry

Chromatography Extraction and purification of Chlorophyll CHM 220

Is There a Chemist in You?

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

Experiment 1: Extraction and Thin Layer Chromatography

3. Separation of a Mixture into Pure Substances

Experiment 1: The Borohydride Reduction of 9-Fluorenone to 9-Fluorenol

What s In That Pill?

Separations: Chromatography of M&M and Ink Dyes

Name Period Date. Lab 10: Paper Chromatography

PROGRAMMING THE RINSE ROBOT INTRODUCTION

not to be republished NCERT THE technique of chromatography is vastly used for the separation, Chromatography UNIT-5 EXPERIMENT 5.

For Chromatography, you might want to remember Polar Dissolves More, not like dissolves like.

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Chromatography and Functional Group Analysis

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

LIQUID CHROMATOGRAPHY

Principles of Thin Layer Chromatography

36B-BioOrganic Modifications for Technique Experiments. Technique of Thin-Layer Chromatography

Introductory Remarks:

LAB #6 Chromatography Techniques

Chromatography & instrumentation in Organic Chemistry

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

Manual Accompanying The GPHF-Minilab

Coordination Complexes

ARTEMETHER AND LUMEFANTRINE ORAL SUSPENSION:Final text for addition to The International Pharmacopoeia (November 2008)

Coordination Complexes

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

PURPOSE: To separate the pigments of spinach by Column Chromatography. To analyze Column Chromatography fractions by Thin Layer Chromatography.

Ester Synthesis And Analysis: Aspirin and Oil of Wintergreen. Vanessa Jones November 19, 2015 Thursday 8:30 Lab Section Lab Partner: Melissa Blanco

Chromatography What is it?

Chromatography. Investigation Photosynthetic Pigments. Do all leaves contain the same pigments?

Experiment 8 Synthesis of Aspirin

To explore solubilities and reactivities of different metal ions. To identify ions present in unknown solutions using separation methods.

Lab.2. Thin layer chromatography

General Chemistry I CHEM-1030 Laboratory Experiment No. 2 Physical Separation Techniques

Volumetric Analysis. Quantitative analysis answers the second question

Minneapolis Community and Technical College. Separation of Components of a Mixture

University of Wisconsin Chemistry 524 Introduction to Separations Methods *

Lab 10 Guide: Column Chromatography (Nov 3 9)

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

Chemical Reactions: The Copper Cycle

Stationary phase: Non-moving phase that provides support for mixture to move.

Thin Layer Chromatography

Experiment 7: Titration of an Antacid

Chemistry Gas Chromatography: Separation of Volatile Organics

LUMEFANTRINUM LUMEFANTRINE

This method describes the identification of the following prohibited colorants in cosmetic products:

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Separation of the Components of a Mixture

CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY

By the end of this experiment the student should have learned:

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

Thin Layer Chromatography

Chemistry 151 Lab 4: Chromatography

Laboratory Exercise: Synthesis of Zinc Iodide

CHROMATOGRAPHY A PROJECT IN CEHMISTRY. Chromatography includes various experimental techniques Designed to separate mixture of

Abstract. Introduction

Chromatography. What is Chromatography?

CHROMATOGRAPHY, AND MASS SPECTRAL. FRACTIONS OF Lasianthus

Substances and Mixtures:Separating a Mixture into Its Components

Chromatography 1 of 26 Boardworks Ltd 2016

Lab #5 - Limiting Reagent

Paper Chromatography Lab. Prepared for: Mrs. Freeman

2. Synthesis of Aspirin

Plop Plop, Fizz Fizz, Oh What A Relief It Is (Which Pain Reliever Works Fastest)

Chromatography. writing in color

Experiment 6: Dehydration of 2-Methylcyclohexanol

IDENTIFICATION TESTS FOR DURACOR TABLETS

EFAVIRENZ Final text for addition to The International Pharmacopoeia

To understand concept of limiting reagents. To learn how to do a vacuum filtration. To understand the concept of recrystallization.

Photosynthesis. Introduction

Plop Plop, Fizz Fizz, Oh What A Relief It Is (Which Pain Reliever Works Fastest)

To determine relative oxidizing and reducing strengths of a series of metals and ions.

