Sodium Chloride - Analytical Standard

Similar documents
Sodium Chloride - Analytical Standard

Sodium Chloride - Analytical Standard

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

DRAFT EAST AFRICAN STANDARD

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Annex 2 Formaldehyde

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

National standard of People s Republic of China

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Cyanide, colorimetric, pyridine-pyrazolone

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Method for estimation of iodine in urine

GENERAL PHARMACOPOEIA MONOGRAPH

Carbonate content. SCAN-N 32:98 Revised White, green and black liquors and burnt lime sludge

Spectrophotometric Determination of Ferrocyanide in Effluents

INTERNATIONAL OLIVE COUNCIL

DR/4000 PROCEDURE LEAD. 2. The display will show: 3. Fill a 250-mL graduated cylinder to the 250-mL mark with sample.

Advanced Unit 7: Chemistry Practical Examination (SET A) Candidates must have: Scientific calculator Ruler

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

SPECIFICATION & TEST PROCEDURE SODIUM SALICYLATE Technical. Molecular weight : Reference : In-house

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

STANDARD METHODS FOR THE ANALYSIS OF OILS, FATS AND DERIVATIVES

Corn Syrup Analysis E-51-1 PHOSPHORUS

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

DR/4000 PROCEDURE CYANIDE. 1. Press the soft key under HACH PROGRAM. Select the stored program for cyanide by pressing 1750 with the numeric keys.

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

INTERNATIONAL OLIVE COUNCIL

METHOD 7B - DETERMINATION OF NITROGEN OXIDE EMISSIONS FROM STATIONARY SOURCES (ULTRAVIOLET SPECTROPHOTOMETRIC METHOD)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

GETTING THE END POINT TO APPROXIMATE. Two hours

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Test Method: CPSC-CH-E

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

Cadmium and lead content

Experiment 7A ANALYSIS OF BRASS

Cambridge International Examinations Cambridge Ordinary Level

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

METHANOL REFERENCE SPECIFICATIONS

SOIL ORGANIC CONTENT USING UV-VIS METHOD

Experiment # 9 : Cation Analysis: Group ( I )

Synthesis and Analysis of a Coordination Compound

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

Determination of Orthophosphate Ion

Starches and derived products Determination of sulfur dioxide content Acidimetric method and nephelometric method

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

CALCIUM (EGTA-Titrimetric)

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

The Synthesis and Analysis of Aspirin

Methods of test for bromide for industrial use

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Standard Methods for the Examination of Water and Wastewater


--> Buy True-PDF --> Auto-delivered in 0~10 minutes. NY/T Translated English of Chinese Standard: NY/T

Reference method for the determination of real alcoholic strength by volume of spirit drinks of viti-vinicultural origin: measurement by pycnometry

EXPERIMENT NINE Part I - The Standardization of Thiosulfate Solutions

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

9. Determination of the solubility product of KIO 4 and an investigation of the common ion effect Student Sheet

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

ASPARTAME. Not less than 98% and not more than 102% on the dried basis. White, odourless, crystalline powder, having a strong sweet taste

Coal - Determination of nitrogen - Semi-micro Kjeldahl method. Kol - Bestämning av kvävehalt - Semimicrometod enligt Kjeldahl

THE CATHOLIC UNIVERSITY OF EASTERN AFRICA A. M. E. C. E. A

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

C q T q C T. Heat is absorbed by the system H > 0 endothermic Heat is released by the system H < 0 exothermic

For this lab, you will determine the purity of the aspirin by titration and by spectrophotometric analysis.

TECHNICAL BRODIFACOUM

#30 Thermochemistry: Heat of Solution

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

SIDE BY SIDE COMPARISON TABLE FOR HACH METHOD NUMBER COLORIMETRIC DETERMINATION OF CYANIDE

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT


PHYSICAL SCIENCE 0652/5

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

IMPCA METHANOL REFERENCE SPECIFICATIONS

Practical 1 Procedure Iron by Titrimetry

Determination of Orthophosphate Ion

Transcription:

Sodium Chloride - Analytical Standard Determination of Arsenic Former numbering: ECSS/CN 312-1982 & ESPA/CN-E-105-1994

