DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Similar documents
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

ED 701 General Industry Pressure Transmitter

Heat stress index. Dewpoint. pressure. altitude

Automatic titrators, TitroMatic

Data Sheet / Instructions. Dewpoint MeterO

Kestrel 4500 Pocket Weather Tracker

Edgetech Instruments Inc.

Dewpoint Meter Data Sheet / Instructions

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

473-SHX Dew Point Mirror

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Chilled Mirror Hygrometry

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

473 Dew Point Hygrometer

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

Relative pressure transmitter type 520

473 Dew Point Hygrometer

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

all stainless steel transducer multimedia compatibility

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

ISEmax CAM40/CAS40. Technical Information

Humidity Calibration Solutions

Pressure Transmitter ED 701

Operating Instructions for Digital Manometer. Model: MAN-SD

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Humidity Calibration Solutions

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

Direct-operated 2/2-way compact solenoid valves Type EV210A

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Fundamentals of Moisture Measurement in Industrial Applications

Solenoid valves 2/2-way direct-operated type EV210A

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

Metso Concentration Measurement 3300

Air velocity & IAQ measuring instruments

Acceleration/Velocity/Displacement VIBRATION METER

Microscopy Cryostat System

Application Your benefits

SPECIFICATION SHEET Model 2A

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Air velocity & IAQ measuring instruments

Pressure Measurement Single-range transmitters for general applications

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

SPECIFICATIONS PARTICLE SENSOR KS-28B Higashimotomachi, Kokubunji, Tokyo , Japan

Model DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint

Reflex-Radar BM 100 A

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Solenoid valves Type EVUL

SERIES 4000 PRECISION DEWPOINT HYGROMETER Integrale INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

LANCOM200 PORTABLE ACID DEWPOINT TEMPERATURE MONITORING. Acid Dewpoint SO3 H2 SO4 QUALITY CUSTOMER SOLUTIONS

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Introduction to Blackbody Sources

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

HANDHELD GAS ANALYZER DELTA 65

Ion-Chamber Survey Meter OD-02

Direct-operated 2/2-way solenoid valves Type EV210B

792A AC/DC Transfer Standard

SmartLine Radar Level Meter RM70

Electromagnetic Flowmeter

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Atlas Copco Air motors. A full range of compact, high performance air motors

ISEmax CAS40D. Technical Information

Designed to go where you work

Complete Moisture Analysis

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

792A AC/DC Transfer Standard

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

Digital Thermal Mass Flow Meters and Controllers for Gases

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Pressure transmitters for industrial applications MBS 32 and MBS 33

Conductivity sensor for hygienic applications

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

WM9280. Pro Family weather station with T/H sensor, pluviometer, anemometer, PC connection and Meteotime weather forecasts until 3 days

E THERMADATA LOGGER Humidity & temperature recording meter

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

FVBSS fixed volume bottle

ADI 2040 Process Analyzer

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Mercury Stack Monitor SM-4

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Transcription:

