Available online at Pelagia Research Library. Advances in Applied Science Research, 2012, 3 (6):

Similar documents
A Computational study of Bingham plastic flow of Blood through an artery by multiple stenoses and post dilatation

Effect of body acceleration on pulsatile blood flow through a catheterized artery

Flow of a Casson Fluid Through an Inclined Tube of Non-uniform Cross Section with Multiple Stenoses

Biomagnetic Steady Flow through an Axisymmetric Stenosed Artery

Analytical Solutions of Unsteady Blood Flow of Jeffery Fluid Through Stenosed Arteries with Permeable Walls

Effect of Magnetic Field on Blood Flow (Elastico- Viscous) Under Periodic Body Acceleration in Porous Medium

Effect on the Flow of Bile Due to Radially Varying Viscosity in the Cystic Duct

Mathematical Modelling of Blood Flow through Catheterized Artery under the Influence of Body Acceleration with Slip Velocity

Blood flow through arteries in a pathological state: A theoretical study

Simulation of Variable Viscosity and Jeffrey Fluid Model for Blood Flow Through a Tapered Artery with a Stenosis

Effect of the plug flow on the flow characteristics of bile through diseased cystic duct: Casson Model Analysis

Oscillatory flow of a jeffrey fluid in an elastic tube of variable cross-section

Effect of Magnetic Field on Flow Behaviour of Blood through A Modelled Atherosclerotic Artery

MHD peristaltic transport of a micropolar fluid in an asymmetric channel with porous medium

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

Effect of Periodic Body Acceleration in Blood Flow through Stenosed Arteries A Theoretical Model

STUDY OF BLOOD FLOW THROUGH MODELLED VASCULAR STENOSIS

Effect of variable viscosity on the peristaltic flow of a Jeffrey fluid in a uniform tube

Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations

Suspension model for blood flow through a tapering catheterized inclined artery with asymmetric stenosis

Unsteady Flow of a Newtonian Fluid in a Contracting and Expanding Pipe

Study of blood flow through a catheterized artery

MHD OSCILLATORY SLIP FLOW AND HEAT TRANSFER IN A CHANNEL FILLED WITH POROUS MEDIA

Modeling of non-newtonian Blood Flow through a Stenosed Artery Incorporating Fluid-Structure Interaction

Modelling and simulation of micropolar fluid flow with variable viscosity through unhealthy artery

Research Article FDM Analysis for Blood Flow through Stenosed Tapered Arteries

PROBLEM SET 6. SOLUTIONS April 1, 2004

Mathematical Models and Numerical Simulations for the Blood Flow in Large Vessels

Hydromagnetic Blood Flow through a Uniform Channel with Permeable Walls Covered by Porous Media of Finite Thickness

Numerical Study of the Behaviour of Wall Shear Stress in Pulsatile Stenotic Flows

Effects of Magnetic Field and Slip on a Two-Fluid Model for Couple Stress Fluid Flow through a Porous Medium

Research Article Nonlinear Fluid Models for Biofluid Flow in Constricted Blood Vessels under Body Accelerations: A Comparative Study

MHD Free convection flow of couple stress fluid in a vertical porous layer

Numerical Analysis of MHD Flow of Fluid with One Porous Bounding Wall

Department of Mathematics, Amrita Vishwa Vidyapeetham (University), Karnataka , India

TABLE OF CONTENTS CHAPTER TITLE PAGE

Peristaltic flow of a Williamson fluid in an inclined planar channel under the effect of a magnetic field

INTERNATIONAL JOURNAL OF ADVANCE RESEARCH, IJOAR.ORG ISSN

Hydromagnetic oscillatory flow through a porous medium bounded by two vertical porous plates with heat source and soret effect

World Journal of Engineering Research and Technology WJERT

Impact of Magnetic Field Strength on Magnetic Fluid Flow through a Channel

Numerical modelling of shear-thinning non-newtonian flows in compliant vessels

Peristaltic pumping of couple stress fluid through non - erodible porous lining tube wall with thickness of porous material

Numerical Study of Blood Flow through Symmetry and Non- Symmetric Stenosis Artery under Various Flow Rates

MHD Pulsatile Slip Flow of Blood through Porous Medium in an Inclined Stenosed Tapered Artery in Presence of Body Acceleration

Numerical Solution of Mass Transfer Effects on Unsteady Flow Past an Accelerated Vertical Porous Plate with Suction

Study of modified Casson s fluid model in modeled normal and stenotic capillary-tissue diffusion phenomena

Effects of magnetic field and an endoscope on peristaltic motion

Numerical Study of Steady MHD Plane Poiseuille Flow and Heat Transfer in an Inclined Channel

