Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming

Similar documents
Calio-Therm NC Type Series Booklet

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

The FLUX F 430 with mechanical seal

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

Contents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

CMA - B - C - D - CMR

DEBEM IM VERTICAL CENTRIFUGAL PUMPS.

TPH Series 50Hz Multi-stage Centrifugal Pump

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

98 Series Backpressure Regulators and Relief Valves

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

APPLICATION CONSTRUCTION

14:1400 (0206) KRAL Volumeter - OMG

LES. Single-stage end-suction pumps Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Electromagnetic Flowmeter

Series P0 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1934, 1843 Rev. : C, D Rev. Date : 6/01, 10/2015

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

Solenoid valves Type EVUL

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

60 Hz. e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS

UNI EN ISO 9001:2008 UNI EN ISO 14001:2004 BS OHSAS 18001:2007 EC DIRECTIVE 2014/34/EU (ATEX) CERTIFIED MANAGEMENT SYSTEM

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Conductivity sensor for hygienic applications

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Direct-operated 2/2-way solenoid valves Type EV210B

Department of Energy Fundamentals Handbook. THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW, Module 3 Fluid Flow

DBS315 1-phase SIDE CHANNEL BLOWERS

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

ISO-C Series chemical Pump

ED 701 General Industry Pressure Transmitter

IL series. Centrifugal marine IN-LINE pumps

n = Kinematic viscosity (cst) SG = specific gravity or 1 Poise = 100 cp 1 Stoke = 100 cst Q = capacity (m 3 /s) A = tube area (m 2 ) or

Standardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design.

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

ELECTRONIC WET ROTOR CIRCULATORS

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Installation guide 862 MIT / MIR

2.1 T211 PTFE-LINED BUTTERFLY VALVE T 211 TECHNICAL DATA

50 Hz. e-lne Series SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC

Direct-operated 2/2-way compact solenoid valves Type EV210A

Cipriani Harrison Valves Corp.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

FLOW DIVIDERS "XV 3 serie" ENGLISH VERS:

Solenoid valves 2/2-way direct-operated type EV210A

e-lnt Series Lenntech ErP 2009/125/EC 50 Hz Tel Fax

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., June 2003

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3

Fluid Cooling Industrial PF Series

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

K DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS

e-mp Series MPA, MPR, MPD, MPV Lenntech 50 Hz Tel Fax

Single Phase Motors Technical Datasheets

PTFE. Laboratory Products

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

VD1 CLC. Small Valves DIN-range with a higher k v -value

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

2.3 T214 PTFE-LINED BUTTERFLY VALVE T 214 TECHNICAL DATA

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

COLGED. Toptech

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Single Phase Motors Technical Datasheets

CME / CM-GE / DCME IN-LINE CONSTANT PRESSURE PUMPS. TECHNICAL DATA - CME/CM-GE single flanged

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12


1.2 Z 014-A LUG TYPE BUTTERFLY VALVE Z 014-A TECHNICAL DATA

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Magnetic couplings, stirrer drives for Chemical Reactors bmd and cyclone: Absolutely tight, safe and dependable

Pressure transmitters for industrial applications MBS 32 and MBS 33

CHAPTER EIGHT P U M P I N G O F L I Q U I D S

Linear guide drives. Synchronous shafts The use of synchronous shafts enables several linear axes to be operated with one drive.

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

1.2 Z 014-A LUG TYPE BUTTERFLY VALVE Z 014-A TECHNICAL DATA:

Transcription:

Prima range TMP centrifugal Alifter range magnetical driven pumps in thermoplastic materials TMA self-priming

Prima - Alifter In this catalog Argal proposes the range of PRIMA pumps, magnetical driven, inclusive of centrifugal serie named TMP and the self-priming volumetric execution named TMA of the ALIFTER range. Single stage, close-coupled execution, strongly built through an injection-moulding process and ready to fit normalized motors. Argal operates with ISO 1: Quality System certified by SQS-IQNet. ATEX View of TMP and TMA pumps in different materials. TMP PUMPS SERIE The pumps of the TMP serie, magnetically driven, have been developed following the idea of previous AM serie, but trying to give a more concise answer to the actual demands of the market. These pumps are centrifugal, horizontal axis, close-coupled types, the bodies are entirely built with reinforced thermoplastic polymers, and materials for internal components are: ceramic oxides, HD carbon, fluorinated elastomers: which mean any contact of metallic parts with the pumped fluid is avoided. This combination of materials is correctly chosen to obtain the best in the performances and on a small scale: chemical pumps. MAIN FEATURES Versatility and performances. You can practically pump all the chemicals at low and medium temperatures with all the bodies in GFR-PP (glass fibre reinforced polypropylene) or CFF-E-CTFE (Etylene-ChloroTrifluoroEtylene carbon fibre filled). Strong magnetic coupling made up of rare-earth materials (Neodimium Iron Boron) and N (standard), P (powered) or S (strong-powered) versions allow to pump, also at maximum flow, liquids with 1. - 1. - 1. specific gravity respectively. R-N-X: three internal configuration of constructive materials for many applications: from clean water to waste and slightly abrasive liquids, strong alkali or salts such as sodium hypochlorite, and acids such as chromic, nitric, sulphuric, etc.. Hermetic pump The outlet magnet assembly driven by the motor shaft, produces a magnetic torque dragging up in rotation the inside magnet assembly on which the impeller is over moulded. The rear casing, having appropriate shape and joined to the volute casing, divides the two magnetic units, making an hermetic case all around the impeller. Safety and life The drive magnetic system finally excludes any type of rotating seal. The only need of the seal is guaranteed thanks to an O-ring static gasket, in the connection between volute casing and rear casing. Special solutions and employed materials occasionally allow dry running operation (starting from 1 min. up to many hours in function of working conditions), avoiding any damages inside the TMP pumps. These solutions require an internal structure R. is member of

