Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

Similar documents
Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (2015) by GPC-GC-MS/MS

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Highly Sensitive and Rugged GC/MS/MS Tool

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) tandem mass spectrometry

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Pure Chromatography. Food Safety Applications. Abstract. Introduction

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Analysis of Pesticides and Contaminants using HS-SPME-GC/MS and DRS Detection. Blair Surridge, Tyler Dyer, Rene Bilideau, Paloma Bertolin Presoti

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Multi-residue analysis of pesticides by GC-HRMS

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

Benzodiazepines and Barbiturates

Determination of 59 potential Allergens in Perfumes by twin-line fast GCMSMS

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique

Improved GC/MS Analysis of Tomato Pesticides with Agilent Deactivated Silica Tubing

Multiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application

Overview. Introduction

Gas Chromatograph Mass Spectrometer GCMS-TQ8040 C146-E251

LC-MS/MS multiresidue method used for pesticides analysis in fruits and vegetables

Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Pittcon P

Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Application Note No Introduction. DMI Instrumentation. DMI Method. DMI for Lettuce and Pea Extracts. Lettuce results

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Advanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues

Fast and Accurate Quantitation of Perfluorinated Sources from Textiles using Gas Chromatography-Triple Quadrupole Mass Spectrometry

The Analysis of Organophosphate Pesticides by LC/MS Application

Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables.

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Triumphs and Challenges of High-Resolution Mass Spectrometry in Comprehensive Residue Screens

USEPA Methods 8270 and 8260 on a Single GCMS Without Changing Columns

High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

U.S. EPA Method 8270 for multicomponent analyte determination

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Validation Report Determination of isoprothiolane residues in rice by GC-MS/MS (QuEChERS method)

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

Higher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer)

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer

Analytical Test Report 10

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Author. Abstract. Introduction

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis

Validation Report 3 Determination of pesticide residues in cereals by GC-MS/MS (QuEChERS method)

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Validation Report 18

Three-Fold Increase in Productivity for Pesticide Residue Analysis in Baby Food Using Fast Triple Quadrupole GC-MS/MS

Screening for Hundreds of Pesticide Residues Using a GC/Q-TOF with an Exact Mass Pesticide Database in Food

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

The Pulsed Flame Photometric Detector for analysis of phosphorus pesticides in wastewater and food commodities

Fast and Accurate Analysis of Fluorotelomer Alcohols and Acrylates using Triple Quadrupole GC-MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

Validation Report 5 Determination of pesticide residues in cereals by GC-MS/MS (QuEChERS method)

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Identifying Disinfection Byproducts in Treated Water

Safeguarding Food from Pesticides by UHPLC After Extraction with the QuEChERS Method

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

ENVIRONMENTAL analysis

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Low level quantification of NDMA and non-targeted contaminants screening in drinking water using GC Orbitrap mass spectrometry

Transcription:

Gas Chromatograph Mass Spectrometer No. GCMS-1404 Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030 Introduction Contamination of consumer products with pesticides is a growing concern because of recognized adverse health effects, increasing world-wide usage of pesticides, and imports of raw materials from foreign sources. Citrus oils have been used for centuries for a wide range of applications: flavor/fragrance, various medicinal purposes, and others. In recent years, new uses of citrus oils as cleaners and in aromatherapy and alternative medicine have become widespread. Gas chromatography mass spectrometry (GCMS) has been used extensively to identify and quantify trace level pesticides in food and related matrices; the most significant challenges have been matrix interference and achievement of meaningful health-based detection limits for the compounds of interest. Triple quadrupole GC-MS/MS has emerged as a technique of choice for analysis of trace level contaminants in complex matrices. Operation of the triple quadrupole GC-MS/MS in the Multiple Reaction Monitoring (MRM) mode provides excellent sensitivity and specificity for detection and quantitation of target pesticides at low concentrations in the presence of background interferences. Most co-extracted matrix interferences are minimized using the MRM mode. The outstanding selectivity of the MRM mode has been illustrated previously. 1 This application note presents instrument configuration, operating parameters, and analytical results for analysis of trace levels of 47 pesticides of various chemical classes in four orange oil samples using the Shimadzu GCMS-TQ8030 triple quadrupole GC-MS/MS (Figure 1). Results were evaluated for calibration linearity, analytical precision, sensitivity, and specificity. Figure 1: Shimadzu GCMS-TQ8030 Triple Quadrupole GC/MS/MS

