Deliverable WP2 / D2.11 (M42) WP2- NA2: Remote sensing of vertical aerosol distribution Deliverable D2.11: Report on 2nd IC campaign

Similar documents
Misure LIDAR di aerosol e trasporto da sorgenti remote. Gelsomina Pappalardo CNR-IMAA

EARLINET, the ACTRIS aerosol vertical profiling component

Raman and elastic lidar techniques for aerosol observation at CIAO

Lidar and radiosonde measurement campaign for the validation of ENVISAT atmospheric products

Long-term aerosol and cloud database from correlative CALIPSO and EARLINET observations

2.5 COMPARING WATER VAPOR VERTICAL PROFILES USING CNR-IMAA RAMAN LIDAR AND CLOUDNET DATA

FIRST SYSTEMATIC OBSERVATIONS OF SAHARAN DUST OVER EUROPE DURING EARLINET ( ): STATISTICAL ANALYSIS AND RESULTS

Aerosol lidar intercomparison in the framework of the EARLINET project. 1. Instruments

ACTRIS aerosol vertical profiles: advanced data and their potential use in a aerosol observations/models combined approach

Three years of systematic lidar observations of Saharan dust outbreaks at Naples EARLINET station

EARLINET lidar quality assurance tools

25 TH INTERNATIONAL LASER RADAR CONFERENCE

Ground-based Validation of spaceborne lidar measurements

Aerosols and Clouds: Long-term Database from Spaceborne Lidar Measurements

Validation of ADM-Aeolus L2 aerosol and cloud product employing advanced ground-based lidar measurements (VADAM)

MIPAS WATER VAPOUR MIXING RATIO AND TEMPERATURE VALIDATION BY RAMAN-MIE-RAYLEIGH LIDAR

Atmospheric aerosol characterization in the urban area of Napoli

Aerosol-type-dependent lidar ratios observed with Raman lidar

microwave profiler: comparisons and synergies

European ceilometer and lidar networks for aerosol profiling and aviation safety the German contribution

Lidar intercomparisons on algorithm and system level in the frame of EARLINET

Integrazione di tecniche di osservazione per la caratterizzazione di aerosol di origine vulcanica

1 Fundamentals of Lidar

LAUNCH Concept. Lindenberg Observatory

Satellite techniques for timely detection and near real-time monitoring of volcanic ash clouds for aviation safety

VALIDATION OF GOMOS HIGH RESOLUTION TEMPERATURE DATA WITH THE U. BONN LIDAR AT THE ESRANGE DURING JANUARY AND FEBRUARY 2003

D. Cimini*, V. Cuomo*, S. Laviola*, T. Maestri, P. Mazzetti*, S. Nativi*, J. M. Palmer*, R. Rizzi and F. Romano*

WLS70: A NEW COMPACT DOPPLER WIND LIDAR FOR BOUNDARY LAYER DYNAMIC STUDIES.

25 TH INTERNATIONAL LASER RADAR CONFERENCE

VALIDATION OF MIPAS WATER VAPOR PRODUCTS BY GROUND BASED MEASUREMENTS

Remote sensing of meteorological conditions at airports for air quality issues

Estimating extinction coefficient and aerosol concentration profiles in the atmospheric surface boundary layer with commercial lidar ceilometers

Advanced characterization of aerosol properties through the combination of active/ passive ground-based remote sensing (and in situ measurements)

STATISTICS OF OPTICAL AND GEOMETRICAL PROPERTIES OF CIRRUS CLOUD OVER TIBETAN PLATEAU MEASURED BY LIDAR AND RADIOSONDE

Lecture 11: Doppler wind lidar

EARLINET observations of the May long-range dust transport event during SAMUM 2006: validation of results from dust transport modelling

LAUNCH Concept. Lindenberg Observatory

Gwangju Institute of Science and Technology (GIST), Gwangju, Republic of Korea

l-- 0 Daytime Raman Lidar Measurements of Water Vapor During the ARM 1997 Water Vapor Intensive Observation Period D.D. Turner' and J.E.M.

