Molecular Constants of CO by Infrared Spectroscopy

Similar documents
Vibrations of Carbon Dioxide and Carbon Disulfide

Vibrational and Rotational Analysis of Hydrogen Halides

VIBRATION-ROTATION SPECTRUM OF CO

NORTH CAROLINA STATE UNIVERSITY Department of Chemistry. Physical Chemistry CH437 Problem Set #4 Due Date: September 22, 2015

The Vibrational-Rotational Spectrum of HCl

INFRARED ABSORPTION SPECTROSCOPY. References: See relevant sections in undergraduate text. Learn from your instructor how to use the spectrometer.

Dissociation energy of the C-H bond in chloroform

Vibration-Rotation Spectrum of HCl

Experiment 4 INFRARED SPECTROSCOPY

Advanced Chemistry 2008

Experiment 3: The Rovibrational Spectrum of HCl (was Experiment 4 in the syllabus, but the original Experiment 3 was canceled)

Physical Chemistry Laboratory II (CHEM 337) EXPT 9 3: Vibronic Spectrum of Iodine (I2)

Molecular energy levels and spectroscopy

Physical Chemistry II Laboratory

THE VIBRATIONAL SPECTRA OF A POLYATOMIC MOLECULE (Revised 3/27/2006)

CHM Physical Chemistry II Chapter 12 - Supplementary Material. 1. Einstein A and B coefficients

EXPERIMENT 12. SPECTROSCOPIC STUDIES OF HCL AND DCL

Physical Chemistry Lab II CHEM 4644 Spring 2011 Final Exam 5 questions at 3 points each equals 15 total points possible.

QUANTUM CHEMISTRY PROJECT 3: PARTS B AND C

Synthesis and Infrared Spectrum of Nitric Oxide 1

V( x) = V( 0) + dv. V( x) = 1 2

5.61 Physical Chemistry Final Exam 12/16/09. MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Chemistry Physical Chemistry

( )( s 1

24/ Rayleigh and Raman scattering. Stokes and anti-stokes lines. Rotational Raman spectroscopy. Polarizability ellipsoid. Selection rules.

Vibrational-Rotational Spectroscopy. Spectroscopy

Experiment #1: Molecular Spectroscopy of Acetylene

Diphenylpolyene Dye Spectra

Chemistry 881 Lecture Topics Fall 2001

The Iodine Spectrum. and

2. Infrared spectroscopy

Chemistry 483 Lecture Topics Fall 2009

Molecular spectroscopy Multispectral imaging (FAFF 020, FYST29) fall 2017

THE VIBRATIONAL SPECTRUM OF A POLYATOMIC MOLECULE (Revised 4/7/2004)

CHAPTER 13 LECTURE NOTES

5.80 Small-Molecule Spectroscopy and Dynamics

Lecture 4: Polyatomic Spectra

THEORY OF MOLECULE. A molecule consists of two or more atoms with certain distances between them

Experiment 6: Vibronic Absorption Spectrum of Molecular Iodine

Spectra of Atoms and Molecules. Peter F. Bernath

SIMPLE QUANTUM SYSTEMS

Vibronic Spectra of Diatomic Molecules and the Birge-Sponer Extrapolation

Atomic spectra of one and two-electron systems

1901 Application of Spectrophotometry

ChemWiki BioWiki GeoWiki StatWiki PhysWiki MathWiki SolarWiki

Introduction to Molecular Vibrations and Infrared Spectroscopy

Chemistry 2. Assumed knowledge

( ) electron gives S = 1/2 and L = l 1

Exercises 16.3a, 16.5a, 16.13a, 16.14a, 16.21a, 16.25a.

Chem120a : Exam 3 (Chem Bio) Solutions

6.2 Polyatomic Molecules

Vibrational spectroscopy., 2017 Uwe Burghaus, Fargo, ND, USA

Appendix D Simulating Spectroscopic Bands Using Gaussian and PGopher

Lecture 8. Assumed knowledge

AN EXAMPLE REPORT. Cecil Dybowski List all names of people involved, along with addresses.

Vibrational states of molecules. Diatomic molecules Polyatomic molecules

Literature values: ΔH f, gas = % error Source: ΔH f, solid = % error. For comparison, your experimental value was ΔH f = phase:

Infrared Spectroscopy

Spectroscopic techniques: why, when, where,and how Dr. Roberto GIANGIACOMO

Vibrational Raman Spectroscopy

Follow this and additional works at: Part of the Chemistry Commons

Principles of Molecular Spectroscopy

Wolfgang Demtroder. Molecular Physics. Theoretical Principles and Experimental Methods WILEY- VCH. WILEY-VCH Verlag GmbH & Co.

