It s hot! ZIC -chilic

Similar documents
HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Do you need trouble-free speed? The NEW Chromolith HR

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS

Do you need trouble-free speed? The NEW Chromolith HR

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

LC Columns with Liquid Separation Cell Technology

Small Molecule Selectivity Sampler

for Acclaim Mixed-Mode HILIC-1 Column

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

ProPac WCX-10 Columns

Acclaim Mixed-Mode WAX-1 Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Shodex TM ODP2 HP series columns

Advantages of polymerbased. an alternative for ODS

Determination of trace anions in concentrated hydrofluoric acid

Too Polar for Reversed Phase What Do You Do?

Acclaim Mixed-Mode WCX-1

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

for Acclaim Mixed-Mode WCX-1

Routine MS Detection for USP Chromatographic Methods

Acclaim AmG C18 Column

LC Technical Information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Alltech Alltima HP Introduction

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Comparison of different aqueous mobile phase HPLC techniques

Cation Exchange HPLC Columns

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Cation Exchange HPLC Columns

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Technical Guide Thermo Scientific Syncronis HPLC Columns

for Acclaim Trinity TM P1

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

C18 Column. Care & Use Sheet

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Fluophase and Fluofix Columns

Gemini-NX Performance paired with Axia Technology

High Performance Liquid Chromatography

High Performance Liquid Chromatography

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Dionex IonPac AS28-Fast-4µm column

C190-E105 Printed in Japan ATD

Optimisil HPLC & UPLC Column catalogue

Method Development Kits

Chemistry Instrumental Analysis Lecture 37. Chem 4631

State-of-the-art C18 HPLC Columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

columns IonPac SCS 1 Silica Cation Separator

1.7 m Fortis UHPLC Columns

The Theory of HPLC. Ion Pair Chromatography

Mechanisms of retention in HPLC

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

PolyHYDROXYETHYL Aspartamide for Hydrophilic Interaction Liquid Chromatography(HILIC)

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

High Performance Liquid Chromatography

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Dilution(*) Chromatography

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Method Development with ZirChrom's Ion Exchange Phases

Saccharides and Organic Acids

HILIC Method Development in a Few Simple Steps

The Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC

Method Development Guide. A Step by Step Approach to Developing Reproducible HILIC Methods + + ACE HILIC Method Development Guide

Biochemistry. Biochemical Techniques HPLC

High Performance Liquid Chromatography

HPLC Background Chem 250 F 2008 Page 1 of 24

Acclaim HILIC-10 Columns

ION CHROMATOGRAPHY SYSTEM S 150

anion-exchange column

and water enriched layer at the stationary phase particle-eluent interface [9,11].

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

columns IonPac AS17-C Anion Exchange Column

Next Generation of Phenyl Columns. Chromatography Products.

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Packings for HPLC. Packings for HPLC

Definitive EtG/EtS LC-MS/MS Analysis:

Transcription:

It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany

ZIC -chilic Your benefits High-performance HILIC column Complementary selectivity for polar hydrophilic compounds Maximum LC-MS compatibility with minimized column bleed Excellent reproducibility and robustness ZIC -chilic is designed for excellent HPLC and LC-MS analysis of polar hydrophilic compounds. This new zwitterionic stationary phase with phosphorylcholine functional group provides you with complementary selectivity for easier method development for substances that have been difficult to separate by previous types of HPLC columns operated in reversed-phase or HILIC mode. The selectivity features of ZIC -chilic are especially beneficial for negatively charged polar compounds such as nucleotides and organic acids, but do also provide advantageous separations of positively charged hydrophilic molecules, for example, aminoglycosides and cations. The column is also very suitable for zwitterionic and neutral polar hydrophilic substances. Benefit from easier method development with complementary selectivity from hydrophilic partitioning and weak ionic interactions 2