First water vapor measurements over Athens, Greece, obtained by a combined Raman-elastic backscatter lidar system

What are Aerosols? Suspension of very small solid particles or liquid droplets Radii typically in the range of 10nm to

NASA/GSFC Raman Lidar Instrumentation Available for COPS

VALIDATION OF MIPAS TEMPERATURE DATA WITH THE U. BONN LIDAR AT THE ESRANGE DURING JULY AND AUGUST 2002

Intercomparison of Mobility Particle Size Spectrometers

ACTRIS TNA Activity Report

Optic Detectors Calibration for Measuring Ultra-High Energy Extensive Air Showers Cherenkov Radiation by 532 nm Laser

Systematic coordinated Saharan dust profiling over Europe in the frame of the EARLINET project ( )

A new lidar for water vapor and temperature measurements in the Atmospheric Boundary Layer

First water vapor measurements over Athens, Greece, obtained by a combined Raman-elastic backscatter lidar system.

Scanning Raman Lidar Measurements During IHOP

MODEL LIDAR COMPARISON OF DUST VERTICAL DISTRIBUTIONS OVER ROME (ITALY) DURING

Study on the rainfall dependence structure using radar and rain gauge data

SPECIAL PROJECT FINAL REPORT

PoS(ICRC2015)568. An Estimate of the Live Time of Optical Measurements of Air Showers at the South Pole

EARLINET Observations of Saharan Dust Outbreaks over Europe

EARLINET: A European Aerosol Research Lidar Network to Establish an Aerosol Climatology

ACTRIS TNA Activity Report

ABB Remote Sensing Atmospheric Emitted Radiance Interferometer AERI system overview. Applications

Detailed studies of atmospheric calibration in Imaging Cherenkov astronomy. Sam Nolan, Cameron Rulten

Interactive comment on A new method for nocturnal aerosol measurements with a lunar photometer prototype by A. Barreto et al.

E-PROFILE: Glossary of lidar and ceilometer variables. compiled by: I. Mattis and F. Wagner

Lecture 32. Lidar Error and Sensitivity Analysis

Intercomparison of Mobility Particle Size Spectrometers

LIDAR AND ROBOTIZED TOTAL STATIONS DATA INTEGRATED FOR A 3-D 3 REPRESENTATION: THE MONTAGUTO EARTHFLOW STUDY

Dense water plumes SW off Spitsbergen Archipelago (Arctic) in

Optical properties of single-layer, double-layer, and bulk MoS2

RESULTS OF MID-LATITUDE MIPAS VALIDATION MEASUREMENTS OBTAINED BY THE SAFIRE-A AIRBORNE SPECTROMETER

5.3 INVESTIGATION OF BOUNDARY LAYER STRUCTURES WITH CEILOMETER USING A NOVEL ROBUST ALGORITHM. Christoph Münkel * Vaisala GmbH, Hamburg, Germany

ENVISAT VALIDATION CAMPAIGN AT IMAA CNR

Name of research institute or organization: École Polytechnique Fédérale de Lausanne (EPFL)

AUTOMATIC MONITORING OF BOUNDARY LAYER STRUCTURES WITH CEILOMETER ABSTRACT

Name of research institute or organization: École Polytechnique Fédérale de Lausanne (EPFL)

LIDAR Developments at Clermont-Ferrand France for Atmospheric Observation

ADM-Aeolus Progressing Towards Mission Exploitation

ENVISAT Data Validation with Ground-based Differential Absorption Raman Lidar (DIAL) at Toronto (73.8N, 79.5W) under A.O. ID 153

Final report on the operation of a Campbell Scientific CS135 ceilometer at Chilbolton Observatory

On the statistical significance of climatic trends estimated from GRUAN tropospheric time series

Characterization of free-tropospheric aerosol layers from different source regions

Choosing the proper technique for measuring the particle light absorption

Height correction of atmospheric motion vectors (AMVs) using lidar observations

A NOVEL RADIOSONDE PAYLOAD TO STUDY UPPER TROPOSPHERIC / LOWER STRATOSPHERIC AEROSOL AND CLOUDS

GLAS Atmospheric Products User Guide November, 2008

Supporting information. Tin dioxide electrolyte-gated transistors working in depletion and enhancement