Physical Chemistry II Exam 2 Solutions

NPTEL/IITM. Molecular Spectroscopy Lecture 2. Prof.K. Mangala Sunder Page 1 of 14. Lecture 2 : Elementary Microwave Spectroscopy. Topics.

What happens when light falls on a material? Transmission Reflection Absorption Luminescence. Elastic Scattering Inelastic Scattering

Introduction. Quantum Mechanical Computation. By Sasha Payne N. Diaz. CHEMISTRY 475-L03 1 January 2035

Chapter 6 Vibrational Spectroscopy

Infrared Spectra of Triatomics CH342L: Spectroscopy February 18, 2016

Effect of mass attached to the spring: 1. Replace the small stopper with the large stopper. Repeat steps 3-9 for each spring set.

6.05 Computational Raman Spectroscopy

IFM Chemistry Computational Chemistry 2010, 7.5 hp LAB2. Computer laboratory exercise 1 (LAB2): Quantum chemical calculations

16.1 Molecular Vibrations

Calculating Bond Enthalpies of the Hydrides

Chapter4: Quantum Optical Control

5.3 Rotational Raman Spectroscopy General Introduction

Chem 442 Review of Spectroscopy

Rotational Raman Spectroscopy

NPTEL/IITM. Molecular Spectroscopy Lectures 1 & 2. Prof.K. Mangala Sunder Page 1 of 15. Topics. Part I : Introductory concepts Topics

Collisionally Excited Spectral Lines (Cont d) Diffuse Universe -- C. L. Martin

P. W. Atkins and R. S. Friedman. Molecular Quantum Mechanics THIRD EDITION

Lab 12 Pressure-Temperature Relationship in Gases

Workshop 4: Diatomic molecule vibrational and rotational spectra CH351 Physical Chemistry, Fall 2004

Investigation 5: Infrared Spectroscopy and Molecular Modeling

Chapter: 22. Visualization: Making INPUT File and Processing of Output Results

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

USING THE OCEAN OPTICS R-2000 RAMAN SPECTROMETER IN THE UNDERGRADUATE LABORATORY

Fourier transforms of molecular vibrations

2: SIMPLE HARMONIC MOTION

Chemistry 21b Final Examination

Jasco V-670 absorption spectrometer

A56. Raman Spektroscopy. Jan Publisher: Institute of Physical Chemistry

Investigation 5: Infrared Spectroscopy and Molecular Modeling

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Chem 3502/4502 Physical Chemistry II (Quantum Mechanics) 3 Credits Spring Semester 2006 Christopher J. Cramer. Lecture 10, February 10, / 4

Introductory Physical Chemistry Final Exam Points of Focus

Tuning Color Through Substitution

Lecture 10 Diatomic Vibration Spectra Harmonic Model

MOLECULAR SPECTROSCOPY

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Fluorescence Spectrophotometry

Transcription:

Molecular Constants of CO by Infrared Spectroscopy Purpose This experiment uses infrared spectroscopy to determine the bond length, vibration frequency, anharmonicity, and other properties of the carbon monoxide molecule. Also, molecular properties are calculated using ab initio quantum mechanics. Introduction Diatomic molecules are valuable test cases for understanding molecular bonding and spectroscopy. Because a diatomic molecule is necessarily linear and has only one vibrational mode, its vibrationrotation spectrum is relatively simple. The equilibrium bond length, rotation constant, and harmonic vibration frequency are easily obtained from spectra. More subtle effects such as vibrational anharmonicity and vibration-rotation coupling can also be extracted from infrared spectra. Quantum-chemical methods are tested by comparing calculated properties to results from spectra. Theory The rotation-vibration energy of CO is approximately the sum of harmonic-oscillator energy and rigid-rotor energy: E hνe(v+½) + h2j(j+1)/(8π2μre2) ; v=0,1,2,... ; J=0,1,2,... (1) v is the vibration quantum number J is the rotation quantum number νe is the fundamental vibration frequency = (k/μ)1/2 /(2π). νe is in units of s-1. ωe is the fundamental vibration frequency in wavenumbers, cm-1. ωe = νe /c, where c is the speed of light. μ is the CO reduced mass. µ = mcmo/(mc+mo) Re is the equilibrium bond length In wavenumber units, E ωe(v+½) + h J(J+1)/(c8π2μRe2) ; v=0,1,2,... ; J=0,1,2,... (2) Units of wavenumbers are convenient because infrared spectra are usually recorded in wavenumbers. Notice that E = E/(hc) and ωe = 1/λ. The equilibrium rotation constant Be (also in wavenumbers) is defined as Be h/(8π2c µre2) (3) 1

