BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Similar documents
Sodium Chloride - Analytical Standard

Sodium Chloride - Analytical Standard

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

DRAFT EAST AFRICAN STANDARD

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

PART II: ANALYSIS OF IRON COORDINATION COMPOUND

Test Method: CPSC-CH-E

Brooklyn College Department of Chemistry

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

DR/4000 PROCEDURE MERCURY. Phase 1: Sample Digestion must be done in a fume hood! Toxic gases may be produced.

SPECIFICATION & TEST PROCEDURE SODIUM SALICYLATE Technical. Molecular weight : Reference : In-house

Exercise 6: Determination of Hardness of Water

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

CHEMISTRY DEPARTMENT

Suggested answers to in-text activities and unit-end exercises. Topic 16 Unit 55

4.4. Revision Checklist: Chemical Changes

Experiment 24. Chemical recycling of poly(ethylene) terephthalate (PET)

Synthesis of Benzoic Acid

Chemical Reactions: The Copper Cycle

Recovery of Copper Renee Y. Becker Manatee Community College

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

Experiment 14 - Qualitative Analysis

Experiment 7A ANALYSIS OF BRASS

Standard Methods for the Examination of Water and Wastewater

CHAPTER 5 REVIEW. C. CO 2 D. Fe 2 O 3. A. Fe B. CO

JUNIOR COLLEGE CHEMISTRY DEPARTMENT EXPERIMENT 22 SECOND YEAR PRACTICAL. Name: Group: Date: Cr 3+ (aq)+ 3 OH (aq) Cr(OH) 3(s)

QUALITATIVE ANALYSIS OF METAL CATIONS

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

EXPERIMENT: LIMITING REAGENT. NOTE: Students should have moles of reactants in DATASHEET converted into masses in grams prior to the lab period.

An equation for the decomposition of hydrogen peroxide is shown below.

INORGANIC CHEMISTRY (LAB MANUAL)

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Set 4 Marking Scheme: Acid Bases & Salts 2010

To precipitate nickel (II) sulfide, the sulfide ion concentration must be a lot larger:

Qualitative Analysis I - Cations

ICP-OES Application Note Number 35

UNIT 6 REDOX REACTIONS Answers

WHAT IS A BATTERY? way to store energy is through chemical bonds in substances, which is the basic

National standard of People s Republic of China

CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Synthesis and Analysis of a Coordination Compound

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Aspirin Synthesis H 3 PO 4

Oxidation-Reduction (Redox)

4.4. Revision Checklist: Chemical Changes

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

DETERMINATION OF CHEMICAL OXYGEN DEMAND COD

BUREAU OF INDIAN STANDARDS. Draft Indian Standard. SPECIFICATION FOR BASIC CHROMIUM SULPHATE (FOR TANNING) (First revision of IS 6301) ICS:

Advanced Unit 7: Chemistry Practical Examination (SET A) Candidates must have: Scientific calculator Ruler

Method for estimation of iodine in urine

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education CHEMISTRY

THE CATHOLIC UNIVERSITY OF EASTERN AFRICA A. M. E. C. E. A

ANALYSIS OF ZINC IN HAIR USING FLAME ATOMIC ABSORPTION SPECTROSCOPY

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

MBOONI WEST SUB - COUNTY JOINT EVALUATION TEST

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

Unit 3 Chemistry - Volumetric Analysis

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

DR/4000 PROCEDURE LEAD. 2. The display will show: 3. Fill a 250-mL graduated cylinder to the 250-mL mark with sample.

Standardization of Hydrochloric Acid by Anhydrous Sodium Carbonate

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

THE UNITED REPUBLIC OF TANZANIA NATIONAL EXAMINATIONS COUNCIL CERTIFICATE OF SECONDARY EDUCATION EXAMINATION

UNITED NATIONS. ENVIRONMENT PROGRAMME MEDITERRANEAN ACTION PLAN 25 May 2015 Original: English. UNEP(DEPI)/ MED WG.417/Inf.14

(a) (i) Explain what is meant by the terms transition element, complex ion and ligand,

1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter.

EXPERIMENT #9 PRELAB EXERCISES. Redox Titration (Molarity Version) Name Section. 1. Balance the following redox reaction under acidic conditions.

PHYSICAL SCIENCE 0652/5

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

Per Examiner s use only

EXPERIMENTS. Testing products of combustion: Reducing Copper(III) Oxide to Copper. Page 4

Preparation of a Coordination Compound. Step 1 Copy the balanced equation for the preparation of FeC 2 O 4.. 3H2 O from FeC 2 O 4. Mass of watch glass

EXPERIMENT THREE THE CANNIZARO REACTION: THE DISPROPORTIONATION OF BENZALDEHYDE

for free revision past papers visit:

Practical Examination 2 (Part B Practical Test)

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

ICSE Board Class X Chemistry Board Paper Time: 1½ hrs Total Marks: 80


Write an overall equation for the first stage in the rusting of iron.

