Chemiluminescence A Toast to Chemistry Chemiluminescence

Similar documents
Hydrolysis of Salts Weak Acids and Bases

Iodine Clock Challenge Rate Laws

Solubility Patterns SCIENTIFIC. Double-replacement reactions. Introduction. Concepts. Materials. Safety Precautions. Procedure

Use this dramatic iodine clock reaction to demonstrate the effect of concentration, temperature, and a catalyst on the rate of a chemical reaction.

Upset Tummy? MOM to the Rescue! LeChâtelier s Principle

What if It s an Acid and a Base? Food Additives

Mole Lab Introduction to The Mole Concept

The Forensic Examiner

Experiment 8 - Chemical Changes

Building Models of Elements, Compounds and Mixtures Classifying Matter and Physical versus Chemical Changes

Day in the Dark Demonstrations with Jamie Benigna

Hands-On Science. Light & Color. W. Michael Margolin Illustrated by Lloyd Birmingham

The Law of Definite Proportions

Identification of an Unknown Compound through Mass Correlations

Separation and Qualitative Determination of Cations

Part II. Cu(OH)2(s) CuO(s)

Equilibrium Demonstrations The Good, the Bad, and the Ugly Models and Simulations

Experiment 8 - Double Displacement Reactions

EXPERIMENT 17. Oxidation-Reduction Reactions INTRODUCTION

Periodicity of Properties of Oxides

Classifying Chemical Reactions: Lab Directions

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

Construct a visual diagram that can help explain and model the appropriate filling order for electrons in electronic configurations.

Thermodynamics Enthalpy of Reaction and Hess s Law

Titration with an Acid and a Base

To determine relative oxidizing and reducing strengths of a series of metals and ions.

In this activity, you will observe and predict products for some simple

Relative Solubility of Transition Elements

Synthesis of Benzoic Acid

Pre-Lab Read the entire laboratory assignment. Answer all pre-lab questions before beginning the lab.

More Chemical Changes

7-A. Inquiry INVESTIGATION. 322 MHR Unit 3 Quantities in Chemical Reactions. Skill Check. Safety Precautions

Chemistry 1B Experiment 17 89

Classifying Chemical Reactions

Procedures for Preparing Reagents and Media used in Firearm and Tool Mark Examinations

EXPERIMENT 6 Empirical Formula of a Compound

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

Electrolysis SCIENCE TOPICS PROCESS SKILLS VOCABULARY

Acid-Base Titration. M M V a

Core practical 6: Investigating chlorination of 2-methylpropan-2-ol

Microscale Acid-Base Titration

Percentage of Acetic Acid in Vinegar

Physical and ChemJcaJ Change

Classi fying Chemical Reactions

INTRODUCTION TO ACIDS, BASES AND TITRATION

What Do You Think? Investigate GOALS

Microscale Acid-Base Titration

Chemical Reactions: The Copper Cycle

Classifying Chemical Reactions Analyzing and Predicting Products

HEATS OF REACTION EXPERIMENT

EXPERIMENT 6. Physical and Chemical Changes Part 2 INTRODUCTION

Chemistry CP Lab: Additivity of Heats of Reaction (Hess Law)

Kinetics of Crystal Violet Fading AP* Chemistry Big Idea 4, Investigation 11 An Advanced Inquiry Lab

Designing a Hand Warmer AP* Chemistry Big Idea 5, Investigation 12 An Advanced Inquiry Lab

Acidity of Beverages Lab

Acid-Base Titration. Sample

Standardization of a Primary Standard & Determination of Concentration by Acid-Base Titration

4.5 The iodoform test. Task. How can methanol be distinguished from ethanol? (2) Science - Chemistry - Organic Chemistry - 4 Alcohols (P )

Name Date Class. Chapter 19 Acids, Bases, and Salts EXPERIMENT. ESTIMATION OF ph PURPOSE BACKGROUND MATERIALS (PER PAIR)

Characteristics of Chemical Change

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

TYPES OF CHEMICAL REACTIONS

AP Chemistry Unit 2 Test (Chapters 3 and 4)

Forensics Lab Flame Tests

Properties of Acids and Bases

EXPERIMENT 20. Solutions INTRODUCTION

Experiment 17. Synthesis of Aspirin. Introduction

Name Period Date. Lab 9: Analysis of Commercial Bleach

EXPERIMENT THREE THE CANNIZARO REACTION: THE DISPROPORTIONATION OF BENZALDEHYDE

Core practical 5: Investigate the oxidation of ethanol

Amend Lab 15 Observing Equilibrium

Mixtures of Acids and Bases

Stresses Applied to Chemical Equilibrium

Acids, Bases, Salts, and Buffers

CIE Chemistry A-Level Practicals for Papers 3 and 5

Measuring Enthalpy Changes

To explore solubilities and reactivities of different metal ions. To identify ions present in unknown solutions using separation methods.