As a true zwitterionic stationary phase, ZIC -chilic shows weak electrostatic interactions (attraction and repulsion) for favorable selectivity thanks to its 1:1 charge balance in close proximity. The weak electrostatic interactions enable separation tuning and optimization at low buffer concentrations in mobile phases without interfering with detection techniques, including mass spectrometry (MS). ZIC -chilic shows maximum mass spectrometry compatibility by its totally minimized column bleed. The very long column lifetime and superb batch-to-batch reprodu cibility make it a powerful choice for LC-MS and HPLC analysis of numerous polar hydrophilic compounds. 3

Complementary selectivity of ZIC -chilic The selectivity of ZIC -chilic is complementary to ZIC -HILIC and other types of HILIC columns. Charged polar hydrophilic compounds typically experience significant selectivity differences on ZIC -chilic versus ZIC -HILIC due to their differently oriented zwitterionic functional groups. The outermost, more accessible charged moiety tend to dominate the interaction with solutes. Positively charged compounds thus typically have lower retention on ZIC -chilic whereas negatively charged compounds have higher retention. Neutral compounds tend to experience more similar retention on the two zwitterionic columns. ZIC -chilic ZIC -HILIC Isocratic separations of the positively charged benzyltrimethylamine (BTMA, peaks indicated with arrows) and the neutral toluene (void marker), uracil and cytosine on ZIC -chilic (left) and ZIC -HILIC (right) illustrating differences and similarities in selectivity caused by the different charge orientation of the zwitterionic functional groups (see illustrations). Column dimensions were 100 x 4.6 mm, particles size 3 or 3.5 µm, and pore size 100 Å. Eluent was 80:20 acetonitrile/ 25 mm aqueous ammonium acetate ph 6.8 pumped at 0.5 ml/min at 23 C. Detection by UV absorption at 254 nm. The selectivity of ZIC -chilic is complementary to ZIC -HILIC and other types of HILIC columns 4

HPLC of Nucleotides and Nucleosides ZIC -chilic can accomplish impressive separation and peak shape of nucleotides thanks to the zwitterionic character of its phosphorylcholine functional groups. The stationary phase provides advantageous weak ionic interactions for enhanced selectivity, without excessive retention or serious peak shape distortion. On other types of HILIC columns, the negative charges of the nucleotides phosphate groups can interact strongly with anion exchange sites, resulting in excessive retention or severe peak tailing, making purification and quantification problematic. Isocratic separations on ZIC -chilic 100 x 2.1 mm (VWR Cat. No. 52428-722) operated at 23 C with a flow rate of 0.4 ml/min. Eluent was acetonitrile/100 mm aqueous ammonium acetate ph 4.5, with acetonitrile ratios of 60 %, 65 %, 70 % and 75 %, respectively (top to bottom). Injection of 5 µl of adenosine, AMP, ADP, ATP diluted in eluent. UV detection at 254 nm. ZIC -chilic provides enhanced selectivity for nucleotides and many other negatively charged compounds Comparison to ZIC -HILIC Nucleosides can also be nicely separated on ZIC -HILIC but tend to be less retained due to slight repulsion from the outermost, more accessible, negative charge on its zwitterionic sulfobetaine functional groups. Isocratic separation on ZIC -HILIC 100 x 2.1 mm (VWR Cat. No. 10144-126) used at identical conditions as above with 75 % acetonitrile in the eluent. 5