Experimental The analyses were conducted using a Shimadzu GCMS-TQ8030 triple quadrupole GC/MS/MS operated in the multiple reaction monitoring (MRM) mode. Optimized MRM transitions and collision energies were obtained from three sources: 1. The Shimadzu GC/MS/MS Pesticide Database 1 2. Previous application studies of trace level pesticides 2,3 3. Empirical determination using the Shimadzu GCMS-TQ8030 with Smart MRM The GCMS-TQ8030 allows optimization of the collision energy for each MRM transition, providing ultimate sensitivity. In addition, the Q1 and Q3 resolution can be independently defined for each compound, to deliver individualized specificity for each analyte. The instrument configuration and operating conditions are shown in Table 1A below; MRM transitions, optimized collision energies, and Q1/Q3 resolution settings for the 47 pesticide analytes, one internal standard (IS), and one control are shown in Table 1B. The analytical method for detection of the target pesticides was developed using the Shimadzu GC-MS/MS Pesticide Database for the GCMS-TQ8030. Method information for 430 pesticides includes suggested MRM transitions that can be used for either quantitation or confirmation. MRM transitions were determined experimentally for pesticides not registered in the database. The Shimadzu GC/MS/MS Pesticide Database for the GCMS-TQ8030 has been described previously. Table 1A: GCMS-TQ8030 Instrument Conditions for Analysis of Pesticides in Orange Oil Gas Chromatograph Inlet Column Oven Program Mass Spectrometer Ion Source Operation Mode 250 C Single-taper gooseneck splitless liner with glass wool (Restek 23322.5) Splitless injection, sampling time 1 minute Rxi-5Sil MS, 30 m x 0.25 mm x 0.25 µm (Restek 13623) Helium carrier gas Constant linear velocity 47 cm/second 75 C, hold 1 minute 10 C/minute to 320 C, hold 4.5 minutes MS interface 320 C 200 C Electron ionization (EI) mode, 70 ev Simultaneous Scan/MRM Argon gas, 200 kpa Q1, Q3 resolution: Unit, Unit Table 1B: Pesticide Analytes with MRM Transition and Q1/Q3 Resolution Details Compound Name MRM-1 CE-1 MRM-2 CE-2 MRM-3 CE-3 Q1/Q3 Resolution 2,4-D methyl ester 234.1>199.1 10 234.1>73.1 12 234.1>175.1 14 Unit/Unit Phendimedipham 167.1>135.1 8 167.1>122.1 14 167.1>59.0 18 Unit/Unit Monocrotophos 127.1>109.0 12 127.1>95.0 16 127.1>79.0 20 Unit/Unit Cadusafos 158.9>130.9 8 158.9>97.0 18 158.9>65.0 28 Unit/Unit Dimethoate 125.0>79.0 8 125.0>47.0 14 125.0>62.0 10 Unit/Unit Carbofuran 164.1>149.1 8 164.1>131.1 18 164.1>103.1 24 Unit/Unit Diazinon 304.1>179.1 10 304.1>162.1 8 304.1>137.1 26 Unit/Unit