Part II. Cu(OH)2(s) CuO(s)


PAPER AND THIN LAYER CHROMATOGRAPHY (TLC)

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

MIXTURES, COMPOUNDS, & SOLUTIONS

Chemical Reactions of Copper and Percent Recovery

Exp t 125. Oxidation of Borneol to Camphor. Reduction. Camphor. Borneol. Isoborneol

GRAVIMETRIC ANALYSIS OF A CHLORIDE SALT. REFERENCES: Nelson, J., Chemistry: The Central Science, 3 rd edition, Prentice-Hall, 1985

25. Qualitative Analysis 2

SEPARATION TECHNIQUES

EXPERIMENT 20. Solutions INTRODUCTION

Experiment 2: Analysis of Commercial Bleach Solutions

á1064ñ IDENTIFICATION OF ARTICLES OF BOTANICAL ORIGIN BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY PROCEDURE

Transcription:

Thin Layer Chromatography Thin-layer chromatography involves the same principles as column chromatography, it also is a form of solid-liquid adsorption chromatography. In this case, however, the solid adsorbent is spread as a thin layer (approximately 250 um) on a plate of glass or rigid plastic. A drop of the solution to be separated is placed near one edge of the plate, and the plate is placed in a container, called a developing chamber, with enough of the eluting solvent to come to a level just below the "spot." The solvent migrates up the plate, carrying with it the components of the mixture at different rates. The result may then be a series of spots on the plate, falling on a line perpendicular to the solvent level in the container (see, for example, the following Figure). The retention factor (Rf) of a component can then be measured as indicated in the figure below. This chromatographic technique is very easy and rapid to perform. It lends itself well to tine analysis of mixture composition and may also be used to advantage in determining the best eluting solvent for subsequent column chromatography. However, it should be borne in mind that volatile compounds (bp < 100EC) cannot be analyzed by TLC. The same solid adsorbents used for column chromatography may be employed for TLC; silica gel and alumina are the most widely used. The adsorbent is usually mixed with a small amount of "binder"--for example, plaster of Paris, calcium sulfate, or starch--to ensure adherence of the adsorbent to the plate. The plates may be prepared before use, or commercially available prelayered plastic sheets may be used. In either case, the plates or sheets should be dried for an hour or more in an oven at 110EC before use. This procedure removes moisture that is adsorbed on the adsorbent and produces a surface that is more effective in adsorbing and separating the components of the mixture being analyzed. The relative eluting abilities of the various solvents

that may be used are the same as given in Section 6.1 of your text. It should be remembered that the eluting power required of the solvent is directly related to the strength of adsorption of the components of the mixture on adsorbent. A distinct advantage of TLC is the very small quantity of sample required. A lower limit of detection of 10-9 g is possible in some cases. The spot of sample must be applied to the plate with care; it should not be large, for the same reason that the amount of sample placed at the top of a column should not be too large. However, larger samples such as 0.5 mg may be used on larger TLC plates, which have thicker coats of adsorbent. In these cases isolation of the components may be achieved by scraping the separated spots from the plate and eluting (extracting) them with an appropriate solvent. It is usually necessary to repeat this process a number of times in order to obtain even several milligrams of material. Such a procedure would offer a method of identification of the various components, however, because enough material could be collected to allow spectra to be obtained. Often it is useful for the purpose of identification to run TLC chromatograms of knowns and unknowns side by side. Other useful applications involve running multiple aliquots of samples collected from a chromatographic column or samples taken from a reaction mixture in order to follow reaction progress as a function of time. Detection of spots on the chromatogram is easy for colored materials, and a number of procedures are available for locating spots of colorless materials. For example, irradiation of the plate with ultraviolet light will permit location of the spots of compounds that fluoresce. Alternatively, the solid adsorbent may be impregnated with an otherwise inert, fluorescent substance. Spots of materials that absorb ultraviolet light but do not fluoresce will show up as black spots against the fluorescing background when the plate is irradiated with ultraviolet light. Other detecting agents are more often used. These agents may be sprayed onto the chromatograms, causing the spots to become readily apparent. Examples of detecting agents used in this way are sulfuric acid, which causes many organic compounds to char, and potassium permanganate solution. Iodine is another popular detecting agent. In this case the plate is placed in a vessel whose atmosphere is saturated with iodine vapor. Iodine is adsorbed by many organic compounds, and their spots on the chromatogram become colored (usually brown). Since these spots usually fade, it is a good idea to circle the spots with a pencil while they are still visible in order to have a permanent record of the chromatogram. Under a given set of conditions (adsorbent, solvent, layer thickness, and homogeneity) the rate of movement of a compound with respect to the rate of movement of the solvent front, R f, is a property of that compound. The value is determined by measuring the distance traveled by a substance from a starting line in the before-mentioned figure. The property has the same significance as retention time in a GC experiment. A. Thin-Layer Chromatography: General Instructions Place a TLC strip ("Bakerflex" brand or equivalent) on a paper towel on the bench surface. Handle the strip by the edges only and be sure the coated side is up. Two coatings are available: Aluminum Oxide IB-F and Silica Gel IB-F. (IB stands for inorganic binder, and