TMP 1 U.S. gpm 1 1 1 General Performance Curve r.p.m. - Hz 1 General Performance Curve r.p.m. - Hz 1 1 Head (m) Head (ft)..11...1..11 1. m /h 1 1 1 1 1 1 Capacity 1 1 1 1 L/1 NOTES: All curves are referred to: water at C - viscosity 1 E - specific gravity 1 kg/dm pt THE MATERIALS table 1 VERSION REINFORCED POLYMERS MIN. TEMP. MAX TEMP. ENVIRONMENT TEMP. WR GFR/PP - C ( F) C (1 F) C (1 1 F) GF GX* CFF/E-CTFE - C (- F) 1 C (1 F) - C (- 1 F) Note: Maximum inlet pressure: 1, bar - (*) Compliant to ATEX //EC regulations THE CONSTRUCTIONS table VERSION WR GF GX* R1 X1 N1 R X N R N Volute casing Rear casing Centrifugal impeller Guide bushing CARB.HD GFR-PP SiC GFR-PTFE CARB.HD SiC CFF-E-CTFE GFR-PTFE CARB.HD GFR-PTFE Shaft Thrust bush CER SiC OR gasket FKM (1) FKM (1) () Screws Stainless steel Upon request:(1)epdm and () FFKM - * Compliant to ATEX //EC regulations TMP - SECTION VIEW 1 - Volute casing 1 - - - - Centrifugal impeller (covered type) Centrifugal impeller (magnetic part) Guide bushings Rear casing - - - OR gasket Drive magnet assembly Bracket

TMA The self priming, magnetic drive pumps of the TMA serie are volumetric, can deliver the flow in both directions reversing the direction of rotation of the motor and are adequate to speedily prime chemical liquids with high specific gravity and/or high vapour tension. OPERTAING PRINCIPLES OF THE PUMP MAIN FEATURES Start-up with empty pipes Fast priming-phase Maximum Lift = - m Reversible (inlet-outlet reversal) Suitable for specific weight up to kg/dm Suitable for vapour pressure up to 1 m (HO @ C) Minimum NPSHa (available on the plant) = m (abs) Impeller replaceable apart from magnets IEC or NEMA standard motors can be installed Stopping phase: a small quantity of liquid is trapped into the pump to enable the next starting. Priming phase: the impeller gives a specific circulation of air-liquid mixture moving air from the suction pipe to the discharge side in the atmosphere. Pumping phase: after the air is totally removed from the suction side, the pipe is flooded by the liquid and the pumping phase can start. 1 1 1 1 1,,,,, 1.1 Performance Curve r.p.m. - Hz,,,, 1 1, 1, 1, 1,,,,,,, 1 1, 1, 1, 1,,,,,, 1 1 1.1 Performance Curve r.p.m. - Hz,,,, 1 1, 1, 1, 1,,,,,,,,,,,, 1 1, 1, 1, 1,,,,,, PRIMING-TIME (sec) 1 1 PRIMING TIME WITH WATER -1-1, - -, - -, - -, - LIFT (m) THE MATERIALS table VERSION REINFORCED POLYMERS MIN. TEMP. MAX TEMP. ENVIRONMENT TEMP. WR GFR/PP - C ( F) C (1 F) C (1 1 F) GF CFF/E-CTFE - C (- F) C (1 F) - C (- 1 F) Note: Maximum inlet pressure: 1, bar THE CONSTRUCTIONS table VERSION WR GF R1 X1 N1 R X N Volute casing Rear casing Centrifugal impeller Guide bushing CARB.HD GFR-PP SiC GFR-PTFE CARB.HD CFF-E-CTFE SiC GFR-PTFE Shaft Thrust bush CER SiC OR gasket FKM (1) FKM (1) () Screws Stainless steel Upon request:(1)epdm and () FFKM TMA - SECTION VIEW 1 - Connections casing - - Impeller Magnetic core 1 - - Front volute casing Rear casing - - OR gasket Drive magnet assembly - Bracket - Filling plug

