Circulation valves. An effective partner in the battle to prevent legionella.

Similar documents
Multifunctional Thermostatic Circulation Valve MTCV

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Cooling Water Flow Regulator

VD1 CLC. Small Valves DIN-range with a higher k v -value

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Calio-Therm NC Type Series Booklet

VK2 volume flow controller Overview

Compact Orifice FlowMeter

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.

Installation and User Instructions

product manual H-4204 Proving Ring Penetrometer

Electrical safety testing Checklist

Electronic pressure-independent characterised control valve EPIV

EPIV electronic pressure-independent characterised control valve EPIV

Elcometer 116C. Sling Hygrometer. Operating Instructions

Pressure independent balancing and control valve AB QM DN

Operating Instructions for Digital Manometer. Model: MAN-SD

Direct-operated 2/2-way solenoid valves Type EV210B

Elcometer 116A. Whirling Hygrometer. Operating Instructions

KENYA BUREAU OF STANDARDS (KEBS)

Pressure independent balancing and control valve AB QM DN

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

N) manual. Biomaster Operating manual

XR Analog Clock - Manual Setting Model Troubleshooting Guide

close to performances of the turbine gas meters designed for custody transfer measurements.

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

Pressure independent balancing and control valve AB QM DN

Type M4 - SON - SO - MS

Residual Chlorine Monitor

Lamp and Control Panel (Lamp Panel)

Installation guide 862 MIT / MIR

INTERNATIONAL STANDARD

Cold Weather Preparation

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

TECHNOLOGY IN MOTION MACO EMOTION HANDLES. A Sense of Elegance RHAPSODY

Presco AG. Standard Air Capacitor 10 nf / 2 kv. Type CL-0N10-K201. User's manual

flexible couplings for pipe repair

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Electrolyzed Water Treatment System for Commercial, On-Site and Indoor Use Only

CV3000 Series. Characterized Insert Control Valves

AN ECONOMICAL APPROACH TO AESTHETIC ROOFING

Food Safety and Quality Management System

THE DIAL PROFESSIONAL DUO DISPENSER

STATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION. Price: $5.00. Revised March 31, 1997

Eppendorf BioSpectrometer 6135/6136/6137

Spa & Wellness for Pipettes

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

POWER PUSHER Snowplow

Three-Way Mixing Valve. with or without presetting, for heating and cooling systems

Document category: There is no restriction on the circulation of this document

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Telecommunications Pipe

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

5SJ4...-.HG Circuit Breakers to IEC and UL 489

G-FIRE GROOVED FITTINGS

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals.

IL series. Centrifugal marine IN-LINE pumps

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

16 Appendix 16 Electrical Research Association Report

Standard Test Method for Thermal Conductivity of Refractories 1

Acknowledgment of Aramco Asia. Supplier Code of Conduct

Direct-operated 2/2-way compact solenoid valves Type EV210A

Accumulators Virginia KMP Suction Line Accumulators

K 080/12 F 10 K 3-2X/.. Features

Field Pro Operation and Installation Manual

Application Your benefits

KM-70 Panel-mounting Thermostat

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

INSTALLING TRAK SPORT TIRE CHAINS ON 20 MODEL 3 TIRES

IS YOUR BUSINESS PREPARED FOR A POWER OUTAGE?

GHS/ CHEMICAL RIGHT TO KNOW

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Air Handling Unit. Konvent

product manual H-3220A Benkelman Beam

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

SOUTHEAST TEXAS CONTINUING EDUCATION HIGH TEMPERATURE WATER HEATING SYSTEMS

Big 5 TH. The. Event THURSDAY. Why attend? Register today SEPTEMBER. FREE breakfast cobs and lunch provided. at Jewson Peterborough

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

INFRARED THERMOMETER Model : TM-959

Series P0 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1934, 1843 Rev. : C, D Rev. Date : 6/01, 10/2015

USER GUIDE AIR MINDER PLUS INDOOR AIR QUALITY/HEAT RECOVERY WHOLEHOUSE VENTILATION SYSTEMS FROM IMPORTANT: TO BE LEFT WITH END USER

NATURAL ROCK SAMPLE. Performance Monitoring Accessory for the RAD7 User Manual

Operator's Manual. optris BR 400. Calibration source

Dual laser + type K thermometer INFRARED THERMOMETER

SPECIFICATIONS PARTICLE SENSOR KS-28B Higashimotomachi, Kokubunji, Tokyo , Japan

Cooler-Bypass Thermostat Valve, Size 10

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Transcription:

An effective partner in the battle to prevent legionella.