1. SCOPE AND FIELD OF APPLICATION The present EuSalt Analytical Standard describes a silver diethyldithiocarbamate photometric method for the determination of arsenic in sodium chloride. The method is applicable to products of arsenic content (As) equal to or greater than 0.1 mg per kilogram of salt. 2. REFERENCE International Standard ISO 2590 General method for the determination of arsenic - Silver diethyldithiocarbamate photometric method. 3. PRINCIPLE (see 9.4.) Dissolution of the sample in hydrochloric acid. Reduction of arsenic by zinc in a hydrochloric acid medium with formation of arsine (AsH 3 ) and absorption of the arsine in a solution of silver diethyldithiocarbamate in pyridine. Photometric measurement of the purplish-red colour produced by the colloidally dispersed silver at a wavelength around 540 nm. Note: colloidal silver is formed according to the following equation AsH 3 + 6 Ag(DDTC) 6 Ag + 3 H(DDTC) + As(DDTC) 3 4. REAGENTS Unless otherwise stated, use only reagents of recognized analytical grade and only distilled water or water of equivalent purity. All the reagents, and the zinc in particular, shall be free from arsenic or have a very low arsenic content. 4.1. Pyridine, ρ 0.980 g/ml WARNING : Because of the hazardous properties of pyridine, it is recommended to handle with care and in a well-ventilated fume cupboard. 4.2. Zinc pellets, 3-8 mm or any other form of zinc Note: when zinc is used in any other form than pellets, ensure that the rate and time of evolution of hydrogen are sufficient to reduce and expel all arsenic present as arsine. 4.3. Hydrochloric acid, ρ 1.19 g/ml, 37% (m/m) 4.4. Silver diethyldithiocarbamate, 5 g/l solution in pyridine Dissolve 1 g of silver diethyldithiocarbamate [Ag(DDTC)] in pyridine (4.1.) and dilute to 200 ml with pyridine. This solution remains stable for about 2 weeks, if stored in a tightly sealed dark glass bottle and protected from light. 4.5. Potassium iodide solution, β (KI) 100 g/l Store this solution in a dark bottle. 4.6. Tin(II) chloride solution, β (SnCl2. 2H2 O) 400 g/l Dissolve 40 g of tin (II) chloride dihydrate in a mixture of 25 ml of water and 75 ml of hydrochloric acid (4.3.). 4.7. Arsenic, stock solution I, β (As) = 1000 mg/l, commercial standard solution or to be prepared as follows. Dissolve 1.320 g of arsenic trioxide, (As 2 O 3 ), in about 20 ml of sodium hydroxide solution (50 g/l solution). Make up to 1000 ml in a one-mark volumetric flask and mix. 4.8. Arsenic, stock solution II, β (As) = 2.50 mg/l Transfer 2.50 ml of arsenic stock solution I (4.7.) into a 1000 ml one-mark volumetric flask, make up to the mark and mix. Prepare this solution just before use.

4.9. Absorbent cotton wool, saturated with lead acetate Dissolve 20 g of lead acetate trihydrate, Pb(C 2 H 3 O 2 ) 2. 3H2 O, in 100 ml of water. Saturate the absorbent cotton wool with this solution, remove the excess solution by allowing it to drain and dry the cotton wool under vacuum at room temperature. Store it in an airtight container. 5. APPARATUS Usual laboratory equipment (see 9.2.) and: 5.1. Glass apparatus, with ground glass joints, for the liberation and absorption of arsine A suitable apparatus is shown in the figure in the appendix and includes: 5.1.1. Conical flask, 100 ml capacity 5.1.2. Connecting tube 7.2. Test solution Transfer the test portion (7.1.), 50 ml of water and 10 ml of hydrochloric acid (4.3.) into a 100 ml conical flask (5.1.1.). 7.3. Blank solution Add 50 ml of water and 10 ml of hydrochloric acid (4.3.) into a 100 ml conical flask (5.1.1.). 7.4. Calibration 7.4.1. Calibration solutions These preparations are used for photometric measurement in cuvettes of 1 cm optical path length. Transfer the volumes of arsenic stock solution II (4.8.) indicated in the following table into a series of six 100 ml conical flasks (5.1.1.). Add 10 ml of hydrochloric acid (4.3.) and the quantity of water necessary to make up to about 60 ml. 5.1.3. Absorption vessel with 15 bulbs 5.2. Spectrophotometer or 5.3. Photocolorimeter fitted with a filter ensuring maximum transmission between 520 and 560 nm. Note: Specify the type of apparatus used (spectrophotometer or photocolorimeter), the path length and the wavelength (or type of filter). 6. SAMPLING AND SAMPLES (see 9.1.) A test sample of about 500 g should be taken for analysis, ensuring that it is representative of the whole batch. 7. PROCEDURE (see 9.1.) 7.1. Test portion Weigh, to the nearest 0.1 g, about 10 g of the test sample containing a maximum of 20 µg of As (see 9.3.). Calibration solution No. Arsenic stock solution II ml Corresponding mass of arsenic, µg 1(*) 0 0 2 1.0 2.5 3 2.0 5.0 4 4.0 10.0 5 6.0 15.0 6 8.0 20.0 (*) zero calibration solution 7.4.2. Reduction and colour development Proceed with each glass apparatus (5.1.) as follows. Place a little of the absorbent cotton wool (4.9.) in the connecting tube in order to absorb any hydrogen sulphide which may be released with the arsine (see figure).