Pyrimethanil 198.1>183.1 14 198.1>158.1 18 198.1>118.1 28 Unit/Unit Parathion-methyl 263.0>109.0 14 263.0>136.0 8 263.0>246.0 6 Unit/Unit Carbaryl 144.1>116.1 12 144.1>89.0 38 144.1>65.0 28 Unit/Unit Metalaxyl (Mefenoxam) 249.2>190.1 8 249.2>146.1 22 249.2>217.1 6 Unit/Unit Primiphos-methyl 305.1>180.1 6 305.1>290.1 12 305.1>125.0 26 Unit/Unit Methiocarb 168.1>153.0 8 168.1>109.0 14 168.1>45.0 22 Unit/Unit Malathion 173.1>99.0 14 173.1>127.0 6 173.1>145.0 6 Unit/Unit Chlorpyrifos 313.9>257.9 14 313.9>285.9 8 313.9>193.9 28 Unit/Unit Fenthion 278.0>109.0 20 278.0>125.0 20 278.0>169.0 14 Unit/Unit Parathion 291.1>109.0 14 291.1>137.0 6 291.1>81.0 24 Unit/Unit Kelthane (Dicofol) 250.1>139.1 12 250.1>215.1 4 250.1>111.1 30 Unit/Unit Triphenylmethane (IS) 244.1>167.1 10 244.1>243.1 10 Unit/Unit Pendimethalin (Penoxaline) 252.1>162.1 10 252.1>191.1 8 252.1>208.1 6 Unit/Unit Phenthoate 273.9>125.0 20 273.9>246.0 6 273.9>93.0 14 Unit/Unit Thiabendazole 201.1>174.1 16 201.1>130.1 26 201.1>92.0 28 Unit/Unit Methidathion 145.0>85.0 8 145.0>58.0 14 145.0>71.0 6 Unit/Unit Napropamide 128.1>72.0 6 128.1>57.0 12 128.1>100.0 8 Unit/Unit Imazalil 215.00>173.0 6 215.0>159.0 6 215.0>145.0 26 Unit/Unit Pymetrozine 113.2>98.2 11 113.2>70.0 23 0 Unit/Unit 2,4-D ethylhexyl ester 332.1>220.1 9 332.1>162.1 24 332.1>57.2 22 Unit/Unit Fenthion sulfone 310.1>109.1 20 310.1>136.1 16 310.1>105.2 12 Unit/Unit Ethion 231.0>174.9 23 231.0>203.0 16 231.0>185.0 15 Unit/Unit Triazophos 257.0>162.0 8 257.0>134.0 22 257.0>119.0 26 Unit/Unit Trifloxystrobin 222.1>190.1 4 222.1>162.1 10 222.1>130.1 12 Unit/Unit Triphenyl Phosphate (Control) 326.1>170.1 15 326.1>215.1 20 Unit/Unit Propargite-1 135.1>107.1 16 135.1>77.0 24 135.1>95.0 14 Unit/Unit Pyridaphenthion 340.0>199.1 8 340.0>109.1 22 340.0>125.1 20 Unit/Unit Acetamiprid 152.0>116.0 18 152.0>89.0 26 152.0>125.0 14 Unit/Unit Imidan (Phosmet) 160.0>133.0 14 160.0>77.0 24 160.0>105.0 18 Unit/Unit Fenoxycarb 186.1>109.1 14 186.1>129.1 14 186.1>81.0 26 Unit/Unit Bromopropylate 340.9>157.0 30 340.9>184.9 20 340.9>182.9 18 Unit/Unit Fenpropathrin 265.1>210.1 12 265.1>172.1 14 265.1>89.0 28 Unit/Unit Tetradifon 355.9>228.9 12 355.9>159.0 18 355.9>127.0 16 Unit/Unit

Azinphos-methyl 160.1>132.1 6 160.1>77.0 20 160.1>51.0 28 Unit/Unit Pyriproxyfen 136.1>78.0 20 136.1>96.0 14 136.1>108.0 6 Unit/Unit Spirodiclofen 312.0>109.0 20 312.0>277.0 6 312.0>259.0 12 Unit/Unit Pyridaben 147.1>117.1 22 147.1>132.1 14 147.1>119.1 10 Unit/Unit Prochloraz 180.1>138.1 12 180.1>69.0 20 180.1>95.0 20 Unit/Unit Fenbuconazole 198.1>129.1 10 198.1>102.1 24 198.1>78.0 28 Unit/Unit Pyraclostrobin 164.1>132.1 14 164.1>77.0 28 164.1>104.1 26 Unit/Unit Azoxystrobin 344.1>183.1 24 344.1>329.1 16 344.1>156.1 32 Unit/Unit Famoxadone 330.1>224.1 10 330.1>196.1 22 330.1>237.1 10 Unit/Unit Calibration employed the matrix-matched internal standard procedure. A sample of organic orange oil was used as the sample matrix; an organic variety was selected so it would be free from background pesticide contamination. The samples were diluted 10-fold into methylene chloride for analysis; no other pretreatment or cleanup of the samples was attempted in this study. Concentrations are expressed in ng/ml (parts-per-billion, ppb) in the original sample. Results and Discussion Chromatography The total ion chromatogram (TIC) of the pesticide standard (20 µg/ml in methylene chloride) acquired in the Q3 full-scan mode is shown in Figure 2A, and illustrates the chromatographic separation of the target pesticides in this study. A full-scan chromatogram of the organic orange oil acquired under the same conditions is shown in Figure 2B, and shows a broad, intense signal for limonene before 7.5 minutes, intense chromatographic peaks from 7.5-12 minutes, and illustrates the significant matrix interference in the raw orange oil. Figure 2A: Total Ion Chromatogram of Pesticide Standard Q3 Scan Mode