LC-MS of Aminoglycoside Antibiotics Thanks to the high hydrophilicity and favorable weak repulsion electrostatic interactions, with ZIC -chilic columns, it is possible to achieve excellent separation of multiple structurally similar aminoglycosides in a minimum amount of time. In an LC-MS set-up, ZIC -chilic columns enable quantification of low amounts of aminoglycoside antibiotics in various samples. Aminoglycoside antibiotics contain amino-modified sugar moieties and they are thus very hydrophilic and bear multiple positive charges at neutral and acidic phs. This makes them very difficult to separate and analyze using reversed-phase and most types of HILIC HPLC columns. Paromomycin (PAR) Neomycin (NEO) Gradient LC-MS on ZIC -chilic 100 x 2.1 mm (VWR Cat. No. 52428-722) operated at 50 C with a flow rate of 0.4 ml/ min. Mobile phases were A: acetonitrile with 1 % (w/w) formic acid and B: 100 mm ammonium acetate with 3 % (w/w) formic acid. Gradient was 50 to 95 % B 0-7 min, 95 % B 7-8 min, 95-50 % B 8-16 min (equilibration). Injection of 5 µl 5 µg/ml streptomycin (STR), 25 µg/ml gentamycin (GEN), paromomycin (PAR), tobramycin (TOB), and neomycin (NEO), all diluted in 30:70 (v/v) acetonitrile/milli-q water. Detection by Shimadzu LCMS 2012EV, detector voltage: 2.0 kv, heat block and CDL temp: 250 C, SIM in positive mode: m/z 582 (STR), 464 (GEN), 616 (PAR), 468 (TOB), and 615 (NEO). Maximum LC-MS compatibility ZIC -chilic HPLC columns have extraordinary low column bleed in LC-MS. Many HILIC columns including several marketed as zwitterionic tend to display 70 240 % higher bleed than ZIC -chilic. This can cause signal suppression and interfere with quantification while increasing MS instrument wear and service costs. Column bleed (Mcps) EMD Millipore Mass spectrometry intensity data from ESI+ with single quadrupole MS measured as total ion cur - rent for 20-2000 m/z. Columns were 100 x 2.1 mm operated at 50 C with a flow rate of 0.1 ml/ min. Eluent was 80:20 acetonitrile/25 mm aqueous ammonium acetate ph 6.8. Average of 3 measurements, each during 6 minutes. All columns were allowed to equilibrate 1-2 hours until baseline had stabilized before measurement. 6

HPLC of Amino Acids The selectivity of ZIC -chilic is suitable for separating a wide range of amino acids without any p re-column derivatization reactions or ion-pair reagents in the eluent. Amino acids with hydrophilic as well as hydrophobic side chains will retain and can be separated, as can positional isomers. Isocratic separation of amino acids using ZIC -chilic 150 x 4.6 mm (VWR Cat. No. 52428-730) and a mobile phase containing 80:20 acetonitrile/25 mm ammonium acetate ph 6.8, delivered at a flow rate of 1 ml/min, at 23 C. Detection by UV at 254 nm. Injection of 1 µl standard mixture with tryptophan, tyrosine and 3,4-dihydroxyphenylalanine dissolved in 80:20 acetonitrile/water, acidified with 1 % phosphoric acid. tryptophan (1) tyrosine (2) 3,4-dihydroxyphenylalanine (3) HPLC of Organic Acids ZIC -chilic is very appropriate for HPLC analysis of small organic acids. Mono-acids, di-acids, and tri-acids can be separated in the same run with high selectivity and resolution. This enables quantification of organic acids in a wide range of samples with a variety of different detection techniques depending on targeted concentration range. This example with UV absorbance detection shows analysis of organic acids in white wine. 1 Acetic acid 2 Succinic acid 3 Malic acid 4 Tartaric acid 5 Citric acid Isocratic HPLC analysis of organic acids on ZIC -chilic 150x2.1 mm (VWR Cat. No. 52428-724). Mobile phase was 75:25 acetonitrile/25 mm potassium phosphate buffer ph 6.0, delivered at 0.3 ml/min, at 30 C. Injection of 5 µl standard mixture containing 10 ppm each of acetic acid (1; 2.4 min), succinic acid (2; 3.9 min), malic acid (3; 5.5 min), tartaric acid (4; 6.0 min) and citric acid (5; 8.9 min) diluted in mobile phase (upper trace), and Riesling wine diluted in water 1:10 and then in acetonitrile 1:10 (bottom trace). Asterisks (*) indicates impurities in standards. Detection by UV at 200 nm using a 2.5 µl semi-micro flow-cell. Total system void time was 1.0 min. 7