The infrared absorptions observed in this experiment arise from transitions between v=0 and v=1, and various J" J', with J'=J"±1. Levels and J values are shown in Figure 1.1 The J for the initial, lower-energy, state is denoted J". The absorption wavenumbers, ω=[e(v=1,j )- E(v=0,J")]. Using equations 2 and 3, we see that absorptions are at the following wavenumbers: ω ωe + Be [ J (J +1) - J"(J"+1) ] (4) Absorptions for which J =J"+1 are said to belong to the "R" branch; those with Figure 1: rotational and vibrational levels. J =J"-1 are on This is Fig. 8 of reference 1. the "P" branch. The spectrum should look qualitatively like Figure 2, which is an actual low-temperature CO Figure 2. schematic P and R branches. This is Fig. spectrum.1 Note: spectrometers may plot ω (also 7 of reference 1. ν ) increasing either to the left or to the called ~ right. It is higher wavenumber, not left-right orientation, that defines the R branch relative to the P branch. Equation 4 is roughly correct in predicting rotation-vibration transition energies. Quantitative prediction of absorption frequencies requires consideration of three additional factors: centrifugal distortion, vibration-rotation coupling, and vibrational anharmonicity. The effective moment of inertia increases as J increases. This can be understood as the result of centrifugal force increasing the bond length in states having greater angular momentum. The effect is that energy levels do not increase with J as rapidly as equation 1 implies. A correction term -J2(J+1)2De is added to the energy E(v,J), to account for centrifugal distortion. De is called the centrifugal distortion constant, here in units of cm-1. (The same symbol De is used for dissociation energy.) Energy is also reduced by interaction between vibration and rotation, generally decreasing as both v and J increase. This effect is incorporated with the vibration-rotation interaction constant, αe. A 2

correction term -αe (v+½)j(j+1) is added to the energy E(v,J). As v increases, so does the bond length, which decreases the rotation constant. This effect is incorporated in Bv through αe: Bv = Be αe (v + ½) (5) Specifically, B0 = Be - ½αe, B1 = Be (3/2)αe, and B2 = Be (5/2)αe. Vibrational anharmonicity in CO causes energy to increase less rapidly with v than equation 1 predicts. This is because diatomic potential energy surfaces are generally less steep on the large-r side than perfect harmonic oscillator potential surfaces. A correction term -(v+½)2ωexe is added to the energy to account for anharmonicity. This experiment will measure two vibration-rotation bands, the fundamental with v:0 1 and the first overtone with v:0 2. Combining data from the fundamental and overtone allows calculation of the anharmonicity, xeωe. When these three effects are included, the energy (in wavenumbers) of a (v,j) state is E(v,J) = ωe(v+½) - ωexe (v+½)2 + BeJ(J+1) - αe(v+½)j(j+1) - DeJ2(J+1)2 (6) Taking the difference of two (v,j) states yields the following equations for the P- and R-branch absorption wavenumbers, as functions of the initial-state J'': ωp(j'') = ωv - 2BeJ" -αe J" (J"-2) + 4De(J")3 ; J"=1,2,3,... (7) ωr(j'') = ωv + 2Be(J"+1) -αe (J"+1)(J" +3) - 4De (J"+1)3 ; J"=0,1,2,... (8) ωv = v ωe v(v+1) xeωe. (9) Specifically, For the fundamental, v=1 and ωv = ω1 = ωe - 2 xeωe For the overtone, v=2 and ωv = ω2 = 2ωe - 6 xe ωe Equations 7 and 8 can be combined into a single equation in terms of the parameter m. m -J" on the P branch and m J"+1 on the R branch (10) ω(v,m) = ωv + (Bv +B0) m + (Bv-B0) m2-4 De m3 (11) Equation 10 will be used to analyze the CO spectra recorded in this experiment. For the fundamental band v=1 and for the overtone band v=2, in equation 11. Diatomic molecules have been used as test cases for quantum-chemical methods. Basis sets and electron-correlation methods have been tested on the first-row diatomics, including CO. The effects of various approximations on bond length, dipole moment, and vibration frequency have been studied. In this lab, restricted Hartree-Fock (RHF) theory and density functional theory (DFT, with the B3LYP functional) will be used to calculate ωe and Be, which can be compared with the experimental results obtained from analyzing infrared spectra. DFT, unlike RHF, includes electron 3