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed air, metal treatment and plastics drying. Features/Benefits Designed for industrial spot checking and field calibration Three models: accurate measurement ranges from -60 to +60 C (-76... +140 F) Vaisala DRYCAP Sensor with patented autocalibration function Low maintenance need due to superior long-term stability Sensor withstands condensation Fast response, enhanced by Sensor Purge option Easy-to-use user interface Data can be logged and transferred to a PC via MI70 Link software Compact, small and light NIST traceable (certificate included) The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 measures dewpoint temperature accurately over a wide measurement range. The probe may be inserted directly into pressurized processes, and it responds rapidly from ambient to process conditions. The sensor withstands condensation and fully recovers from getting wet. Three DMP74 probe models Three probe models, all with autocalibration, are available. The A and B models are both general purpose probes. The A model is for dewpoint range from -40 to +60 C T d, and the B model for -60 to +20 C T d. The C model is specifically developed for SF 6 gas with a dewpoint range down to -50 C T d. The B and C probe models have an additional Sensor Purge feature. The Sensor Purge heats and dries the sensor, making the response from ambient to dry conditions exceptionally fast. This facilitates rapid spot checking measurements in low dewpoints. Low maintenance due to innovative autocalibration The DM70 is fitted with the Vaisala DRYCAP Sensor. The sensor provides reliable and high-performance dewpoint measurement with revolutionary long-term stability. The patented autocalibration procedure detects on-line possible measurement inaccuracies and automatically corrects dry-end drift in the calibration curve. These advanced features provide a long calibration interval and low maintenance cost. The meter is calibrated in the factory against internationally traceable standards and delivered with a calibration certificate. The DM70 can also be sent to a Vaisala Service Center for a traceable recalibration. Easy-to-use user interface The DM70 has a versatile and easy-touse, menu-based user interface and a clear graphical LCD display with datalogger function. It can also be used as a tool for reading the output of fixed Vaisala dewpoint transmitters, like the DMT242, DMT142 and DMT340. Various display variables The DM70 displays one to three parameters at a time, either numerically or graphically. Several humidity units can be selected. In addition, the DM70 includes conversion from gas pressure dewpoint to ambient pressure dewpoint. An analog output is also available. The graphical display helps the user to know when the dewpoint plateau is reached. 64

DM70 DEWPOINT Technical Portable Sampling Data System and s MI70 Link PC connection The DM70 has a MI70 Link Windows software program. In combination with a USB connection cable it's an excellent tool for transferring logged and real time measurement data from the DM70 to a PC. Lightweight construction The DM70 is small and rugged, and therefore an ideal choice for demanding applications. The long or with the Vaisala DRYCAP Sampling System DSS70A. DSS70A portable sampling system The DSS70A is designed to provide dewpoint sampling flexibility. For processes at atmospheric pressure, a battery powered pump is used to extract a gas sample. For pressurized processes up to 20 bar, the sample is measured at process pressure and then reduced to atmospheric pressure for venting or re-direction, bypassing the pump. In all cases, the sample gas passes through a filter to remove particulate contamination before measurement. Flow through the system is controlled and monitored with a needle valve and flow meter. The DSS70A is easily connected to an appropriate sample point with tubing (typically 1/4" or 6 mm). The measured dewpoint must be below ambient temperature to avoid condensation in the system. Gas temperatures higher than +40 C (+104 F) should be cooled with a short PTFE or stainless steel tube prior to entering the DSS70A. Sampling cells for pressurized processes The DM70 can easily be connected to pressurized processes. In addition to direct pipeline installation, a variety of sampling cell options are available for gas sampling. The DSC74 sampling cell is the recommended choice. It has a variety of connection adapters that allow several different ways of installation. The quick connector with a leak screw allows a very fast connection for compressed air lines. Additionally, two thread adapters are available for the inlet port. The is a two-pressure sampling cell, which enables measurements in both process and ambient pressure. This sampling cell is especially suitable for dewpoint measurements in SF 6 gas with the DMP74C probe. The DMT242SC is a basic sampling cell. The DMT242SC2 is a sampling cell supplied with welded Swagelok connectors for sampling in a 1/4" pipeline. The DSS70A provides a compact solution for field checking dewpoint where direct measurement is difficult. Typical applications for the sampling system are metal treatment and plastics drying processes. battery life provides convenient use in the field. DM70 Accessories The DM70 meter is suitable for direct dewpoint measurements in the process in a wide temperature and pressure range. For more demanding applications, the DM70 can be used with the Vaisala sampling cell adapters, The sampling cells (from the left) DMT242SC2, DMT242SC and DSC74 can be used to connect the DM70 to sample gas flow. The (right) is a two-pressure sampling cell that can be used for measurements in either pressurized or ambient pressure. The cooling/venting coil is included in the DSC74C sample cell, but is an option for all sampling cells. 65

