OVERVIEW OF THE TRITIUM-IN-AIR MONITORING SYSTEM OF CERNAVODA NPP U1 ROMANIA MODERNIZATION AND IMPROVEMENT PROJECT

Similar documents
ESTIMATION OF RADIONUCLIDE RELEASES IN ATMOSPHERE FROM CERNAVODA NPP BASED ON CONTINUOUS GASEOUS EFFLUENT MONITORING

12 Moderator And Moderator System

SOUTHERN NUCLEAR COMPANY VOGTLE ELECTRIC GENERATING PLANT UNITS 1 AND 2 NRC DOCKET NOS AND

RADIATION PROTECTION

IEC Tritium Standard

Airborne Tritium Mitigation Successes at Darlington. Tom Wong. RP Section Manager Darlington Nuclear

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY

A Method of Quantifying Noble Gas Releases Douglas Wahl Exelon Limerick Generating Station

Estimation of accidental environmental release based on containment measurements

Noble Gas Control Room Accident Filtration System for Severe Accident Conditions (N-CRAFT)

TOTAL 6 STACK MONITORS ~ GAS, PARTICULATE GROSS BETA-GAMMA ~ IODINE ~ TRITIUM ~ C-14

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS

Course Reactor & Auxiliaries - Module 1 - Moderator Heavy Watec. Module 1 MODERATOR ..." Y "... I

AP1000 European 15. Accident Analyses Design Control Document

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

11. Radioactive Waste Management AP1000 Design Control Document

Tritium Fuel Cycle Safety

IL H DESIGN FOR KRYPTON-85 ENRICHMENT BY THERMAL DIFFUSION

WHAT IS IONIZING RADIATION

1. What would be the dose rate of two curies of 60Co with combined energies of 2500 kev given off 100% of the time?

Residual activity (contamination) Radiation exposure levels

Tritium Safety of Russian Test Blanket Module

A Brief Overview of Radiation and Analytical Water Testing for Radiological Contaminants.

Acoustics and Ionising Radiation Formulation and Strategy. 13 November 2008 Alan DuSautoy

METHOD TEST METHODS FOR MEASURING RADIONUCLIDE EMISSION FROM STATIONARY SOURCES

Successful Development of a New Catalyst for Efficiently Collecting Tritium in Nuclear Fusion Reactors

Radioactivity: the process by which atoms emit energy in the form of electromagnetic waves, charged particles, or uncharged particles.

AP1000 European 11. Radioactive Waste Management Design Control Document

Industrial Hygiene: Assessment and Control of the Occupational Environment

turbine (a) (i) Which part of the power station provides thermal (heat) energy from a chain reaction?

Jason T. Harris, Ph.D. Department of Nuclear Engineering and Health Physics

PWR Airborne Tritium & Review of RG 1.21 data. S. Sandike June 2014 EnvoNuTek, llc

Nuclear power plants can generate large amounts of electricity.

Mercury Stack Monitor SM-4

Cryogenic Target Handling System Operations Manual Volume IV CTHS Description Chapter 5: Tritium Fill Station (TFS)

Department of Energy Office of Worker Protection Programs and Hazards Management Radiological Control Technical Position RCTP 99-02

Science 10: Radioactivity! Comparing Fission and Fusion Notes (Ch 11)

New Test Results For Physical Separation Of Tritium From Noble Gases And It s Implications For Sensitivity And Accuracy In Air And Stack Monitoring

UNIT 10 RADIOACTIVITY AND NUCLEAR CHEMISTRY

AIR SAMPLING PROGRAM/METHODS RCT STUDY GUIDE State the primary objectives of an air monitoring program.