F means that the coating contains a fluorescent indicator.) At the top of the strip write the letter A or S (to identify the adsorbent); also identify the solvent to be used for development (e.g., 1:3 EA/C for 25% ethyl acetate - 75% cyclohexane). Dip a Strumia tube into the solution of the material to be analyzed and then very carefully touch the end of the vertically held capillary tube to the strip at a point about 10 mm from the bottom edge. Immediately make a mark at the side of the strip in line with the center of the spot. Allow the solvent to evaporate completely from the spot. Waving the strip gently in the air hastens the evaporation. Obtain a 4-oz. round screw-cap bottle, containing a whole or half disk of 7-cm filter paper. The cap should be Teflon or aluminum foil lined. Pour solvent into the bottle to a depth of no more than 5 mm. Cap the bottle tightly and shake it vigorously to saturate the space inside with the solvent vapor and to thoroughly wet the paper. Carefully place the strip (spotted end down) inside the bottle, and allow it to lean against the wall. Close the cap tightly and let the chromatogram develop. Do not disturb the bottle during the development. When the solvent front has reached a point about 1 cm from the top edge of the strip, carefully open the bottle and remove the strip. Immediately mark the position of the solvent front with a pencil. Wave the strip vigorously in the air to evaporate the solvent from the surface quickly. Examine the strip under ultraviolet light (in the special viewer) and outline with a pencil any spots that are detected. When you are finished, do not empty the 4-oz. round screw cap bottle. Cap the bottle tightly, see that it is properly labeled as to which solvent it contains, and return it to the storage area. B. Thin-Layer Chromatography: Analysis of a Commercial Analgesic Most non-prescription pain-relieving remedies contain aspirin (o-acetylsalicylic acid) or acetaminophen - and some contain both. Many also have some auxiliary compounds with analgesic properties. In addition, caffeine is included in some preparations. Caffeine is not an analgesic, but aids in the relief of certain types of headaches because of its stimulant effect (CNS and cardiac). You will receive as an "unknown" a tablet of a commercial analgesic, to be analyzed by TLC for the presence or absence of four specific constituents: acetaminophen, aspirin, phenacetin, and caffeine. Some of the products also have other active ingredients, but no attempt will be made to identify these other substances.

PROCEDURE Crush the tablet to a powder on a piece of glassine weighing paper. Put half of the powder in a 5 ml plastic beaker and add 2 ml of methanol and 1 ml of dichloromethane. Stir the mixture with a glass rod for about one minute to allow the solvent to extract the active ingredients. Allow the insoluble matter to settle. Carefully decant the supernatant liquid into a clean, dry 5-mL beaker. On a TLC strip coated with Silica Gel IB-F, apply a spot of the solution of "unknown" and two of the four known solutions. On a second Silica Gel strip, spot the "unknown" solution and the remaining two known solutions. Be sure to mark the identity of each spot on each strip. Develop each chromatogram in a bottle containing 100% ethyl acetate. Examine each strip under the ultraviolet light viewer (short wave UV light). Compare the spot positions (the Rf values) of the constituents of the tablet with those of the individual authentic substances. If very little movement of components has occurred on a strip, do not mark any visible spots with a pencil. Replace the strip in the bottle and repeat the development. Make a table recording the distance each substance moved from the origin and the distance the solvent moved.

Che 317 Sp 2005 Lab Report Title: Thin Layer Chromatography pp. 144-147 Name: Date: In the following table, enter the distance traveled by each spot, along with its' corresponding R f Sample Distance Front Traveled cm. Distance Component Traveled cm. Silica Gel TLC Plate in 100 % Ethyl Acetate Solvent Aspirin R faspirin Acetaminophen R facetominophen Caffeine R fcaffeine Phenacetin R fphenacetin 1 R f1 Unknown Tablet 2 3 R f2 R f3 4 R f4 The components in your tablet were (Justify your conclusions):