Na Na + +e - Cl+e - Cl -

Classification of Mystery Substances

o Test tube In this experiment, you ll be observing the signs of chemical reactions. These include the following:

Lab #14: Qualitative Analysis of Cations and Anions

Section I: Synthesis reactions Synthesis reactions occur when two or more substances come together to form a single new substance.

26. The preparation and purification of N-phenylethanamide Student Sheet

Acids and Bases. How does ph affect biological solutions? Introduction. Prelab Preparation Review Section 2.3 on acids and bases in your textbook.

Acid Base Titration Experiment ACID - BASE TITRATION LAB

Activity 2 Elements and Their Properties

Reaction Stoichiometry

2. Synthesis of Aspirin

AP Chemistry Lab #5- Synthesis and Analysis of Alum (Big Idea 1 & 2)

Kinetics of Crystal Violet Fading AP Chemistry Big Idea 4, Investigation 11 An Advanced Inquiry Lab (adapted by Flinn Scientific, Inc.

The ABCs of Chemistry

Recovery of Copper Renee Y. Becker Manatee Community College

Completion Match each each piece of equipment with its description. Please only put one number in the blank.

GRIGNARD REACTION Synthesis of Benzoic Acid

Rate of Reaction. Introduction

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

Limiting Reactants An analogy and learning cycle approach

HYSICAL AND CHEMICAL PROPERTIES AND PHYSIC AND CHEMICAL CHANGES

Chemical Bonds. MATERIALS 24-well microplate calcium chloride candle citric acid conductivity tester ethanol gloves iron ring lab apron

Preparation of an Ester Acetylsalicylic Acid (Aspirin)

Transcription:

Chemiluminescence A Toast to Chemistry Chemiluminescence SCIENTIFIC Introduction Chemiluminescence demonstrations are popular with students and teachers alike. This activity demonstrates basic chemiluminescence using luminol. Concepts Chemiluminescence Oxidation reduction Catalyst Materials (for one demonstration) Hydrogen peroxide, H 2 O 2, 3%, 15 ml Beakers, 1-L, 2 Luminol, 0.1 g Erlenmeyer flask, 2-L Potassium ferricyanide, K 3 Fe(CN) 6, 0.7 g Sodium hydroxide solution, NaOH, 5%, 50 ml Water, distilled or deionized, 2000 ml Funnel, large Graduated cylinder, 50-mL Ring stand and ring Safety Precautions Please review current Material Safety Data Sheets for additional safety, handling, and disposal information. Hydrogen peroxide is an oxidizer and skin and eye irritant. Sodium hydroxide solution is corrosive, very dangerous to eyes, and skin burns are possible. Much heat is evolved when sodium hydroxide is added to water. If heated to decomposition or in contact with concentrated acids, potassium ferricyanide may evolve poisonous hydrogen cyanide fumes. Wear chemical splash goggles, chemical-resistant gloves, and a chemical-resistant apron. Preparation 1. Prepare Solution A by adding 0.1 g of luminol and 50 ml of 5% sodium hydroxide solution to approximately 800 ml of distilled or deionized (DI) water. Stir to dissolve the luminol. Once dissolved, dilute this solution to a final volume of 1000 ml with DI water. 2. Prepare Solution B by adding 0.7 g of potassium ferricyanide and 15 ml of 3% hydrogen peroxide to approximately 800 ml of DI water. Stir to dissolve the potassium ferricyanide. Once dissolved, dilute this solution to a final volume of 1000 ml with DI water. 3. Set up the demonstration container(s) as desired. A sample flask and funnel is shown in Figure 1. 4. See Tips section for other set-up ideas. Procedure 1. Turn down the lights. The room should be as dark as possible. 2. Pour Solution A and Solution B into the large funnel or desired container(s) simultaneously. As the two solutions mix, chemiluminescence begins. 3. As the reaction progresses, it can be enhanced by adding small amounts of potassium ferricyanide and 5 10 ml of 5% sodium hydroxide solution into the flask. Ring stand Figure 1. Large funnel 2-L Erlenmeyer flask 2016 Flinn Scientific, Inc. All Rights Reserved. Publication No. 91331 1 061616

