Chapter 14: Inductor design

Similar documents
R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

15.1 Transformer Design: Basic Constraints. Chapter 15: Transformer design. Chapter 15 Transformer Design

In The Name of GOD. Switched Mode Power Supply

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Part III. Magnetics. Chapter 13: Basic Magnetics Theory. Chapter 13 Basic Magnetics Theory

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

6.3. Transformer isolation

Section 8: Magnetic Components

Switched Mode Power Conversion

Elements of Power Electronics PART I: Bases

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Chapter 3. Steady-State Equivalent Circuit Modeling, Losses, and Efficiency

Switched Mode Power Conversion Prof. L. Umanand Department of Electronics System Engineering Indian Institute of Science, Bangalore

Lecture 17 Push-Pull and Bridge DC-DC converters Push-Pull Converter (Buck Derived) Centre-tapped primary and secondary windings

Chapter 1 Magnetic Circuits

ET4119 Electronic Power Conversion 2011/2012 Solutions 27 January 2012

Review of Basic Electrical and Magnetic Circuit Concepts EE

Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method

ELECTRO MAGNETIC INDUCTION

Lecture Set 1 Introduction to Magnetic Circuits

Force and Displacement Measurement

Chapter 15 Magnetic Circuits and Transformers

Chapter 21. Derivations for the Design Equations

Lecture 30: WED 04 NOV

Chapter 11 AC and DC Equivalent Circuit Modeling of the Discontinuous Conduction Mode

Lecture 24. April 5 th, Magnetic Circuits & Inductance

Mutual Inductance: This is the magnetic flux coupling of 2 coils where the current in one coil causes a voltage to be induced in the other coil.

Scheme I SAMPLE QUESTION PAPER I

Reactor Characteristic Evaluation and Analysis Technologies of JFE Steel

The initial magnetization curve shows the magnetic flux density that would result when an increasing magnetic field is applied to an initially

Cross Regulation Mechanisms in Multiple-Output Forward and Flyback Converters

Design and analysis of the ferrite air-gapped cores for a resonant inductor

magneticsp17 September 14, of 17

Physics 1c Practical, Spring 2015 Hw 3 Solutions

ROEVER COLLEGE OF ENGINEERING & TECHNOLOGY ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ELECTRICAL MACHINES I

Electromagnetic Induction

CERN ACCELERATOR SCHOOL Power Converters. Passive components. Prof. Alfred Rufer

Chapter 7 DC-DC Switch-Mode Converters

EE 3324 Electromagnetics Laboratory

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Suppose two uniform bars meet at an abrupt plane and there is a magnetic field induced by an extended core and coil structure off stage as in:

Measurements in Mechatronic design. Transducers

Tutorial Sheet Fig. Q1

Electromagnetic Induction & Inductors

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM

Mutual Inductance. The field lines flow from a + charge to a - change

9-3 Inductance. * We likewise can have self inductance, were a timevarying current in a circuit induces an emf voltage within that same circuit!

Tutorial Sheet IV. Fig. IV_2.

Different Techniques for Calculating Apparent and Incremental Inductances using Finite Element Method

Introduction to AC Circuits (Capacitors and Inductors)

Revision Guide for Chapter 15

[22.1 (2)(0.42) (3.38 / 2)] At/Wb

Power Electronics

Self-Inductance. Φ i. Self-induction. = (if flux Φ 1 through 1 loop. Tm Vs A A. Lecture 11-1

Modellierung von Kern- und Wicklungsverlusten Jonas Mühlethaler, Johann W. Kolar

9. Mutual Induction Theory

Part 4: Electromagnetism. 4.1: Induction. A. Faraday's Law. The magnetic flux through a loop of wire is

Some Important Electrical Units

ELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT

r where the electric constant

Thermal vs. Power Loss Efficiency Considerations for Powder Core Materials. Christopher Oliver Nien Teng Micrometals, Incorporated

LECTURE 8 Fundamental Models of Pulse-Width Modulated DC-DC Converters: f(d)

ASSOCIATE DEGREE IN ENGINEERING RESIT EXAMINATIONS SEMESTER 1. "Electrical Eng Science"

Electric Circuits I. Inductors. Dr. Firas Obeidat

Inductance, RL Circuits, LC Circuits, RLC Circuits

3 The non-linear elements

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

7.3 State Space Averaging!

Part II Converter Dynamics and Control

Transformer. Transformer comprises two or more windings coupled by a common magnetic circuit (M.C.).