Installation and maintenance Each Circulation Valve is delivered with a set of instructions.. Ensure that the circulation valve is installed with regard to the flow directional arrow on the valve body.. When using the Insulation jackets, ensure that there is enough space to allow for their fitting when the valve is in place.. The circulation temperature is selected by turning the numbered dial in line with the pointer on the valve mechanism.. The valve contains an isolating feature that is used when the thermal element needs to be inspected or replaced.. A drain valve is incorporated in the isolating valve; this in turn has a hollow stem that is used to house the bi metallic thermometer for temperature measurement. Circulation Valves are supplied without thermometers. These can be purchased separately as accessories. When servicing is completed, ensure that the insulation box is re fitted correctly. If there are significant pipe losses in the circuit then a valve of the next highest diameter may be used. Thermal Disinfection The valve mechanism is designed to allow for an increase in temperature above the maximum set position. This thermal disinfection mode permits hot water to circulate at temperatures above 70 C and may reach 7 C before re stabilizing at the pre-selected temperature. This high temperature disinfection will kill bacteria such as Legionella, but also presents a risk of scalding at the draw off outlets. It is strongly recommended that a risk assessment is carried out prior to thermal disinfection and duty of care exercised. Valve settings There is a choice of valves with different temperature ranges. Each one is preset at a default setting. The valves with a 0 C to C range of temperature settings are preset at approximately C and those with a 0 C to 0 C range are preset at approximately 7 C. The circulation valve can be adjusted to settings within these ranges by altering the dial position on the valve headwork. Pegler Yorkshire circulation valves incorporate a stop valve and drain valve unit. This allows for some flow adjustment via a manual control, as well as providing an isolating facility when repair or maintenance is required. The drain valve also allows for upstream pipe lengths to be drained for servicing. The hollow drain off spindle also allows for the fitment of the bi-metallic thermometer for temperature reading. Regulating cartridges are available as spares if required. Insulation jackets will need to be stored safely during servicing and then refitted after the valve has been adjusted and set at the correct commissioned temperature.

Introduction, features and benefits Domestic hot and cold water systems can, if not properly monitored and regulated by a circulation valve, be a breeding ground for the legionella bacteria. What is legionella bacteria? Legionella bacteria the cause of legionnaires disease occur naturally in the sources from which mains water is derived (namely lakes, rivers, surface and ground waters). In the UK the problem is most often associated with hot and cold water systems in hospitals, hotels and other large multi-outlet buildings. But domestic systems can also provide a breeding ground for the bacteria. This can then be transmitted into the occupants lungs through, for example, the water spray created by a shower. Circulation valves The Pegler thermostatically-controlled circulation valve is a powerful ally in the battle to defeat the health dangers posed by legionella. By automatically achieving thermal balancing and high-temperature disinfection of the hot water system, it denies the bacteria the optimum conditions for growth (between -ºC). Then there are other significant benefits, including system protection against the build-up of limescale, preventing scalding, and helping to minimise both hot water costs and water consumption. Pegler is a brand long associated with the many market-leading qualities for which the Pegler Yorkshire name and reputation are renowned throughout the world. Features DIN-DVGW approved. For warm water circulation pipes according to DVGW norm W, W and W. Medium touching parts made of bronze. Automatic thermal disinfection in the temperature ranges above ºC. Maximum flow rate over a separate valve cone adjustable and lockable. Range also includes thermometer and insulation jackets. Control handwheel for temperature adjustment Thermometer Body of bronze Handle element for regulating and lock spindle Control cartridge Stop and drain unit Regulating and lock spindle

Product range Circulation valve without insulation Pattern Description A B C D E F G Order Code Price P0 DN fxf 0-0 C 7 7. 9 /" - 00.09 P0 DN 0 fxf 0-0 C 7 7 7 /" - 0. P0 DN fxf 0-0 C 7 7. 9 /" - 0.09 P0 DN 0 fxf 0-0 C 7 7 7 /" - 0. P0 DN fxf 0-0 C 7 7. 0 " - 0 9. P0 DN mxm 0-0 C 7 7. 9 - /" 0.09 P0 DN 0 mxm 0-0 C 7 7 0 - /" 0. P0 DN mxm 0-0 C 7 7. 9 - /" 07.09 P0 DN 0 mxm 0-0 C 7 7. 0 - /" 0. P0 DN mxm 0-0 C 7 7 0. - " 09 9. A B C Rg D E F G Circulation valve regulation cartridge Pattern Description Order Code Price PCV DN 0-0 C 0 7. PCV DN 0 0-0 C 7.97 PCV DN 0-0 C 7. PCV DN 0 0-0 C 7.97 PCV DN 0-0 C 9. Insulation jacket Description A B C D E Order Code Price For circulation valve DN 7 For circulation valve DN 0 90.09 For circulation valve DN 7 0 7.7 A Rg D E C Accessories B Description Order Code Price Bimetallic thermometer Stop and drain unit 9.9