Disposal Please consult your current Flinn Scientific Catalog/Reference Manual for general guidelines and specific procedures governing the disposal of laboratory waste. The resulting solutions may be disposed of according to Flinn Suggested Disposal Method #26b. Tips The Cool Light Demonstration Kit (Catalog No. AP8627) is available from Flinn Scientific and contains enough chemicals to perform the demonstration seven times: 1 g of luminol, 5 g of potassium ferricyanide, 500 ml of 5% sodium hydroxide, and 500 ml of 3% hydrogen peroxide. This demonstration is especially appealing if it is set up so the students can see the mixture moving through glasses, such as used by Kathleen Dombrink in the video, or by spiraling clear plastic tubing. To use spiraling clear tubing, simply fol low the directions for setup at the end of these instructions. This type of apparatus gives a large surface area for light to be emitted as well as providing a flowing effect along with the luminescence increasing the overall visual impact. Another means of displaying luminol s luminescence is to take the two solutions (A and B above), place them in spray bottles, and spray them at each other creating a luminescent cloud. The key to this procedure is to get the solutions into as fine a mist as possible. Caution: Do not spray the solutions toward anyone or in a manner in which they can be easily inhaled. Use only distilled or deionized water when preparing the solutions. Hard water and softened water contain high con centrations of ions (such as chloride ions) that may interfere with the excited state of the luminol and prevent chemiluminescence. Discussion Over the past several centuries there has been great expansion in the knowledge about materials, organic and inorganic, that produce light (luminescence). There are at least six different classifications of light-producing systems that have been observed. One of these is known as chemiluminescence; light produced through a chemical reaction, whether in a gas or in solution. The energy for light emission comes from a chemical reaction, usually involving considerable change in the composition of the chemiluminescent material. The appearance of colors when different metal salts are placed in the flame of a Bunsen burner are examples of a variation of chemiluminescence known as pyroluminescence. One of the long-standing classic models of a chemiluminescent reaction is the glow of solid phosphorus in air. This is an oxidation reaction in which light is produced and some heat. Out of a wide variety of cool light demonstrations, where little or no heat is produced, the use of luminol (3-aminophthalhydrazide) has been one of the most popular. Luminol was discovered to be luminescent by Albrecht in 1928. Since that time numerous procedures have been developed O O that produce light using luminol. Experimentation has NH oxidation O + 2OH demonstrated that for luminol to luminesce, an oxidizing NH O + 2H 2 O + N 2 agent, an alkaline ph, and some type of catalyst (such as copper or iron compounds) are required. This procedure NH 2 O NH 2 O gives just that condition. Sodium hydroxide acts as a base and converts luminol into a dianion that is oxidized by I II hydrogen peroxide to an aminophthalate ion. The aminophthalate is found in an excited state that will decay to a lower energy state through chemiluminescence and one of the products is the emission of light. This light has a wavelength of 425 nm, which is in the blue zone of the visible spectrum. The chemiluminescence demonstration has value not only for the obvious reason of demonstrating chemiluminescence, but it can also be used to show the effects of a catalyst, the effect of ph on a reaction, the effect of temperature on a reaction, and how reaction rates are affected by concentration. Connecting to the National Standards This laboratory activity relates to the following National Science Education Standards (1996): Unifying Concepts and Processes: Grades K 12 Evidence, models, and explanation 2 2016 Flinn Scientific, Inc. All Rights Reserved.