Analysis of PAH Mass Spectra Periodicity by Fast Fourier Transform

Results from the ARM Mobile Facility

Intercomparison of Mobility Particle Size Spectrometers

Profiling of Saharan dust and biomass-burning smoke with multiwavelength polarization Raman lidar at Cape Verde

HIGH RESOLUTION SOIL MOISTURE CONTENT FROM SENTINEL-1 DATA

Spectral surface albedo derived from GOME-2/Metop measurements

Luca Fiorani, Bertrand Calpini, Laurent Jaquet, Hubert Van den Bergh, and Eric Durieux

Preliminary testing of new approaches to retrieve aerosol properties from joint photometer-lidar inversion

Lecture 08. Solutions of Lidar Equations

Lecture 14. Principles of active remote sensing: Lidars. Lidar sensing of gases, aerosols, and clouds.

Lecture 28. Aerosol Lidar (4) HSRL for Aerosol Measurements

Supplement of Studying the vertical aerosol extinction coefficient by comparing in situ airborne data and elastic backscatter lidar

ADM-Aeolus ESA s Wind Lidar Mission and its spin-off aerosol profile products

Easy, Accurate Aerosol Profiling Weather forecasting Atmospheric observation Aviation safety MICRO PULSE LIDAR. Commercial.

COMPACT MICRO-PULSE BACKSCATTER LIDAR AND EXAMPLES OF MEASUREMENTS IN THE PLANETARY BOUNDARY LAYER *

Deriving aerosol scattering ratio using range-resolved lidar ratio

PARAFOG: a new decision support system for the airports to monitor and to predict radiation fog based on automatic LIDARceilometer

Transcription:

WP2- NA2: Remote sensing of vertical aerosol distribution Deliverable D2.11: Report on 2nd IC campaign

Table of Contents 1 Introduction... 2 2 MUSA (reference lidar system)... 4 3 Inter-comparison MALIA - MUSA 14-18 October 2013... 6 3.1 MALIA... 6 3.2 Day time intercomparison 17. October 2013... 9 3.3 Night time intercomparison 17. October 2013... 11 4 Inter-comparison Lecce lidar - MUSA 21-25 October 2013... 14 4.1 Lecce lidar system... 14 4.2 Intercomparison 23. October 2013... 17 5 Inter-comparison Minsk MSTL-2 with LMR 30. 09. 2013... 20 1 Introduction Figure 1.1 EARLINET lidar stations (2014) The many lidar systems within EARLINET are all home- or custom-made, and hence very different. From small, portable, single wavelength lidar systems to huge, stationary, multi-channel lidar systems with several telescopes to better cover the far and near ranges. Furthermore, as most lidar systems are research instruments, they are continuously developing and changing. A common quality assurance strategy can not cover all the details of all systems, but must focus on some main paramet ers. One can evaluate the quality of a measurement instrument by either comparing a measured quantity

