Mass spectrometry gas phase transfer and instrumentation

Similar documents
Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Macromolecular Chemistry

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Lecture 8: Mass Spectrometry

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

Lecture 8: Mass Spectrometry

Lecture 15: Introduction to mass spectrometry-i

Tendenze nell innovazione della strumentazione in spettrometria di massa:

LC-MS Based Metabolomics

Analysis of Polar Metabolites using Mass Spectrometry

MS Goals and Applications. MS Goals and Applications

TANDEM MASS SPECTROSCOPY

Mass Spectrometry. What is Mass Spectrometry?

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

MS Goals and Applications. MS Goals and Applications

Chemistry 311: Topic 3 - Mass Spectrometry

MASS SPECTROMETRY. Topics

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Qualitative Organic Analysis CH 351 Mass Spectrometry

Mass Spectrometry Course

GRADUATE COURSE IN MASS SPECTROMETRY: LECTURE 2

Mass Spectrometry in MCAL

Mass spectrometry.

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

M M e M M H M M H. Ion Sources

Types of Analyzers: Quadrupole: mass filter -part1

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

PC 235: Mass Spectrometry and Proteomics

Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory

Harris: Quantitative Chemical Analysis, Eight Edition

Translational Biomarker Core

CEE 772: Instrumental Methods in Environmental Analysis

1. The range of frequencies that a measurement is sensitive to is called the frequency

Molecular Mass Spectrometry

Chemistry Instrumental Analysis Lecture 37. Chem 4631

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

LECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

Atomic masses. Atomic masses of elements. Atomic masses of isotopes. Nominal and exact atomic masses. Example: CO, N 2 ja C 2 H 4

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Choosing the metabolomics platform

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Protein analysis using mass spectrometry

Mass Spectrometry. General Principles

Auxiliary Techniques Soft ionization methods

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Mass Spectrometry for Chemists and Biochemists

Mass Analyzers. Ion Trap, FTICR, Orbitrap. CU- Boulder CHEM 5181: Mass Spectrometry & Chromatography. Prof. Jose-Luis Jimenez

BIOINF 4399B Computational Proteomics and Metabolomics

Mass Spectrometry. Anders Malmendal. 1. Physical principles. Mass Spectrometry

Mass Spectrometry: Introduction

Ionization Techniques Part IV

Introduction to the Q Trap LC/MS/MS System

Chem 550, Spring, 2012 Part I: OVERVIEW OF MASS SPECTROMETRY:

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Introduction to LC-MS

Molecular Mass Spectrometry

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Computational Methods for Mass Spectrometry Proteomics

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Voyager-DE STR Biospectrometry Workstation Manufactured by PerSeptive Biosystems

CHROMATOGRAPHY AND MASS SPECTROMETER

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

What is a mass spectrum?

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

MS/MS .LQGVRI0606([SHULPHQWV

BST 226 Statistical Methods for Bioinformatics David M. Rocke. January 22, 2014 BST 226 Statistical Methods for Bioinformatics 1

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. MAGLAB Summer School Ryan P. Rodgers

Quattro Micro - How does it work?

Week 5: Fourier Tranform-based Mass Analyzers: FT-ICR and Orbitrap

Ch 13. Basics of Mass Spectrometry (I) : Principles & Ionization Sources

Mass Spectrometry. Electron Ionization and Chemical Ionization

Instrumentation development for coupling ion/ion reactions and ion mobility in biological mass spectrometry

Mass Spectrometry (MS)

MALDI-TOF: a powerful tool for the analysis of biomolecules and large organic molecules

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

LECTURE-13. Peptide Mass Fingerprinting HANDOUT. Mass spectrometry is an indispensable tool for qualitative and quantitative analysis of

Mass Spectrometry. A truly interdisciplinary and versatile analytical method

Basics of Mass Spectrometry

Finnigan LCQ Advantage MAX

Olumide Adebolu. Chromatographic Fidelity and Matrix /Analyte Solubility in Complex Polymer Systems using HPLC-MALD/I TOF MS

Part I Introduction to MS in bioanalysis

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS)

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

4. How can fragmentation be useful in identifying compounds? Permits identification of branching not observed in soft ionization.

BIOINF 4120 Bioinformatics 2 - Structures and Systems - Oliver Kohlbacher Summer Systems Biology Exp. Methods

Ion sources. Ionization and desorption methods

The Role of Multiple MS Technologies in Bioanalytical Analysis

1) In what pressure range are mass spectrometers normally operated?

Chapter 14. Molar Mass Distribution.