Limonene Figure 2B: Total Ion Chromatogram of Organic Orange Oil Q3 Scan Mode Calibration and Assessment of Precision Calibration employed the matrix-matched internal standard procedure. Nine calibration standards were prepared in diluted organic orange oil over the range of 5-5000 ng/ml (ppb) expressed as concentration in the original orange oil (corresponding to mass of 0.5-500 pg on column for each analyte). Triphenylmethane was used as the internal standard and was held at a constant concentration of 500 ng/ml; triphenyl phosphate was used as a control standard, and was also held at a constant concentration of 500 ng/ml in all standards. The calibration standards were analyzed using the instrument conditions outlined in Table 1 above. The detector (electron multiplier) was adjusted to give acceptable response at the lowest calibration level and avoid saturation at the highest calibration level. Response factors were calculated and relative standard deviation (RSD) was determined by the GCMSsolution software. response factors for the initial calibration are presented in Table 2 below. The precision of the calibration was evaluated using the RSD of the response factors and the correlation coefficient (r) for each of the analytes. The RSD and correlation coefficient values for the multi-point calibration(s) are also included in Table 2. Linearity as evaluated by the correlation coefficient was acceptable for the multi-point calibration. In cases where the RSD for the response factors was greater than 20%, chromatographic interferences contributed to the signal for the lowest concentration standards. Matrix interference for some compounds was significant at the lowest calibration ranges, so lower calibration levels were omitted and the calibration range was adjusted accordingly. The lowest calibration point for each compound is listed in Table 2. For the purpose of this study, the level of quantitation (LOQ) is defined as the lowest point in the multi-point calibration. After the multi-point calibration, ten replicate injections of the 5, 10, and 50 ng/ml standards were analyzed to assess the precision and accuracy of measurement near the low end of the calibration range. The mean concentration and RSD for the replicate analyses are presented in Table 2. In cases where the spike level fell below the LOQ for a compound, precision data are not presented (e.g. the LOQ for Cadusafos is 50 ppb, so spike results are not presented for the 5 and 10 ppb spikes).