correlation. Electron correlation refers to the instantaneous repulsion between two electrons. Uncorrelated methods such as RHF include electron-electron repulsion only in a spatially-averaged way. Including electron correlation tends to lengthen bonds and lower vibration frequencies and rotation constants. Calculations done for this lab will test that generalization. Experimental Procedure This experiment uses three pieces of equipment. A long-path (4.8 meter) gas cell. A Fourier-transform Infrared (FTIR) Spectrophotometer A gas manifold with a pump, pressure gauge and CO tank The long-path gas cell is shown at right. It is shown with two rubber stoppers inserted in the base, to keep humid room air away from the Figure 3: cell potassium bromide windows that are in the base. The stoppers should be in place except when the instrument is in the sample compartment of the FTIR. The picture shows the cell s stopcock closed, to prevent loss of CO to the lab. The sample cell fits in the sample compartment of the FTIR. The stopcock is closed. Figure 4: cell in sample compartment The rubber stoppers have been removed from the base of the cell. 4

To evacuate the cell and then fill it with carbon monoxide gas, use the manifold and pump in the hood. Filling the cell involves slowly opening a closed glass system to a high-pressure gas, so Wear goggles Check that the hood is working (look at its gauge) before opening the CO tank. Keep the hood sash down as far as possible Open valves slowly and carefully. The cell is attached to the manifold and evacuated by opening the stopcocks between Figure 5. Filling the cell. the pump and the manifold and the cell and manifold. Rinse the cell with air several times in order to remove residual CO, CO 2, SO2, CS2 or other sample gases. To remove 99% of an earlier sample, fill the system with air and pump down at least four times. Evacuate the cell to the extent the pump permits, about 200mbar. Close the stopcock to the cell. Remove the rubber stoppers from the cell base. Place the cell in the FTIR sample compartment. Record a background spectrum. Settings: 500 to 4500 cm-1 range, 0.5 cm-1 resolution, collect and average 4 or more scans. After recording the background spectrum, reattach the cell to the manifold. Check that the needle valve on the CO tank is closed. Open the main valve on the CO tank. With the stopcock to the pump closed, CO gas is introduced from the tank by slowly opening the needle valve. Fill the manifold until the desired gas pressure is reached. A pressure of 30 mbar CO may work well. (If the evacuated pressure was 200 mbar, then the total pressure with CO would be about 230 mbar.) Return the gas cell to the FTIR sample compartment. Record the infrared spectrum of the fundamental transition. Record the spectrum from 2050 to 2250 cm-1. Mark peak locations. Print the spectrum or save it as an image. Reattach the cell to the manifold. Bring the CO pressure in the cell to 200-300 mbar. The total pressure would be that plus the evacuated pressure. Return the gas cell to the FTIR sample 5

compartment. Record the overtone spectrum from 4150 to 4350 cm-1. Mark the locations of 30 to 40 peaks, in cm-1. (Peak absorbances are not needed.) Print the spectrum or save it as an image. Include both the fundamental spectrum and the overtone spectrum in your lab report. After taking a spectrum, reconnect the cell to the manifold. Rinse with air and pump down a few times to remove nearly all carbon monoxide. Return the cell to the desiccator. The rubber stoppers should be in the base. Leave the cell s stopcock closed in the desiccator. Hazard: Carbon monoxide gas is poisonous. It should be released only in the hood, not in the open lab. Keep the hood sash down so the hood draws air well. 6