Chemistry Instrumental Analysis Lecture 35. Chem 4631

ICPMS Doherty Lecture 1

Ch. 22 Mass Spectrometry (MS)

Introduction to Mass Spectrometry

Transcription:

Objectives of the Lecture spectrometry gas phase transfer and instrumentation Matt Renfrow January 15, 2014 1. Make ions 2. Separate/Analyze 3. Detect ions 4. What is mass resolution and mass accuracy? Stable isotopes of most abundant elements of peptides Element Abundance H 1.0078 2.0141 99.985% 0.015 C 12.0000 13.0034 98.89 1.11 N 14.0031 99.64 15.0001 0.36 O 15.9949 16.9991 17.9992 99.76 0.04 0.20 Monoisotopic mass Monoisotopic mass corresponds to lowest mass peak When the isotopes are clearly resolved the monoisotopic mass is used as it is the most accurate measurement. 1

Average mass Average mass corresponds to the centroid of the unresolved peak cluster ISO:CH3 How is mass resolution calculated? M 15.0229 100 90 80 70 60 R = M/ M 100 nsity % Inten 50 FWHM = M 40 30 When the isotopes are not resolved, the centroid of the envelope corresponds to the weighted average of all the the isotope peaks in the cluster, which is the same as the average or chemical mass. 20 10 0 15.01500 15.01820 15.02140 15.02460 15.02780 15.03100 (m/z) Intensity (%) Two peptides - same nominal mass - simulation Peptide mixture: [Val 5 ]-Angiotensin II Lys-des-Arg 9 -Bradykinin Sequence: DRVYVHPF KRPPGFSPF Formula: C 49 H 69 N 13 O 12 C 50 H 73 N 13 O 11 Exact mass: [M2H] 2 = 516.76671 [M2H] 2 = 516.78490 m (mmu): 18.2 mmu 100 80 60 40 20 0 516.76671 (correct) RP = 18,000 516.77581 (observed) 516.78490 (correct) 516.65 516.70 516.75 516.80 516.85 516.90 m/z Intensity (%) 100 80 60 40 20 0 RP = 56,700 516.76671 516.78490 2 ppm (10) 516.65 516.70 516.75 516.80 516.85 516.90 m/z Is Accuracy Important? Results for error limit up to 5 ppm 1 ppm (4) 5 ppm (23) Theoretical Delta Delta RDB Composition [ppm] [mmu] 516.76671 0.0 0.0 21.0 C 49 H 71 O 12 N 13 516.76647 0.5 0.2 15.0 C 49 H 79 O 11 N 9 S 2 516.76638 0.6 0.3 12.0 C 41 H 75 O 14 N 15 S 1 516.76705-0.7-0.3 11.5 C 43 H 77 O 15 N 12 S 1 516.76604 1.3 0.7 16.0 C 48 H 75 O 16 N 9 516.76738-1.3-0.7 20.5 C 51 H 73 O 13 N 10 516.76604 13 1.3 07 0.7 21.5 C 47 H 69 O 11 N 16 516.76580 1.8 0.9 15.5 C 47 H 77 O 10 N 12 S 2 516.76772-2.0-1.0 16.5 C 44 H 73 O 11 N 16 S 1 516.76773-2.0-1.0 11.0 C 45 H 79 O 16 N 9 S 1 516.76805-2.6-1.3 25.5 C 52 H 69 O 9 N 14 516.76537 2.6 1.3 16.5 C 46 H 73 O 15 N 12 516.76807-2.6-1.4 7.0 C 38 H 79 O 14 N 15 S 2 516.76513 3.0 1.6 10.5 C 46 H 81 O 14 N 8 S 2 516.76513 3.1 1.6 16.0 C 45 H 75 O 9 N 15 S 2 516.76839-3.3-1.7 16.0 C 46 H 75 O 12 N 13 S 1 516.76479 3.7 1.9 20.0 C 52 H 75 O 11 N 9 S 1 516.76872-3.9-2.0 25.0 C 54 H 71 O 10 N 11 516.76470 3.9 2.0 17.0 C 44 H 71 O 14 N 15 516.76874-3.9-2.0 6.5 C 40 H 81 O 15 N 12 S 2 516.76446 4.3 2.2 11.0 C 44 H 79 O 13 N 11 S 2 516.76897-4.4-2.3 12.5 C 40 H 73 O 16 N 16 516.76907-4.6-2.4 15.5 C 48 H 77 O 13 N 10 S 1 2

error = theoretical mass - observed mass theoretical mass x 1,000,000 How does a mass spectrometer work? m/z = [ M nh] n m/z = [ M - nh] n Sample source: makes ions analyzer: separates ions spectrum: presents information Spectrometer Block Diagram High Vacuum System Spectrometer Block Diagram High Vacuum System Turbo molecular pumps Data source Analyzer System Data source Analyzer System 3