Table 2: Calibration, Precision, and Accuracy Results for Pesticides in Orange Oil Compound Name RRF Calibration Results 5 ppb Spike 10 ppb Spike 50 ppb Spike RRF %RSD Linear ity (r) Low Cal (ppb) Conc. %RSD Conc. %RSD Conc. 2,4-D methyl ester 0.511 12 >0.999 5 9 11.1 7 53 2 9 Phendimedipham 0.509 14 >0.999 100 xxx xxx xxx 57 5 xxx Monocrotophos 1.463 2 >0.999 10 xxx 12.8 4 46 2 xxx Cadusafos 1.366 15 >0.999 50 xxx xxx xxx 53 6 xxx Dimethoate 0.169 3 >0.999 50 xxx xxx xxx 47 7 xxx Carbofuran 0.940 28 >0.999 50 xxx xxx xxx 61 6 xxx Diazinon 0.441 5 >0.999 5 9 10.9 8 53 4 9 Pyrimethanil 0.434 11 >0.999 5 5 10.1 7 52 3 5 Parathion-methyl 0.089 11 >0.999 50 xxx xxx xxx 58 2 xxx Carbaryl 1.950 18 >0.999 5 7 13.9 4 56 3 7 Metalaxyl (Mefenoxam) 0.388 9 >0.999 50 xxx xxx xxx 60 12 xxx Primiphos-methyl 0.271 5 >0.999 5 12 10.6 6 52 3 12 Methiocarb 1.404 3 >0.999 50 xxx xxx xxx 60 4 xxx Malathion 1.232 17 >0.999 50 xxx xxx xxx 80 2 xxx Chlorpyrifos 0.272 22 >0.999 5 10 13.6 9 54 6 10 Fenthion 1.200 12 >0.999 5 7 11.7 5 53 1 7 Parathion 0.430 5 >0.999 5 12 10.6 4 47 3 12 Kelthane (Dicofol) 0.627 15 >0.999 5 5 12.1 5 53 3 5 Triphenylmethane (IS) NA NA NA NA N/A NA NA NA NA N/A Pendimethalin (Penoxaline) 0.364 10 >0.999 5 14 8.4 7 43 3 14 Phenthoate 0.788 13 >0.999 5 2 12.2 2 54 2 2 Thiabendazole 3.004 5 >0.999 5 8 12.3 17 49 5 8 Methidathion 3.066 3 >0.999 10 xxx 15.9 3 56 1 xxx Napropamide 0.515 4 >0.999 50 xxx xxx xxx 54 5 xxx Imazalil 0.758 4 >0.999 5 15 10.3 10 48 3 15 Pymetrozine 0.808 8 >0.999 5 19 9.6 10 47 5 19 2,4-D ethylhexyl ester 0.086 8 >0.999 10 xxx 7.7 13 47 10 xxx Fenthion sulfone 0.422 13 >0.999 5 14 10.7 6 52 3 14 Ethion 0.440 14 >0.999 5 6 12.9 8 55 2 6 Triazophos 0.772 7 >0.999 5 11 11.5 3 51 2 11 Trifloxystrobin 0.405 7 >0.999 5 9 10.1 7 49 4 9 Triphenyl Phosphate (Control) %RSD 0.666 1 >0.999 NA N/A N/A N/A N/A N/A N/A Propargite-1 1.155 12 >0.999 100 xxx xxx xxx xxx xxx xxx Pyridaphenthion 0.802 6 >0.999 5 7 11.3 8 52 2 7 Acetamiprid 0.438 7 >0.999 10 xxx 8.3 11 45 4 xxx Imidan (Phosmet) 2.174 17 >0.999 5 7 14.4 6 52 2 7 Fenoxycarb 0.265 16 >0.999 10 xxx 16.0 9 58 3 xxx Bromopropylate 0.265 11 >0.999 50 xxx xxx xxx 65 3 xxx Fenpropathrin 0.274 11 >0.999 5 17 12.6 12 54 3 17 Tetradifon 0.173 11 >0.999 5 12 11.9 8 55 2 12

Azinphos-methyl 2.071 10 >0.999 5 11 12.5 4 51 3 11 Pyriproxyfen 1.158 16 >0.999 10 xxx 14.1 5 55 2 xxx Spirodiclofen 0.147 21 >0.999 5 13 10.6 10 58 5 13 Pyridaben 4.292 5 >0.999 10 xxx 11.8 11 55 4 xxx Prochloraz 0.562 18 >0.999 10 xxx 12.3 14 51 3 xxx Fenbuconazole 3.670 8 >0.999 5 6 8.9 9 51 3 6 Pyraclostrobin 1.573 9 >0.999 10 xxx 17.5 7 61 3 xxx Azoxystrobin 0.703 8 >0.999 10 xxx 5.7 15 47 8 xxx Famoxadone 0.111 21 >0.999 10 xxx 3.8 12 43 6 xxx Qualitative Specificity and Chromatographic Interferences The MRM chromatograms for all analytes at the LOQ with quantitation (Figure 4A and 4B). For other calibration standard were examined for matrix analytes however, significant matrix interference was interference. For many of the analytes, minimal observed even at higher concentrations (Figures 5A chromatographic interference was observed at the and 5B). lowest calibration level (LOQ), and did not interfere Figure 4A: MRM Chromatograms of 2,4-D Methyl Ester at 5 ppb in Orange Oil Figure 4B: MRM Chromatograms Diazinon at 5 ppb in Orange Oil Figure 5A: MRM Chromatograms Carbofuran at 50 ppb in Orange Oil Figure 5B: MRM Chromatograms Metalaxyl at 50 ppb in Orange Oil