The output voltage is given by,

SYLLABUS(EE-205-F) SECTION-B

Solution for Fq. A. up B. down C. east D. west E. south

EE155/255 Green Electronics

WLPN Series SMD Molded Power Choke Inductors

REVISED HIGHER PHYSICS REVISION BOOKLET ELECTRONS AND ENERGY

Physics 1302W.400 Lecture 33 Introductory Physics for Scientists and Engineering II

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3. OUTCOME 3 - MAGNETISM and INDUCTION

Module 7. Transformer. Version 2 EE IIT, Kharagpur

Electromagnetic Induction

L4970A 10A SWITCHING REGULATOR

Preliminary Sizing Design of a 1 MW Low Duty Cycle Switched Reluctance Generator for Aerospace Applications

Wireless charging using a separate third winding for reactive power supply

IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 22, NO. 1, JANUARY /$ IEEE

B C E. absolute maximum ratings at 25 C ambient temperature (unless otherwise noted )

NR/RR. Set No. 2 CODE NO: NR/RR210204

Transformer Fundamentals

Definition Application of electrical machines Electromagnetism: review Analogies between electric and magnetic circuits Faraday s Law Electromagnetic

Lecture 16.1 :! Final Exam Review, Part 2

RLC Circuit (3) We can then write the differential equation for charge on the capacitor. The solution of this differential equation is

Tactics: Evaluating line integrals

Fachgebiet Leistungselektronik und Elektrische Antriebstechnik. Test Examination: Mechatronics and Electrical Drives

Lecture 4: Losses and Heat Transfer

Conventional Paper-I Part A. 1. (a) Define intrinsic wave impedance for a medium and derive the equation for intrinsic vy

Lecture 15: Inductor & Capacitor

Modelling Non-Ideal Inductors in SPICE

CHAPTER 8 DC MACHINERY FUNDAMENTALS

5. Passive Components

Basic Electrical Technology Prof. Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore

EC Objective Paper I (Set - D)

Transcription:

Chapter 14 Inductor Design 14.1 Filter inductor design constraints 14.2 A step-by-step design procedure 14.3 Multiple-winding magnetics design using the K g method 14.4 Examples 14.5 Summary of key points 1

14.1 Filter inductor design constraints Objective: i L R Design inductor having a given inductance L, which carries worst-case current I max without saturating, and which has a given winding resistance R, or, equivalently, exhibits a worst-case copper loss of P cu = I rms 2 R Example: filter inductor in CCM buck converter L i i I i L + 0 DT s T s t 2

Assumed filter inductor geometry Core reluctance R c Φ i + n v turns Air gap reluctance ni + R g F c + R c Φ R g R c = R g = l c µ c A c l g µ 0 A c Solve magnetic circuit: ni = Φ R c + R g Usually R c < R g and hence ni ΦR g 3

14.1.1 Constraint: maximum flux density Given a peak winding current I max, it is desired to operate the core flux density at a peak value B max. The value of B max is chosen to be less than the worst-case saturation flux density B sat of the core material. From solution of magnetic circuit: ni = BA c R g Let I = I max and B = B max : ni max = B max A c R g = B max l g µ 0 This is constraint #1. The turns ratio n and air gap length l g are unknown. 4

14.1.2 Constraint: inductance Must obtain specified inductance L. We know that the inductance is L = n2 R g = µ 0A c n 2 l g This is constraint #2. The turns ratio n, core area A c, and air gap length l g are unknown. 5

14.1.3 Constraint: winding area Wire must fit through core window (i.e., hole in center of core) core Total area of copper in window: na W Area available for winding conductors: wire bare area A W core window area W A K u W A Third design constraint: K u W A na W 6

The window utilization factor K u also called the fill factor K u is the fraction of the core window area that is filled by copper Mechanisms that cause K u to be less than 1: Round wire does not pack perfectly, which reduces K u by a factor of 0.7 to 0.55 depending on winding technique Insulation reduces K u by a factor of 0.95 to 0.65, depending on wire size and type of insulation Bobbin uses some window area Additional insulation may be required between windings Typical values of K u : 0.5 for simple low-voltage inductor 0.25 to 0.3 for off-line transformer 0.05 to 0.2 for high-voltage transformer (multiple kv) 0.65 for low-voltage foil-winding inductor 7

