DBS315 1-phase SIDE CHANNEL BLOWERS

Similar documents
ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz

G_Series. Gas Ring Blowers US Edition

Mechanical flow-rate controllers

variable flow dampers

Samos SI E1/E2

CNA-CNB. Centrifugal fans

VRF Technical Data Book

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000

Solenoid valves Type EVUL

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

CapaciTorr HV Pumps. making innovation happen,together

BNA Series. PLENUM FAN with Backward Wheels

VK2 volume flow controller Overview

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

Atlas Copco Air motors. A full range of compact, high performance air motors

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Digital AC Motors MHD

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

Calio-Therm NC Type Series Booklet

Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades. Issue 1.4 September 2013

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

CapaciTorr HV 200 HIGHLIGHTS

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Single Phase Motors Technical Datasheets

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

Technical Explanation for Axial Fans

TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 2017

Z7A. Load cells. Special features. Data sheet. Wiring code

I/IN (D) Kriva momenta i struje Torque and current curves Moment und Strom Kurven. - a / r

AE / AER Series. AER Series

Single Phase Motors Technical Datasheets

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications

Method of Measuring Machinery Sound Within an Equipment Space

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Contents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Direct-operated 2/2-way solenoid valves Type EV210B

3 Port, 2-Ton Outdoor Heat Pump

Fundamentals of silencing and their practical application in screw compressor plants

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

FAN TERMINOLOGY. t = 1.2 kg/m 3 (Standard air density at 20 C and 1013mb. V = duct air velocity, m/s.

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

ED 701 General Industry Pressure Transmitter

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

473 Dew Point Hygrometer

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

Multi-Speed Three-Phase Induction Motors

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014

Pumps type MP Motor pump combination for mounting into tanks for on/off service

Linear ceiling diffuser

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

The electronic actuator for future-proof applications

Type UB1 Load Cell. Option Stainless steel cable gland

Operating limits and tolerances of platinum resistance thermometers per EN 60751: 2008

792A AC/DC Transfer Standard

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

AC axial compact fan

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming

Air distribution systems. Adjustable radial outlet RA-V...

SPECIFICATION SHEET for APPROVAL

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

AC axial compact fan

DEBEM IM VERTICAL CENTRIFUGAL PUMPS.

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

I Ex d/e Switch- and Control-Equipment I

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Attenuation. Witt&Sohn AG Oct-14

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

KZPb

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

LES. Single-stage end-suction pumps Identification Type key

CMA - B - C - D - CMR

Transcription:

DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high compression of the internal air, resulting in a vacuum at the inlet and pressure at the outlet of the blower. This process works without any contact, thus eliminating wear and the need for lubrication. FEATURES compressor and vacuum pump in a single unit robust oil-free low noise levels low vibration levels maintenance free vertical mounting with in- / outlet pointing upwards possible integrated silencers many different applications DBS11 -phase BENEFITS high flow and high pressure out of a single phase voltage supply accurate performance curves allows engineering with smaller reserve capacity detailed sound level data for acoustic purposes Dutair blower motors are fitted with PTC thermistors as standard a variety of modifications possible for non-standard applications DBS GENERAL TECHNICAL DATA DBS15 1-phase DB 5 Hz 6 Hz bare shaft Power 1 kw 1.5 1. max. 1. Voltage 2 V 2 2 - Current Revolutions A /min 1. 11.4-277 1 1... Protection class IP IP PTC Thermistors 4 C Sound pressure 7 db(a) Weight kg 14 14-66.5 66.8-25 25 1 - n see notes on page 6 1 Modifications reserved 4716216

DBS15/ 1-phase PERFORMANCE Static pressure difference between in- and outlet p S against airflow Q at an ambient condition of 11 mbar and 2 C. All duty points on thermal equilibrium 8. Flow is rated in Nm /h defined as air, 11 mbar and C. Tolerance +/- %. See notes on page 6. 2 1 15 125 PRESSURE 1 max Δp S DBS15-1~ max Δp S DBS15-1~ 6 Hz 2 V 9 5 Hz 2 V Q [Nm /h] 5 25 +5 +1 +15 +2 +25 + +5 TEMPERATURE RISE Temperature rise T measured directly at in- and outlet. Ambient condition of 11 mbar and 2 C. All duty points on thermal equilibrium 8. Tolerance +/-5 C. 1 8 6 PRESSURE 4 ΔT [ C] 2 +5 +1 +15 +2 +25 + +5 POWER Motor power P delivered at i m p e l l e r s h a f t. A m b i e n t condition of 11 mbar and 2 C. All duty points on t h e r m a l e q u i l i b r i u m 8. Tolerance +/-5 %. Accurate data on current consumption for specific duty points available on request. 2. 1.5 1. PRESSURE P [kw].5 +5 +1 +15 +2 +25 + +5 Modifications reserved 2 4716216