Nuclear Chemistry. Nuclear Terminology

Chem 481 Lecture Material 4/22/09

WM 05 Conference, February 27 March 3, 2005, Tucson, AZ DEVELOPMENT OF A STORAGE VESSEL AND SHIPPING PACKAGE FOR TRITIUM

Compact Orifice FlowMeter

DOE 2.06 Air Sampling Program/Methods Study Guide 00ICP319 Rev.00 Page 1 of 21

Chemistry 500: Chemistry in Modern Living. Topic 5: The Fires of Nuclear Fission. Atomic Structure, Nuclear Fission and Fusion, and Nuclear.

UNIT 10 RADIOACTIVITY AND NUCLEAR CHEMISTRY

The sources include Am-241 which emits alpha radiation, Sr-90 which emits beta radiation and Co-60 which emits gamma radiation.

GCE AS and A Level. Physics A. AS exams 2009 onwards A2 exams 2010 onwards. Unit 5: Approved specimen question paper. Version 1.3

Nuclear fission and fusion are processes that involve extremely large amounts of energy.

4.4.1 Atoms and isotopes The structure of an atom Mass number, atomic number and isotopes. Content

FEATURES: CAM-TC CAM-TCI

Name of research institute or organization: Bundesamt für Gesundheit, Sektion Umweltradioaktivität, Bern

Background Tritium in Environmental Water Samples. Paul Snead NCHPS Fall Meeting November 2, 2006

Gabriele Hampel 1, Uwe Klaus 2

QuantumMCA QuantumNaI QuantumGe QuantumGold

Advanced Tritium Recovery System

Mohamed BEN ABDALLAH

SLAC Radioanalysis Laboratory

PI Chemistry - PI 24 ENVIRONMENTAL MONITORING - RADIOLOGICAL EMISSIONS

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

Tritium Inventories and Tritium Safety Design Principles for the Fuel cycle of ITER

Applied Nuclear Science Educational, Training & Simulation Systems

UALR Radiation Safety Office

Radioactive effluent releases from Rokkasho Reprocessing Plant (1) - Gaseous effluent -

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

The basic structure of an atom is a positively charged nucleus composed of both protons and neutrons surrounded by negatively charged electrons.

Characterization of Large Structures & Components

Experience with different methods for on- and off-line detection of small releases of fission products from fuel elements at the HOR

Differential Mobility Particle Sizer (Aerosol measurements)

Detection of Xe135 at Nuclear Reactor of Unit 2, Fukushima Daiichi Nuclear Power Station. November 4, 2011 Tokyo Electric Power Company

Portable Radiation Survey Instruments

The Vacuum Case for KATRIN

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

SETTING OF THE APPARATUS FOR IRRADIATION OF SAMPLES WITH FAST NEUTRONS IN THE EXPOSURE ROOM OF TRIGA MARK II REACTOR IN LJUBLJANA

P4 Quick Revision Questions

RADIONUCLIDE MEASURMENTS FOR NUCLEAR EXPLOSION MONITORING

COLUMBIA UNIVERSITY PERMIT APPLICATION FOR NON-HUMAN USE OF RADIOACTIVE MATERIALS

Wallace Hall Academy Physics Department. Radiation. Pupil Notes Name:

Accelerator Facility Accident Report

HALF LIFE. NJSP HMRU June 10, Student Handout CBRNE AWARENESS Module 4 1. Objectives. Student will

Parts Manual R410A Models

Nuclear forces and Radioactivity. Two forces are at work inside the nucleus of an atom

Storing, using and disposing of unsealed radioactive substances in a Type C Laboratory: Extract of regulatory requirements

STATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION. Price: $5.00. Revised March 31, 1997

P7 Radioactivity. Student Book answers. P7.1 Atoms and radiation. Question Answer Marks Guidance

Isotopes: atoms with the same Z but different A s (number of neutrons varies)

Radiation Awareness Training. Stephen Price Office of Research Safety

SECTION 8 Part I Typical Questions

Protection against environmental ionizing (mainly gamma)

Unit 6 Nuclear Radiation Parent Guide. What is radioactivity and why are things radioactive?