14.1.4 Winding resistance The resistance of the winding is R = ρ l b A W where is the resistivity of the conductor material, l b is the length of the wire, and A W is the wire bare area. The resistivity of copper at room temperature is 1.724 10 6 -cm. The length of the wire comprising an n-turn winding can be expressed as l b = n (MLT) where (MLT) is the mean-length-per-turn of the winding. The meanlength-per-turn is a function of the core geometry. The above equations can be combined to obtain the fourth constraint: R = ρ n (MLT) A W 8

14.1.5 The core geometrical constant K g The four constraints: ni max = B max A c R g = B max l g µ 0 L = n2 R g = µ 0A c n 2 l g K u W A na W R = ρ n (MLT) A W These equations involve the quantities A c, W A, and MLT, which are functions of the core geometry, I max, B max, µ 0, L, K u, R, and, which are given specifications or other known quantities, and n, l g, and A W, which are unknowns. Eliminate the three unknowns, leading to a single equation involving the remaining quantities. 9

Core geometrical constant K g Elimination of n, l g, and A W leads to A 2 c W A (MLT) ρl2 2 I max 2 B max RK u Right-hand side: specifications or other known quantities Left-hand side: function of only core geometry So we must choose a core whose geometry satisfies the above equation. The core geometrical constant K g is defined as K g = A c 2 W A (MLT) 10

Discussion K g = A 2 cw A (MLT) ρl2 2 I max 2 B max RK u K g is a figure-of-merit that describes the effective electrical size of magnetic cores, in applications where the following quantities are specified: Copper loss Maximum flux density How specifications affect the core size: A smaller core can be used by increasing B max use core material having higher B sat R allow more copper loss How the core geometry affects electrical capabilities: A larger K g can be obtained by increase of A c more iron core material, or W A larger window and more copper 11

14.2 A step-by-step procedure The following quantities are specified, using the units noted: Wire resistivity ( -cm) Peak winding current I max (A) Inductance L (H) Winding resistance R ( ) Winding fill factor K u Core maximum flux density B max (T) The core dimensions are expressed in cm: Core cross-sectional area A c (cm 2 ) Core window area W A (cm 2 ) Mean length per turn MLT (cm) The use of centimeters rather than meters requires that appropriate factors be added to the design equations. 12

Determine core size K g ρl2 2 I max 2 10 8 (cm 5 ) RK u B max Choose a core which is large enough to satisfy this inequality (see Appendix D for magnetics design tables). Note the values of A c, W A, and MLT for this core. 13

Determine air gap length l g = µ 2 0LI max 2 10 4 A c B max (m) with A c expressed in cm 2. µ 0 = 4 10 7 H/m. The air gap length is given in meters. The value expressed above is approximate, and neglects fringing flux and other nonidealities. 14

A L Core manufacturers sell gapped cores. Rather than specifying the air gap length, the equivalent quantity A L is used. A L is equal to the inductance, in mh, obtained with a winding of 1000 turns. When A L is specified, it is the core manufacturer s responsibility to obtain the correct gap length. The required A L is given by: A L = 10B 2 max 2 (mh/1000 turns) LI max L = A L n 2 10 9 A c 2 (Henries) Units: A c cm 2, L Henries, B max Tesla. 15

Determine number of turns n n = LI max B max A c 10 4 16

Evaluate wire size A W K uw A n (cm 2 ) Select wire with bare copper area A W less than or equal to this value. An American Wire Gauge table is included in Appendix D. As a check, the winding resistance can be computed: R = ρn (MLT) A w (Ω) 17

14.3 Multiple-winding magnetics design using the K g method The K g design method can be extended to multiplewinding magnetic elements such as transformers and coupled inductors. This method is applicable when Copper loss dominates the total loss (i.e. core loss is ignored), or The maximum flux density B max is a specification rather than a quantity to be optimized To do this, we must Find how to allocate the window area between the windings Generalize the step-by-step design procedure 18

14.3.1 Window area allocation Given: application with k windings having known rms currents and desired turns ratios v 1 n 1 = v 2 n 2 = = v k n k rms current I 1 n 1 : n 2 rms current I 2 Core Window area W A Core mean length per turn (MLT) Wire resistivity ρ Fill factor K u : n k rms current I k Q: how should the window area W A be allocated among the windings? 19

Allocation of winding area Winding 1 allocation α 1 W A Winding 2 allocation α 2 W A etc. { { Total window area W A 0<α j <1 α 1 + α 2 + + α k =1 20