Two compounds, bromopropylate and pyraclostrobin, exhibited unusual chromatographic interferences. The primary (most intense) MRM transitions suggested that background concentrations in the organic orange oil sample exceeded 1000 ng/ml. However, close examination of the results revealed that chromatographic interferences were present only with the primary MRM transition; the secondary and tertiary transitions were not affected. Acceptable quantitative results were obtained when a minor alternate MRM transition was chosen for quantitation. The calibration for bromopropylate using the usual primary transition of 340.9>184.9 is shown in Figure 6A below. The high positive y-intercept in the calibration curve is consistent with background concentration of the analyte at approximately 1000 ppb in the unspiked sample. However, close examination of the data shows that ratio of the less intense 340.9>157.0 transition increases with increasing concentration. This trend is shown graphically in Figure 6B; MRM chromatograms are displayed for each of the calibration standards with the highest concentration at the top. When the 340.9>157.0 transition is used for quantitation, a normal calibration is obtained, as shown in figure 6C. The results indicate interference with the 340.9>184.9 transition from a coeluting compound in the sample matrix. The results point out the need for comparing the ratio of transitions when confirming the qualitative identity of analytes in the MRM mode. Figure 6A: Calibration for Bromopropylate Using the 340.9>184.9 MRM Transition

Increasing concentration MRM chromatograms for bromopropylate calibration standards in orange oil matrix. Intensities of 340.9>157.0 (black trace) and 340.9>182.9 (pink trace) increase relative to 340.9>184.9 (blue trace) as the concentration is increased (concentration increasing from bottom to top). Figure 6B: Variable Transition Ratios vs. Concentration of Bromopropylate Figure 6C: Calibration for Bromopropylate Using the 340.9>157.0 Transition

Sample Results Four real-world orange oil samples were analyzed using the conditions described above. Two of the oils were considered organic, or free of pesticides, and two were not. Four replicates of each sample were analyzed to assess precision of the results. Results are presented in Table 3 below. In Table 3, the reported concentration is the mean result of the four analyses, expressed as concentration in the original sample; the RSD of the four measurements is also included. None of the target pesticides were detected above the quantitation limit in the two organic orange oil samples (Samples 3 and 4), but several target pesticides were detected at various levels in the other two samples. Table 3: Analytical Results for Four Orange Oils Compound Name LOQ (ppb) Sample 1 Non-Organic Conc. %RSD (ppb) Sample 2 Non-Organic Conc. %RSD (ppb) Sample 3 Organic Conc. %RSD (ppb) Sample 4 Organic Conc. %RSD (ppb) 2,4-D methyl ester 5 ND ND ND ND Phendimedipham 100 ND ND ND ND Monocrotophos 10 ND ND ND ND Cadusafos 50 ND ND ND ND Dimethoate 50 ND ND ND ND Carbofuran 50 240 1% 210 1% ND ND Diazinon 5 ND ND ND ND Pyrimethanil 5 ND ND ND ND Parathion-methyl 50 ND ND ND ND Carbaryl 5 ND 2600 1% ND ND Metalaxyl (Mefenoxam) 50 ND ND ND ND Primiphos-methyl 5 ND ND ND ND Methiocarb 50 ND ND ND ND Malathion 50 120 2% 770 1% ND ND Chlorpyrifos 5 360 1% 1900 2% ND ND Fenthion 5 ND ND ND ND Parathion 5 ND ND ND ND Kelthane (Dicofol) 5 970 1% 55 4% ND ND Triphenylmethane (IS) NA ND ND ND ND Pendimethalin (Penoxaline) 5 ND ND ND ND Phenthoate 5 ND ND ND ND Thiabendazole 5 ND ND ND ND Methidathion 10 4900 1% 280 1% ND ND Napropamide 50 ND ND ND ND Imazalil 5 ND ND ND ND Pymetrozine 5 ND ND ND ND 2,4-D ethylhexyl ester 10 ND ND ND ND Fenthion sulfone 5 ND ND ND ND Ethion 5 ND ND ND ND Triazophos 5 ND ND ND ND Trifloxystrobin 5 170 1% 230 3% ND ND Triphenyl Phosphate NA 500 1% 500 1% 496 1% 497 1%