Technical Data DSS70A Sampling System and /C s Sample Gas Inlet The DSS70A sampling system includes a filter to clean the dirty sample gas and a needle valve to control the sample flow rate with the flow meter. A sample pump is used to generate a sample flow from processes at ambient pressure. Measurement in gas pressure inlet Measurement in atmospheric pressure inlet Filter DSS70A Removable flow limiter DSC74C Needle Valve Valve Valve Flow meter Removable flow limiter Sample Pump Diffusion coil outlet Sample Gas Outlet outlet The sampling cell enables the measurement of the sampled gas either in gas pressure up to 10 bar or in atmospheric pressure depending on the gas inlet and outlet. The DSC74C is like the but with an additional coil to avoid back diffusion, the effect of surrounding moisture, in dewpoint measurements in atmospheric pressure. DM70 hand-held dewpoint meter (DMP74 probe + MI70 indicator) General Battery operation time continuous use 48 h typical at +20 C (+68 F) data logging use up to 30 days Housing materials ABS/PC blend Storage temperature -40...+70 C Storage humidity 0...100 %RH non-condensing Total weight 750 g Accessories Connection cables for fixed Vaisala dewpoint transmitters for DMT242 transmitter 27160ZZ for DMT340 series 211339 for DMP248 transmitter 27159ZZ for DMT142 transmitter 211917ZZ USB cable for Mi70 219687 Analog output cable 27168ZZ Windows software, includes PC connection cable MI70LINK 10 m (32.81 ft) extension cable for probe 213107SP MI70 indicator Indicator general Menu languages English, Chinese, Spanish, Russian, French, Japanese, German, Swedish, Finnish Display LCD with backlight Graphic trend display of any parameter Character height up to 16 mm Probe inputs 1 or 2 Power supply Rechargeable NiMH battery pack with AC-POWER or 4xAA size alkalines, type IEC LR6 Analog output 0...1 VDC Output resolution 0.6 mv Data interface RS232 (accessible only with MI70 Link software) Datalogging capacity 2700 points Alarm audible alarm function Operating temperature range -10...+40 C (+14 +104 F) Operating humidity range non-condensing Housing classification IP54 400 g 66

DM70 DEWPOINT Technical Data DMP74 dewpoint probes Measured variables, DMP74A probe Dewpoint Accuracy (A probe) -40...+60 C -50... +60 C (-58... +140 F) ±2 C (±3.6 F) (see graph below) Measured variables, DMP74B and DMP74C (for SF 6 gas) probes Dewpoint Accuracy (B and C probe) -60...+20 C -70... +30 C (-94... +86 F) ±2 C (±3.6 F) (see graph below) Dewpoint accuracy vs. measurement conditions Response time flow rate 0.2 m/s, 1 bar pressure, +20 C (+68 F) 63% [90%] 0 -> -40 C T d (32 -> -40 F T d ) 20 s [120 s] -40 -> 0 C T d (-40 -> 32 F T d ) 10 s [20 s] Dewpoint sensor Vaisala DRYCAP 180S Dewpoint converted to atmospheric pressure Dewpoint range for converted Td (20 bar to 1 bar) with ±2 C (±3.6 F) accuracy -64... +60 C (-83... +140 F) Typical temperature dependence of electronics sensor ±0.2 C (±0.36 F) ±0.005 C/ C (±0.005 F/ F) Pt100 IEC751 1/3 class B ppm volume and ppm weight concentration 40... 200 000 ppm ±(7.3 ppm + 8.3% of reading) Absolute humidity Accuracy Mixing ratio Accuracy Relative humidity RH < 5 % RH > 5 % 0.5... 100 g/m3 (0.2... 40 gr/ft3) ± (0.2 g/m3 + 10% of reading ± (0.1 gr/ft3 + 10% of reading) 0.2... 100 g/kg (2... 700 gr/lbs) ± (0.1 g/kg + 12% of reading ± (0.8 gr/lbs + 12% of reading) 0...100 %RH ±(0.025 %RH + 17.5% of reading) ±(0.8 %RH + 2% of reading) Dewpoint accuracy vs. measurement conditions Dotted line: For DMP74C the ±2 C accuracy range is limited to -50 C T d when used in SF6 gas. Response time flow rate 0.2 m/s, 1 bar pressure, +20 C (+68 F) 63% [90%] 0 -> -60 C T d (32 -> -76 F T d ) 50 s [340 s] -60 -> 0 C T d (-76 -> 32 F T d ) 10 s [20 s] Dewpoint sensor Vaisala DRYCAP 180M Dewpoint converted to atmospheric pressure Dewpoint range for converted Td (20 bar to 1 bar) with ±2 C (±3.6 F) accuracy -80... +20 C (-112... +68 F) ±0.2 C (±0.36 F) Typical temperature dependence of electronics ±0.005 C/ C (±0.005 F/ F) sensor Pt100 IEC751 1/3 class B ppm volume and ppm weight concentration 10... 40 000 ppm < 40 ppm ±(0.5 ppm + 25.4% of reading) > 40 ppm ±(7.3 ppm + 8.3% of reading) Measurement environment, all probe models Pressure DMP74A DMP74B DMP74C 0... 10 bar a (0... 150 psia) Sample flow rate no effect for measurement accuracy General, all probe models Measured gases non-corrosive gases Probe material (wetted parts) Stainless steel (AISI 316L) Sensor protection Sintered filter (AISI 316L) partno: HM47280 Mechanical connection G1/2" ISO228-1 thread with bonded seal ring (U-seal) Housing classification IP65 (NEMA 4) 350 g 67