Performance and flow charts Technical data Maximum operating temperature: 90 C Maximum admissible operating pressure: bar Nominal width: DN /DN 0/DN Design: sleeve/sleeve or external thread/external thread : 0 C - 0 C 0 C - 0 C Default setting: approx. C approx. 7 C Thermal disinfection: > C DN circulation valves Flow chart for DN circulation valves 0 C - 0 C (according to DVGW VP ) and control range 0 C - 0 C 0 (mws) 0. 0. 0. 0. (bar) 0. 0.0 0.0 0.0 0.0 0.0 Maximum flow values with manual adjustment via stop spindle in number of turns from closing point. /U /U /U /U U /U U max. 00 0 0 0 0 0 0 (kpa) 0 Kv-value is based on a working installation with water temperature between C and 7 C....0 0 C-0 C 0. 0.0 0.0 Minimum flow Kv min = 0. 0 0 0 0 0 0 00 00 00 0000 00000 Flow in disinfection mode Kv TD = 0. Max flow at temperatures less than 0 C or 0 C Kv max =. Kv-Value DN0 circulation valves Kv-value is based on a working installation with water temperature between C and 7 C....0 0 C-0 C 0 0 0 0 70 7 0 Water temperature C 0 C-0 C Flow chart for DN0 circulation valves 0 C - 0 C (according to DVGW VP ) and control range 0 C - 0 C 0 (mws) 0. 0. 0. 0. (bar) 0. 0.0 0.0 0.0 0.0 0.0 Maximum flow values with manual adjustment via stop spindle in number of turns from closing point. /U /U /U U max. 00 0 0 0 0 0 0 (kpa) 0 Kv-Value 0 C-0 C 0 0 0 0 70 7 0 Water temperature C 0. 0.0 0.0 Minimum flow Kv min = 0. 0 0 0 0 0 0 00 00 00 0000 00000 Flow in disinfection mode Kv TD = Max flow at temperatures less than 0 C or 0 C Kv max =. Flow chart for DN circulation valves DN circulation valves Kv-value is based on a working installation with water temperature at 7 C. Kv-Value.....0 0 C-0 C 0 C - 0 C (according to DVGW VP ) 0 (mws) 0. 0. 0. 0. (bar) 0. 0.0 0.0 0.0 0.0 0.0 Maximum flow values with manual adjustment via stop spindle in number of turns from closing point. /U U U /U /U max. 00 0 0 0 0 0 0 (kpa) 0 0.0 0 0 0 0 70 7 0 Water temperature C 0. 0.0 0 0 0 0 0 0 00 00 00 0000 00000 Minimum flow Kv min = Flow in disinfection mode Kv TD = Max flow at temperatures less than 0 C Kv max =.

Our brands: Pegler technical helpline Tel 070 0 0 For sales information, please contact: UK regions Northern team Tel 070 0 0 Fax 00 00 Email north.sales@pegleryorkshire.co.uk Southern team Tel 070 0 0 Fax 00 0 Email south.sales@pegleryorkshire.co.uk Western team Tel 070 0 0 Fax 00 009 Email west.sales@pegleryorkshire.co.uk Eastern team Tel 070 0 0 Fax 00 0 Email east.sales@pegleryorkshire.co.uk Worldwide exports Tel + (0) 0 Fax + (0) 0 70 Email export@pegler.co.uk www.yorkshirefittings.co.uk Also available from Pegler Yorkshire: LUXURY TAP SOLUTIONS Pegler Yorkshire St. Catherine s Avenue, Doncaster, South Yorkshire, DN DF, England. Pegler. Registered Company No. 09 Yorkshire. Registered Company No. 00007 Place of Registration: England All brand names and logo styles are registered trademarks. Maintaining a policy of continual product development, Pegler Yorkshire Limited reserves the right to change specifications, design and materials of products listed in this leaflet without prior notice. LIT.REF: 009.09.0