Content Standards: Grades 5 8 Content Standard B: Physical Science, properties and changes of properties in matter, transfer of energy Content Standards: Grades 9 12 Content Standard B: Physical Science, structure and properties of matter, chemical reactions, interactions of energy and matter Answers to Worksheet Questions 1. Describe what happened in this demonstration. Two solutions were poured through a large funnel simultaneously. The mixture of the two solutions began to glow. 2. Oxidation is necessary for luminol to luminesce. The chemicals used in this experiment were 5% sodium hydroxide, 3% hydrogen peroxide, and potassium ferricyanide. Which of these do you think served as the oxidizing agent? Hydrogen peroxide was the oxidizing agent in this demonstration. 3. In chemiluminescence, a molecule in an excited state (i.e., electrons are at a high energy level) is produced. The electrons in the molecule then must return to their stable state (i.e., lower energy level. Explain how this is linked to the production of light. When an electron drops to a lower energy level, energy must be released. This energy is released in the form of light. 4. Define chemiluminescence. Give an example of chemiluminescence found in nature. Chemiluminescence is a process in which light is produced through a chemical reactions. An example of this that is found in nature is the firefly. Acknowledgment Special thanks to Paul Smith of Purdue University, West Lafayette, IN. References Harvey, E. N., A History of Lumines cence. The American Philosophical Society: Philadelphia, PA, 1957; p 5. Huntress, E. H.; Stanley, L. N.; Parker, A. S., J. Chem. Educ., 1934, 11, 145. Shakhashiri, B. Z. Chemical Demon stra tions: A Handbook for Teachers of Chemistry, Vol. 1; University of Wisconsin: Madison, 1985; p 189. Flinn Scientific Teaching Chemistry elearning Video Series A video of the Chemiluminescence A Toast to Chemistry activity, presented by Kathleen Dombrink, is available in Chemiluminescence, part of the Flinn Scientific Teaching Chemistry elearning Video Series. Materials for Chemiluminescence A Toast to Chemistry are available from Flinn Scientific, Inc. Materials required to perform this activity are available in the Cool Light Chemical Demonstration Kit available from Flinn Scientific. Materials may also be purchased separately. Catalog No. AP8627 L0078 S0074 P0050 H0009 Description Cool Light Chemical Demonstration Kit Luminol, 5 g Sodium Hydroxide, 100 g Potassium Ferricyanide, 100 g Hydrogen Peroxide, 3%, 500 ml Consult your Flinn Scientific Catalog/Reference Manual for current prices. 3 2016 Flinn Scientific, Inc. All Rights Reserved.

Chemiluminescence A Toast to Chemistry Worksheet Discussion Questions 1. Describe what happened in this demonstration. 2. Oxidation is necessary for luminol to luminesce. The chemicals used in this experiment were 5% sodium hydroxide, 3% hydrogen peroxide, and potassium ferricyanide. Which of these do you think served as the oxidizing agent? 3. In chemiluminescence, a molecule in an excited state (i.e. electrons are at a high energy level) is produced. The electrons in the molecule then must return to their stable state (i.e. lower energy level. Explain how this is linked to the production of light. 4. Define chemiluminescence. Give an example of chemiluminescence found in nature. 4 2016 Flinn Scientific, Inc. All Rights Reserved.

HOW TO... Materials Make Your Own Cool Light Spiral Apparatus Glass Funnel (large enough to sit in the opening of the Plexiglas tube) Clear plastic (Tygon ) tubing Long Plexiglas tube 2 Glass elbows or glass tubing with bends Collecting vessel Electric drill 1. Attach to the funnel stem a small piece of plastic tubing, a glass elbow and the long plastic tubing you will use for the spiral. Place this setup down into the Plexiglas tube. 2. Drill a hole in the Plexiglas tube just below the height of the glass elbow connected to the funnel stem. Thread the long plastic tubing through this hole from the inside out. 3. Spiral the tubing around the Plexiglas tube. 4. Drill a hole in the Plexiglas tube 1 above the height of your collecting vessel. Feed the spiraled tubing through the hole and attach it to a glass elbow and a small piece of plastic tubing. If the tubing does not stay tightly spiraled, a small amount of quick-drying glue can be used to keep it in place. 5. Select a collecting vessel (e.g. battery jar, beaker) large enough to contain all the chemiluminescent liquid used in the demonstration. (In this case, the vessel must be larger than two liters.) The Plexiglas tube must fit over the collecting vessel. Insert the plastic tubing into your collecting vessel. 6. If your spiral is tall, we urge you to build some sort of support stand or attach it to a ring stand for stability. You don t want the apparatus to tip over. 7. Once the spiral is set up, dim the lights and pour your favorite chemiluminescent solution through it. Your students will love it! Tygon Tube Tygon Tube Collecting Flask 6 1/3 ft. 147 mm 6 in. 2 in. Glass Elbow Tygon Tubing Glass Elbow The Cool Light spiral can easily be scaled down to suit readily available equipment 5 2016 Flinn Scientific, Inc. All Rights Reserved.

Chemiluminescence A Toast to Chemistry continued 6 2016 Flinn Scientific, Inc. All Rights Reserved.