Technical Data and Dimensions Sampling cells technical data DSC74 sampling cell for pressurized gases 1 MPa (10 bar g, 145 psig) two pressure sampling cell 1 MPa (10 bar g, 145 psig) DSC74C with DMCOIL cooling/venting coil DMCOIL cooling/venting coil DMT242SC sampling cell 10 MPa (100 bar g, 1450 psig) DMT242SC2 sampling cell with Swagelok connectors 4 MPa (40 bar g, 580 psig) Material for all sampling cells stainless steel AISI316 DSS70A sampling system Operating conditions Operating gases air, N 2 and other non-toxic, inert gases Dewpoint range -70 C... T amb (-76 F... T amb ) Inlet/outlet connection 1/4" Swagelok Operating temperature ambient temperature 0... +40 C (32... +104 F) process gas temperature with PTFE tube at +20 C (+68 F) max. +200 C (+392 F) with stainless steel tube specification according to stainless steel tube specification maximum gas temperature at inlet +40 C (+104 F) Operating pressure with pump 0.6... 1.2 bar a (8.7... 17.4 psia) pump disconnected General Battery operation time for pump 8 h continuous use battery can be recharged using DM70 charger Filter 7 mm inline filter cartridge 1/4" Swagelok SS-4F-7 (spare part order no. 210801) Materials wetted parts Stainless steel carrying case ABS plastic Case size (W x D x H) 430 x 330 x 100 mm 5.5 kg (12 lbs) Electromagnetic compatibility Complies with EMC standard EN61326-1, Electrical equipment for measurement, control and laboratory use - EMC requirements; Generic Environment. Dimensions Dimensions in mm (inches) DSC74, same as the body of DMT242SC and DMT242SC2. SW 24mm (0.94) 72 (2.83) 35 (1.38) 32 (1.26) G1/2" 32 (1.26) G1/4" 28.5 (1.22) 18 (0.71) G3/8" (G1/4") 22 (0.87) Cooling/ venting coil MI70 indicator DMP74 probe Cable length 2 m (6.56 ft) 12 m (39.37 ft) cable optional /C DRYCAP is a registered trademark of Vaisala. Specifications subject to change without prior notice. Vaisala Oyj