THE IMPLEMENTATION OF RADIOLOGICAL CHRACTERIZATION FOR REACTOR DECOMMISSIONING. China Nuclear Power Engineering Co. Ltd, Beijing , China

External Dosimetry at NPPs; NVLAP, Noble Gas, and TEDE

3. Chemical Hygiene Plan: Laboratory Standard Operating Procedures. A. Laboratory Specific Information and Signatures

1. Which is the most commonly used molten metal for cooling of nuclear reactors? A. Zinc B. Sodium C. Calcium D. Mercury

Department of Energy OffIce of Worker Protection Programs and Hazards Management Radiological Control Technical Position RCTP

A Fast Responding Continuous Tritium-in-Air Monitor with Multi Stream Sampling for Area Monitoring

Radiation Safety Training for General Radiation Workers

Nuclear Energy. Nuclear Structure and Radioactivity

12/18/2016. Radioanalysis Laboratory Capabilities and Issues. Eleventh Annual Radiation Measurement Cross Calibration Workshop RMCC XI

Transcription:

International Conference Nuclear Energy in Central Europe 2001 Hoteli Bernardin, Portorož, Slovenia, September 10-13, 2001 www: http://www.drustvo-js.si/port2001/ e-mail: PORT2001@ijs.si tel.:+ 386 1 588 5247, + 386 1 588 5311 fax:+ 386 1 561 2335 Nuclear Society of Slovenia, PORT2001, Jamova 39, SI-1000 Ljubljana, Slovenia OVERVIEW OF THE TRITIUM-IN-AIR MONITORING SYSTEM OF CERNAVODA NPP U1 ROMANIA MODERNIZATION AND IMPROVEMENT PROJECT S. Murgoci, I. Popescu, R. Ibadula, Health Physics Department, Cernavoda NPP 1 Medgidiei Str., 8625, Cernavoda, jud. Constanta, Romania smurgoci@cne.ro, ipopescu@cne.ro, ribadula@cne.ro ABSTRACT The Tritium-in-Air Monitoring System used in Cernavoda NPP U1 is a Scintrex Model 292 and is a multi-room monitoring station for measuring tritium activity in air, particularly tritiated water vapor, ideal for installations in: - Nuclear Power Stations - Tritium Extraction Plants - Fusion Facilities - Other Industrial Tritium Applications The Tritium-in-Air Monitoring System (Scintrex Model 292) has two major limitations: - the presetted setpoint is not for the tritium level of activity, is for a global activity including noble gas contribution; - the presetted setpoint should be changed for each particular room, which means a major delay in the location of D 2 O leak sources. Both limitations can be solved by using a Tritium Monitoring Network consisting of a number of tritium monitors stationed in individual rooms and the readings are transmitted to a central computer. The data can be logged to a database (MS Access compatible) and will offer historical trends and necessary reports. This paper presents the main equipment s of the Tritium-in-Air Monitoring system, the description of this modernization project and the results of 3 H emissions monitoring program (Liquid & Gaseous Effluent Program Monitoring program at Cernavoda NPP). 1 INTRODUCTION During routine operation of a CANDU reactor, various gaseous, liquid, and solid radioactive wastes are generated. The design of its systems ensures that these are minimized, but small quantities of gaseous and liquid wastes are continuously discharged at very low concentrations. 508.1