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level CHEMISTRY 9701/03

C q T q C T. Heat is absorbed by the system H > 0 endothermic Heat is released by the system H < 0 exothermic


Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

ASPARTAME. Not less than 98% and not more than 102% on the dried basis. White, odourless, crystalline powder, having a strong sweet taste

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

9.1 Qualitative Analysis

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Experiment 8 Introduction to Volumetric Techniques I. Objectives

Spectrophotometric Determination of an Equilibrium Constant

NAME INDEX NUMBER CANDIDATE SIGNATURE DATE.. 233/2/ CHEMISTRY PAPER 3 (PRACTICALS) JULY/AUGUST ¼ HOURS

CALCIUM (EGTA-Titrimetric)

ICSE Chemistry Model Paper-9

Transcription:

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD For the Determination of Mercury, Cadmium and Lead in Alkaline Manganese Cells Using AAS, ICP-AES and "Cold Vapour" European Portable Battery Association (EPBA) Battery Association of Japan (BAJ) National Electrical Manufacturers Association (NEMA, USA) April 1998

CONTENTS 1. Construction of an Alkaline Manganese Cell 2. Determination 3. Material 4. Principle 5. Apparatus 6. Reagents 7. Standards Preparation 7.1 Matrix Preparation for Cadmium, Lead and Mercury for Analysis by AA and Cold Vapour 7.2 Lead and Cadmium for Analysis by AA 7.3 Lead and Cadmium for Analysis by ICP-AES 7.4 Mercury for Analysis by Cold Vapour 8. Sample Preparation 9. Mercury Analysis by Cold Vapour 10. Lead Analysis by AA 11. Cadmium Analysis by AA 12. Lead and Cadmium Analysis by ICP-AES 13. Calculations 2 of 9

1. CONSTRUCTION OF AN ALKALINE MANGANESE CELL 3 of 9

2. DETERMINATION Total mercury (Hg), cadmium (Cd) and lead (Pb). 3. MATERIAL Undischarged alkaline manganese cells. 4. PRINCIPLE The cell is opened with cutting pliers. The opened cell, except label, is dissolved in nitric acid with dropwise addition of hydrogen peroxide. The sample is diluted to specific volume, mixed thoroughly and then filtered. An aliquot of the filtrate is taken for the determination of cadmium and lead by Atomic Absorption (AA) Spectrophotometry using air-acetylene flame or Inductive Coupled Plasma Spectrometer (ICP-AES). Another aliquot of solution is taken for determination of mercury using Cold Vapour Mercury Analyser. Recommended wavelengths are: Instrument Element Wavelength nm AA Pb 217 AA Cd 228.8 ICP Pb 220.35 ICP Cd 228.8 Cold Vapour Hg 253.7 Note: Wavelength selected for Pb and Cd should not interfere with elements such as Mn, Zn, Ni, Fe, Cu, Sn, Bi, In, and Ti present in the matrix. 5. APPARATUS i. Atomic Absorption Spectrophotometer Inductive Coupled Plasma Spectrometer i Cold Vapour Mercury Analyser Volumetric flasks, 2 l, 1 l, 500 ml, 250 ml, 100 ml and 5 ml v. vi. Erlenmeyer flasks, 3 l, 2 l, 1 l, 500 ml and 100 ml Buchner vacuum filter or equivalent v Filter paper, Watman No. 50 or equivalent vi Volumetric pipettes, 10 ml, 20 ml, 25 ml and 50 ml ix. Micropipettes, 10 µl, 50 µl, 250 µl, 500 µl and 1000 µl x. 300 ml BOD bottles xi. Closed vessel microwave x Microwave digestion vessels xi Beakers, 2 l, 1 l and 500 ml 4 of 9