DBS15/ 1-phase PERFORMANCE Static pressure difference between in- and outlet p S against airflow Q at an ambient condition of 11 mbar and 2 C. All duty points on thermal equilibrium 8. Flow is rated in Nm /h defined as air, 11 mbar and C. Tolerance +/- %. See notes on page 6. VACUUM 2 1 15 125 1 max Δp S DBS15-1~ max Δp S DBS15-1~ 6 Hz 2 V 9 5 Hz 2 V 5 25 Q [Nm /h] -5 - -25-2 -15-1 -5 TEMPERATURE RISE Temperature rise T measured directly at in- and outlet. Ambient condition of 11 mbar and 2 C. All duty points on thermal equilibrium 8. Tolerance +/-5 C. VACUUM 1 8 6 4 2 ΔT [ C] -5 - -25-2 -15-1 -5 POWER Motor power P delivered at i m p e l l e r s h a f t. A m b i e n t condition of 11 mbar and 2 C. All duty points on t h e r m a l e q u i l i b r i u m 8. Tolerance +/-5 %. Accurate data on current consumption for specific duty points available on request. VACUUM 2. 1.5 1..5 P [kw] -5 - -25-5 Modifications reserved 4716216-2 -15-1

DBS15/ 1-phase SOUND LEVEL PRESSURE DBS15 1-phase 7 6 5 4 2 6 125 25 5 1K 2K 4K 8K 7 6 5 5 Hz +7 mbar 66. db(a) 7 6 Hz + mbar 66.4 db(a) 7 4 2 6 125 25 5 1K 2K 4K 8K 7 6 5 4 2 6 125 25 5 1K 2K 4K 8K 7 6 5 SOUND LEVEL VACUUM DBS15 1-phase 5 Hz - mbar 66.7 db(a) 7 6 Hz -8 mbar 67. db(a) 7 4 2 6 125 25 5 1K 2K 4K 8K Modifications reserved 4 4716216

DBS15/ 1-phase DIMENSIONS DBS15 1-phase 22 4 1 256 6 17 1 OUTLET 12 154 174 INLET 58 225 2 11 71 9 152 6 DIMENSIONS DBS 22 4 259 6 24 5 4 12 154 17 OUTLET 174 INLET 58 225 2 11 71 9 152 6 all dimensions in mm except in- and outlet connection CAD models available in STEP format tolerance +/-2 mm in case of discrepancy between dimensional drawing and CAD model, dimensions in dimensional drawing take precedence Modifications reserved 5 4716216

DBS15/ 1-phase ORDERING INFORMATION 5 DB S 5 U...-.. ss HT RS FE IP56 Q G Ex C... Optional painting, standard RAL72 e.g. C: RAL Optional ATEX non-sparking version ATEX Ex II Cat G/D Ex-na Optional G: blower in gas-tight version available for single stage blowers Optional Q: anti condensation heating 2 V Optional motor protection: IP56 / IP, for IP56 specific mounting position Optional seal on motor shaft FE: PTFE seal / Vt: Viton seal Optional bearing material RS: Improved resistance against moisture Optional bearing lubrication14 HT: high temp. / LT: low temp. Optional bearing material ss: stainless steel Optional special motor voltage e.g. U5-5: 5 V at 5 Hz version Motor size Blower size S: Double stage serial blower P: Double stage parallel blower Dutair Blower 51: single phase / 5: three phase COMMENTS WARNING: Comparing performance data can be misleading. Dutair specifications are based on a thermal equilibrium 8 for all duty points along the characteristics curves in this document. Many commercial based flow characteristics curves defined as m³/h air at 2 C, 11 mbar(a) and +/-1 % tolerance but can be up to 4 % higher than accurate characteristics curves defined as Nm³/h air at C, 11 mbar(a), thermal equilibrium 8 duty points and +/- % tolerance as specified in this Dutair document. The performance measurements are executed with instruments calibrated by DNV KEMA and are traceable to primary and/or internationally accepted measurement standards. 1 Maximum shaft power allowed at continuous operation. Rated output electric motor in accordance with NEN-EN-IEC 64-1. 2 Allowed supply voltage tolerance 5 %. Consult your Dutair dealer for different supply voltages. Protection class in accordance with NEN-EN-IEC 64-5. 4 PTC thermistors connected in series fitted in main windings and auxiliary windings. 5 N/a. 6 N/a. 7 Free field equivalent continuous sound pressure level A-weighted L eq[db(a)]. Unless specified L eq[db(a)] rated at 5 % of maximum pressure at 5 Hz. Tolerance +/- 2 db(a). Conditions as note 1. 8 Thermal equilibrium is the state reached when the temperature rises of several parts of the machine as well as the temperature rise between in- and outlet do not vary by more than a gradient of 2 C per hour. 9 Operation at 2 V within range of 5 to 6 Hz. 1 N/a. 11 N/a. 12 Free field class 1 octave band measurements in accordance with IEC 6126 unweighted L p[db(z)]. Tolerance +/- 5 db(z). Conditions as note 1. 1 Measurements at 1 m distance with in- and outlet duct connected to the blower on a reflective surface. Class 1 sound level meter Delta Ohm HD21UC/A according to IEC 61672-1. Acoustic calibration prior to measurements with class 1 calibrator HD22ACC according to IEC 6942. 14 Standard ambient temperature range -2...+4 C. Modifications reserved 6 4716216