(Control) Propargite-1 100 ND ND ND ND Pyridaphenthion 5 ND ND ND ND Acetamiprid 10 ND ND ND ND Imidan (Phosmet) 5 370 1% 6100 <1% ND ND Fenoxycarb 10 ND ND ND ND Bromopropylate 50 ND ND ND ND Fenpropathrin 5 77 3% 740 1% ND ND Tetradifon 5 ND ND ND ND Azinphos-methyl 5 ND ND ND ND Pyriproxyfen 10 32 1% ND ND ND Spirodiclofen 5 15 5% 22 6% ND ND Pyridaben 10 ND ND ND ND Prochloraz 10 ND ND ND ND Fenbuconazole 5 ND 190 1% ND ND Pyraclostrobin 10 790 1% 320 2% ND ND Azoxystrobin 10 32 2% 140 2% ND ND Famoxadone 10 20 4% ND ND ND Alternate Approaches for Minimizing Interferences from Complex Matrices As illustrated above, chromatographic interferences from complex matrices can significantly impact data quality, even when the specificity of GC-MS/MS in the MRM mode is employed. Several additional approaches for minimizing matrix interferences can be considered for similar applications: Sample pretreatment ( cleanup ) Selection of alternate MRM transitions Use of an alternate chromatographic mobile phase with the Shimadzu Twin Line MS Kit Sample pretreatment can be effective in removing chromatographic interferences, but it is sometimes not possible or desirable. In the case of citrus oils, the QuEChERS procedure may be possible, but it was not employed for this study. Alternate MRM transitions can be used to mitigate interferences. In the example of bromopropylate described above, three MRM transitions are listed in the Shimadzu GC-MS/MS Pesticide Database. While the 340.9>184.9 transition shows significant matrix interference, the 340.9>157.0 and 340.9>182.9 transitions show minimal interferences. The NIST library mass spectrum of bromopropylate, shown in Figure 7 below, suggests that additional transitions may be available, either by selecting alternate precursor ions (m/z 338.9 or 342.9) or alternate product ions (m/z 155, 104, or 76). Inten.(x10,000) 1.0 Br 341 0.5 183 O O OH 0.0 157 43 76 104 262 50.0 75.0 100.0 125.0 150.0 175.0 200.0 225.0 250.0 275.0 300.0 325.0 m/z Figure 7: NIST Library Mass Spectrum of Bromopropylate Br Alternate chromatographic columns can also be employed to separate chromatographic interferences from the analytes of interest. While changing chromatographic columns can be cumbersome and time-consuming, the Shimadzu Twin Line MS System provides a convenient means for simultaneously maintaining two chromatographic columns connected to the MS. This configuration employs two injection ports with two dissimilar chromatographic columns connected to the mass spectrometer by means of a two-hole ferrule. The two-hole ferrule connection is shown in Figure 8 below.

Figure 8: Tw in Line MS Kit Connection w ith 2-Hole Ferrule Conclusion Detection of pesticides was demonstrated at low ng/ml (ppb) levels in orange oil using a Shimadzu GCMS-TQ8030 GC-MS/MS. Calibration was conducted using the matrix-matched internal standard procedure. Nine calibration standards were prepared and analyzed in diluted organic orange oil over the range of 5-5000 ng/ml (ppb), although some compounds could not be accurately quantitated at the low concentrations due to matrix interference. Precision and accuracy were demonstrated by replicate analyses of matrix spiked aliquots at 5, 10 and 50 ng/ml. Results were evaluated for calibration linearity, analytical precision, sensitivity, and specificity. Chromatographic interferences in the MRM mode were variable, depending on the individual analyte. Quantitation levels (LOQ s) were variable, depending upon the analyte, from 5 to 100 ng/ml. A Shimadzu GCMS-TQ8030 system was shown to be a rapid, sensitive, and selective technique for analysis of various classes of pesticides in orange oil. Operation of the GC/MS/MS in the MRM mode provided accurate, precise results for the sample matrix. Reliable, precise measurements were obtained for 47 pesticides. The Shimadzu GC/MS/MS Pesticide Database simplified development of the MRM method. References 1. Shimadzu GC-MS/MS Pesticide Database (October, 2012). 2. Analysis of Organophosphorus Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS System, Shimadzu Application News No. GCMS-1304 (February, 2013). 3. Analysis of Pesticides in Baby Food Using a GCMS-TQ8030 GC/MS/MS, Part II, Shimadzu Application News No. GCMS-1402 (March 2014). 4. AOAC Official Method 2007.01, Pesticide Residues in Foods by Acetonitrile Extraction and Partitioning with Magnesium Sulfate (2007) First Edition: June 2014 SHIMADZU Corporation www.shimadzu.com/an/ SHIMADZU SCIENTIFIC INSTRUMENTS 7102 Riverwood Drive, Columbia, MD 21046, USA Phone: 800-477-1227/410-381-1227, Fax: 410-381-1222 URL: www.ssi.shimadzu.com For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2014