Copper loss in winding j Copper loss (not accounting for proximity loss) is P cu, j = I j 2 R j Resistance of winding j is R j = ρ l j A W,j with l j = n j (MLT) A W, j = W AK u α j n j length of wire, winding j wire area, winding j Hence R j = ρ n2 j (MLT) W A K u α j P cu,j = n j 2 i j 2 ρ(mlt) W A K u α j 21

Total copper loss of transformer Sum previous expression over all windings: P cu,tot = P cu,1 + P cu,2 + + P cu,k = ρ (MLT) W A K u k Σj =1 n 2 2 j I j α j Need to select values for 1, 2,, k such that the total copper loss is minimized 22

Variation of copper losses with 1 Copper loss Pcu,1 P cu,tot P cu,2 + P cu,3 +...+ P cu,k For 1 = 0: wire of winding 1 has zero area. P cu,1 tends to infinity For 1 = 1: wires of remaining windings have zero area. Their copper losses tend to infinity 0 1 α 1 There is a choice of 1 that minimizes the total copper loss 23

Method of Lagrange multipliers to minimize total copper loss Minimize the function P cu,tot = P cu,1 + P cu,2 + + P cu,k = ρ (MLT) W A K u k Σj =1 n 2 2 j I j α j subject to the constraint α 1 + α 2 + + α k =1 Define the function where f (α 1, α 2,, α k, ξ)=p cu,tot (α 1, α 2,, α k )+ξ g(α 1, α 2,, α k ) g(α 1, α 2,, α k )=1 α j Σj =1 is the constraint that must equal zero and is the Lagrange multiplier k 24

Lagrange multipliers continued Optimum point is solution of the system of equations f (α 1, α 2, α 1, α k,ξ) =0 f (α 1, α 2, α 2, α k,ξ) =0 Result: ξ = ρ (MLT) W A K u α m = n mi m Σ n j I j n =1 k Σj =1 n j I j 2 = P cu,tot f (α 1, α 2, α k, α k,ξ) =0 f (α 1, α 2, ξ, α k,ξ) =0 An alternate form: α m = V mi m Σ V j I j n =1 25

Interpretation of result α m = V mi m Σ V j I j n =1 Apparent power in winding j is where V j I j V j is the rms or peak applied voltage I j is the rms current Window area should be allocated according to the apparent powers of the windings 26

Example PWM full-bridge transformer i 1 i 2 I n 1 turns { } n 2 turns } n 2 turns i 1 n 2 n 1 I i 3 0 0 Note that waveshapes (and hence rms values) of the primary and secondary currents are different Treat as a threewinding transformer i 2 i 3 I 0 n 2 n 1 I 0.5I 0.5I 0 I 0.5I 0.5I 0 DT s T s T s +DT s 2T s t 27

Expressions for RMS winding currents i 1 n 2 n 1 I I 1 = 1 2Ts I 2 = I 3 = 1 2Ts see Appendix A 0 2T s i 2 1 dt = n 2 I n 1 0 D 2T s i 2 2 dt = 1 2 I 1+D i 2 i 3 I 0 0 0 n 2 n 1 I 0.5I 0.5I 0 I 0.5I 0.5I 0 DT s T s T s +DT s 2T s t 28

Allocation of window area: α m = V mi m Σ V j I j n =1 Plug in rms current expressions. Result: α 1 = 1 1+ 1+D D Fraction of window area allocated to primary winding α 2 = α 3 = 1 2 1 1+ D 1+D Fraction of window area allocated to each secondary winding 29

Numerical example Suppose that we decide to optimize the transformer design at the worst-case operating point D = 0.75. Then we obtain α 1 = 0.396 α 2 = 0.302 α 3 = 0.302 The total copper loss is then given by P cu,tot = ρ(mlt) W A K u 3 Σj =1 n j I j 2 = ρ(mlt)n 2 2 I 2 W A K u 1+2D +2 D(1 + D) 30

14.3.2 Coupled inductor design constraints Consider now the design of a coupled inductor having k windings. We want to obtain a specified value of magnetizing inductance, with specified turns ratios and total copper loss. i 1 + v 1 i M L M n 1 : n 2 + v 2 i 2 Magnetic circuit model: R c R 1 R 2 n 1 i M + Φ R g + v k i k : n k R k 31