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

Arterial Macrocirculatory Hemodynamics

NUMERICAL SOLUTION OF MHD FLOW OVER A MOVING VERTICAL POROUS PLATE WITH HEAT AND MASS TRANSFER

Analytical Solutions on the Flow of blood with the Effects of Hematocrit, Slip and TPMA in a porous tube

Structural Mechanics of Cooling Catheters

Peristaltic Pumping of a Casson Fluid in an Elastic Tube

Experimental Investigation on Characteristics of Non- Newtonian Fluids

Influence of velocity slip conditions on MHD peristaltic flow of a Prandtl fluid in a non-uniform channel

2, where dp is the constant, R is the radius of

Laminar Forced Convection Heat Transfer from Two Heated Square Cylinders in a Bingham Plastic Fluid

MUCUS TRANSPORT IN THE HUMAN LUNGS: A MATHEMATICAL ANALYSIS

Physics 207 Lecture 22. Lecture 22

TECHNISCHE UNIVERSITEIT EINDHOVEN Department of Biomedical Engineering, section Cardiovascular Biomechanics

Peristaltic transport of a newtonian fluid with wall properties in an asymmetric channel

Heat and Mass Transfer Effects of Peristaltic Transport of a Nano Fluid in Peripheral layer

MHD PERISTALTIC FLOW OF A COUPLE STRESS FLUIDS PERMEATED WITH SUSPENDED PARTICLES THROUGH A POROUS MEDIUM UNDER LONG WAVELENGTH APPROXIMATION

Stagnation Point Flow of Non-Newtonian Fluid and Heat Transfer over a Stretching/Shrinking Sheet in a Porous Medium

Similarity Flow Solution of MHD Boundary Layer Model for Non-Newtonian Power-Law Fluids over a Continuous Moving Surface

LOCAL THERMAL NON-EQUILIBRIUM FORCED CONVECTION OF A THIRD GRADE FLUID BETWEEN PARALLEL STRETCHING PERMEABLE PLATES EMBEDDED IN A POROUS MEDIUM

The effect of rigidity on torsional vibrations in a two layered poroelastic cylinder

Mathematical modelling of physiological flows

MODELING THE FLOW OF AQUEOUS HUMOR IN POSTERIOR CHAMBER. Ram Avtar, Swati Srivastava 1

Chapter 3 Non-Newtonian fluid

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

AIRLIFT BIOREACTORS. contents

Parash Moni Thakur. Gopal Ch. Hazarika

Effects of Heat Transfer on the Peristaltic Flow of Jeffrey Fluid through a Porous Medium in a Vertical Annulus

International Journal of Mathematical Archive-7(5), 2016, Available online through ISSN

Magnetic Effect on Slip Flow of Blood through Porous Medium with Time Dependent Permeability, Pulsatile Pressure and Body Acceleration

ME 309 Fluid Mechanics Fall 2010 Exam 2 1A. 1B.

Peristaltic Transport of a Magneto Non-Newtonian Fluid through A porous medium in a horizontal finite channel

BME 419/519 Hernandez 2002

Thermal diffusion effect on MHD free convection flow of stratified viscous fluid with heat and mass transfer

Slip Effect on Peristaltic Transport. of Micropolar Fluid

Application Of Optimal Homotopy Asymptotic Method For Non- Newtonian Fluid Flow In A Vertical Annulus

Numerical Simulation of Sinusoidal Fluctuated Pulsatile Laminar Flow Through Stenotic Artery

INFLUENCE OF HEAT TRANSFER ON PERISTALTIC FLOW OF JEFFREY FLUID THROUGH A POROUS MEDIUM IN AN INCLINED ASYMMETRIC CHANNEL

Biotransport: Principles

VISCOUS FLUID FLOW IN AN INCLINED CHANNEL WITH DEFORMABLE POROUS MEDIUM

Pharmaceutical compounding I Colloidal and Surface-Chemical Aspects of Dosage Forms Dr. rer. nat. Rebaz H. Ali

DEVELOPED LAMINAR FLOW IN PIPE USING COMPUTATIONAL FLUID DYNAMICS M.

arxiv: v1 [physics.flu-dyn] 16 May 2014

University of Washington Department of Chemistry Chemistry 453 Winter Quarter 2013

Lecture 2: Hydrodynamics at milli micrometer scale

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

G. C. Hazarika 2 Department of Mathematics Dibrugarh University, Dibrugarh

MHD Non-Newtonian Power Law Fluid Flow and Heat Transfer Past a Non-Linear Stretching Surface with Thermal Radiation and Viscous Dissipation

Modeling of arterial stenosis and its applications to blood diseases

On the Boundary Layer Flow of a Shear Thinning Liquid over a 2-Dimensional Stretching Surface

Casson Fluid Flow and Heat Transfer Past a Symmetric Wedge

FLUID FLOW IDEAL FLUID EQUATION OF CONTINUITY

Transcription:

Available online at www.pelagiaresearchlibrary.com Pelagia esearch Library Advances in Applied Science esearch, 212, (6:551-557 Bingham Plastic characteristic of blood flow through a generalized atherosclerotic artery with multiple stenoses S. S. Yadav and Krishna Kumar ISSN: 976-861 CODEN (USA: AASFC Narain (P.G. College, Shikohabad (India ABSTACT In this paper, we have investigated the effects of length of stenosis, shape parameter, parameter on the resistance to flow for a Bingham plastic flow of blood through a generalized artery having multiple stenoses locate at equal distances. Here, the rheology of the flowing blood is characterized by non-newtonian fluid model. The study reveals that flow resistance decreases as shape parameter and increases and it increases as stenosis height and length increase. We have also shown the variation of wall shear stress for different values of parameter. Keywords: esistance to flow, wall shear stress, stenosis, shape parameter INTODUCTION Hardening of the arteries is a procedure that often occurs with aging. As we grow older, plaque buildup narrows our arteries and makes them stiffer. These changes make it harder for blood to flow through them. Clots may form in these narrowed arteries and block blood flow. Pieces of plaque can also break off and move to smaller blood vessels, blocking them. Either way, the blockage starves tissues of blood and oxygen, which can result in damage or tissue death. This is a common cause of heart attack and stroke. High blood cholesterol levels can cause hardening of the arteries at a younger age. For many people, high cholesterol levels are the result of an unhealthy lifestyle most commonly, eating a diet that is high in fat. Other risk factors are heavy alcohol use, lack of exercise, and being overweight. Singh [1] observed that flow resistance decreases as shape parameter and increases and it increases as stenosis height and length increase. He has also shown that wall shear stress increases up to mid axial distance and then it decreases for increasing values of parameter. Singh and Singh [2] discussed the effects of flow behavior indices on non Newtonian blood flow in small arteries having multiple stenoses and post-stenotic dilatation has been discussed. They observed that as flow index behavior increases, rate of flow resistance ratio increases. Singh et al. [] assumed the stenosis is mild and radially non-symmetric. They performed the graphical analysis for a single loop of stenosis having maximum depression at different point. They also observed that increasing value of parameter shows lower variation. Singh and Shah [4] presented a numerical model to investigate the effect of shape of stenosis on blood flow through an artery using power-law fluid model. They found that the resistance to flow, wall shear stress and apparent viscosity decreases as stenosis shape parameter increases but increases as stenosis size and stenosis length increases. Krishna et al. [5] discussed the effects of various parameters like Darcy number, slip parameter, radius on velocity, frictional force. They obtained expressions for velocity, volume flow rate and Pelagia esearch Library 551

S. S. Yadav et al Adv. Appl. Sci. es., 212, (6:551-557 frictional forces. Shah [6] presented a numerical model to determine the effect of magnetic field on blood flow through an axially non-symmetric but radially symmetric atherosclerotic artery. She has also shown that in the presence of magnetic field, blood did not drastically change the flow patterns, but caused an appreciable decrease in the shear stresses and a slightly lower resistance to flow. Mishra and Verma [7] investigated the wall shear stress, resistance parameter and flow rate across mild stenosis situated symmetrically on steady blood flow through blood vessels with uniform or non-uniform cross-section by assuming the blood to be Non-Newtonian, incompressible and homogeneous fluid. Misra and Shit [8] developed a mathematical model for studying the non-newtonian flow of blood through a stenosed arterial segment. They noticed that the resistance of flow and the skin-friction increase as the stenosis height increases. Bali and Awasthi [9] studied flow of blood through a multistenosed artery under the influence of external applied magnetic field. They observed the effect of magnetic field, height of stenosis, parameter determining the shape of the stenosis on velocity field, volumetric flow rate in stenotic region. Sarojamma et al. [1] studied the influence of body acceleration on the flow of blood through a stenosed catheterized artery. They found that the insertion of a catheter and yield stress of the fluid increase the resistance to flow enormously depending upon the size of catheter. Singh and Singh [11] considered a fully developed one dimensional Bingham plastic flow of blood through a small artery having multiple stenoses and post-stenotic dilatation. They observed that the resistance- to - flow moves nearer to unity as yield stress increases and flux decreases. Variation in viscosities shows no significant change in esistance to-flow ratio. MATHEMATICAL FOMULATION Let us consider an artery with stenosis symmetrical about the axis but non-symmetrical with respect to radial coordinates. The mathematical expression for geometry is given by = 1 ε L z nd n 1 l z nd n 1 L n( d + L L z n( d + L { ( } { ( } s 1 ; = 1 ; Otherwise (1 Where, are tube radius (with, without stenosis, s 2 is a shape parameter determining stenosis shape, L is stenosis length, d indicates its location. n is the number of stenosis in the artery, is a positive number greater and equal than 1. s ε = δ s s/ s 1 s L ( s 1 δ be the maximum height of the stenosis at 1/ s 1 nd + ( n 1 L + L / s z = (2 Pelagia esearch Library 552