with a known quantity like a standard target, or one compares with the outcome of a standard meas urement instrument of the same target. For lidar systems both standards do not exist neither a standard target, nor a standard instrument. In the frame of EARLINET-ASOS the activity NA2.2 (Quality Assurance) had been established to de velop tools for testing the accuracy and the temporal stability of the quality of the lidar systems. The developed internal check-up tools can be applied to all lidar systems. The near range limit (overlap function) is checked with the telecover test, and the far range capability and accuracy with the Rayleigh fit test. The trigger-delay (zero-bin) test verifies the correct range correction, which is very important in the near range below about 1 km range, and the dark measurement and pulse gener ator measurements deal with signal distortions. These tests are performed yearly with every lidar system and with every signal channel, and the results are documented in yearly ACTRIS "reports on internal hardware quality checks". Regarding the overall quality check, direct lidar inter-comparisons are scheduled during ACTRIS for all lidar systems not checked in this way within the last five years. For direct lidar inter-comparisons two or more lidar systems are located close to each other to measure the same atmosphere during the same time periods. Although the lidars are located close to each other, the measured atmospheric volume is never exactly the same, and the intercomparison between systems is often complicated by the intrinsic differences of the systems (at least one must be moveable), which are e.g. different measurement ranges, different sampling rates, and different analysis software packages. Sometimes the weather conditions during the limited intercomparison campaigns can be unfortunate, so that the inter-compared signals cannot reveal the desired details. Furthermore, such direct lidar intercomparisons are costly regarding man power and money, and cannot be repeated regularly. Three transportable EARLINET lidar systems are currently available as reference lidar systems, which have shown their outstanding quality and temporal stability in several inter-comparisons. These are the MULIS and POLIS lidar systems of the Ludwig-Maximilians-University of Munich, Germany, and the MUSA lidar system of the Consiglio Nazionale delle Ricerche - Istituto di Metodologie per l'analisi Ambientale, Potenza, Italy.

2 MUSA (reference lidar system) The MUSA lidar system of the Consiglio Nazionale delle Ricerche, Istituto di Metodologie per l'analisi Ambientale (CNR-IMAA) in Potenza / Italia was selected as an EARLINET reference lidar system during the direct intercomparison of twelve EARLINET lidar systems during EARLI09 [Wandiger et al., EARLINET instrument intercomparison campaigns: overview on strategy and results, Atmos. Meas.Tech. Discuss., in preparation, 2014]. MUSA signals at all wavelengths showed deviations <5% from the wheigthed mean of all the lidar sytems. Figure 2.1 The MUSA lidar in the mobile container. Figure 2.2 Optical setup of the MUSA lidar.

Table 2.1 Specifications of the MUSA reference lidar from the EARLINET handbook of instruments.

3 Inter-comparison MALIA - MUSA 14-18 October 2013 The MALIA lidar system of the Consorzio Nazionale Interuniversitario per la Scienze Fisiche della Materia (CNISM) in Napoli/Italia was inter-compared with the MUSA referece lidar of the Consiglio Nazionale delle Ricerche, Istituto di Metodologie per l'analisi Ambientale (CNR-IMAA) during the measurement campaign in Napoli CNISM NALI13 (Napoli Lidar Intercomparison 2013) between 1418 October 2013. MALIA MUSA Figure 3.1 The MALIA and MUSA lidar systems in their containers. 3.1 MALIA Table 3.1 Main specifications of the MALIA lidar.

Figure 3.2 Optical setup of the MALIA lidar.

Table 3.2 Full specifications of the MALIA lidar from the EARLINET handbook of instruments.

3.2 Day time intercomparison 17. October 2013 Figure 3.3 Quicklook of the atmospheric situation during the daytime intercomparison period (red rectangle) on 17.10.2013. Figure 3.4 Attenuated backscatter signals and relative deviation of the MALIA from the MUSA signal at 355 nm on 17.10.2013 between 11:45 and 12:04 UT.

Figure 3.5 Attenuated backscatter signals and relative deviation of the MALIA from the MUSA signal at 532 nm (parallel polarization) on 17.10.2013 between 11:45 and 12:04 UT. Figure 3.6 Attenuated backscatter signals and relative deviation of the MALIA from the MUSA signal at 532 nm (perpendicular polarization) on 17.10.2013 between 11:45 and 12:04 UT.

3.3 Night time intercomparison 17. October 2013 Figure 3.7 Quicklook of the atmospheric situation during the nighttime intercomparison period (red rectangle) on 17.10.2013. Figure 3.8 Attenuated backscatter signals and relative deviation of the MALIA from the MUSA signal at 355 nm on 17.10.2013 between 23:03 and 00:06 UT.

Figure 3.9 Attenuated backscatter signals and relative deviation of the MALIA from the MUSA signal at 532 nm (parallel polarization) on 17.10.2013 between 23:03 and 00:06 UT. Figure 3.10 Attenuated backscatter signals and relative deviation of the MALIA from the MUSA signal at 532 nm (perpendicular polarization) on 17.10.2013 between 23:03 and 00:06 UT.