6. REAGENTS i. Concentrated nitric acid (HNO 3 ) 20% nitric acid i 30% hydrogen peroxide (H2 ) 1000 ppm cadmium standard solution v. 1000 ppm lead standard solution vi. 1000 ppm mercury standard solution v 50% sulphuric acid (H 2 SO 4 ) vi 35% nitric acid (HNO 3) ix. 10% tin chloride (SnCl 2) solution x. 12% hydroxylamine sulphate (2NH2OH.H2SO 4) solution xi. 5% potassium permanganate (KMnO 4) solution x 1 ppm mercury working standard solution made from standard solution xi High purity zinc powder x xv. High purity manganese dioxide (Mn ) powder Potassium hydroxide (KOH) pellets 7. STANDARDS PREPARATION 7.1 Matrix Preparation for Cadmium, Lead and Mercury Analysis by AA and Cold Vapour i. Weigh 20g of zinc powder, 40g of MnO and 6g of KOH into 2 l beaker. 2 Note: The matrix materials should be free of Hg, Cd and Pb or with known concentration of Hg, Cd and Pb to correct for the standard concentration. Add 500 ml of DI water and 400 ml of HNO 3. i Add dropwise H 2 to solution until reaction has been completed. (No bubbling upon addition of H 2.) Heat matrix solution on hot plate to aid dissolution. Allow sufficient time for reaction/dissolution. Transfer the cooled matrix solution to a 2 l volumetric flask and dilute to volume. Mix thoroughly. 7.2 Lead and Cadmium Standard Solutions for Analysis by Atomic Absorption Into five (5) separate 100 ml volumetric flasks, add about 25 ml matrix solution. To make 0, 2.5, 5, 10 and 15 ppm Pb and 0, 0.1, 0.25, 0.5 and 1 ppm Cd standard solutions, add the following aliquots of 1000 ppm Pb and 1000 ppm Cd into each of the volumetric flasks and dilute to volume with matrix solution. AA Standard Solution Conc. Pb ppm µl 1000 ppm Pb Added in 100 ml µl 1000 ppm Cd Added in 100 ml Cd ppm 0 0 0 0 2.5 0.1 250 10 5 0.25 500 25 10 0.5 1000 50 15 1 1500 100 5 of 9

7.3 Lead and Cadmium Standard Solutions for Analysis by Inductive Coupled Plasma Spectrometer (ICP-AES) i. Matrix Preparation: a. Weigh 2.3 g of zinc powder, 5.7 g of Mn, 0.88 g of KOH, 2.6 g of can material and 0.2 g of conductor material into a 500 ml beaker. Note: The matrix materials should be free of Cd and Pb or with known concentration of Cd and Pb to correct for the standard concentration. b. Add 50 ml of DI water and 100 ml of HNO 3. c. Add dropwise H 2 to solution until reaction has been completed. (No bubbling upon addition of H 2.) Heat matrix solution on hot plate to aid dissolution. Allow sufficient time for reaction/dissolution. d. Transfer the cooled matrix solution to a 500 ml volumetric flask and dilute to volume. Mix thoroughly. e. Filter the thoroughly mixed matrix solution through the vacuum funnel if insolubles are present. Discard the first 25 ml of the filtrate. Filter the remaining solution into a 500 ml container for standard preparation below. Standard Preparation: a. Into four (4) separate 100 ml volumetric flasks, add about 25 ml of matrix solution from above. To make 0.1, 0.5, 2.5 and 5 ppm Pb and 0.1, 0.25 and 0.5, 1 ppm Cd standard solutions, add the following aliquots of 1000 ppm Pb and 1000 ppm Cd into each of the volumetric flasks and dilute to volume with the matrix solution. b. Use the remaining matrix solution as a blank. The blank has 0 ppm of Pb and 0 ppm of Cd. ICP Standard Solution Conc. Pb ppm µl 1000 ppm Pb Added in 100 ml µl 1000 ppm Cd Added in 100 ml Cd ppm 0 0 0 0 0.1 0.1 10 10 0.5 0.25 50 25 2.5 0.5 250 50 5 1 500 100 7.4 Mercury Standard Solution for Analysis by Cold Vapour Analyser i. Prepare six standard solutions containing 0 to 0.7 µg mercury by placing 0, 50, 100, 250, 500 and 700 µl aliquots of the 1 ppm Hg working standard into six 300 ml BOD bottles. Add 100 ml matrix solution from step 7.1 to each. 6 of 9