14.4 Examples 14.4.1 Coupled Inductor for a Two-Output Forward Converter 14.4.2 CCM Flyback Transformer 32

14.4.2 Example 2: CCM flyback transformer i M Transformer model I M i M V g i 1 i M + L M + v M n 1 : n 2 D 1 i 2 C R + V 0 i 1 I M 0 i 2 Q 1 n 1 n 2 I M 0 v M V g 0 DT s 33

Specifications Input voltage V g = 200V Output (full load) 20 V at 5 A Switching frequency 150 khz Magnetizing current ripple 20% of dc magnetizing current Duty cycle D = 0.4 Turns ratio n 2 /n 1 = 0.15 Copper loss 1.5 W Fill factor K u = 0.3 Maximum flux density B max = 0.25 T 34

Basic converter calculations Components of magnetizing current, referred to primary: I M = n 2 n 1 1 D V R = 1.25 A RMS winding currents: I 1 = I M D 1+ 1 3 i M I M 2 = 0.796 A i M = 20% I M = 0.25 A I 2 = n 1 n 2 I M D 1+ 1 3 i M I M 2 = 6.50 A I M,max = I M + i M = 1.5 A Choose magnetizing inductance: I tot = I 1 + n 2 n 1 I 2 = 1.77 A L M = V g DT s 2 i M = 1.07 mh 35

Choose core size K g ρl 2 MI 2 2 tot I M,max 2 10 8 P cu K u B max = 1.724 10 6 Ω-cm 1.07 10 3 H 2 1.77 A 2 1.5 A 2 = 0.049 cm 5 0.25 T 2 1.5 W 0.3 10 8 The smallest EE core that satisfies this inequality (Appendix D) is the EE30. 36

Choose air gap and turns l g = µ 2 0L M I M,max 2 10 4 A c B max = 4π 10 7 H/m 1.07 10 3 H 1.5 A 2 0.25 T 2 1.09 cm 2 10 4 =0.44mm n 1 = L MI M,max B max A c 10 4 = 1.07 10 3 H 1.5 A 0.25 T 1.09 cm 2 10 4 = 58.7 turns Round to n 1 =59 37 n 2 = n 2 n 1 n 1 = 0.15 59 = 8.81 n 2 =9

Wire gauges α 1 = I 1 I tot = 0.796 A 1.77 A = 0.45 α 2 = n 2I 2 n 1 I tot = 9 6.5 A 59 1.77 A = 0.55 A W1 α 1K u W A n 1 = 1.09 10 3 cm 2 use #28 AWG A W2 α 2K u W A n 2 = 8.88 10 3 cm 2 use #19 AWG 38

Core loss CCM flyback example B-H loop for this application: B The relevant waveforms: B B sat B max B B max B V g H c Minor B H loop, CCM flyback example 0 v M 0 n 1 A c V g DT s B H loop, large excitation B vs. applied voltage, from Faraday s law: db dt = v M n 1 A c For the first subinterval: db dt = V g n 1 A c 39

Calculation of ac flux density and core loss Solve for B: B = V g n 1 A c DT s Plug in values for flyback example: 200 V 0.4 6.67 µs B = 10 4 259 1.09 cm 2 =0.041 T From manufacturer s plot of core loss (at left), the power loss density is 0.04 W/cm 3. Hence core loss is P fe = 0.04 W/cm 3 A c l m = 0.04 W/cm 3 1.09 cm 2 5.77 cm = 0.25 W 40 Power loss density, Watts/cm 3 1 0.1 0.04 W/cm 3 400kHz 200kHz 150kHz 100kHz 50kHz 20kHz 0.01 0.01 0.1 0.3 0.041 B, Tesla

Comparison of core and copper loss Copper loss is 1.5 W does not include proximity losses, which could substantially increase total copper loss Core loss is 0.25 W Core loss is small because ripple and B are small It is not a bad approximation to ignore core losses for ferrite in CCM filter inductors Could consider use of a less expensive core material having higher core loss Neglecting core loss is a reasonable approximation for this application Design is dominated by copper loss The dominant constraint on flux density is saturation of the core, rather than core loss 41

14.5 Summary of key points 1. A variety of magnetic devices are commonly used in switching converters. These devices differ in their core flux density variations, as well as in the magnitudes of the ac winding currents. When the flux density variations are small, core loss can be neglected. Alternatively, a low-frequency material can be used, having higher saturation flux density. 2. The core geometrical constant K g is a measure of the magnetic size of a core, for applications in which copper loss is dominant. In the K g design method, flux density and total copper loss are specified. 42