Spectral-based calculations Enter into a spreadsheet the wavenumbers of 30-40 lines each of the fundamental and the overtone spectrum. Assign each line to the P or R branch. Assign J and m values to every line. (See equation 10 and the qualitative spectrum near equation 4.) Plot wavenumbers versus m. Fit the fundamental lines to equation 11. Letting c0, c1, c2 and c3 represent the constants in the cubic equation 11, ω(v,m) = c0 + c1 m + c2 m2 +c3 m3 (12) Do a linear regression calculation to obtain the values of the intercept c0 and the three coefficients c1, c2 and c3. From the coefficients, calculate ω1, B0, and B1. Units are wavenumbers (cm-1) for each quantity. ω1 = c0, the intercept (13) B0 = ½(c1 - c2) (14) B1= ½(c1 + c2) (15) The uncertainty in ω1 is the same as that in c0: take it directly from the regression statistics. The centrifugal distortion coefficient could be calculated from c3 (De = -c3/4) but we will calculate De using a different method, below, because c3 usually is excessively uncertain. Fit the overtone lines to equation 11. Do a linear regression calculation to obtain the intercept and three coefficients. From the intercept and coefficients, calculate ω2, B0, and B2. ω2 = c0 B0 = ½(c1 - c2) B2= ½(c1 + c2) (16) The uncertainty in ω2 is the same as that in c0: take it directly from the regression statistics. Combine fundamental and overtone results to calculate ωe, xeωe, Be, αe and De, all in wavenumbers (cm-1). ωe = 3 ω1 - ω2 (17) xe ωe = ( 2ω1 - ω2 )/2 (18) Bv depends linearly on (v+1/2), as stated in equation 5. Bv = Be - αe (v+1/2) (19) The experiment should have provided four "y" values: B0, B0, B1, and B2. Graph these versus the "x" values 1/2, 1/2, 3/2 and 5/2. The intercept is Be. The slope equals -αe. Include the graph and regression statistics (from which, take uncertainties for Be and αe) in your lab report. From Be, calculate the bond length, Re. (Equation 3 relates the two.) Finally, calculate the centrifugal distortion constant from the "Kratzer" relationship 2,3 for diatomic molecules. 4 B 3e De = (20) ω 2e Compare ωe, xeωe, Be, αe and De to literature values.4-7 7

Quantum-chemical Calculations Do two quantum-chemical calculations on the CO molecule. Each calculation should be a geometry optimization and vibration frequency calculation. Use two theories, Hartree-Fock (RHF) and density functional theory (DFT) with the B3LYP functional. For each calculation, use the 6-311+G(d,p) basis set. That basis set is on WebMO's menu of basis sets. When you preview the GAMESS input file you will see the basis set specified as $BASIS GBASIS=N311 NGAUSS=6 NDFUNC=1 NPFUNC=1 DIFFSP=.TRUE. $END. The command "DIFFSP" corresponds to the "+" in the basis set name, NDFUNC=1 to the "d", and NPFUNC=1 to the "p". When using density functional theory with the B3LYP functional it is necessary to add this line to the input file: $FORCE METHOD=SEMINUM $END That causes GAMESS to use a slower "semi-numerical" method of calculating the Hessian matrix, to calculate the vibration frequency. The default analytical method seems not to work with DFT B3LYP. If one forgets, an error message in the output file reminds. For each calculation, report total energy, vibration frequency, bond length, and rotation constant Be. Table 1. QuantumChemical Results Hartree Fock (RHF) 6-311+G(d,p) DFT B3LYP 6-311+G(d,p) E (Hartree) ωe (cm-1) Re (Angstroms) Be (cm-1) Compare RHF and DFT-B3LYP results. Because correlation energy is negative (i.e., stabilizing), you should find the DFT energy to be lower than the RHF energy. Compare the better of the two theoretical calculation's results to your experimental results. 8

References 1. Albert, Sieghard, "Fundamentals of vibration-rotation spectroscopy," chapter 4 in Handbook of High-Resolution Spectroscopy, M. Quack and F. Markt, Eds., Vol. 1, Wiley: Chichester, 2011. 2. Lefebvre-Brion, Helene; Field, Robert W. The Spectra and Dynamics of Diatomic Molecules, Elsevier: San Diego, 2004. Page 286, equation 5.1.25. 3. Bernath, Peter F., Spectra of Atoms and Molecules, Oxford University Press: New York, 1995. Page 174, equation 6.48. 4. Herzberg, Gerhard, Molecular Spectra and Molecular Structure. Volume I. Spectra of Diatomic Molecules, D. Van Nostrand Co, Inc.: Princeton, New Jersey, 1950. Page 522. (The ground electronic state is X2Σ+.) UMD library QC451.H464 1950 Vol.1. 5. Rank, D. H.; Guenther, A. H.; Saksena, G. D.; Shearer, J. N.; Wiggins, T. A. Tertiary interferometric wavelength standards from measurements on lines of the 2-0 band of carbon monoxide and derived wavelength standards for some lines of the 1-0 band of carbon monoxide. The velocity of light derived from a band spectrum method. IV. Journal of the Optical Society of America, 1957, 47(8), 686-689. UMD library PER 4817. 6. Mina-Camilde, Nairmen; Manzanares I; Caballero, Julio F. Molecular constants of carbon monoxide at v=0, 1, 2 and 3. Journal of Chemical Education, 1996, 73(8), 804-807. 7. Sinnokrot, Mutasem Omar; Sherrill, C. David. "Density functional theory predictions of anharmonicity and spectroscopic constants for diatomic molecules," Journal of Chemical Physics, 2001, 115(6), 2439-2448. 9