CANDU reactors are both moderated and cooled by heavy water (D 2 O). Tritium is produced in CANDU reactors by neutron reactions with deuterium, boron, and lithium and by ternary fission. Activation of deuterium is by far the most important mechanism, which is responsible for the production of about 89 TBq of tritium per MW(e) per year compared to only 0.7 TBq of tritium per MW(e) per year produced by ternary fission. Most of the tritium present in CANDU reactors is in the form of tritiated heavy water DTO. Tritium is the radioactive isotope of hydrogen. It undergoes β decay to helium-3, with a half-life of approximately 12.33 years. Due to their low-energy (average of 5.7 kev and endpoint of 18.6 kev), tritium β particles have very small range less than approximately 6 mm in dry air or 6 µm in tissue. Outside the human body tritium contribution to radiological hazard is negligible however, when tritium enters the body either by inhalation or absorption through the skin the decay energy carried by the β particle is deposited in body tissue being an occupational radiation hazard in the station. [1] The sources of tritiated heavy water vapor in reactor building air are the leaks from the main reactor systems or their auxiliaries. Special dryers were designed and are used to remove moisture from different ventilation systems of a CANDU reactor in order to maintain the gaseous tritium emissions below the limits established by the national authorities. Tritium emissions are monitored both at the stack and in liquid discharges to demonstrate the compliance with the approved Derived Emission Limits. [2] A specialized laboratory using Liquid Scintillation Spectrometry methods currently determines tritium activities in effluent samples. All information about the radioactivity of liquid and gaseous effluent is stored into a dedicated database and used to make periodical reports of the official releases for the Cernavoda NPP U1 station. 508.2 2 TRITIUM-IN-AIR MONITORING 2.1 Tritium-in-Air Monitoring System ( 3 H-in-Air) It is a complex blend of electronic and pneumatic hardware, combined with large multiroom piping networks, which allows the operator to monitor separate rooms. The Tritium-in-Air Monitoring System (Scintrex Model 292) is designed to: - collect air samples from 24 separate areas in the Reactor Building and the Service Building (from a single station) where there is likely to be tritium; - indicate levels of tritium generally due to leakage of heavy water; - to assist in the location of D 2 O leak sources (operation performed by the operator). The Tritium-in-Air Monitoring system (Scintrex Model 292) mainly consists of two separate cabinets installed in Service Building (room S-226) and the following equipment: [3] - tritium sampling unit cabinet (PL1398); - tritium monitor/dryer unit cabinet (PL1394) - collection piping and 24 remote solenoid valves installed in different rooms; - manual valves (V11 & 25) to isolate the Reactor / Services Buidings (R/B or S/B) and Containment Isolation valves (SV 33 & 34) installed on the main sampling line coming out from the Reactor Building (R/B) - sampling station (SS1) where operator may take samples with a syringe. - calibrator and purging facilities: 2 N bottle, flexible hoses, quick-connectors, etc. The Tritium-in-Air Monitoring system is interconnected with Post Accident Sampling System (PASS), which consist of 9 (nine) valves and a sample tube in a shielded box. The Tritium-in-Air Monitoring system is also interconnected with Containment Isolation system. Two indicating lights on the tritium sampling unit (PL-1398) indicate the valve status.

508.3 Figure 1: Cernavoda NPP 3 H-in-Air Monitoring System Schematic Drawing 2.1.1 The Tritium Sampling Unit The Tritium Sampling Unit (PL-1398) located in S-226 near the fixed tritium monitor, contains all the necessary equipment to draw air samples and to control the remote solenoid valves in order to select the desired room. To avoid a long delay time in the pipe run from the monitored room to the sampling unit and to prevent condensation, a powerful vacuum pump (P1) provides an air sample with a flow rate of about 30 L/minutes. A set of two alternate filters (design change modification) is provided on line to retain particles in suspension to prevent damage of the vacuum pump (P1). Manual valves are provided for maintenance purposes, to isolate R/B or S/B samples. A vacuum switch (PS) is provided to give a "HIGH VACUUM IN LINE" alarm if the line is closed by malfunction of a solenoid valve, or Containment Isolation or a blocked line. A vacuum gauge allows the operator to check the line to ensure the status of vacuum. A "LEAK TEST" switch is also provided, to close the solenoid valves and check the leakage. If there is no practically leakage, the "HIGH VACUUM IN LINE" indicator will light (local alarm). A 24-position rotary switch with the corresponding LED indicator shows the room selected by the operator. All tubing is stainless steel (including the solenoid valves and the vacuum pump). Each remote solenoid valve is located in the monitored room. Monitoring coverage is provided in the reactor building and service building, in all areas where tritiated D 2 O could be collected. The purpose of this sub-system is to accelerate the delivery of the sample from the selected room to the fix tritium monitor.