S. S. Yadav et al Adv. Appl. Sci. es., 212, (6:551-557 The constitutive equations for Bingham plastic fluid are β = f ( = = µ dr Fig.1: Geometry of Artery with multiple Stenoses du & ( The flux Q through the artery is given by Q 2π rudr = (4 u = when r = Integrating (4 and using the no-slip boundary condition 2 du Q = π r dr (5 dr Applying ( in (5 to obtain 2 Q = π r f ( dr (6 The expressions for and (the shear at the wall i.e. when r = is given by r dp dp = and = (7 2 dz 2 dz Where p is the pressure. From equations ( and (6, we get π 2 Q = f ( dr (8 Substitution of equation ( and rearrangement gives the result 4 π 4µ Q 4 Q = = + (9 µ 4 π Using the second result of equation (7 dp 2 4µ Q 4 = dz + π (1 Pelagia esearch Library 55

S. S. Yadav et al Adv. Appl. Sci. es., 212, (6:551-557 dp 8µ Q 8 1 = 4 (11 dz π Integrating equation (11 with respect to z with the condition that p = p 1 at z = and p = p at z = l 4 1 8µ Q L 8 L 1 = 4 π 4 1 p1 p 8µ L 8 L = = dz 4 Q π Q p p dz dz λ Suppose f 8µ 8 = ; f = 4 π Q 1 2 n( d + L L n( d + L 4 4 4 n= nmax L n= 1 n( d + L L n( d + L λ = f1 dz + dz + dz n( d + L L n( d + L 1 1 1 n= nmax L n= 1 n( d + L L n( d + L (14 f2 dz + dz + dz Taking n = 1, we get L λ = ( f + f L ( f I + f I 1 2 1 1 2 2 (15 n( d + L n( d + L 4 Where I1 = dz, I2 n( d + L L n( d + L L If there is no stenosis i.e. in the normal condition, we have N ( f1 f2 L The resistance to flow is given by dz = λ = + (16 λ L f I + f I λ = = + 1 1 2 2 λ L ( f + f L N 1 (17 1 2 1 dz (12 (1 Pelagia esearch Library 554

S. S. Yadav et al Adv. Appl. Sci. es., 212, (6:551-557 From eq. (7 and (1, the wall shear stress is given by Wall shear stress in normal situation is written as 4µ Q 4µ Q 4 = + π N = (19 π The wall shear stress ratio can be obtained as π 4µ Q 4 1 π = = N 4µ Q + π = + µ Q The wall shear stress ratio at the mid point of the stenosis is 1 π 1 = + µ Q δ 1 NUMEICAL ESULTS (18 (2 (21 Fig.2. esistance to flow with stenosis height for different values of stenosis lengths and Pelagia esearch Library 555

S. S. Yadav et al Adv. Appl. Sci. es., 212, (6:551-557 Fig.. esistance to flow with stenosis shape for different stenosis heights and parameter Fig.4. Wall shear stress with axial distance for different value of CONCLUSION In the present study, we have derived an analytic relation for resistance to flow for Bingham plastic flow of blood through an artery with multiple stenoses situated at the points of equal distance. For enhanced perceptive of the problem the graph has been plotted for a single loop of artery. It is observed that growing of shows the minor variations for different values of stenosis height in addition to stenosis length. Pelagia esearch Library 556

S. S. Yadav et al Adv. Appl. Sci. es., 212, (6:551-557 EFEENCES [1] Singh A.K, Advances in Applied Mathematical Biosciences, 212, (1, 41-48 [2] Singh A.K, Singh D.P, International Journal of Advanced Computer and Mathematical Sciences, 212, (, 5-9 [] Singh B., Joshi P., Joshi B.K, Applied Mathematical Sciences, 21, 4(22, 165-172 [4] Singh S, Shah., Advances in Applied Science esearch, 21, 1(1, 66-7 [5] Krishna Kumari S.V.H.N, evankar S.M, avi Kumar Y.V.K., Advances in Applied Science esearch, 212, (4, 2159-2168 [6] Shah S., International Journal on Pharmaceutical and Biomedical esearch, 211, 2(, 96-16 [7] Mishra B.K, Verma N., Australian Journal of Basic and Applied Sciences, 21, 4(4, 588-61 [8] Misra J.C, Shit G.C, International Journal of Engineering Science, 26, 44, 662 671 [9] Bali., Awasthi U., Applied Mathematics, 212, (5, 46-441 [1] Sarojamma G., Vishali B., amana B., Int. J. of Appl. Math and Mech.,212, 8 (11, 1-17 [11] Singh A.K., Singh, D.P., Advances in Applied Science esearch, 212, (5, 285-29 Pelagia esearch Library 557