8. SAMPLE PREPARATION Analyse cells in duplicate. i. Weigh the cell and record total cell weight. Open cell with cutting pliers inside a plastic bag in case of electrolyte leakage. Remove the negative terminal with the conductor. With the help of tweezers, remove the separator paper containing the anode from the cell. Carefully and thoroughly scrape off all the anode slurry material from the separator into a centrifuge tube. Centrifuge the anode slurry to separate the gellant from the zinc. Transfer the gellant portion into microwave vessel(s)*. Transfer the remaining components of the cell (can, cathode, electrolyte, separator, conductor including plastic grommet, etc.) and the zinc portion into a Erlenmeyer flask. (Use 3 l flask for D size cells, 2 l for C size cells, 1 l for AA cells and 500 ml for AAA and 9V cells.) Digest the gellant following step (vi). Digest the remaining cell components following steps (iii) and (v) or steps (iv) and (v). * Number of microwave vessels depends on cell sizes and microwave capacity. i For analysis by AA add nitric acid and water according to Table 1 below: Table 1 Cell Size H 2 O (ml) HNO 3 (ml) Final Volume (V) (ml) D 400 400 2000 C 400 200 1000 AA 200 100 500 AAA 100 50 250 9V 200 100 500 For analysis by ICP-AES add nitric acid and water according to Table 2 below: Table 2 Cell Size H 2 O (ml) HNO 3 (ml) Final Volume (V) (ml) D 200 200 1000 C 100 100 500 AA 40 40 200 AAA 20 20 100 9V 100 100 500 v. Add dropwise H 2 to sample solutions until reaction has been completed. (No bubbling upon addition of H 2 ) Heat sample on hot plate to aid sample dissolution. Allow sufficient time for reaction/dissolution. vi. v vi Decompose the gellant obtained from step (ii) by closed vessel microwave technique using HNO 3 and H 2. (5 ml of HNO 3 and 2 ml H 2 for 0.5 g gellant, best consult microwave manufacturer) Transfer the decomposed gellant solution into the same Erlenmeyer flask as in step (v) above. Mix the solution thoroughly and allow to cool. Filter the thoroughly mixed solution and dilute to final volume according to Table 1 or Table 2. 7 of 9

9. MERCURY ANALYSIS BY COLD VAPOUR ANALYSER i. Set up the AAS "Cold Vapour" apparatus in accordance with manufacturer's manual. i Analyse the six standards from step 7.4 following steps iii - v Add 5 ml 50% sulphuric acid. Mix. Add 5 ml 35% nitric acid. Mix. v. Add 1 ml 5% potassium permanganate solution and if necessary additional portions in 1 ml increments until the purple colour persists for at least 15 minutes. vi. v vi ix. Add 2 ml of hydroxylamine sulphate to reduce excess potassium permanganate. Mix until clear. Add 5 ml tin chloride solution and immediately attach the aeration apparatus to the BOD bottle. Allow to stand. When recorder pen has levelled off remove aeration apparatus. Transfer a 100 ml aliquot of each sample to a 300 ml BOD bottle. Analyse the sample in the same manner. Note: Alternate automated continuous flow apparatus may also be used. 10. LEAD ANALYSIS BY AA i. Set-up AA with air-acetylene flame. i Set-up calibration curves by analysing 0, 2.5, 5, 10 and 15 ppm lead standard solutions. Analyse the filtered sample solutions for lead against the calibration curve. 11. CADMIUM ANALYSIS BY AA i. Set-up AA with air-acetylene flame. i Set-up a calibration curve by analysing 0, 0.1, 0.25, 0.5 and 1 ppm cadmium standard solutions. Analyse the filtered sample solution for cadmium against the calibration curve. NOTE: A If Pb or Cd in the sample solutions is lower than the lowest standard, pipette a 50 ml aliquot of sample solution and concentrate to 2-3 ml on the hot plate, volumize with 20% HNO 3 to 5 ml in a volumetric flask and then analyse on AA. B. If Pb or Cd in the sample solution is higher than the highest standard, take an aliquot and dilute with 20% HNO 3 to proper concentration range. Analyse on AA. 8 of 9

12. LEAD AND CADMIUM ANALYSIS BY ICP-AES i. For cell size D samples, pipette 20 ml of the filtered sample solution into a 100 ml volumetric flask. Dilute to volume with a 20% HNO 3 solution. For cell size C, AA and AAA, pipette 25 ml of the filtered sample solution into a 100 ml volumetric flask. Dilute to volume with a 20% HNO 3 solution. For 9V battery, pipette 50 ml of the filtered sample solution into a 100 ml volumetric flask. Dilute to volume with a 20% HNO 3 solution. i Set-up ICP according to manufacturer s instructions. Calibrate the ICP for lead and cadmium with the ICP matrix matched standard solution. Analyse the diluted sample from step (i) above for lead and cadmium against the standard curve without changing any parameter. 13. CALCULATIONS ppm Hg of Total Cell Weight (TCW) = (a - b) x V v x TCW (g) ppm Pb or Cd of TCW = ppm (Reading) x V x DF TCW (g) Where: a = µg Hg in sample aliquot b = µg Hg in blank aliquot v = aliquot (in ml) taken for Hg analysis V = Total sample volume in ml (see Table 1 or 2) DF = Dilution factor (For ICP: D size - DF= 5; C, AA & AAA size - DF = 4 9V - DF = 2) Mercury, cadmium and lead should be reported to 0.1 ppm. 9 of 9