High column stability ZIC -chilic shows very high stability and can stand more than 1600 injections during 270 hours of continuous use without showing any signs of change in retention. Its high robustness ensures that you get reproducible chromatography from your column with every injection. Retention factors of uracil (bottom) and cytosine (top) on ZIC -chilic (VWR Cat. No. 52428-730) 150 x 4.6 mm operated at 23 C with a flow rate of 0.5 ml/min. Eluent was 80:20 acetonitrile/25 mm aqueous ammonium acetate ph 6.8. Injection of 10 µl toluene (void marker), uracil and cytosine in eluent every 12 minutes. Detection by UV absorbance at 254 nm. Superb batch-to-batch reproducibility A strictly controlled synthesis procedure gives ZIC -chilic superb batch-to-batch reproducibility so you can rely on your methods delivering consistent results year in and year out. Isocratic separation on three different sorbent batches of ZIC -chilic (VWR Cat. No. 52428-724) 150 x 2.1 mm operated at 23 C with a flow rate of 0.1 ml/min. Eluent was 80:20 acetonitrile/25 mm aqueous ammonium acetate ph 6.8. Injection of 5 µl toluene (void marker), uracil and cytosine in eluent. Detection by UV absorbance at 254 nm. 8

Analytical columns Description VWR Cat. No. Particle size Pore size Dimension length Dimension i.d. Column hardware Contents of one package ZIC -chilic 52428-720 3 µm 100 Å 50 mm 2.1 mm PEEK 1 piece ZIC -chilic 52428-722 3 µm 100 Å 100 mm 2.1 mm PEEK 1 piece ZIC -chilic 52428-724 3 µm 100 Å 150 mm 2.1 mm PEEK 1 piece ZIC -chilic 52428-726 3 µm 100 Å 50 mm 4.6 mm PEEK 1 piece ZIC -chilic 52428-728 3 µm 100 Å 100 mm 4.6 mm PEEK 1 piece ZIC -chilic 52428-730 3 µm 100 Å 150 mm 4.6 mm PEEK 1 piece ZIC -chilic 52428-732 3 µm 100 Å 250 mm 4.6 mm PEEK 1 piece ZIC -chilic Guard Kit* 52428-734 5 µm 100 Å 20 mm 2.1 mm PEEK 3 pieces *including column coupler Capillary columns Description VWR Cat. No. Particle size Pore size Dimension length Dimension i.d. Column hardware Contents of one package ZIC -chilic Capillary 52428-742 3 µm 100 Å 150 mm 300 µm GL-SS 1 piece ZIC -chilic Capillary 52428-710 3 µm 100 Å 150 mm 1 mm GL-SS 1 piece ZIC -chilic 52428-736 5 µm 100 Å 5 mm 300 µm GL-SS 3 pieces Capillary Guard ZIC -chilic Capillary Guard 52428-738 5 µm 100 Å 5 mm 1 mm GL-SS 3 pieces PEEK = Poly-ether-ether-ketone column with PEEK frits. GL-SS = glass-lined stainless steel with stainless steel frits. Every column (except guards) is individually tested and delivered with a certificate of analysis documenting its performance. Example references: S. Di Palma et al., Anal. Chem., 83 (2011) 3440-3447. G. Weber et al., J. Sep. Sci., 31 (2008) 1615-1622. 9

We provide information and advice to our customers on application technologies and regulatory matters to the best of our knowledge and ability, but without obligation or liability. Existing laws and regulations are to be observed in all cases by our customers. This also applies in respect to any rights of third parties. Our information and advice do not relieve our customers of their own responsibility for checking the suitability of our products for the envisaged purpose. www.vwr.com/emdmillipore-chromatography EMD Millipore, the M logo and ZIC are registered trademarks of Merck KGaA, Darmstadt, Germany. LAm-16-12746 07/2016 2016 EMD Millipore Corporation, Billerica MA USA. All rights reserved. 0816 Lit No. 051647W