Sample Introduction Source High Vacuum System High Vacuum System Data Source Analyzer System Data Source Analyzer System HPLC Flow injection Charged vapor stream Sample plate MALDI ESI FAB LSIMS EI CI DART Nobel Prize in Chemistry- 2002 For getting proteins and peptides into the gas phase Sources make ions from sample molecules (s are easier to detect than neutral molecules.) Electrospray ionization: Pressure = 1 atm Inner tube diam. = 100 um Sample Nozzle (Lower Voltage) Partial vacuum N 2 MH John Fenn Koichi Tanaka "for the development of methods for identification and structure analyses of biological macromolecules" and "for their development of soft desorption ionisation methods for mass spectrometric analyses of biological macromolecules" Sample in solution N2 gas High voltage applied to metal sheath (~4 kv) Charged droplets MH 2 MH 3 4

Electrospray ization (ESI) nebulizing gas sample solution HV N 2 curtain gas Analyzer Electrospray ization (ESI) Atmospheric pressure Vacuum 1. Solvent evaporation 2. Coulombic repulsion [M nh] n 5 m s Needle 1-5 kv power supply Electrospray ization (ESI) Process (Positive Mode) Taylor cone Site of Spray oxidation current ( i) ESI droplets Solvent and neutralized ions spectrometer Site of reduction Adapted from Kebarle, P and Tang, L, Anal. Chem., 1993, 65(22), 972A MALDI: Matrix Assisted Laser Desorption ization Sample plate h MH Laser /- 20 kv Grid (0 V) 1. Sample is mixed with matrix (X) and dried on plate. 2. Laser flash ionizes matrix molecules. 3. Sample molecules (M) are ionized by proton transfer: XH M MH X. 5

MALDI generation of ions (Matrix-assisted laser desorption ionization) Matrices for MALDI analysis Laser pulse (337 nm) [MH] [M-H] - matrix ions Peptide/protein deposited on crystal surface Sample mixed with a UV-absorbing matrix and is allowed to co-crystallize on the metal target. Peptides/proteins - 3,5-dimethoxy-4-hydroxycinnamic acid (sinapinic acid) - -cyano-4-hydroxycinnamic acid (CHCA) - 2,5-dihydroxybenzoic acid (DHB) - 2-(4-hydroxyphenylazo)-benzoic acid (HABA) Oligonucleotides - 2-aminobenzoic acid - 3-hydroxypicolinic acid (3-HPA) - 2,4,6-trihydroxyacetophenone (THAP) The choice of matrix depends greatly on the solute to be analyzed. Analyzer analyzers separate ions based on their mass-to-charge ratio (m/z) High Vacuum System Data source Analyzer System Time of flight (TOF) Quadrupole Trap Magnetic Sector FT-ICR MS Orbitrap MS Operate under high vacuum (keeps ions from bumping into gas molecules) Actually measure mass-to-charge ratio of ions (m/z) The importance of the mass-to-charge ratio is that according to classical electrodynamics two particles with the same mass-to-charge ratio move in the same path in a vacuum when subjected to the same electric and magnetic fields. F=ma (Newton s second law of motion) F=q(E v B) (Lorentz force Law) (m/q)a = E v B Key specifications are resolution, mass measurement accuracy, and sensitivity. 6

Time-of-flight (Tof) analyzer MALDI Laser; High Energy Monochromatic Light Source Principals of the MALDI-Tof/Tof 4700 - - - time-of-flight flight (Tof) tube - - - detector Accelerating pulse QSTAR TM ESI QQ TOF or MALDI QQ TOF Sample Quadrupole Analyzer Uses a combination of RF and DC voltages to operate as a mass filter. Q0 Q1 Q2 Has four parallel metal rods. Lets one mass pass through at a time. Effective Flight Path = 2.5 m Can scan through all masses or sit at one fixed mass. Mirror (reflector) 7

Quadrupole mass filter / ion guide QTRAP: Linear Trap on a Triple Quadrupole Q0 Q1 Q2 Q3 Exit Octapole linear ion trap funnel and mobility technology 8

http://www.youtube.com/watch?v=o58vtq PLkiI 3D ion trap and 2D ion trap 2D ion trap detection Conversion dynodes High Vacuum System source Analyzer Data System 9

2D ion trap detection Conversion dynodes (electron multipliers) Qtof Penning Trap (ICR cell) http://www.youtube.com/watch?v=bfuzaii-zdk Triple quad http://www.youtube.com/watch?v=-iltw6xqmmw Triple trap (Qtrap) http://www.youtube.com/watch?v=vumcxnlhu4y http://www.youtube.com/watch?v=um_elg02wpy funnel technology http://www.youtube.com/watch?v=iywkxxgu3u8 mobility http://www.youtube.com/watch?v=6ebwdwa2rf0 10