TMP - TMA PUMP SPECIFICATIONS table Connections TMP TMA Thread....11...1.11 1.1 1.1 DeM BSP-NPT / m 1 m 1 1/ m 1 1/ m / f DeA BSP-NPT / f 1 m 1 1/ m 1 1/ m / f Flange DnM-DnA ISO DnM-DnA ANSI 1 1 1/ 1 1/ 1 MOTOR SPECIFICATIONS Hz models table....1 1.1 N P S N P S N P S N P S N P S Power (IEC) Hz kw.1.......... 1.1.. 1.1 Motor size IEC A B 1A B 1A 1B 1A 1B A 1B A B 1B A B Phases N. phase - 1phase Std. voltage (IEC) V ± % Hz - ± % Hz Motor protection IP MOTOR SPECIFICATIONS Hz models table..11..11 1.1 N P S N P S N P S N P S N P S Power (IEC) Hz kw........ 1.1. 1.1. 1.1 Motor size IEC B 1A 1B 1A 1B A 1B A B A B A B Phases N. phase - 1phase Std. voltage (IEC) V ± 1% Hz - ± 1% Hz Motor protection IP WEIGHT -Hz models table Pump weight (without motor) Motor weight WR GF GX Version IEC phase - 1phase Frame A B 1A 1B A B 1, - (,*) - (*) Kg,,,, 1, 1 * Weight referred to TMA TMP pumps in WR execution TMA pump and trolley.1 -.11. -.. -.11. -. PUMP IDENTIFICATION LABEL table TMP. WR V R1 B E N Prima - Alifter range chosen model EXEC. N=normal P=powered S=strong-pow. see materials and construction V = FKM E = EPDM K = FFKM see materials and construction B = thr. BSP N = thr. NPT Z = flanged ISO-ANSI-JIS ISO-ANSI-JIS E = IEC U = NEMA N = Std. S = Spec. V. E = Ex-proof O = No motor = phase 1 = 1 phase SERIE MODEL EXECUTION VERSION O-ring INTERNAL CONNECTION MATERIALS STRUCTURE STANDARD MOTOR DATA MOTOR MOTOR PHASES TMP.. N WR V N1 B E N TMA...1.11..11 P GF E R1 X1 N N U S 1 S GX 1.1 1.1 only TMP K R X Z E O

TMP. r.p.m. - Hz,,, 1, 1 1,,,,,,,1,1,1, 1 1,,,,.1 1 1 r.p.m. - Hz 1,,, 1 1,,,,, 1 1. 11 1 r.p.m. - Hz,,, 1 1,,,,1,1 1. 1 1 r.p.m. - Hz 1,,, 1,,,,1,1 1. 1 r.p.m. - Hz 1 1 1,,,,, 1 1.11 1 r.p.m. - Hz 1 1 1 1,,,,, 1,,,,,,. 1 1 r.p.m. - Hz 1 1,,, 1 1,,,,,, 1 1.11 1 r.p.m. - Hz 1 1 1 1 1 1,,,,, 1 1,,, ATEX TMP. model GX execution with ff flange Labels in this catalog GFR/PP Glass fibre reinforced Polypropylene (%) EPDM Etylene-Propylene rubber CFF/E-CTFE Etylene-Chloro Trifluoro Ethylene carbon fibre filled (%) BSP - m BSP parallel threaded male connect. (according to ISO /1) CARB. H.D. Carbon hight density NPT - m Threaded male NPT connections SiC Silicon Carbide ND Nominal diameter CER Alumina ceramic at,% ISO Ref. Flange ISO - NP1 GFR/PTFE Glass fibre reinforced PTFE ANSI Ref. Flange ANSI B 1. Flat Face FKM Fluorine elastomer IEC According to E.C. motors FFKM Perfluorelastomer NEMA Accordind to U.S. motors

TMP - TMA TMP serie d x z KM DnM L a1 a1.1 a1 Q DeM, d x z h h.1 KA HD h1 DeA DnA, n1 s m1 r r1 rb B h L s B L1 DIMENSIONS WITH IEC MOTORS table TMP Hz TMP Hz TMA HZ TMA HZ....1..11..11 1.1 1.1 N P S N P S N P S N P S N P S N P S N P S N P S N P S N P S a1,, a1.1 Q 11 11 h 1 1 1 1 1 1 1 1 1 1 h.1 1 1 1 1 1 1 1 1 L(*) h1 1 1 1 1 1 1 1 1 1 1 1 1 1 HD(*) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 m1 1 1 1 1 1 1 1 1 1 1 1 1 n1 1 1 11 1 11 11 11 11 1 11 1 1 1 11 11 11 11 1 11 1 1 1 1 11 1 1 11 1 1 r1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 r 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 rb 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 s 1 1 1 1 1 1 1 1 1 1 1 1 B B L1 L 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 h s 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 dxz K TMA serie DN DN Q DN L r1 a1 / F h1 h1 HD h h n1 s1 m1 r rb B h L s B L1

Member of AIB associazione industriale Bresciana Via Labirinto, 1-1 BRESCIA - ITALY Tel. +..11 - Fax +.. - Export dpt. Tel. +.. Web: www.argal.it - E-mail: export@argal.it It is the policy of ARGAL to always improve its products and the right is reserved to alter specifications at any time without prior notice. No part of this publication may be reproduced in any form or any means.