Transfer 5.0 ml of silver diethyldithiocarbamate solution (4.4.) into the absorption vessel and attach the connecting tube to the absorption vessel by means of a safety clip. Proceed with the conical flask as follows. Add 3 ml of potassium iodide solution (4.5.) and 2 ml of tin(ii) chloride solution (4.6.), swirl and allow to stand for 15 minutes. Add 5 g of zinc (4.2.), if necessary with the aid of a powder funnel, and rapidly assemble the apparatus as indicated in the figure. Allow approximately 45 minutes for the reaction to take place. Detach the absorption vessel, swirl in order to disperse the formed red deposit and to mix. The colour of the solution is stable for about 2 hours in the absence of light, nevertheless, it is better to carry out the photometric measurements immediately. 7.4.3. Photometric measurements Adjust the apparatus to zero absorbance with pyridine (4.1.). Carry out the photometric measurements using a spectrophotometer (5.2.) set up at the maximum of absorption (wavelength around 540 nm) or a photocolorimeter (5.3.) fitted with the appropriate filter. 7.4.4. Calibration curve Subtract the absorbance of the zero calibration solution from that of each calibration solution and plot a graph showing the quantities of arsenic (As), in micrograms, added to the calibration solutions (7.4.1.) on the abscissa and the corresponding corrected absorbances on the ordinate. 7.5. Determination 7.5.1. Reduction and colour development Proceed with the test solution (7.2.) and the blank solution (7.3.) according to the procedure for calibration solutions described in paragraph (7.4.2.). 7.5.2. Photometric measurements Carry out the photometric measurements of the two solutions (7.5.1.) according to the instructions given in paragraph (7.4.3.). 8. EXPRESSION OF RESULTS 8.1. Evaluation The arsenic content of the sample, ω (As), of salt is given by the formula: where ω (As) ω (As) = m 1 - m 0 m is the arsenic content, in milligrams per kilogram of salt, m is the mass, in grams, of the test portion (7.1.), m 1 m 0 is the mass of arsenic, in micrograms, analysed for the test solution (7.2.), is the mass of arsenic, in micrograms, analysed for the blank solution (7.3.).

8.2. Repeatability and reproducibility Analyses, carried out on three samples by several laboratories, have given the following statistical results, each laboratory having furnished results obtained by the same operator performing two analyses per sample: 9. REMARKS 9.1. Ensure that no trace of arsenic is introduced during the sampling operations (e.g. by apparatus) or during the analysis. Number of laboratories after elimination of outliers Results, mg As/kg salt Rock salt Vacuum salt Sea salt 17 17 18 9.2. All the glass containers used for the determination of arsenic shall be washed with hot concentrated sulphuric acid, taking the necessary precautions, then rinsed thoroughly with water and dried in a drying cabinet. Mean*) 0.005 0.007 0.024 Standard deviation for: - repeatability (s r ) 0.0215 0.0236 0.0210 - reproducibility (s R ) 0.0340 0.0401 0.0506 *) Mean values are below Limit of Quantitation Reference: European Committee for the Study of Salt, ECSS/CN 287-1982, Statistical Study of Inter-Laboratory Analysis of Sodium Chloride (As, Cd, Hg, Pb) 9.3. In case of an arsenic content greater than 2 mg/kg of salt, the size of test portion (7.1.) must be reduced. Sodium chloride as a matrix does not influence the generation, evolution and determination of arsine. 9.4. Interferences of this method may be caused by nitrates, nitrites, antimony, mercury, chromium, cobalt, copper, molybdenum, nickel, platinum, silver and others. Generally there is no interfering effect at concentrations usually present in salt.

Page 6 of 6 Appendix Determination of arsenic - Typical apparatus A: 100 ml conical flask B: connecting tube C: absorbent cotton wool saturated with lead acetate D: absorption vessel with 15 bulbs (total volume of the bulbs : 14 ml)