508.4 2.1.2 The Tritium Monitor (Scintrex Model 275) / Dryer Unit The Tritium Monitor/Dryer cabinet (PL-1394) is subdivided into two units: - The tritium fix monitor covers the range of 1 to 2.04x10 7 µci/m 3. It has provisions for gamma subtraction; a digital display indicates the activity level in µci/m 3 ; local and MCR alarms are provided for system malfunctions and high tritium concentration; - The dryer unit is a complementary module to the fix monitor since the latter does not have any provisions for noble gas compensation. The exhaust pump (P2), a flowmeter (design flow rate - 5 L/min.), three filters and two dryers are located in the dryer unit (underneath the Detection unit). The dryer is conditioned by the cycle valve (V4), which can select wet or dry cycle. The dryer unit also contains a moisture indicator with silica gel, which can be replaced or regenerated. Sample air drawn into the Detection unit is passed through an electrically polarized ion trap to remove particles and extraneous ions. It is then passed through the outer chamber of a co-axial dual ionization chamber assembly. The beta particles in the sampled air ionize the air in the ionization chamber. The ionization current is proportional to the concentration of tritium in sampled air. The compensation for background gamma is done through a current provided by the inner chamber. The two signals are electronically subtracted to provide the net tritium signal. The measurement of the tritium activity is achieved manually in two steps: 1. One measurement is made with the cycle valve in the "wet" position; this measurement accounts for the tritium and noble gases. 2. One measurement is made with the cycle valve in the "dry" position; in this configuration the air sample from the pump cabinet is routed through the dryer section where the tritium is absorbed, and only the noble gases are measured. The difference between measurements 1 and 2 will yield the true tritium concentration. 2.2 Gaseous and Liquid Effluent Monitoring program (for 3 H emissions) Gaseous and liquid emissions from Cernavoda NPP were at low levels. Tritium emissions were also at low level (below 1% of annual DEL). [4] Tritium (as tritiated water) from gaseous effluents is continuously sampled on molecular sieve at the stack and is measured bi-weekly by liquid scintillation spectrometry method. During the pump-out of liquid effluents, the Liquid Effluent Monitor (LEM) monitors the gross gamma activity being discharged, and collects time-integrated samples from the discharge line for subsequent laboratory analysis of the actual releases. The samples collected by the LEM are taken to the station Health Physics laboratory for detailed radionuclide analysis. Tritium is analyzed by liquid scintillation spectrometry method. The results of this analysis constitute the official release results for the Cernavoda NPP station. 3 H gaseous emissions between July, 1997 and December, 2000 as determined by the effluent monitoring program and expressed in percents of Weekly Derived Emission Level percent (%WDEL) are presented in Figure 2.a. In Figure 2.b is presented the evolution of 3 H liquid emissions from January 1997 till December 2000 expressed in Monthly Derived Emission Level percent (%MDEL). Obviously the sequence of tritium emissions is time-dependent and evolves erratically around a growing trend. Based on this trend estimate, it is expected that in normal conditions emissions would be well below the operational limit of 5% DEL over the lifetime of the Cernavoda NPP plant.