Penning Trap (ICR cell) magnetic field Put the trap in a high magnetic field cyclotron resonance 7 Tesla magnet, or 9.4 T or 12 T or 14.5 T 3D ion trap and 2D ion trap High Vacuum System Data source Analyzer System Microchannel Plate Electron Multiplier analyzer/ion trap AC image 11

2D ion trap detection Conversion dynodes Detecting in the ion trap cyclotron resonance (ICR) 7 Tesla magnet, or 9.4 T or 12 T or 14.5 T Fourier transform- cyclotron resonance FT-ICR MS ThermoFinnigan LTQ-FT m/z = k * B / f Frequencies are converted to masses. 12

LTQ Orbitrap Hybrid Spectrometer Finnigan LTQ Linear Trap API source Linear Trap C-Trap Orbitrap Analyzer k m / z Differential pumping Orbitrap Differential pumping Inventor: Dr. Alexander Makarov, Thermo Electron (Bremen) Data System The mass spectrum shows the results MALDI TOF spectrum of IgG High Vacuum System Data source Analyzer System Relative e Abundance 40000 MH 30000 20000 (M2H) 2 PC 10000 (M3H) 3 0 50000 100000 150000 200000 (m/z) 13

ESI Spectrum of Trypsinogen (MW 23983) M 16 H 1599.8 1499.9 1714.1 1845.9 1411.9 M 15 H M 14 H M13H 1999.6 2181.6 m/z -to-charge ratio How do mass spectrometers get their names? Types of ion sources: Electrospray (ESI) Matrix Assisted Laser Desorption ization (MALDI) Types of mass analyzers: Quadrupole (Quad, Q) Trap Time-of-Flight (TOF) -Either source type can work with either analyzer type: MALDI- TOF, ESI-Quad. -Analyzers can be combined to create hybrid instruments. ESI-QQQ, MALDI QQ TOF, Q Trap Summary: acquiring a mass spectrum Objectives of the Lecture ization Source Form ions (charged molecules) Sorting (filtering) Analyzer Sort s by (m/z) 100 Detection Detect ions 1. Make ions ESI, MALDI 2. Separate/Analyze/Detect ions Tof, ion trap, quadrupole, FT-ICR, Orbitrap Electron multipliers Solid Liquid Vapor 75 50 25 0 1330 1340 1350 Spectrum 3. What is mass resolution and mass accuracy? 14

QuickTime and a decompressor are needed to see this picture. QuickTime and a decompressor are needed to see this picture. 1/27/2014 Slide Acknowledgements Thermo Electron (Fisher) Bruker ABI Sandler Spectrometry Group David Agard group http://www.msg.ucsf.edu/agard/ (Univ. of Calif. San Francisco) Put it in - We need s ( or - ) - In the gas phase Your machine - Tof, Tof / Tof - Quadrupole, trap - FT-ICR, Orbitrap (high resolution) -Hybrids Tell me the RIGHT answer - How right is it? mass resolution and accuracy MS of Proteins and Peptides 1D gel Put it in your machine and tell me the RIGHT answer 1D gel 2D gel 2D gel Protein mixture or Complex mixture Protein mixture or Complex mixture 15

Put it in - We need s ( or - ) - In the gas phase Your machine - Tof, Tof Tof - Quadrupole, trap - FT-ICR, Orbitrap (high resolution) -Hybrids Tell me the RIGHT answer - How right is it? mass resolution and accuracy Source Accelerating pulse Time-of-flight (Tof) analyzer Tof tube (1.0-1.5 m) Effective flight tube (3.0 m) Reflector Resolution 2 x 10 4 No upper limit of mass Scan times ~ 1 sec, good for LC-MSMS s are accelerated so that they have equal kinetic energy. The ions drift down a 1-1.5 meter tube before striking a photomultiplier detector. time of flight (t) depends on the mass of the ion (m), where t = (m/2ev) 1/2 *D V is the applied potential and D is the flight tube distance. For a given instrument, the flight time varies as the square root of the mass of the ion. Traps Expanded view of 3D ion trap The ion trap is an energy well - ions with sufficient energy to enter the trap are retained by an energy barrier on the exit side of the trap. The advantage of the ion trap is that it accumulates selected ions prior to their analysis giving it high initial sensitivity (detection limit of approx. 20 fmol). s are fragmented by collision with helium gas and their daughter ions analyzed within the trap. Selected daughter ions can undergo further fragmentation, thus allowing MS n. The ion trap has a high efficiency of transfer of fragment ions to the next stage of fragmentation (unlike the triple quadrupole instrument). 16