Figure 3.11 Attenuated backscatter signals and relative deviation of the MALIA from the MUSA signal at 387 nm on 17.10.2013 between 23:03 and 00:06 UT Figure 3.12 Attenuated backscatter signals and relative deviation of the MALIA from the MUSA signal at 607 nm on 17.10.2013 between 23:03 and 00:06 UT

4 Inter-comparison Lecce lidar - MUSA 21-25 October 2013 The Lecce lidar system of the University of Salento, Lecce, Italia, was inter-compared with the MUSA referece lidar of the Consiglio Nazionale delle Ricerche, Istituto di Metodologie per l'analisi Ambien tale (CNR-IMAA) during the measurement campaign in Lecce (Lecce Lidar Intercomparison 2013) between 21-25 October 2013. MUSA LECCE system Figure 4.1 The Lecce lidar in the University building with roof window and the MUSA lidar systems in the container. 4.1 Lecce lidar system Table 4.1 Main specifications of Lecce lidar system.

Figure 4.2Optical setup of the Lecce lidar system.

Table 4.2 Full specifications of the Lecce lidar from the EARLINET handbook of instruments.

4.2 Intercomparison 23. October 2013 Figure 4.3 Quicklook of the atmospheric situation during the intercomparison period (red rectangle) on 23.10.2013. Figure 4.4 Attenuated backscatter signals and relative deviation of the Lecce lidar from the MUSA signal at 355 nm on 23.10.2013 between 20:39 and 21:06 UT. Calculated molecular backscatter signal from radiosonde data Brindisi airport 00 UT for comparison.

Figure 4.5 Attenuated backscatter signals and relative deviation of the Lecce lidar from the MUSA signal at 387 nm on 23.10.2013 between 20:39 and 21:06 UT. Calculated molecular backscatter signal from radiosonde data Brindisi airport 00 UT for comparison. Figure 4.6 Attenuated backscatter signals and relative deviation of the Lecce lidar from the MUSA signal at 532 nm on 23.10.2013 between 20:39 and 21:06 UT. Calculated molecular backscatter signal from radiosonde data Brindisi airport 00 UT for comparison.

Figure 4.7 Attenuated backscatter signals and relative deviation of the Lecce lidar from the MUSA signal at 607 nm on 23.10.2013 between 20:39 and 21:06 UT. Calculated molecular backscatter signal from radiosonde data Brindisi airport 00 UT for comparison. Figure 4.8 Attenuated backscatter signals and relative deviation of the Lecce lidar from the MUSA signal at 1064 nm on 23.10.2013 between 20:39 and 21:06 UT. Calculated molecular backscatter signal from radiosonde data Brindisi airport 00 UT for comparison.

5 Inter-comparison Minsk MSTL-2 with LMR 30. 09. 2014 The Stepanov Institute of Physics (IPNASB) in Minsk, Belarus, operates two lidar systems: the mobile LMR, and the stationary MSTL-2. The LMR-mobile lidar participated in the EARLI09 intercomparison of twelve lidar systems in Leipzig, Germany, in 2009. The both lidars were intercompared in Minsk on 30.09.2014 16:00 16:07. Table 5.1 Full specifications of the MSTL-2-lidar from the EARLINET handbook of instruments.

Table 5.2 Full specifications of the LMR-mobile lidar from the EARLINET handbook of instruments.

Figure 5.1 Attenuated backscatter signals (left) and relative deviation (right) between the LMR and MSTL-2 lidar systems at 355 nm on 30.09.2014 between 16:00 and 16:07. Figure 5.2 Attenuated backscatter signals (left) and relative deviation (right) between the LMR and MSTL-2 lidar systems at 532 nm on 30.09.2014 between 16:00 and 16:07. Figure 5.3 Attenuated backscatter signals (left) and relative deviation (right) between the LMR and MSTL-2 lidar systems at 1064 nm on 30.09.2014 between 16:00 and 16:07.