508.5 Tritiumemissions, %WDEL Time (t), Tritium emissions % MDEL 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0 10 20 30 40 50 60 Time (t) months Figure 2.a Gaseous Emissions Figure 2.b Liquid Emissions Tritium emissions during this year - 2001 were also below 1% of WDEL. A statistical analysis of weekly tritium emission data revealed an erratic evolution around a growing trend due to the build-up in the main systems of the reactor. 8.00E-01 7.00E-01 6.00E-01 %WDEL 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 Media_2000 08-Jan-01 22-Jan-01 05-Feb-01 19-Feb-01 05-Mar-01 19-Mar-01 02-Apr-01 16-Apr-01 30-Apr-01 14-May-01 28-May-01 11-Jun-01 25-Jun-01 09-Jul-01 23-Jul-01 06-Aug-01 20-Aug-01 03-Sep-01 17-Sep-01 Week Figure 3: Weekly tritium emissions in 2001 3 MODERNIZATION AND IMPROVEMENT PROJECT The proposed configuration is based on 8 tritium monitors: one tritium monitor will replace the actual Scintrex Model 275 Fixed Tritium monitor, six monitors stationed in individual rooms (most hazardous areas) and one monitor installed on mobile cart with radio transmission. The readings of tritium concentration are transmitted through an RS-422 (RS-485) or local area network (LAN) to a central computer. The future locations will be established in areas where most frequent leaks can occur based on plant monitoring experience.

508.6 Figure 4 Proposed Configuration of 3 H monitoring network The data can be logged to a database (MS Access compatible) and will offer historical trends, which are very useful tool on the surveillance and operation of the process system. The tritium monitors must have the capability to provide compensation for gamma and noble gases (radioactive krypton and xenon), which are generally present with tritium in the station, and mask the tritium signal. The tritium monitors must have a local control panel to display the measurement and to give a local and remote alarm in Main Control Room if the activity level is above setpoint. Also, it must indicate an equipment failure in case it cannot function normally. The 3 H monitoring network will provide CRT monitor at the Equipment Airlock or in room S-226 (fix tritium monitor cabinet room) with a display of on-line 3 H monitoring activity levels for all 8 (eight) areas monitored. This facilities will eliminate the routine 3 H syringe samples performed by Radiation Control staff in those areas and will advise personnel of hazard prior to entry of any area. The Tritium-in-Air Monitoring system could be completed with a bubbler to collect samples for more accurate laboratory analyses by liquid scintillation spectrometry methods. 4. CONCLUSIONS A routine 3 H syringe samples (Chem. Lab and a network application Hazard Info) is used for assessment of 3 H hazards prior to entering an area to perform work. The proposed configuration provide on-line and real-time 3 H monitoring, so this system will be a very useful tool to implement one main element of the ALARA program: elimination of radioactive sources (fast detection of the 3 H hazards in areas monitored) and dose savings.

The new technologies (radiation 3 H monitoring network) will provide a cheaper, more efficient and safer nuclear power production (on long terms) due to: - savings of the tritium surveys costs: consumables (LSC method) and manpower (work load of Chem. Laboratory / Radiation Control section); - fast detection of D 2 O leaks in the monitored areas, which reduces the cost looses (D 2 O - very expensive) and Station Dose performance indicator. The 3 H monitoring network system can replace a large and expensive multi-room monitor piping system (present configuration at NPP U1), big advantage especially for NPP U2 Cernavoda (NPP U2 project started during this year). This modernization and improvement project at NPP U1 becomes more attractive from the financial aspects: common spare parts stock for both units, better price of the system from the manufacturer, etc. The same time, the 3 H monitoring network system will offer a database, historical trends, which are very useful tools on the surveillance and operation of the process systems. 508.7 REFERENCES [1] P.J. Allsop, K. Aydoglu, R. MacWilliams and J.M. Miller Tritium Source Identification in CANDU Reactors, Ontario, AECL, Canada [2] Canadian Standard Association, CAN/CSA N288.1 M87 Guidelines for Calculating Derived Release Limits for Radioactive Materials in Airborne and Liquid Effluents for Normal Operation of Nuclear Facilities, 1987 [3] Scintrex Ltd. USA, Operating and Maintenance Instruction Manual for Tritiumin-Air Monitoring System, Model 292, 1987 [4] E. Bobric, I. Popescu, V. Simionov, R. Ibadula, The Influence of Tritium Buildup in Cernavoda NPP Systems on Gaseous and Liquid Emissions After Four Years of Operation, Proc. IRPA Regional Congress on Radiation Protection in Central Europe, Dubrovnik, Croatia, May 20-25, 2001.